Installation Datasheet

Similar documents
Lonworks Damper Interface Catalogue

Smoke Damper Interface (230V)

Smoke Fire Damper Interface (230V)

Fire Damper Interface (230V)

Catalogue. ActionpacEMSStandard. Electro Mechanical Control & Monitoring System.

Fire Damper Interface (24V)

Actionpac 60/120 (LNS Standard)

Actionpac LNS3 Intelligent Damper Control and Monitoring System

V3 Intelligent Damper Control and Monitoring System

October 2013 Bespoke Intelligent Damper Control and Monitoring System

Safegard V4 Bespoke Intelligent Damper Control and Monitoring System

Instructions for the fan motor control system with integrated wiring terminals SILVER C

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Residual Current Devices

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

Instructions for the fan motor control system, SILVER C

SURFACE WARM CEILING HEATERS

SEALING FIBER SEALING COMPOUND

RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL

Smoke Vent Control Panel PCB4 V4 Installation Manual

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

LEAKSTOPPER RANGE Multizone water leak detection systems

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

US Filtermaxx. 200,000 BTU Waste Oil Burner

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

SAVE THESE INSTRUCTIONS

Installation Instructions VITOTRONIC 300

NON-SUBMERSIBLE WATER PUMP

1U ULTRA Compact System

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

VEROTEC Electronics Packaging

INSTALLATION INSTRUCTION for ceiling fan

INSTRUCTION MANUAL (English version) Water still

SEMPEO SQA Unit Code H02H 04 Wiring electrical equipment and circuits

User s Manual. For the SHORE POWER CONNECTION MONITOR MODEL 9151

Manifold Installation Controller MIC-180. Installation and Operation Instructions

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Actionair. Hot/Shield PTC. BROCHURE UPDATED* High Operating Temperature Smoke Management and Fire Dampers

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

OG5000 Ozone Generator Model OG5000B-A. User Manual

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

LEAKSTOPPER 1 Single zone water leak detection system

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

PANTHER. Condensate removal pump Installation and operating guide

LC2200 Level Controller Installation and Maintenance Instructions

HOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher

Instruction Manual. Vapour Pump Thermal Snap-Switches. Cooling-Fail Thermal Snap-Switch

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

Viking Installation Guide

INDOOR USE ONLY. Installation and Maintenance XTRACTOR. (ESX) 1 and 3 phase, Direct Drive, Fans for indoor use

Level 3 NVQ Diploma in Domestic Plumbing and Heating ( /025)

Installation Instructions VITOTRONIC 200

owner s manual & parts list

KM300 Carbon Monoxide Detection System Installation Manual

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

NXM2G Installation and Operating Manual

INSTALLATION AND OPERATION GUIDE

Parts and Service Manual

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

Fire and Smoke Control Systems

Installation & Operating Instructions

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Installation and Wiring Instructions

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Installation, Operating and Servicing Instructions

Multi-Zone Wireless Control Training Systems ( )

RE-PR3-E-27 3-Phase Panel Mount 27kW

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

Model: AC-108. Instruction Manual

PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

ART cm Island Curved Glass

1 INCA INCA MODEL FPC FIRE PUMP CONTROL PANEL. (Star Delta/D.O.L) USER MANUAL Inca Reference FPC Revision 1.0

COMMERCIAL ELECTRIC DRYER

Installation and operation manual

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

WARNING FIRE DOOR CLOSING

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for vented systems.

WAILEA OWNER S MANUAL

ORION Mini-Rep INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY)

RHT RAIL HEATER. Rail & Switch Point Heating System. Pre-Terminated Lengths or Cut-to-Length from the Reel

F6102 Installation & Operating Instructions for the Parrotuncle Owner s Installation,Manual WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

MINERVA MX. 800 Series Ancillary Equipment

Flame Safeguards LFE10. Building Technologies HVAC Products

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

INTELLI-VAC 14 INTELLI-VAC 18

THE QUALITY BRAND IN FANS

TRONIC 6000C. Tankless electric whole house water heaters. Models: WH17 / WH27. [en] Installation Manual and Operating Instructions

Surface Warm Ceiling Heaters

Transcription:

Safegard EMB Installation Datasheet The panel is built to meet project specific requirements, see project drawings for details. This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product will directly put at risk the lives of the occupants and the fabric of the building. Always READ this document BEFORE INSTALLATION. Please Retain for future reference. - PAGE 1 -

Mounting Only use the mounting brackets provided. Mounting Diagram The height of the unit above the floor level should be chosen so that the centre of the panel is just above normal eye level (approximately 1.5 m). The unit should be placed in a naturally vented area and this area should be considered fire safe and free from high levels of shock and vibration. Conditions should not arise which may allow the temperature in this area to reach or exceed the operating temperature of the unit. Do not locate the unit where access to its internal components and connections are restricted. WARNING: Observe all health and safety procedures when lifting or moving this equipment. Preparation Only trained and qualified personnel should be allowed to install, replace or service this equipment. Installation should be in accordance with the relevant local safety standards. Panel sizes & weights Panel sizes and weights are dependent on project specific requirements. The mains wiring should comply with IEC 60227 or IEC 60245. A switch or circuit breaker should be included as part of the installation. The switch or circuit breaker should meet the relevant requirements of IEC 60947-1 and IEC 60947-3. The switch or circuit breaker should be in close proximity to the equipment and be within easy reach of the operator. The switch or circuit breaker should be marked as the disconnecting device for the equipment and should disconnect both poles of the supply. The switch or circuit breaker should not interrupt the protected earth conductor. This equipment MUST be earthed. - PAGE 2 -

Installation Wiring Diagram 1 (Mains supply feed) 1. Disconnect the local supply before commencing any work on this equipment. 2. Wire the mains supply feed in accordance with wiring diagram 1. When complete, secure the mains cable using a cable gland (by others). 3. Wire the incoming mains cable in accordance with wiring diagram 2. 4. Wire the incoming live (brown) and neutral (blue) wires to the mains terminal. Max 4mm 2 wiring. 5. Connect the incoming earth (green and yellow) wire to the protected earth stud using a ring connector. This connector must be fitted and secured independently using the shake proof washer and nut provided. The floating panel earth wire should be connected on top of this using the additional shake proof washer and nut provided. GLAND CIRCUIT BREAKER OR SWITCH 6. The mains cable should be fitted in such a manner that, should the cable be subject to strain, the earth wire would be the last wire to break loose. 7. Finally, the mains wires should be tie wrapped to prevent slippage. Once wiring is complete, apply power to the equipment. Wiring Diagram 2 (Incoming mains cable) PROTECTIVE EARTH STUD GLAND E L N - PAGE 3 -

Alarm Input(s) Wiring The volt free alarm input is a closed contact that opens in alarm The input cable diameter should be 1mm 2 or 1.5mm 2 Limit cable runs to 100m and avoid running input cables near sources of mains or noisy environments. INPUT Terminal Number 1 201, 202 2 203, 204 etc. Number of inputs is dependent on project specific requirements General Fault Output Wiring Dampers Wire the first damper actuator supply as shown in the specific project drawing and repeat for subsequent dampers. Wire the first damper actuator end position switch wiring as shown in the specific project drawing and repeat for subsequent dampers. It is recommended that the damper end position cables are not run alongside any high voltage or high frequency sources as this could render the panel indication unreliable. Please note: 2 core and 3 core site wiring (by others). Typically, 1mm 2-2.5mm 2 solid core wiring. Be aware of voltage drop when using 24V (Mode 5) actuators. It is the user s responsibility to ensure the switched equipment is adequately protected. OUTPUT Terminal Number Common 401 Fault 402 Normal 403 etc. Number of outputs is dependent on project specific requirements Please note: All panel terminals (except mains supply) accept max 2.5mm 2 wiring - PAGE 4 -

Typical EMB Electro-Mechanical System Schematic Incorporating SmokeShield PTC TM (24V Actuator, Control Mode 5 illustrated) SUPPLY 230V 1ph DAMPER SUPPLY *24V AC 1 2 FIRE ALARM PANEL (By Others) SAFEGARD EMB ELECTRO-MECHANICAL CONTROL PANEL OR 1 2 3 4 5 24V ACTUATOR SMOKESHIELD PTC CONTROL MODE 5 6 3 CORE INDICATION BACK FROM EACH INDIVIDUAL MODE 5 N.B. If required to operate with any other smoke / fire spring return actuator please refer to Technical Sales. INTERFACE : 1 No. VOLT FREE CONTACT PER ZONE(S) 1 X 2 CORE CABLE PER INTERFACE(S) JUNCTION BOX (by others) OR ACTIONAIR DCB (OPTIONAL). 1 x 3 CORE BMS RELAY OUTPUT(S) (NORMAL/FAULT) - PAGE 5 -

Typical EMB Electro-Mechanical System Schematic Incorporating SmokeShield PTC TM (230V Actuator, Control Mode 6 illustrated) SUPPLY 230V 1ph DAMPER SUPPLY 230V AC 1 2 FIRE ALARM PANEL (By Others) SAFEGARD EMB ELECTRO-MECHANICAL CONTROL PANEL 1 2 3 4 5 230V ACTUATOR SMOKESHIELD PTC CONTROL MODE 6 6 LOW VOLTAGE 3 CORE INDICATION BACK FROM EACH INDIVIDUAL MODE 6 N.B. If required to operate with any other smoke / fire spring return actuator please refer to Technical Sales. INTERFACE : 1 No. VOLT FREE CONTACT PER ZONE(S) 1 X 2 CORE CABLE PER INTERFACE(S) JUNCTION BOX (by others) OR ACTIONAIR DCB (OPTIONAL). 1 x 3 CORE BMS RELAY OUTPUT(S) (NORMAL/FAULT) - PAGE 6 -

Typical Network Schematic (230V Actuator, Control Mode 6 illustrated) LEVEL 1 LEVEL 2 LEVEL 3 1. 2. 3. 1. SmokeS hield PTC Control Mode (must specify if Mode 5 = 24 VAC or Mode 6 = 230 VAC). 1m flying leads supplied with actuator (mode) 2. Junction Box (by others) or Actionair DCB (Optional). GROUND VFC General Fault Output(s) if required EMB VFC Fire Alarm Input(s) 3. 2 core and 3 core site wiring (by others). Typically, 1.5mm 2-2.5mm 2 solid core wiring. - PAGE 7 -

Specification Supply Input voltage Alarm Input(s) Contact type General Fault Output Contact type Maximum switched load (230 ± 23) V AC, 50 Hz Non-isolated dry contacts SPCO mechanical relay contact 1 A at 230 V AC 1 A at 30 V DC Environmental Operating temperature 0 C to 35 C Storage temperature -15 C to 45 C Humidity Maximum altitude 80 % RH to 25 C decreasing linearly to 50 % RH at 35 C 2000 m Complies with European standards WARNING: The responsible body shall be made aware that, if the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. The information herein is subject to change without notice. We do not assume any liability arising out of the use of this product. Purchase of goods and services is subject to Safegard Systems standard terms and conditions. Product warranty 12 months from date of delivery. Actionair and Safegard are brand names of Swegon Air Management and Safegard Systems respectively and both companies are part of the Swegon Group. Swegon Air Management, South Street, Whitstable, Kent, CT5 3DU, UK T: 01227 276100 F: 01227 264262 E: sales@actionair.co.uk www.actionair.co.uk Unit 33, Southern Cross Business Park, Bray, Co. Wicklow, A98 HT99, Ireland T: +353 1 2761600 F: +353 1 2761611 E: info@safegard.ie www.safegard.ie - PAGE 8 -