CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

Similar documents
CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

We re more than products. We re a constant flow of energy and ideas. At Carling, we re always on, powered by a passion for finding creative

M7100 Pressure Transducer

M5800 Pressure Transducer with Rotatable Display

M5200 Industrial Pressure Transducer

M5800 Pressure Transducer with Rotatable Display

U5300 Industrial Pressure Transducer

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

D5100 Industrial Differential Pressure Transducer

D5100 Industrial Differential Pressure Transducer

RE-PR3-E-27 3-Phase Panel Mount 27kW

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

U5700 Submersible Liquid Level Pressure Transducer

REA 105 Arc Protection Module. Operator s Manual

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

U5600. Wireless Pressure Transducer SPECIFICATIONS

SOLARLOK Interconnection System Installation Manual

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

AO Annunciator Module

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Guideline No.: S-02(201510) S-02 Navigation Light and Signal Light Controllers. Issued date: October 20,2015. China Classification Society

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

G3 Electric Lubrication Pump For Series Progressive and Injector-based Systems

LC1350 Level Controller

G3 Electric Lubrication Pump For Series Progressive and Injector-based Systems

VAMP 120 & 121. Arc flash detection units. Product picture

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

ACCS-30. Multipoint commercial heat-tracing control system

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

OPERATION MANUAL MODEL & ACCELEROMETER

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

Quadrature Speed and Direction Sensors

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CII FCAC-150 Series Relay

RAYCHEM NGC-30 COMPONENTS

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

4 & 8-POINT ANNUNCIATORS Instruction Manual

Designer & Application Notes. Securtiy Termination. belfuse.com/cinch

Application Note #603 Revision A June 2016 Lighting Control for Noise-Sensitive Applications

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

Detection, Protection, Innovation

Harrier + Smart Controller & Chemical Management System

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

CPS V Cabinet Power System

A D U ANNUNCIATOR DIM / TEST UNIT INSTALLATION MANUAL DESCRIPTION AND THEORY OF OPERATION

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

SensaGuard TM Integrated Latch Installation Instructions

HTC-915-CONT. Heat-Trace Control system

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Transportation Attitude Reference System (TARS Series) Ruggedized Inertial Measurement Unit (IMU) Issue 2. Datasheet

Ceiling Microwave presence/absence detector 12-24V AC/DC

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

INSTRUCTION & SERVICE MANUAL

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

OPERATION MANUAL MODEL 805 ACCELEROMETER

INTERNATIONAL STANDARD

Dräger QuadGard Control System

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

MARC70 Installation Manual

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

DGC-500 DIGITAL GENSET CONTROLLER

The best in connector value... today, tomorrow and into the future!

G3 Electric Lubrication Pump

LC3000 Level Controller Installation and Maintenance Instructions

Series 45 Pumps Fan Drive Control (FDC)

INPUT / OUTPUT MINI MODULES

DESCRIPTION FEATURES WARNINGS APPLICATIONS

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

OPERATION MANUAL Model 8011 & mA

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

INSTRUCTION MANUAL (ATEX / IECEx)

Sensepoint XCL Fixed Gas Detector

Residual Current Devices

MODEL 4000A & 4001A ACCELEROMETER

IQAN-LC5-C02 Input Devices. Catalog HY /US for North America

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Heavy Duty Pressure Transducers Line Guide

Transportation Attitude Reference Sensor (TARS Series) Ruggedized Inertial Measurement Unit (IMU)

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

WH EN IGH T T C LO SED

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Transcription:

CLM-Series - Solid State Power Controller - Overview CLM-SERIES SOLID STATE POWER CONTROLLER The CLM-Series is a 12 output, solid state power controller. It provides fast switching with low loss solid state On/Off functions, accurate current measurement, short circuit protection and Pulse-Width Modulation (PWM) function. The outputs can be connected in parallel for higher current capacity. The CLM-Series also provides interface with up to 7 discrete inputs. The discrete inputs can be configured as an active-high or active-low logic. The maximum current capacity of this unit is 75 Amps. Relative to electromechanical relays, the CLM-Series can increase thermal efficiency by providing lower power dissipation and providing higher power-to-weight densities. The CLM-Series provides improved safety and reliability while reducing vessels down time, operator s work load, overall vessel weight and wiring complexity. The CLM-Series is available with Molex and DEUTSCH connectors. A3660 Molex Version Product Highlights: CAN NMEA2000 communication Meets 100 V/m Electric Field Programmable trip level for each Electronic Circuit Breaker output Resolution 1 Amp Six (6) outputs at 10 Amps max each Two (2) outputs at 15 Amps max each (A3660) Two (2) outputs at 12 Amps max each (A3670) Four (4) outputs at 5 Amps max each Voltage back feed blocking circuit for each output Short circuit protection circuit for each output Model Numbers: CLMM12 Marine, Molex Connector, NMEA2000 certified CLMD12 - Marine, DEUTSCH Connector, NMEA2000 certified A3670 Deutsch Version Removal of OctoLite cover in the field will compromise the operation of the unit and voids warranties set forth by Carling Technologies. *Manufacturer reserves the right to change product specification without prior notice. Please refer to our website for the latest details. 1

CLM-Series - Solid State Power Controller - Overview Additional Features All outputs are PWM capable for light dimming Frequency: 200Hz Maximum PWM peak current: 3A Inductive Loads (Motors) not recommended Duty cycle adjustable from 5 to 100% at 1% resolution Current Measurement accuracy +/- 0.5 Amps (Typical) Current Measurement Resolution 0.1 Amps Minimum current measurement 0.5 Amps 75 Amps maximum capacity Seven (7) discrete inputs configurable as (Active High, Active Low, Open) NMEA2000 proprietary bootloader for software and configuration updates Low current LED modules require adding a 1 KΩ ±5% 2W resistor, this will prevent the LED from glowing when output power is OFF Real-time fault monitoring for all (12) outputs, including: Open circuit detection (Open Load, loads must be greater than 1 Amp) Short circuit/over current Outputs can be paralleled for higher current capacity Only parallel two channels with the same current rating. Wiring recommendation: Run two outputs wire together with matched impedance. Maximum current rating when two channels are paralleled is typically 180% of the single channel rating. (Example: maximum for two 10A channels in parallel). See tables below for recommended parallel channels: A3660 Recommended Parallel Outputs: A3670 Recommended Parallel Outputs: Paralleled Outputs Output 7 (15A) & Output 4 (15A) Output 9 (5A) & Output 6 (5A) Output 6 (5A) & Output 12 (5A) Output 3 (5A) & Output 12 (5A) Output 5 (10A) & Output 8 (10A) Output 2 (10A) & Output 8 (10A) Output 2 (10A) & Output 10 (10A) Output 1 (10A) & Output 10 (10A) Max Current 27A Paralleled Outputs Output 7 (12A) & Output 4 (12A) Output 9 (5A) & Output 6 (5A) Output 6 (5A) & Output 12 (5A) Output 3 (5A) & Output 12 (5A) Output 5 (10A) & Output 8 (10A) Output 2 (10A) & Output 8 (10A) Output 2 (10A) & Output 10 (10A) Output 1 (10A) & Output 10 (10A) Max Current 22A All illustrations are for reference purposes only. Nothing contained in this document shall replace or modify the requirements of Industry Standard s applicable to wire or other protection, including without limitation, those of the American Boat and Yacht Council (ABYC); the National Electric Code (NEC); and/or the National Fire Protection Association (NFPA). Failure to install the CLM System or any components thereof in compliance with any such Industry Standard may limit the warranties made by Carling Technologies, Inc. *Manufacturer reserves the right to change product specification without prior notice. Please refer to our website for the latest details. 2

CLM-Series - Solid State Power Controller - General Specifications General Specifications Electrical Voltage Input 6.5 to 32 VDC Max Current Capacity 75 Amps Serial Communication CAN NMEA2000 2 High Side Outputs 15 Amps each (A3660) 12 Amps each (A3670) 6 High Side Outputs 10 Amps each 4 High Side Outputs 5 Amps each 7 Discrete Inputs Active High, Active Low, Open Mechanical (A3660) Dimensions (L x W x H) 5.7 x 4.2 x 1.33 Weight (max) 1.25lbs (0.567 kg) Degree of protection IP69K Torque Value 20 in-lbs. (2.26 N/m) (voltage input stud) J2 Mating connector Molex P/N 0334721201 J1 Mating connector Molex P/N 0334721601 Mechanical (A3670) Dimensions (L x W x H) 5.7 x 5 x 1.6 Weight (max) 1.32 lbs (0.599 kg) Degree of protection IP67 Torque Value 20 in-lbs. (2.26 N/m) (voltage input stud) J1 Mating Connector Deutsch DT06-12SA J1 Socket Deutsch 0462-209-16141 (14 AWG) J1 Wedge Deutsch W12S J2 Mating Connector Deutsch DT06-08SA-E003 J2 Socket Deutsch 0462-201-16141 (16 20 AWG) J2 Wedge Deutsch W8S J3 Mating Connector Micro-C Male Environmental High Temperature Soak EN 60068-2-2:2007 Section 2 or 4 Low Temperature Soak EN 60068-2-1:2007 Temp. Cycling (Operational) IEC 60068-2-14:2009 Test Nb Temp. Shock (Storage) IEC 60068-2-14:2009 Test Na Simulated Solar Radiation EN 60068-2-5:2010 Procedure B Altitude (Transport) EN 60068-2-13:1999 Altitude (Operational) EN 60068-2-13:1999 Test M: Low air pressure Humidity (Soak) EN 60068-2-78:2002 Humidity (Cyclic) EN 60068-2-30:2005 Dust Ingress IEC 60529:2001 Section 13 Water Ingress DIN 40050-9:1993 IEC 60529:2001 Section 14 Mechanical Shock (Drop Test) EN 60068-2-32:1993 Test Ed: Free Fall. Procedure 1. Mechanical (Shock) 60068-2-27:2009 Mechanical (Bump) 60068-2-29:1993 Vibration (General) 60068-2-6 : 1996 Vibration (Random) EN 60068-2-64:1995 Method 1 Vibration (Resonant Search) 60068-2-6 : 1996 Chemical Resistance EN 60068-2-74:2000 Test Class B Salt Spray EN 60068-2-52: 1996 Ozone ASTM D1171-99 Method 1 Electrical (Operating Voltage) SAE J1455:2011 Section 4.13.1 Electrical (Over Voltage) SAE J1455:2011 Section 4.13.1 Electrical (Reverse Polarity) SAE J1455:2011 Section 4.13.1 Electrical (Short Circuit) SAE J1455:2011 Section 4.13.1 Electrical (Power Up) SAE J1455:2011 Section 4.13.1 Electrical Transients Immunity ISO 11451-1:2005 ISO 114522:2004 Electrical Transients Emissions ISO 13766:2006 Section 5 Annex D and Annex E Electrical Transients ISO 13766:2006 Conducted Transients ISO 7637-2:2011 Electrostatic Discharge (ESD) ISO 13766:2006 Certifications NMEA2000 CE Category B IEC 60533 Electrical and Electronic Installations in Ships IEC 60945 Maritime Navigation and Radio Communication Equipment and Systems GPS-8009 Rev: C 3

CLM-Series - Solid State Power Controller - Dimensional Specifications Dimensional Specifications in. [mm] 5.10 REF [129.5] NOTES: 1. WEIGHT: 1.25 LBS. (0.567 KG.) MAX. 2. TEMPERATURE: OPERATING -40 C TO 55 C. STORAGE -55 C TO 85 C. 3. MATING CONNECTIONS: J1 - DEUTSCH P/N DT06-12SA J2 - DEUTSCH P/N DT06-08SA-E003 J3 - MICRO-C MALE CONNECTOR, M12 X 1 4.11 REF [104.4] 4.99 REF [126.6] 5.71 REF [145.1] 2.80 REF [71.1] 1.58 REF [40.2] 1/4"-20 THREADED POWER STUD 5.100±0.010 [129.54±0.25] 1.55 REF [39.5] (STUD) 1.54 REF [39.2] (J1) (J2) (J3) 4.110±0.010 [104.39±0.25] M6 THREADED SCREW HOLE (3 PLACES) 2.800 [71.12] MOUNTING HOLE PATTERN SCALE 1.000 A3670 CLA-8139 Rev: A 4

CLM-Series - Solid State Power Controller - Dimensional Specifications Dimensional Specifications in. [mm] 5.10 REF [129.5] NOTES: 1. WEIGHT: 1.25 LBS. (0.567 KG.) MAX. 2. TEMPERATURE: OPERATING -40 C TO 55 C. STORAGE -55 C TO 85 C. 3. MATING CONNECTIONS: J1 - MOLEX P/N 0334721601 J2 - MOLEX P/N 0334721201 4.11 REF [104.4] 4.99 REF [126.6] 5.71 REF [145.1] 2.80 REF [71.1] 1/4"-20 THREADED POWER STUD 5.100±0.010 [129.54±0.25] 1.55 REF [39.5] 1.33 REF [33.8] (J2) (J1) 4.110±0.010 [104.39±0.25] M6 THREADED SCREW HOLE (3 PLACES) 2.800 [71.12] MOUNTING HOLE PATTERN SCALE 1.000 A3660 CLA-8139 Rev: A 5

CLM-Series - Solid State Power Controller - Dimensional Specifications Dimensional Specifications in. [mm] VIEW SHOWING TYPICAL CABLE INSTALLATIONS TO THE DC DISTRIBUTION BOX (A3660) A3700 OUTPUT FLYING LEADS CABLE ASSEMBLY (J2) A3701-2 INPUT FYLING LEADS CABLE ASSEMBLY (J1) CLA-8139 Rev: A 6

Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 Email: sales@carlingtech.com Northern Region Sales Office: nrsm@carlingtech.com Southeast Region Sales Office: sersm@carlingtech.com Midwest Region Sales Office: mrsm@carlingtech.com West Region Sales Office: wrsm@carlingtech.com Latin America Sales Office: larsm@carlingtech.com Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 Email: sales@carlingtech.com.hk Shenzhen, China: shenzhen@carlingtech.com Shanghai, China: shanghai@carlingtech.com Pune, India: india@carlingtech.com Kaohsiung, Taiwan: taiwan@carlingtech.com Yokohama, Japan: japan@carlingtech.com Europe Middle East Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 Email: ltd.sales@carlingtech.com Germany: gmbh@carlingtech.com France: sas@carlingtech.com CONTROL & MONITORING SYSTEM www.octoplex.com REV_11_2018