CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Similar documents
CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

Centrum stavebního inženýrství a.s.

Classification report

Test Report: ICL/CR15/11/087

Additional Reaction to Fire Classification Report

TFI Report Classification

Additional reaction to fire classification report No H

Reaction to fire classification report No C-rev.1

CLASSIFICATION REPORT

Reaction to fire classification report No C

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Centrum stavebního inženýrství a.s.

Contact person Date Reference Page Richard Johansson P (2) Fire Research

New European Fire Testing Classification for Construction Products

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

Classification Report

DELTA Classification Report

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

Form: KSD-100:10 Page 1 of 3

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

Not all insulation is the same! from fire testing to real fires.

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

CLASSIFICATION IN REGARD OF REACTION TO FIRE according to EN :2007

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

BCTC CARPET TECHNICAL CENTRE

P.O. Box NL-2665 ZN Bleiswijk Brandpuntlaan Zuid 16 - NL-2665 NZ Bleiswijk The Netherlands

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

New European Cable Testing and Classification

TFI Report Classification

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Determination of the fire resistance according to EN : 2006 of vertical linear joints sealed with Henkel PATTEX FR55

REVIEW ON TWO PERFORMANCE-BASED TESTS FOR ASSESSING FLAME SPREAD IN HONG KONG

CPR: EUROCLASSIFICATION & TESTS FOR CABLES

MFPA Leipzig GmbH Prüf-, Überwachungs- und Zertifizierungsstelle für Baustoffe, Bauprodukte und Bausysteme

Harmonisation and equivalence of reaction-to-fire performance classification in Europe: a small-scale desk-based study

Analysis Report

CERTIFICATE OF APPROVAL No ME 5085

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Determination of the fire resistance according to EN of vertical linear joints sealed with Henkel PATTEX FR66

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

Information Data Sheet. Fire behavior of decorative high pressure laminates (HPL)

Facts about insulation and fires 29 October 2014

Analysis Report

Test Report: ICL/H18/9039 Rev 1

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

SUBJECT: ASSESSMENT FOR INTERNAL SURFACE FINISHES OF LIGHTBETON PANEL FOR COMPLIANCE WITH THE NEW ZEALAND BUILDING CODE(NZBC)

gent warn nfire No, 16209C Reaction to fire class ification report lntroduction Owner of the classification report

BS EN ISO : 2010

Abrasion Resistance of Fluoropolymer and polyester Coatings

Sýnishorn Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item

FAÇADE FIRE TESTS Towards a new European standard method

MEDIUM-DENSITY HOUSING # 7. Fire safety

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Development of a European approach to assess the fire performance of facades

ASSESSING THE FIRE PERFORMANCE OF ELECTRIC CABLES (FIPEC)

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

Certifikat och provningsprotokoll för art och 4511

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

BS EN ISO : 2010

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

IMO Resolution MSC 61(67): Annex 1: Part 2

EFFISUS BRAZE MEMBRANE

BS EN ISO : 2010


CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

Fire Testing of Foams

Üntel is ready for CPR

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Construction Products Regulation (CPR) and BS 6701

TFI Report Reaction to fire test

ISO INTERNATIONAL STANDARD

Report VNLF Test Report

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

FACADES AND FIRE The Essential Elements

Development of a Test Procedure for Sandwich Panels using ISO 9705 Philosophy

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

Guidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings

Fire Test Methods ASTM NFPA UL ISO IEC

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

Loss Prevention Standard

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

Construction Products Directive

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Test Report Reg.no 12.

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

Transcription:

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Sponsor Prepared by P.O. Box 118 NL-2394 ZG HAZERSWOUDE Efectis Nederland BV Lange Kleiweg 5 P.O. Box 1090 NL-2280 CB RIJSWIJK Notified Body no. 1234 Product name Avery MPI 2000 Avery MPI 2020 Classification report no 2012-Efectis-R9355o Issue number 1 Date of issue September 2012 Project number 2012355 This classification report consists of five pages and may only be used in its entirety.

Efectis Nederland report 2012-Efectis-R9355o September 2012 2 / 5 1. Introduction This classification report defines the classification assigned to Avery MPI 2000 and Avery MPI 2020 in accordance with the procedures given in EN 13501-1:2007+A1:2009. 2. Details of classified product 2.1 General The products, Avery MPI 2000 and Avery MPI 2020, will be used as a multipurpose vinyl, developed for use on various super wide format printers using solvent inks. 2.2 Product description The products are composed of: - Facefilm: - MPI 2000: 80 µm glossy white polymeric vinyl - MPI 2020: 80 µm matte white polymeric vinyl - Adhesive: permanent, acrylic based, 40 µm - Backing paper: two sides polyethylene coated kraft paper, 140 g/m 2 The product has a total thickness of 120 µm. 2.3 Manufacturer/Importer P.O. Box 118 NL-2394 ZG HAZERSWOUDE

Efectis Nederland report 2012-Efectis-R9355o September 2012 3 / 5 3. Standards, reports, results and criteria in support of this classification 3.1 Reports Name of Laboratories Name of sponsor Report ref. no. Test method Efectis Nederland BV 2012-Efectis-R9355m 2012-Efectis-R9355n EN ISO 11925-2:2010 EN 13823:2010 3.2 Test results Test method and test number EN-ISO 11925-2 surface flame impingement edge flame impingement EN 13823 Avery MPI 2000 Avery MPI 2020 Parameter No. tests Continuous parameter mean (m) Results Compliance with parameters Fs 150 mm [mm] 30-6 Ignition of filter paper Fs 150 mm [mm] 30-6 Ignition of filter paper FIGRA 0.2MJ [W/s] 11 - FIGRA 0.4MJ [W/s] 0 - THR 600s [MJ] 0.5 - LFS < edge SMOGRA [m 2 /s 2 ] 3 7.5 - TSP 600s [m 2 ] 44 - Flaming debris - flaming 10 s - flaming > 10 s Compliant FIGRA 0.2MJ [W/s] 0 - FIGRA 0.4MJ [W/s] 0 - THR 600s [MJ] 0.5 - LFS < edge SMOGRA [m 2 /s 2 ] 1 10.2 - TSP 600s [m 2 ] 46 - Flaming debris - flaming 10 s - flaming > 10 s Compliant

Efectis Nederland report 2012-Efectis-R9355o September 2012 4 / 5 3.3 Classification criteria Classification criteria of the Single Burning Item (SBI) test Class Fire Class Smoke FIGRA 0.2 MJ 120 W/s s1 SMOGRA 30 m 2 /s 2 A2 LFS < edge of the long wing specimen TSP THR 600s 7,5 MJ 600s 50 m 2 B FIGRA 0.2 MJ 120 W/s LFS < edge of the long wing specimen THR 600s 7,5 MJ s2 SMOGRA 180 m 2 /s 2 TSP 600s 200 m 2 FIGRA 0.4 MJ 250 W/s Class Droplets C LFS < edge of the long wing specimen d0 No flaming droplets/particles THR 600s 15 MJ d1 Flaming droplets/particles < 10 s D FIGRA 750 W/s d2 Not d0 or d1 4. Classification and field of application 4.1 Reference of classification This classification has been carried out in accordance with clause 11 of EN 13501-1:2007+ A1:2009. 4.2 Classification The product, Avery MPI 2000 and Avery MPI 2020, in relation to its reaction to fire behaviour is classified: The additional classification in relation to smoke production is: The additional classification in relation to flaming droplets / particles is: B s1 d0 Reaction to fire classification: B - s1, d0

Efectis Nederland report 2012-Efectis-R9355o September 2012 5 / 5 4.3 Field of application This classification is valid for the following product parameters: - Thickness 120 µm This classification is valid for the following end use applications: - Substrate non-combustible (class A1/A2 according to EN 13238:2010) - Air gap with air gap - Methods and means of fixing gluing using adhesive of product - Joints no joints 4.4 Duration of the validity of this classification report There are no limitations in time on the validity of this report. 5. Limitations This classification document does not represent type approval or certification of the product. C.C.M Steinhage B.Sc. Project leader reaction to fire A.J. Lock Project leader reaction to fire