Product Range Overview

Similar documents
Basic Unit with integrated Fuel / Air Ratio Control for Forced Draft Burners LMV Building Technologies

Basic unit with integrated air-fuel ratio control for forced draft burners

Basic unit with integrated fuel-air ratio control for forced draft burners LMV Building Technologies Division

LME75... Burner controls. Building Technologies

Burner controls. Building Technologies HVAC Products

Building Technologies

Burner Management System

Building Technologies Division

QRA10... QRA53... QRA55...

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

LGA... Gas Burner Controls. Building Technologies Division

Use. The burner controls are certified to EN 230 and EN 298.

QRA10... QRA53... QRA55...

Use. Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation.

Building Technologies Division

Power Flame Incorporated

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

QRA10... QRA53... QRA55...

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

Distributed By: M&M Control Service, Inc Building Technologies

QRA10... QRA53... QRA55...

Control Products & Systems OEM

Program module for burner control LME71.000

Burner Management System

Gas Burner Controls. Building Technologies HVAC Products

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

Burner Management System

Flame Safeguards LFE10. Building Technologies HVAC Products

Burner Controls. Building Technologies HVAC Products

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Control Products & Systems OEM

Flame Safeguards LFE10. Building Technologies HVAC Products

Infrared Flame Detectors

UV Flame Supervision System

Oil Burner Controls LMO24... LMO44...

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Oil Burner Controls LMO24... LMO44...

C Note! LGI16... Burner Controls. Building Technologies

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

LAE10 LFE10. Use. Series 02

Gas burner controls. Building Technologies

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Flame detector. Building Technologies Division Infrastructure & Cities Sector

Section 1 Overview. Introduction 1-1

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

Building Technologies Division Infrastructure & Cities Sector

RS /E-EV C01 SERIES

Blue-flame Detectors

RS /E-EV C01 SERIES

Infrared Flame Detectors

LOW NOx MODULATING GAS BURNERS

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

Flame detector. The QRA4.U is for use with the following types of burner control:

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

Display and operating unit for burner management systems, flame safeguards and burner controls

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

LFL Series Burner Flame Safeguard Control

Oil Burner Controls LOA3... Building Technologies Division

Description Control Box, type LOA 24 Control Box, type LOA 26 Control Box, type LMO Β2/C2 Control Box, type LMO B2 Control Box, type

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

Flame detector. The QRA4.U is for use with the following types of burner control:

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Honeywell SLATE ICM Platform

Interface and EOL Modules 8

Unitech Combustion.

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Revitalize Building Mechanical Systems (4619)

Control Products & Systems OEM

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

DKG 972. Gas Burner Safety Control. For 2-stage atmospheric gas burners

Oil Burner Controls LOA3... Building Technologies HVAC Products

Monitoring Devices 11/1

Gas burner automatic safety control MMI / 811.1

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Eclipse Trilogy Flame Safeguard Modulating Sequences

Burner control unit BCU 370

UV - flame detector dual fuel burners for intermittent burner operations

Complete burner management in a compact, affordable system

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies HVAC Products

PRELIMINARY EDITION

AUTOMATIC BURNER CONTROL SYSTEM SAFETY INFORMATION CONFORMITY

Complete Boiler Management in a Compact, Affordable System

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

Complete burner management in a compact, affordable system

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Chemical Processes in the Combustion

High Efficiency Burner Controls Beyond Efficiency June 7, 2016

Sola Hydronic Control. An Eco-Friendly Solution.

SGU 930 SGU 930i. Control box

Control Products & Systems OEM

Industrial Fire Detection

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

The product segments Heating, ventilation, air conditioning. Control Products & Systems OEM.

CHECKFIRE 210 Detection and Actuation System

Power Flame Incorporated

Transcription:

7 101 LME1 / LME2 / LME4 LME3 LME7 Product Range Overview LME LME are used for the startup and supervision of stage or modulating oil / gas burners in intermittent operation. Flame supervision takes place via an ionization probe or flame detector QRA with or without ancillary unit AGQ3; yellow-burning flames are supervised with photo resistive detectors QRB1 / QRB3 or yellow-flame detector QRB4, blue-burning flames with blueflame detector QRC. Applications in accordance with EN 267: Forced draft burners for liquid fuels Type-tested and approved in accordance with DIN EN 298 Applications in accordance with EN 676: Automatic forced draft burners for gaseous fuels Features of the LME: Undervoltage detection Air pressure supervision with function check of the air pressure switch during startup and operation Electrical remote lockout reset facility Multicolor indication of fault status messages and operating states Limitation of repetitions Accurate sequence times thanks to digital signal handling Controlled intermittent operation after 24 hours of continuous operation CC1Q7101en Building Technologies

Documentation The present documentation gives an overview of the product range. Target groups Sales engineers Internal staff Burner specialists 2/13

Functions Basic applications Single-stage forced draft burners 2-stage forced draft burners Atmospheric burners, single stage, with / without auxiliary fan Atmospheric burners, 2 stage, with / without auxiliary fan Control of ignition valve Air damper control Controlled air damper control Temperature controller in mains supply line Temperature controller in control loop Air pressure supervision with function check of air pressure switch during startup and operation LME11 LME21 LME22 LME23 LME39.1 LME39.4 LME41 LME44 Status input CPI Modulating burner via PWM fan in the pneumatic ratio control Modulating burner via actuator in the mechanical or pneumatic ratio control General Undervoltage detection Electrical remote lockout reset facility Multicolor indication of operating state and fault status messages Accurate sequence times thanks to digital signal handling Controlled intermittent operation Limitation of repetitions Unit parameter adjustable Optional: Analog input for load controller setpoint setting Optional: 3 x 7 segment display for faults, operating notifications and parameter display Optional: Program sequence in the separate program module Flame detectors for intermittent operation Ionization probe UV flame detector QRA with AGQ3 (only for AC 230 V) UV flame detector QRA Photo resistive flame detector QRB1 / QRB3 Yellow flame detector QRB4 Blue-flame detector QRC Valve proving system LDU11 Pressures switch valve proving Communication interfaces BCI for AZL2 or OCI410 OCI400 for optical interface OCI410 BCI / USB interface converter PC Windows software ACS410 for visualization PC Windows software ACS410 for parameter settings Display 7-segment display and operating unit AZL21 7-segment display and operating unit AZL23 3-colored LED, build-in LME7 3/13

Product range overview Display and operating units AZL21... AZL23... IP40 IP54 4/13 Building Technologies Product Range Overview CC1Q7101en

Presentation of products Burner control LME1 / LME2 / LME4 Gas burner controls for supervision of single- or 2-stage forced draft gas burners and atmospheric burners of small to medium capacity, intermittent operation. LME3 Parameterized gas burner controls for the supervision of 1- or 2-stage forced draft gas burners and atmospheric burners of small to medium capacity (typically up to 350 kw), in intermittent operation. LME7 Parameterized burner controls for the supervision of stage or modulating oil / forced draft gas burners and atmospheric burners of medium to large capacity, in intermittent operation. With controlled air damper control. Program module Connection accessories for small burner controls PME7 Program module for LME7. With program sequences for oil or gas burners for LME7 basic unit. AGK11 (not for LME39) Article no.: BPZ:AGK11 Plug-in base for connecting small burner controls to the burner plant. AGK11.6 Article no.: BPZ:AGK11.6 Plug-in base (Grey) for connecting LME39 to the burner plant. AGK66 Article no.: BPZ:AGK66 Cable holder for use with AGK11 plug-in base. AGK65 Article no.: BPZ:AGK65 Cable holder for use with AGK11 plug-in base. 5/13

Connector sets for LME7 AGG3.710 Article no.: BPZ:AGG3.710 Connector set complete for LME7 RAST5 and RAST3.5 Single packs Example: X5-03 AGG3.720 Article no.: BPZ:AGG3.720 10 standard connector sets complete for LME7 RAST5 and RAST3.5 Single packs The several connectors are delivered into bags to 10 pieces each as a unit AGG9.xxx The individual connectors are supplied in packaging units of 200 pieces each. Example: Article no. Type Type of connector Terminal BPZ:AGG9.201 AGG9.201 RAST5 X2-09B BPZ:AGG9.203 AGG9.203 RAST5 X3-02 BPZ:AGG9.209 AGG9.209 RAST5 X10-06 BPZ:AGG9.301 AGG9.301 RAST5 X2-01 BPZ:AGG9.302 AGG9.302 RAST5 X2-03 BPZ:AGG9.304 AGG9.304 RAST5 X4-02 BPZ:AGG9.306 AGG9.306 RAST5 X5-01 BPZ:AGG9.309 AGG9.309 RAST5 X6-03 BPZ:AGG9.310 AGG9.310 RAST5 X7-01 BPZ:AGG9.311 AGG9.311 RAST5 X7-02 BPZ:AGG9.313 AGG9.313 RAST5 X9-04 BPZ:AGG9.401 AGG9.401 RAST5 X2-02 BPZ:AGG9.403 AGG9.403 RAST5 X5-03 BPZ:AGG9.405 AGG9.405 RAST5 X7-04 BPZ:AGG9.501 AGG9.501 RAST5 X3-04 BPZ:AGG9.504 AGG9.504 RAST5 X10-05 BPZ:AGG9.601 AGG9.601 RAST5 X2-09A BPZ:AGG9.822 AGG9.822 RAST3,5 2-pole BPZ:AGG9.831 AGG9.831 RAST3,5 3-pole BPZ:AGG9.841 AGG9.841 RAST3,5 4-pole 6/13

Flame detectors QRA2 Flame detector for use with Siemens burner controls, for the supervision of gas flames, yellow- / blue-burning oil flames and for ignition spark proving. Plastic insulated housing, metalized to prevent static charging caused by the air flow from the fan. For direct mounting on the burner. Delivery optional with / without flange and clamp. QRA4 Flame detector for use with Siemens burner controls, for the supervision of gas flames, yellow- / blue-burning oil flames and for ignition spark proving. QRA10 Flame detector for use with Siemens burner controls, for supervision of gas flames, yellow- / blue-burning oil flames and for ignition spark proving. Die-cast aluminum housing with a 1 in. mounting coupling and connection facility for cooling air. The housing of this detector has a bayonet fitting which allows it to be secured either directly to the 1 in. mounting coupling or to the AGG06. The 1 in. mounting coupling can be screwed to a viewing tube or to the AGG07. The Pg cable gland can be removed and replaced, if some other detector cable shall be used. QRB1 Photo resistive detector for use with Siemens burner controls, for the supervision of oil flames in the visible light spectrum. The QRB1 are used primarily in connection with burner controls for burners of small capacity. QRB3 Photo resistive detector for use with Siemens burner controls, for the supervision of oil flames in the visible light spectrum. The QRB3 are used primarily in connection with burner controls for burners of small capacity. QRB4 Yellow-flame detector for use with Siemens burner controls, for the supervision of oil flames in the visible light spectrum. The QRB4 is used in connection with oil burner controls in intermittent operation. QRC Blue-flame detector for use with Siemens burner controls, for the supervision of blue- and yellow-burning oil or gas flames. QRC is used especially in connection with burner controls for burners of small capacity. Frontal illumination: Lateral illumination: 7/13

Service tools OCI400 Article no.: BPZ:OCI400 Optical interface between burner control and PC. Facilitates viewing and recording setting parameters on site in connection with the ACS410 software. OCI410 Article no.: BPZ:OCI410 BC interface module between burner control and PC. Facilitates viewing, handling and recording setting parameters on site in connection with the ACS410 software. ACS410 Article no.: BPZ:ACS410 PC software for setting the parameters and for visualizing the burner controls. 8/13

Actuators SQN3 / SQN4 Electromotoric actuators for use with air dampers and control valves of oil or gas burners of small to medium capacity. - Impact-proof and heat-resistant plastic housing - Screw terminals for the electrical connections - Maintenance-free gear train, which can be disengaged - Internal and external position indication - Easy-to-adjust end and auxiliary switches for setting the switching points Holding torque: - SQN3 - SQN4 Running time: - SQN3 - SQN4 Direction of rotation: - SQN30 - SQN31 / SQN41 0.8...3 Nm 6 Nm 4.5...30 s 120 s counterclockwise clockwise SQN7 Electromotoric actuators for air dampers and control valves of oil and gas burners of small to medium capacity. - Impact-proof and heat-resistant plastic housings - Screw terminals for the electrical connections - Maintenance-free gear train, which can be disengaged - Internal position indication - Easy-to-adjust end and auxiliary switches for adjusting the switching points - Integrated electronic circuits - With synchronous motor Holding torque: - SQN70 / SQN71 / SQN75 - SQN74 Running time: - SQN70 / SQN71 / SQN75 - SQN74 Direction of rotation: - SQN70 / SQN74 - SQN71 / SQN75 0.7...1.3 Nm 0.7 Nm 4...30 s 4 s counterclockwise clockwise 9/13

Actuators SQN9 Electromotoric actuators for air dampers and control valves of oil and gas burners of small to medium capacity. - Impact-proof and heat-resistant plastic housings - Screw terminals for the electrical connections - Maintenance-free gear train, which can be disengaged - Internal position indication - Easy-to-adjust end and auxiliary switches for adjusting the switching points - Integrated electronic circuits Holding torque: Running time: Direction of rotation: - SQN90 - SQN91 0.8...2.4 Nm 4...24 s counterclockwise clockwise SQM1 / SQM2 The reversible electromotoric actuators SQM range are for use in connection with controllers or switching devices equipped with changeover contacts. Holding torque: - SQM1 - SQM2 Running time: - SQM1 - SQM2 Direction of rotation: 4...15 Nm 12 Nm 14...100 s 29...66 s clockwise or counterclockwise rotation SQM40 / SQM41 The actuators are suited for driving flow control valves, butterfly valves, dampers or for use on other applications that require rotary motion. Areas of application are oil and gas burners of medium to larger capacity as well as thermal process plants. Holding torque: Up to 10 Nm Running time: Direction of rotation: 15 s and 30 s clockwise or counterclockwise rotation 10/13

Actuators SQM5 The reversible electromotoric actuators SQM5 are used to drive air or gas dampers of oil and gas burners of medium to large capacity - With 1 or 2 drive shaft ends; drive shafts can be exchanged and are available as separate items - Can be equipped with electronic modules for control and position feedback via steady signals - Internal and external position indication - Drive shaft and cam shaft can be separately disengaged - Choice of UL-listed types for use in the U.S. and Canada - Supplementary Data Sheets, refer to N7921 and N7922 Holding torque: - SQM50 - SQM53 / SQM54 - SQM56 Running time: - SQM50 - SQM53 - SQM54 - SQM56 Direction of rotation: 10...15 Nm 20...25 Nm 30...40 Nm 10...87 s 30...43 s 30...65 s 60...87 s Facing the gear train side: counterclockwise or clockwise (selectable) Delivery: counterclockwise Display and operating units AZL21.00A9 Article no.: BPZ:AZL21.00A9 Display and operating unit, detached, choice of mounting methods, 8-digit LCD, 5 buttons, BCI for LME39 / LME7, degree of protection IP40. AZL23.00A9 Article no.: BPZ:AZL23.00A9 Display and operating unit, detached, choice of mounting methods, 8-digit LCD, 5 buttons, BCI for LME39 / LME7, degree of protection IP54. 7-segment display (optional) Built-in in the LME7 and 3 other buttons for operation in connection with 3 x 7-segment display. 11/13

Accessories AGK20 Article no.: BPZ:AGK20 Extension of lockout reset button. AGV50.100 Article no.: BPZ:AGV50.100 Signal cable for AZL2, with RJ11 connector, cable length 1 m, pack of 10. AGV50.300 Article no.: BPZ:AGV50.300 Signal cable for AZL2, with RJ11 connector, cable length 3 m, pack of 10. ARC466890660 Article no.: BPZ:ARC466890660 RC unit for ionization current supervision in networks with non-earthed neutral conductor. AGK25 Article no.: BPZ:AGK25 PTC resistor (AC 230 V) as a burden for terminal 3 (for burners without fan motor, such as atmospheric gas burners). AGQ3 Ancillary unit for UV supervision, can be fitted under the plug-in base. AGQ3.1A27: Cable length 500 mm Article no.: BPZ:AGQ3.1A27 AGQ3.2A27: Cable length 300 mm Article no.: BPZ:AGQ3.2A27 KF8872 (not for LME39) Article no.: BPZ:KF8872 Service adapter for checking the functions of burner controls on the plant. Function checks via control lamps. Detector current measurements via 4 mm dia. jacks. Β Note! When there is no load on the output terminals, the respective control lamp might light up. LDU11 (only LME22 and LME39.1) The valve proving system for monitoring the leakage of the shutoff valves for gas burners and gas devices. In the event of inadmissible leakage, the system prevents the burner from starting up. See Data Sheet N7696. QPLx5 The pressure switches are used for monitoring gas or air pressures. When the pressure falls below or exceeds the adjusted switching point, the respective electrical circuit will be opened or changes over. 12/13

Available documentation Type reference (ASN) Title Documentation no. ACS410 Software CC1J7352 AGG3 Connection set C7105 (74 319 0642 0) AGG9 Connection set --- AGK11 Plug-in base CC1N7201 AGK20 Extension of lockout reset button --- AGK25 PTC resistor --- AGK65 Cable holder CC1N7201 AGK66 Cable holder CC1N7201 AGQ3 Ancillary unit --- AGV50.100 Signal cable --- AGV50.300 Signal cable --- ARC466890660 RC unit --- AZL21 Display and operating units CC1N7542 AZL23 Display and operating units CC1N7542 KF8872 Service adapter --- LDU11 Valve proving system CC1N7696 LME11 Burner control CC1N7101 LME21 Burner control CC1N7101 LME23 Burner control CC1N7101 LME39 Burner control CC1N7106 LME41 Burner control CC1N7101 LME44 Burner control CC1N7101 LME7 Burner control CC1P7105 OCI400 Optical interface CC1N7614 OCI410 BC interface module CC1N7615 PME7 Program module CC1P7105 QPLx5 Pressure switch CC1N7221 QRA2 Flame detector CC1N7712 QRA4 Flame detector CC1N7711 QRA10 Flame detector CC1N7712 QRB1 Photo resistive flame detector CC1N7716 QRB3 Photo resistive flame detector CC1N7716 QRB4 Yellow flame detector CC1N7720 QRC Blue flame detector CC1N7714 SQN3 Actuators CC1N7808 SQN4 Actuators CC1N7808 SQN7 Actuators CC1N7804 SQN9 Actuators CC1N7806 SQM1 Actuators CC1N7812 SQM2 Actuators CC1N7812 SQM40 / SQM41 Actuators CC1N7817 SQM5 Actuators CC1N7815 2018 Siemens AG Building Technologies, Berliner Ring 23, D-76437 Rastatt Subject to change! 13/13