FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

Similar documents
Manual PCE-889 pyrometer

IRT2 Dual Laser IR Thermometer - User Guide

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

Dual Laser InfraRed (IR) Thermometer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

High Temperature InfraRed Thermometer with Laser Pointer

R2310. Infrared Thermometer. Instruction Manual

Dual Laser InfraRed (IR) Thermometer

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

Manual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

Model ST-128M Moisture Detector

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

64 Max IR Thermometer

Users Manual. Visit us at

I/R Thermometer Gun 12:1

62 MAX/62 MAX + Infrared Thermometer. Users Manual

IR D USB INFRA RED THERMOMETER

62 MAX/62 MAX + Infrared Thermometer. Users Manual

64 Max IR Thermometer

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

62 MAX/62 MAX + Infrared Thermometer

CA876 INFRARED K-THERMOMETER WITH LASER ENGLISH. User Manual. Auto OFF

NON-CONTACT VOLTAGE DETECTOR WITH ADJUSTABLE SENSITIVITY AND IR THERMOMETER USER S MANUAL

562/563. Infrared Thermometers

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

Infrared Thermometer. Getting Started

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

Infrared Thermometer

62 MAX/62 MAX + Infrared Thermometer

Precision Infrared Thermometer. Users Manual

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

INSTRUCTION MANUAL ROTARY LASER LEVEL GPR-R40H / G40

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

NON-TOUCH THERMOMETER User Manual

MT4 MAX/MT4 MAX + Infrared Thermometer

RS Pro Infrared Temperature Sensor

62 MAX/62 MAX + Infrared Thermometer

Users Manual. Infrared Thermometer

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

Visit us at testo 835 Infrared and contact thermometer

INSTRUCTION MANUAL DIRL-GL

u Do not use the appliance if any part is damaged or defective. u Do not short battery terminals. u Do not charge batteries.

100 Ft. LASER DISTANCE METER

M15-GSL12P30 M15-GSL12P30S Heat Spy Infrared Thermometer User Manual

User Manual. Non-contact Infrared Thermometer.

Class 1 laser beam sensor safe for your eyes

TECHNICAL FILE LEVELS AND MULTI-FUNCTION DETECTORS

Motorised Infrared Optical Beam Smoke Detector. User Guide

Table of Contents Title Page Introduction Contacting Uni-Trend Safety Information Features Display Buttons and Connector How the Thermometer works.

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

Class 1 laser beam sensor safe for your eyes

FIRERAY 5000 range USER GUIDE

Motorised Infrared Optical Beam Smoke Detector. User Guide

OWNERS MANUAL OPERATION GUIDE

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

1. INTRODUCTION FEATURES SPECIFICATIONS PANEL DESCRIPTION OPERATING INSTRUCTION MAINTENANCE...6

Class 1 laser beam sensor safe for your eyes

Wide Temperature Range Low Cost Max Temperature Display Tripod Mountable Applications

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

Laser Collimated Beam Sensor

Laser Distance Sensor Type M Analog-Output

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

Model R9100. REED Instruments Instruction Manual. Ultrasonic Leak Detectortor

Infrared Temperature Sensor

USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

ARE ALL SINGLE-WAVELENGTH INFRARED THERMOMETERS ALIKE?

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Instruction Manual. Self-Leveling Laser Level Model No

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

Fluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE

THB4002. GoTemp Food Infrared Thermometer With Laser Sighting And Thermocouple Jack User Guide. Measuring Temperature The Smart Way.

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

Self-Leveling Five-Beam Laser Pointer Model No Instruction Manual

THERMOFOCUS 01500A3 THERMOFOCUS

Innovative Technology for Traditional and Challenging Applications

An FT-NIR Primer. NR800-A-006

User s Guide. OSXL685 and OSXL689. High Performance Infrared Thermometer. Shop online at

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

Precision Infrared Thermometer. Users Manual

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

User s Manual IS MODEL

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

CLETEF-786. Infrared Thermometer Instruction Manual

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

POWER METER INSTRUCTION MANUAL

Break-in Detection and Alarm System

THERMOFOCUS 0800H5 Professional

Operation GT7000. Time / Current Temp. TEMP UP button. Display. Fan. Switch. Set Temp. Display. Mode Switch. Backlight. TEMP DOWN button.

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

Instruction Manual. Model No and Self-Leveling Cross-Line Laser Level

Transcription:

Model Infrared Food Thermometer FS-200 Instruction Manual reedinstruments com

Table of Contents Safety... 3 Features... 3 Specifications... 4 Instrument Description... 5 Display Description... 5 Operating Instructions...6-7 Field of View... 7 MODE functions... 7 Battery Replacement... 8 reedinstruments com 2

Safety Do not let the beam enter your eye, another person s eye or the eye of an animal Do not shine the beam off of a reflective surface into your eye Do not direct the laser beam towards any gas that can explode Features Precise non-contact measurements Built-in laser pointer Resolution to 0.1º Caution temperature setting button LED indicators for low and high temperatures Automatic Data Hold Auto power off Backlit LCD display Wide range of applications Field of View of 8:1 For service on this or any other REED product or information on other REED products, contact REED Instruments at info@reedinstruments.com reedinstruments com 3

Specifications Display: Temperature Range: Resolution: 0.1º Accuracy: Sample Rate: Emissivity: 3 1/2 digit (1999count) LCD with backlighting -50 to 200ºC (-58 to 392ºF) -50 to -20ºC (-58 to -4ºF): ±5ºC (±9ºF). -20 to 200ºC (-4 to 392ºF):. ±2% of reading or ±2ºC (±4ºC) 2.5/second 0.95 fixed value Field of View: Approx 8:1 distance to spot ratio with 90%. encircled energy at focal point Diode Laser: Spectral Response: Power Off: Operating Temperature: Operating Humidity: Storage Temperature: Storage Humidity: Power Supply: Weight: Size: Includes: Output <1mW, Wavelength 630~670nm,. class 2 (II) Laser product 6~14um 7 seconds of inactivity 0 to 50ºC (32 to 122ºF) 10 to 90% RH -20 to 60ºC (-4 to 140ºF) <80% RH One 9V battery 180g 82 x 41.8 x 60mm Battery and Carrying Case reedinstruments com 4

Instrument Description 1. IR Sensor 2. Laser Pointer 3. LCD Display 4. Laser Button 5. Backlight Button 6. LED Temperature. Range Indicator 7. MODE Button 8. Trigger 9. Battery Cover 10. Handle Grip Display Description 1. Digital Readout 2. Temperature Unit 3. Measuring Indicator 4. Data Hold Indicator 5. Low Battery Indicator 6. Laser Pointer Indicator reedinstruments com 5

Operating Instructions 1. Hold the meter and point it toward the surface to be measured 2. Pull an hold the Trigger to turn the meter on and begin measuring, which is indicated by the SCAN icon on the LCD screen 3. Push the Laser Button and aim the laser approximately half an inch above the measuring point (pressing the Laser Button again turns the laser off) 4. Push the Backlight Button to turn on the LCD backlight 5. Release the Trigger and the HOLD display icon will appear on the LCD indicating that the current measurement is being held on the screen 6. The meter will automatically power down after approximately 7 seconds of inactivity Notes: The meter will take up to 30 minutes to adjust from high ambient temperatures to low ambient temperatures Not recommended for measuring shiny or polished metal surfaces (stainless steel, aluminum, etc) This meter cannot measure through transparent surfaces, it will measure the surface temperature Steam, dust, and smoke can prevent accurate measurement by obstructing the unit s optics reedinstruments com 6

Field of View This meter s field of view is 8:1, meaning that if the meter is 8 inches from the target the diameter of the object under test must be at least 1 inch in size. The target needs to be larger than the unit s spot size. The smaller the target, the closer you should be to it. When accuracy is critical, make sure the target is at least twice as large as the spot size. See below for more information, or refer to the side of your meter for the same diagram. MODE functions 1. Pull the trigger to turn the meter on 2. Press the MODE button once to switch the temperature unit from ºC to ºF, press the Backlight button or the Laser button to switch between the two 3. Press the MODE button a second time to set the High Alarm (HAL), and adjust the high temperature alarm by pressing the Backlight button to increase, and the Laser button to decrease (when the temperature is outside of the HAL, the red light will appear) 4. Press the MODE button a third time to set the Low Alarm (LAL), and adjust the low temperature alarm by pressing the Backlight button to increase, and the Laser button to decrease (when the temperature is outside of the LAL, the red light will appear). reedinstruments com 7

Battery Replacement If you see the Low Battery Indicator on the LCD screen, you will need to change the battery. 1. Open battery cover 2. Remove the battery from the meter and replace with a new 9-Volt battery 3. Replace the battery cover Notes reedinstruments com 8