Illuminated Stopper Station Push Button

Similar documents
Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Stopper II Heated Enclosure

EPO STATION. EPO Station with push to activate, turn to reset button complete with a clear cover to help

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ

Addendum for STI-6406 with Dual Access Control

Stopper II SERIES ADA. We protect the things that protect you

SPECIFICATIONS. Contents List

Exit Stopper. STI-6400 Series

Exit Stopper. STI-6400 Series

PEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

Lumination TM Volumetric Retrofit Kit

Protective Cabinet STI-7534, STI-7535 and STI-7535AED

MICROWAVE OVEN UNDER-THE-CABINET INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION FOUR À MICRO-ONDES SOUS PLACARD MURAL

Lumination TM Controls Accessory LPL Series Controller Box

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

Installation and ZONES: Operation Manual. Model: ON STI-34108

GARAGE DOOR OPENER KIT

PDD-FT-3. Fire Panel Interface With EOL Trigger. Installation and Specifications Manual

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

200i User s information manual

Tetra MAX. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

Installation Instructions

Occupancy Sensor OCS 100W Setup Guide

FES - Series Portable Electric Heaters

QAA 142 Termination instructions Self-regulating trace heaters type ELSR-NA and -HA in Div1 with heater entry kit EL-HAZELECT Kit part No: 09CA051

INSTALLATION INSTRUCTION In-Ground

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

Installation Instructions

Siemens Automation Products Siemens AG All rights reserved A5E AB, 08/2017 1

Foot control. No instrument selected. A Raise chair Chair to working position 1 B Incline backrest Chair to spitting. positioning

Wi-Fi DOOR/WINDOW SENSOR

Installation, Operation and Maintenance Manual

GE Monogram. Installation Instructions. Built-In Dishwashers. with Optional Trim Kit. Models ZBD5600 ZBD5700 ZBD5900

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

Wireless Outdoor Air Reset Adaptor PN:

Installation, Operation and Maintenance Manual

Installation Instructions If you have questions, call or visit our website at:

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Installation Instructions

PUREFIRE GAS BOILERS USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER

INSTALLATION INSTRUCTION In-Ground Color Changing

USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER.

Installation, Operation and Maintenance Manual

Installation Instructions If you have questions, call or visit our website at:

Kit Instructions COMMON VENT KIT (PVC AND DURAVENT)

SOLA SM II Light Engine Instruction Manual

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

INSTALLATION INSTRUCTIONS

520 Series. AngleMix Thermostatic mixing valve NA Function

INSTALLATION INSTRUCTIONS

Aquatron 4, 8, /95 Form Number Instructions For Use. Advance Models , , , ,

Installation Instruction Danfoss RX-C Roof and Gutter De-Icing System

Installation Instructions If you have questions, call or visit our website at:

OPERATING INSTRUCTIONS INSTRUCTIONS DE FONCTIONNEMENT

Instruction Manual Advanced Mini Block Heaters Advanced Mini Block Heater with Heated Lid

SERIES PSCII GAS BOILERS

WINDSHEAR STORM and WINDSHEAR STORM DELUXE MODEL NO: 98778/98780

installation manual DM3862 RM2554 DM2663 RM2551 Refrigerator for LP-gas & electric operation DM2852 ! AVERTISSEMENT ! WARNING FOR YOUR SAFETY

Switching power supply. Additional Information on page 2 Input rating: Vac, 50-60Hz, 2.5A Output rating: 24Vdc, 8.33A max., 200W max.

Operation & Care Instructions Save For Future Reference ABOUT THE MACHINE

Installation Instructions

Location Requirements

BruteTM. User s Manual for. Modulating Boiler Model BNTH Sizes MBTU/h. Water Heater Model BNTV Sizes MBTU/h. with Touchscreen Display

SZ-PIR04N ZigBee Motion Detector Installation Guide

DELTA HEAT SIDE BURNER

PH:

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

GLAS. Installation Instructions

Installation Instructions

Laptop Computer (OLPC)

Concerning the use of GP4000 Series Graphic Operator Interface for applications in potentially explosive atmospheres (Zones 2/22)

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

520 Series. TankMixer water heater tank mixing valve NA Function

Smoke Control Listed LCM-OAVS VAV with HW Reheat, Two Venturi Air Valves (One Exhaust, One Supply) including BTU Compensation

Electrical/Electronics

Installation Instructions

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

FLOW-THROUGH FURNACE HUMIDIFIER

PH:

INNCOM e7 Thermostat Installation Instructions FOR ALL UNITS IN CARTON. DO NOT THROW AWAY!

Gas Equipment. Volume 1 January/February Issue date: February 4, 2009

UV/White LED Light Source Kit

EcoView Thermostat. Product Description. Installation. Product Number. Caution Notations. Required Tools. Expected Installation Time.

Gas Equipment. Volume 4 June/July Issue date: June 27, 2007

Installation Instructions

Escape Series Walk-in Bathtub Models 5128 and 5332 (soaker, water, air and microbubble jet models)

Type examination certificate: INERIS 07ATEX3003X and Additions 01/02

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

CHUGGER PUMP Chugger Max Models

Atomic Digital Office Clock

1100X Wireless Receivers

Warmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL AUTOMATED SYSTEMS ENGINEERING ENCLOSURE TYPE 3R

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

Mascot LX. User s Information for. Wall-Mounted, Modulating Boiler Model MLXH 50, 75, 100, 125, 150, 175, & 220 MBH

Narrow Depth Reach-in Refrigerator And Freezer Refrigerator model: 178A19RHC, 178A23RHC, 178A49RHC Freezer model: 178A19FHC, 178A23FHC, 178A49FHC

GE Monogram. Automatic. Icemaker. Installation Instructions. Models ZDI15 ZDIS15. monogram.com

Gas Equipment. Volume 3 May Issue date: May 11, 2007

Transcription:

Illuminated Stopper Station Push Button Model SS2xx6 Rely on STI

Dimensions 4.880 in [123.95 mm] 3.218 in [81.74 mm] 1.625 in [41.28 mm].875 in [22.23 mm] Switch Rating 2 momentary independent Form C contacts, DPDT Rated at: 10A, 125/250VAC; ½ HP 6A, 30 VDC 100,000 operations Temperature: 32 F to 120 F (0 C to 49 C) NO NC NOTE LED connection is polarity sensitive. If LED does not light, switch positive and negative wiring or remove LED and rotate 180. 24 volt is included and will operate on 12 volts; however not as bright. 12 volt LED s are also available. - 2 - COM LED TERMINALS

Safety Notice to Installers and Users This push button has been tested according to UL2017. It is important to read, understand and follow all instructions provided with this product. Non-fire alarm initiating devices are listed in UL category UEHX. It is the installer s responsibility to comply with NEC and Canadian electrical code, mounting specifications according to ADA and other applicable fire and electrical codes. To avoid electrical shock, DO NOT attempt to install this product when power is on. To avoid possible confusion with fire alarm initiating devices, do not mount a red stopper station near a manual fire alarm initiating device. ADA mounting compliance requires the operable part of the initiating device shall not be less than 1.1m (3 1/2 ft.) or greater than 1.37m (4 1/2 ft.) above finished floor service. After installation and testing are complete, provide a copy of this manual to all personnel responsible for testing and maintenance of this product. Push buttons for outdoor use must be mounted with STI outdoor rated covers. Remarques sur l installation: Ce bouton-poussoir a été testé selon UL2017. Il est important de lire, de comprendre et de suivre toutes les instructions fournies avec ce produit. Les dispositifs de déclenchement d alertes non incendie sont répertoriés sous la catégorie UL UEHX. Il incombe à l installateur de se conformer aux normes NEC et Code canadien de l électricité, aux spécifications de montage selon l ADA et aux autres codes de prévention des incendies et de l électricité en vigueur. Pour éviter un choc électrique, NE tentez PAS d installer ce produit lorsqu il est sous tension. Pour éviter toute confusion possible avec les dispositifs de déclenchement d alertes d incendie, n installez pas un avertisseur Stopper rouge à proximité d un dispositif de déclenchement d alarme d in cendie manuel. La conformité aux règles d installation de l ADA exige que la partie utilisable du dispositif de déclenchement soit installée à une hauteur située entre 1,1 m (3 1/2 pi) et 1,37 m (4 1/2 pi) au-dessus du plancher fini. Une fois l installation et les essais terminés, vous devez fournir une copie de ce manuel à l ensemble du personnel chargé de l essai et de l entretien de ce produit. Les boutons poussoirs pour utilisation à l extérieur doivent être installés avec couvercles pour l extérieur de STI. - 3 -

Install or Remove Contact Block INSTALL To attach, align tabs (as shown) and gently snap top then bottom. Be sure to hear BOTH tabs snap into place. (Can be reversed if wiring comes from the bottom of the box.) REMOVE Repeat STEP A for the top and bottom tab before pulling on contact block. Step A: Position small flat screwdriver blade under tab and gently rotate until tab disengages. The contract block will rotate a little. DO NOT PULL YET. Step B: Repeat for opposite tab. Step C: When both tabs are disengaged, pull the contact block straight off. KIT-71100 B (OP A STEP A COMPLETED STEP A B STEP B - 4 - STEP C

#6-32 x 1 in. PHILLIPS HEAD MACHINE SCREW (2) PROVIDED #8-32 x 3/8 in. SCRE TOP TOP TAB - 5 -

Mounting DRILL OUT THE (4) MOUNTING HOLES, ONE IN EACH CORNER, USING 5/32 in. DRILL BIT BACKBOX MUST BE MOUNTED WITH ARROWS POINTING UP 1.625 in. (41.28mm) 1.575 in. (40.01mm) - 6 -

LED TERMINALS Surface Mounting #6-32 x 1 in. PHILLIPS HEAD MACHINE SCREW (2) PROVIDED KIT-71100A-COLOR BACKBOX (OPTIONAL) #8-32 x 3/8 in. SCREW #6 x 1-1/4 in. PHILLIPS PAN HEAD SCREW (4) PROVIDED w/ KIT-71100A-COLOR DRILL POINT PROVIDED TOP & BOTTOM FOR 1/2 in. CONDUIT. DRILL AS NEEDED #8-10 7/8 in. ANCHOR (4) PROVIDED w/ KIT-71100A-COLOR DRILL (4) 3/16 in. DIAMETER HOLES A COMPLETED - 7 -

Testing Approvals It has been tested and approved or listed by: Underwriter Laboratories and cul No. S7255. Warranty Three year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components). Electronic warranty form at www.sti-usa.com/wc14. WARNING: This product can expose you to chemicals including Dichloromethane, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov. Printed in USA 2306 Airport Rd Waterford, MI 48327, USA Phone: 248-673-9898 Fax: 248-673-1246 info@sti-usa.com www.sti-usa.com Taylor House 34 Sherwood Road Bromsgrove, Worcestershire B60 3DR England Tel: +44 (0)1527 520 999 Fax: +44 (0)1527 501 999 info@sti-emea.com www.sti-emea.com Inst. Sht. SS2xx6 JULY2018