Mediflow hand dryer. All installation, maintenance and repair tasks must be carried out by qualified technicians.

Similar documents
Optima hand dryer. All installation, maintenance and repair tasks must be carried out by qualified technicians.

Junior hand dryer. All installation, maintenance and repair tasks must be carried out by qualified technicians.

Service Manual for / How to Remove the Cover

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Owner s Guide and Installation Manual

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Table of Contents. Ceiling Bracket Installation

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Installation and Operation Manual For Hunter Ceiling Fans /16/2004

5LCM52XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : AC-552AL

SERVICING INFORMATION

INSTRUCTION MANUAL MODEL: 690E

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

THE MONTICELLO CEILING FAN INSTALLATION INSTRUCTIONS

Owner s Guide and Installation Manual

Installation and Operation Manual For Hunter Ceiling Fans

SERVICE MANUAL. Freestanding cooker 500 and 600 / Range Gas- gas Electric CFSGSV14 CFSGWH14 CFSESV14 CFSEWH14

installation and operation manual for Hunter Ceiling Fans

Table of Contents. What to Expect with Your Installation. Tools Needed. Mounting Options. Ceiling Bracket. Wiring.

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Type 2 Models. Owner s Guide and Installation Manual. English Español

BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

OWNERS INSTRUCTION MANUAL

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Owner s Guide and Installation Manual

Installation and Care Instructions

Installation Instructions

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Switch Housing.

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

Owner s Guide and Installation Manual

WAILEA OWNER S MANUAL

Table of Contents What to Expect with. Mounting Options. Tools Needed. Downrod. Blades

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Installation Guide. Model: IC15- MF Model: IC15- MFSilent Model: IC30- MF Model: IC30- MFSilent

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Downrod. Canopy.

USER MANUAL. PEDESTAL FAN (16 Inch)

What to Expect with Your Installation. Tools Needed. 30 inches PA G E. To register your fan, please visit: 11 PA G E

Owner s Guide and Installation Manual

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Preparation. Downrod. Maintenance.

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

Owner s Guide and Installation Manual

5DI52XXD/5DI52XXD-L Series Fan UL Model No. : 5DI52. Owner s Guide and Installation Manual

TECHNICAL INFORMATION T 15xx Dryers

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Downrod. Blades. Maintenance & Cleaning.

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

WHITMAN Owner s Manual

Table of Contents. 1 M /10/14 Casablanca Fan Company. What to Expect with Tools Needed.

Innes. Instruction Manual A Kichler Decor ceiling fan. Includes our new TM

THE MUSE CEILING FAN INSTALLATION INSTRUCTIONS

SUTTON 52 CEILING FAN

LUCCI AIRFUSION QUEST II CEILING FAN

Highland ManorTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

TECHNICAL INFORMATION Touchtronic Clothes Dryers

Owner s Guide and Installation Manual

THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS

THE COLTON CEILING FAN INSTALLATION INSTRUCTIONS

PROXIMA PATIO CEILING FAN INSTALLATION INSTRUCTIONS

3CLMR56XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3CLMR56XXD

THE FLEX CEILING FAN INSTALLATION INSTRUCTIONS

TOUCHDOWN 48 CEILING FAN

BAY BRIDGE CEILING FAN

Installation and Care Instructions. Wood Blinds and Alternative Wood Blinds. LiteRise Touch System. Getting Started

SPRINGHILL 44 CEILING FAN

Owner s Guide and Installation Manual

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

THE BRISTOL CEILING FAN INSTALLATION INSTRUCTIONS

HW-17 Record Cleaning Machine Setup and Instruction Manual

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

installation and operation manual for Hunter Ceiling Fans

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

INSTALLATION INSTRUCTIONS. Aluminum Blinds - Standard - - Lift & Lock -

THE MISSION CEILING FAN INSTALLATION INSTRUCTIONS

Installation Instructions

gas Understanding Gas Appliance Conversions READ ALL INSTRUCTIONS

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

Owner s Guide and Installation Manual Manual De Propietario

TECHNICAL INFORMATION T1500 Series Clothes Dryers

SERVICE MANUAL. Freestanding cooker 500 and 600 / Range Gas - electric Ceramic - electric Electric

Parts & Material Included

Sunburst. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

ST. KITTS CEILING FAN

Eliza 56 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

Oscillating Ceiling Fan

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

2 Installation Instructions For Vari-Fan Ceiling Fans Installation Instructions For Vari-Fan Ceiling Fans 11

READ AND SAVE THESE INSTRUCTIONS

Bubble 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS

Transcription:

Mediflow hand dryer Safety regulations All installation, maintenance and repair tasks must be carried out by qualified technicians. Mediclinics remembers the importance of: 1. Becoming familiar with the equipment and carefully reading the user manual prior to operating. 2. Disconnecting power prior to beginning any repair or maintenance action. 3. Exercising care in accordance with the procedures included herein. General maintenance Preventive Maintenance - Cleaning Inspect the units annually or quarterly, depending on the dryer s operating cycles. Clean the active parts of the unit, such as: the motor, the heating element, the fan and the electronic circuit board with a soft brush. Maintain the air inlet and outlet free of dust and other obstructions; use a soft flat ended brush. Removal of the casing Consult the safety regulations prior to carrying out any work on the unit. Release the screws that attach the casing (2 units) using the supplied tamperproof screwdriver.

The casing is fixed to the base by means of inner bolts. Extract the lower part of the casing, as shown in the image, and lift it slightly to release the anchors. To avoid scratching the casing, place it on a flat surface with the visible part facing upward.

Motor Characteristics - Type: Universal brush motor - Power: 250 W - Speed of rotation: 5,500 rpm - Class F - Incorporates a safety thermal limiter Maintenance The corrective maintenance of the motor consists of replacing the brushes. The brushes have a theoretical useful life of 3,000 hours and must be replaced when their length is shorter than 5 mm. Replacement of the brushes Press the clip that holds the brush.

Move the clip to one side to release the brush. Remove the brush from its location and replace it. Carry out the same procedure for the second motor brush. Assemble by following the previous steps in reverse order.

Replacement of the motor Disconnect the two cables of the motor that go to the two-way terminal block of the electronic circuit board. For greater safety, we recommend you disconnect the three cables of the heating element that go to the two-way terminal block of the electronic circuit board.

Carefully remove the electronic circuit board from the guide located at the base by bending the clips that are located in the volute. Use pliers to carefully extract the two circlips that secure the heating element.

Rotate the heating element a quarter turn clockwise, until it is released from its anchors. Carefully remove the heating element from its position.

Release the screw attaching the volute to the base. Carefully open the volute by bending the two clips that secure it to the base.

Remove the heating element ring located to the left of the fan. Loosen the set screw that secures the fan to the drive shaft, inserting an Allen key through the hole in one of the fan blades. Remove the fan.

Release the two lateral springs that fasten the motor. Carefully remove the motor from its position and replace it. Fit it by following the previous steps in reverse order.

Heating element Characteristics - Band type wound wire heating element in Cr, Al and Fe. - On MICA body. - Power: 2,500 W. - Incorporates a thermal limiter. - Automatic disconnection 0.5 seconds before the motor stops. Maintenance As preventive maintenance, we recommend using a soft brush to remove dust and dirt on an annual or bi-annual basis, depending on the dryer s operating cycles. Replacement of the heating element Disconnect the two motor cables that go to the two-way terminal block of the electronic circuit board.

Disconnect the two heating element cables that go to the two-way terminal block of the electronic circuit board. Carefully remove the electronic circuit board from the guide in the base by bending the clips located in the volute.

Use pliers to carefully extract the two circlips that secure the heating element. Rotate the heating element a quarter turn clockwise, until it is released from its anchors.

Remove the heating element from its housing in the volute and replace it. Fit it by following the previous steps in reverse order. Electronic Circuit Board Characteristics - Electronic sensor, with infrared beam. - Detection distance adjustable by potentiometer (5-25 cm). Maintenance As preventive maintenance, we recommend using a soft brush to remove dust and dirt on an annual or bi-annual basis, depending on the dryer s operating cycles. It is also recommended to clean the LEDs regularly using a cloth dampened with alcohol to ensure the signal is emitted and received properly.

Replacement of the electronic circuit board Disconnect the two motor cables that go to the two-way terminal block of the electronic circuit board. Disconnect the two cables of the heating element that go to the two-way terminal block of the electronic circuit board.

Disconnect the electronic circuit board from the terminal block that is located in the junction box of the base. Disconnect the electronic circuit board from the terminal block that is located in the junction box of the base.

Free the electronic circuit board by bending the clips located on the volute. Remove the circuit board carefully so as not to damage its components. Fit it by following the previous steps in reverse order. Insert the circuit board into the guide at an angle of 45º for it then to be positioned perpendicular to the base.

Position of the jumper at low sensitivity: detection distance between 15 and 20 cm. Notes: The dryer is supplied with the jumper set in the low sensitivity position. The lighting conditions of the installation site can alter the detection distances.