LIMITED INDOOR MOLD ASSESSMENT

Similar documents
INDOOR ENVIRONMENTAL QUALITY EVALUATION

WHAT YOU NEED TO KNOW ABOUT MOLD IN YOUR HOME

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

RW West Consultants. Property Inspection Report

Inside Out Home Inspections

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032


RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

FAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017

PREPARED FOR: (Name of Client) CONCERNING: (Address of Property) BY: P Home. YOUR HOME CHECK 1305 FM 359, Suite G F

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

Excellent Home Inspection Services, LLC

156 Egret Street, Covington, LA * * MOLD/IAQ SCREENING REPORT

Steve Ramsey Home Inspections

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

Indoor Air Quality Testing. Horry County Schools

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017

Terry Building Inspection report summary with all items addressed or explained in red

THE CROWN SERIES. Coco, Jackson & Myrtle Floorplans REV *With Craftsman Package

"A Brief Guide to Mold, Moisture, and Your Home"

FAIRA TRANSPARENCY REPORTS. November 21, 2016

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109

The Villas of Wyldewood

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017

Bayshore House Inspections LLC

Axiom Property Inspections

A Brief Guide to Mold, Moisture, And Your Home

FAIRA TRANSPARENCY REPORTS SE 279th St, Maple Valley, WA March 7, 2018

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

South Richland Provincial and Estate Homes

FAIRA TRANSPARENCY REPORTS nd Ave S, E-2, SeaTac, WA 98198

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275

Watson Home Inspection Services, LLC.

Jeff Brown Inspections

GUIDELINES FOR MOLD REMEDIATION (REMOVAL)

Shown with optional metal roofs, front door with transom, upgraded porch columns, and landscape package. Yardley Model

Cascade Inspection Services, LLC

CMHC HOME MAINTENANCE CHECKLIST

I. STRUCTURAL SYSTEMS

Inspection Report 123 My Street Midland, GA

FAIRA TRANSPARENCY REPORTS Stone Ave N, #205, Seattle, WA 98133

FAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017

Canadian Property Inspections

FAIRA TRANSPARENCY REPORTS th Ave SE, Renton, WA June 13 th, 2017

FAIRA TRANSPARENCY REPORTS Spruce Way, Lynnwood, WA August 21, 2017

INDOOR ENVIRONMENTAL QUALITY EVALUATION

DESIGNER KITCHEN WITH PREMIUM APPLIANCES 1407 & 1409 Military Trail Features & Finishes 1. Open concept kitchen with NEFF designer cabinetry and Caesa

LIMITED MICROBIAL & IAQ SURVEY CLOSING REPORT SOUTHEASTERN SCHOOL DISTRICT 02/12/2015

Home Maintenance Schedule

FAIRA TRANSPARENCY REPORTS SE 240th Pl, Maple Valley, WA June 5th, 2017

While most maintenance is seasonal, there are some things you should do on a frequent basis year-round:

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017

Hearth and Homes Inspections, llc

Ph: (907) Quality Homes

NARRATIVE REPORT. Underlayment Paper for Linoleum. The Asbestos Bulk Sample Results Table includes asbestos sampling data.

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

5400 Lawn Avenue Western Springs, IL 60558

FAIRA TRANSPARENCY REPORTS. January 27 th, 2017

Inspector Gadget Homes

CENTRAL GREAT PLAINS SERIES

FAIRA TRANSPARENCY REPORTS Alaskan Way, 514, Seattle, WA 98101

FAIRA TRANSPARENCY REPORTS Fairview Ave E, #304, Seattle, WA June 7 th, 2017

Preventative Maintenance. Fairbanks House, Dedham Massachusetts Built 1637

FAIRA TRANSPARENCY REPORTS W Villa Monte Dr, Mukilteo, WA August 8 th, 2017

ADDRESSING MOISTURE AND MOULD IN YOUR HOME

FAIRA TRANSPARENCY REPORTS Chestnut Street, Everett, WA 98201

Some Sampling Issues. Common Causes of mold problems 3/3/2017

FAIRA TRANSPARENCY REPORTS. 553 Chelan Pl NE, Renton, WA March 3 rd, 2018

Landscape Includes sprinkler system Irrigation, system maintenance, and landscape upkeep are all included in H.O.A. dues

FAIRA TRANSPARENCY REPORTS. July 6, 2016

FAIRA TRANSPARENCY REPORTS NE 117th Pl, #F8, Kirkland, WA 98034

Home Inspection Report

SITE SYSTEMS: FANNIE MAE EXPECTED USEFUL LIFE TABLES (FMEUL)

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

FAIRA TRANSPARENCY REPORTS SE 265th St, Covington, WA October 10, 2017

Platinum Features - Multi Section

FAIRA TRANSPARENCY REPORTS NE 108th St, Redmond, WA April 4 th 2017

Troy's Home Inspection Services LLC

Mold Inspection Standards of Practice

Mold Inspection Standards of Practice. IAC2 Mold Inspection Standards of Practice. Table of Contents

CUSTOM HOME BUILDER ON YOUR LOT OR OURS SERVING THE DFW MARKET CLASSIC SERIES

Home Inspection Report

FAIRA TRANSPARENCY REPORTS W James St, 8, Kent, WA 98032

THERE IS NOTHING STANDARD ABOUT OUR FIXTURES AND FINISHES.

622 City Park Avenue (504) New Orleans, LA (504) Fax

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015

FAIRA TRANSPARENCY REPORTS th Dr NE, Lake Stevens, WA April 4th, 2017

Extra Mile Inspection, Inc.

Interior & Exterior Finishes & Specifications for The Bradford & Weston Style Homes

ce Is the Key Seasonal Home Maintenance Inspecting help keep live. help you. person to round: snow or debris. test button, which should then cause the

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS Harbour Pointe Blvd, #301h, Mukilteo, WA 98275

Inspection Report. Cheri Maisonneuve. Property Address: 103 Dogleg Dr Moultrie GA. Welcome Home! Premier Home Inspections of Valdosta, LLC

ASBESTOS AND LEAD-BASED PAINT SURVEY 696/698 Hawthorne Avenue St. Paul, Minnesota. Prepared for:

CUSTOM HOME BUILDER ON YOUR LOT OR OURS SERVING THE DFW MARKET SIGNATURE SERIES

Homes in Cates Bay - Overview

Indoor Environmental Quality Residential

Transcription:

LIMITED INDOOR MOLD ASSESSMENT RESIDENTIAL PROPERTY 1022 NORTHWEST 27 TH STREET SAN ANTONIO, TEXAS PREPARED FOR: PREPARED BY: LUCAS OLIVA ARGUS ENVIRONMENTAL SAN ANTONIO HOUSING AUTHORITY 10004 WURZBACH RD., #247 818 SOUTH FLORES STREET SAN ANTONIO, TEXAS 78230 SAN ANTONIO, TEXAS 78204 PHONE: (210) 477-6004 PHONE: (210) 493-2560 FAX: (21) 477-6015 FAX: (210) 342-9027 PROJECT NUMBER: 0804153ARG WRITTEN BY: MARK D. FREEMYER, CIEC PROJECT MANAGER TX MAC LICENSE #0188 (Exp. 1/4/2010) REVIEWED BY: ROBERT W. MILLER, CIH, CSE TX MAC LICENSE #0187 (Exp. 12/16/2008) DATE OF ISSUE APRIL 30, 2008

Table of Contents 1. Executive Summary...3 2. Report of Findings...6 3. Laboratory Data... Appendix I 4. Photographs... Appendix II 2

EXECUTIVE SUMMARY Argus Environmental was contacted by the San Antonio Housing Authority to conduct a Limited Mold Assessment within the residential property located at 130 Arboles, San Antonio, Texas. The onsite Mold Assessment occurred on April 22, 2008. The Scope of Services included in the Limited Mold Assessment consisted of the following: Visual investigation of accessible areas Limited sample collection event Microbiological analysis by a certified and licensed third party lab Report documenting the findings of the evaluation Conclusions and Recommendations Argus Environmental s entire liability pertaining to this report and all work associated with it is limited to the INVOICED amount defined within the Scope of Services. Conclusions The irregularity to the baseboard at the front entry s left side may be the result of the observed inadequacy in the threshold weather stripping. Water damage to the Kitchen s cabinet shelf below the sink is the consequence of an ongoing water supply leak from the cold water shut off valve. The Kitchen s damaged flooring in the dishwasher cavity is likely evidence of past leakage. Dust accumulation observed in the HVAC air handling unit is likely the outcome of historical use with a low efficiency filter. Water distress at the head and/or foot ends of the tubs in the Hall and Master Bathrooms is likely evidence of historical usage patterns by previous occupants. Air samples collected for microbiological analysis indicated that the total mold presence inside the residence was less than outside. No significant variations from the outside molds were present in the indoor samples. Recommendations The top of the landscape grade along the home s south exterior wall should be lowered to a point that is 3 inches below the bottom of the lowest row of siding. The damaged south exterior corner trim should be cut off and replaced. 3

The front doorway should be evaluated and additional weather stripping added, as appropriate. Kitchen/Breakfast Nook remove and properly dispose of the left and right side doorway trim along the exterior wall. Conduct a visual assessment of the exposed gypsum board materials. If mold is present, then remove and dispose of the baseboard along the same wall to the left and right sides of the door. Then remove and properly dispose of the exterior wall gypsum board in a 2 ft by 2 ft section on each side of the base of the doorway. Then remove and properly dispose of the exposed batted insulation. Then HEPA vacuum the wall cavities and sanitize the wood framing with a scrub brush applied 20% bleach solution. Appropriate protection should be taken to protect personnel with the use of gloves and eye protection. NOTE: Organic vapors are associated with the use of bleach. Adequate ventilation with fresh air and/or the use of a respirator equipped with an organic vapor acid gas cartridge may be required in order to prevent occupational exposures. The Kitchen/Breakfast Nook exterior door should be adequately repaired to prevent future water penetration. Make appropriate repair to the dryer exhaust vent through the exterior wall in the Utility Room. The Kitchen s cabinet shelf below the sink should be removed after fixing the plumbing leak. A visual assessment of the remaining cabinetry and exposed gypsum board should be completed. If suspect mold growth is observed, contact Argus Environmental for additional recommendations. The flooring in the dishwasher cavity should be HEPA vacuumed and then wet wiped with a 20% bleach solution before reinstalling a dishwasher following the appropriate personal protective measures indicated above. The interior of the air handling unit shall be HEPA vacuumed to get the dust off the insulation and the condensate coil should be cleaned following the manufacturer s recommendations. Finally, a pleated filter should be installed. Hall Bathroom remove and dispose of the caulking and baseboard at the head end of the tub. Remove and properly dispose of a 1x1 foot section of gypsum board up from the floor at the base of the tub. The exposed wall cavity s wood framing should be HEPA vacuumed and wet wiped with a 20% bleach solution following the appropriate personal protective measures indicated above. Master Bathroom remove and properly dispose of the caulk along the tub at the floor. Remove the baseboard at each end of the tub and conduct a visual assessment of the exposed gypsum board. If suspect mold growth is observed, remove and properly dispose of a 1x1 foot section of gypsum board up from the floor at each end of the tub. The exposed wall cavities wood framing should be 4

HEPA vacuumed and wet wiped with a 20% bleach solution following the appropriate personal protective measures indicated above. 5

I. Introduction Argus Environmental was contacted by the San Antonio Housing Authority to perform a Limited Indoor Mold Assessment at the residential property located at 1022 Northwest 27 th Street, San Antonio, Texas. The onsite evaluation occurred April 22, 2008. The evaluation was conducted in order to provide a physical assessment of the building s conditions and limited background characterization of the air quality in terms of temperature, relative humidity, and bioaerosals. II. Scope of Services The Scope of Services included in the Evaluation consisted of the following: Visual investigation of accessible areas Limited sample collection event Microbiological analysis by a certified and licensed third party lab Report documenting the findings of the evaluation Conclusions and Recommendations Argus Environmental s entire liability pertaining to this report and all work associated with it is limited to the INVOICED amount defined within the Scope of Services. III. General Building Description The San Antonio Housing Authority property located at 130 Villa Arboles is a one-story single family residential property located in the Mirasol subdivision. The structure is conventionally wood framed on a typical concrete slab-on-grade foundation. The roof is pitched of composite asphalt shingles. The roof is guttered along the front porch and walkway. The exterior is finished in a combination of Hardi-plank siding and brick. The drip edge and soffit are typical wood materials and the eve and porch soffit are vinyl. The window systems are aluminum framed and double paned. The interior of the residence is serviced by a single heating, ventilating and air conditioning (HVAC) system that is located in a closet adjacent the Living Room. Interior finish materials consisted of gypsum board walls and ceilings that were taped and floated with joint compound, textured and painted and flooring that was a combination of padded carpeting and rolled resilient vinyl flooring. IV. Historical Background Information The residence was unoccupied at the time of the Mold Assessment. V. Visual Observations For the purposes of the assessment the front of the home was assumed to be facing east. A very strong odor of new paint and new carpeting was present inside the property. 6

Exterior Caulk repairs to the siding joints were present on the exterior south side of the house (Photo 1). The bottom of the siding was well above grade with the exception of an ant hill towards the rear corner of the house where there was also some insect damage to the corner trim (Photos 2 & 3). The HVAC system s compressor unit had been purloined. Foyer Some irregularities were observed to the baseboard and threshold in the front doorway. Light was visible through the door s threshold (Photo 4). Utility Room The dryer exhaust vent was open to the outside with no rodent screen (Photo 5). Kitchen/Breakfast Nook The baseboards and door trim to the left and to the right of the door had visible sign of historical water intrusion. It looked like the entire interior of the door had been re-painted and caulked, although there was visible caulk joint separation at the lower left door frame (Photo 6). There was an active leak in the supply plumbing underneath the sink that appeared to be coming from the cold water shut off valve. There was a puddle on the bottom shelf of the sink cabinet and visible damage was present (Photos 7 & 8). The dishwasher had been removed and the rolled vinyl flooring was curled and separated from the concrete sub-floor (Photo 9). Living Room No visible signs of water intrusion, damage, or suspect mold growth were identified. HVAC Closet A filter was not in place for the air handling unit. The condensate coil looked reasonably clean; however, dust accumulation was present (Photo 10). Hall Bathroom There was evidence of water impact at the bottom of the tub and also some patching on the wall at the top of the tub. Bedroom #1 No visible signs of water intrusion, damage, or suspect mold growth were identified. 7

Bedroom #2 No visible signs of water intrusion, damage, or suspect mold growth were identified. Master Bedroom No visible signs of water intrusion, damage, or suspect mold growth were identified. Master Bathroom Minor historical evidence of water impact was identified at the head and foot ends of the tub; however, there was no visible suspect mold growth. Garage No visible signs of water intrusion, damage, or suspect mold growth were identified. VI. Sample Methodology A. Air Samples Air samples are collected on Zefon Air-O-Cell or Allergenco spore-trap cassettes for analysis via a microscopic screen. Culture plates are collected with an N-6 impactor: Potato Dextrose or Malt Extract Agar is used for analysis of culturable fungi. Spore-trap samples are collected at a rate of approximately 15 liters per minute for approximately 5 minutes. The culturable samples are collected at a rate of approximately 28.3 liters per minute for approximately 3 minutes. VII. Interpretation of Findings Refer to Appendix I for specific counts of particular sample results. A. Air Samples Two air samples were collected from inside the residential structure along with two additional outside air samples, which were used for comparison purposes. The air samples were collected from the following locations: 221AC 222AC 223AC 224AC Outside air sample #1, Front Return A/C fan on Entry Master Bedroom Outside air sample #2, Front The laboratory s microscopic and viable culture analysis identified lower total mold spore counts and environmental fungi in the indoor samples than the total count present outside with no significant variations in the genera distribution patterns. 8

VIII. Conclusions and Recommendations It should be noted that the information and conclusions within this report are based solely on the effects of the microbial contamination to the structure itself and should not be utilized to equate any physical symptoms or illness to the analytical results presented. Any concerns regarding possible health effects should be directed to a health care professional. In addition, Argus Environmental Consultants, LLC acknowledges the limitations of the sampling methodology in terms of absolute numerical valuations of mold content encountered within the structure at the time of each limited sample collection. Based upon the visual inspection, empirical microbiological and direct read instrument data analysis, Argus Environmental forms the following conclusions: The irregularity to the baseboard at the front entry s left side may be the result of the observed inadequacy in the threshold weather-stripping. Water damage to the Kitchen s cabinet shelf below the sink is the consequence of an ongoing water supply leak from the cold water shut off valve. The Kitchen s damaged flooring in the dishwasher cavity is likely evidence of past leakage. Dust accumulation observed in the HVAC air handling unit is likely the outcome of historical use with a low efficiency filter. Water distress at the head and/or foot ends of the tubs in the Hall and Master Bathrooms is likely evidence of historical usage patterns by previous occupants. Air samples collected for microbiological analysis indicated that the total mold presence inside the residence was less than outside. No significant variations from the outside molds were present in the indoor samples. Based on the information contained in this report the following recommendations are forwarded: The top of the landscape grade along the home s south exterior wall should be lowered to a point that is 3-inches below the bottom of the lowest row of siding. The damaged south exterior corner trim should be cut off and replaced. The front doorway should be evaluated and additional weather-stripping added, as appropriate. Remove and properly dispose of the left and right side doorway trim along the Kitchen/Breakfast Nook s exterior wall. Conduct a visual assessment of the exposed gypsum board materials. If mold is present, then remove and dispose of the baseboard along the same wall to the left and right sides of the door. Then remove and properly dispose of the exterior wall gypsum board in a 2-ft by 2-ft section on each side of the base of the doorway. Then remove and properly dispose of the exposed batted insulation. Then HEPA vacuum the wall cavities and sanitize the wood framing with a scrub brush applied 20% bleach solution. Appropriate protection should be taken to protect personnel with the use of gloves and eye protection. NOTE: Organic vapors are associated with the use of bleach. Adequate ventilation with fresh air and/or the use of a respirator 9

equipped with an organic vapor acid gas cartridge may be required in order to prevent occupational exposures. The Kitchen/Breakfast Nook exterior door should be adequately repaired to prevent future water penetration. Make appropriate repair to the dryer exhaust vent through the exterior wall in the Utility Room. The Kitchen s cabinet shelf below the sink should be removed after fixing the plumbing leak. A visual assessment of the remaining cabinetry and exposed gypsum board should be completed. If suspect mold growth is observed, contact Argus Environmental for additional recommendations. The flooring in the dishwasher cavity should be HEPA vacuumed and then wet wiped with a 20% bleach solution before reinstalling a dishwasher. Appropriate protection should be taken to protect personnel with the use of gloves and eye protection. NOTE: Organic vapors are associated with the use of bleach. Adequate ventilation with fresh air and/or the use of a respirator equipped with an organic vapor acid gas cartridge may be required in order to prevent occupational exposures. The interior of the air handling unit shall be HEPA vacuumed to get the dust off the insulation and the condensate coil should be cleaned following the manufacturer s recommendations. Finally, a pleated filter should be installed. Hall Bathroom remove and dispose of the caulking and baseboard at the head end of the tub. Remove and properly dispose of a 1x1-foot section of gypsum board up from the floor at the base of the tub. The exposed wall cavity s wood framing should be HEPA vacuumed and wet wiped with a 20% bleach solution following the appropriate personal protective measures indicated above. Master Bathroom remove and properly dispose of the caulk along the tub at the floor. Remove the baseboard at each end of the tub and conduct a visual assessment of the exposed gypsum board. If suspect mold growth is observed, remove and properly dispose of a 1x1-foot section of gypsum board up from the floor at each end of the tub. The exposed wall cavities wood framing should be HEPA vacuumed and wet wiped with a 20% bleach solution following the appropriate personal protective measures indicated above. 10