User s Manual YTA610 and YTA710 NEPSI Certification

Similar documents
YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3.

OPTIBAR DP 7060 Supplementary Instructions

EXPLOSION PROTECTION

OPTIWAVE X500 Supplementary Instructions

Rosemount 8800D Series Vortex Flowmeter. Quick Start Guide , Rev FE October 2018

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Rosemount 8600 Series Vortex Flowmeter. Quick Start Guide , Rev EB April 2018

Certificate of Compliance

Operating Instructions Edition 02/2007

Rosemount 248 Temperature Transmitter

Annubar Flowmeter Series

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Certificate of Compliance

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Rosemount 644 Temperature Transmitter

EU DECLARATION OF CONFORMITY

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Certificate of Compliance

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Certificate of Compliance

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Technical Data. General specifications. Rated operating distance s n 5 mm

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Inductive slot sensor

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

SET Installation and Operating Instructions. Level switch for one sensor

Rosemount 3144P Rosemount 3144P Temperature Transmitter

IECEx Certificate of Conformity

Rosemount 848T High Density Temperature Measurement Family

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

4) Intrinsic Safety Certification

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol

Certificate of Compliance

VERSAFLOW VORTEX Supplementary instructions

ATEX Explained A brief Introduction

OilSET-1000 (12 VDC)

General Specifications

Rosemount 248 Temperature Transmitter

SET-2000 Oil/Sludge 12 VDC

Rosemount 848T FOUNDATION Fieldbus High Density Temperature Transmitter

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

INSTRUCTION MANUAL (ATEX)

Brooks Models MT3809G and MT3810G Metal Tube Variable Area Flowmeters

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

Quick Start Guide , Rev HA January Rosemount 248 Temperature Transmitter

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 248 Temperature Transmitter

Safety Instructions Omnigrad S TR/TC6x

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Rosemount 644H Temperature Transmitters

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Rosemount 3051 Pressure Transmitter

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 702 Wireless Discrete Transmitter

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

OPTIBAR P 1010/2010 C Supplementary instructions

IECEx Certificate of Conformity

Safety instructions VEGABAR 81, 82, 83, 86, 87

Rosemount 752 Fieldbus Remote Indicator

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Rosemount 2090F Hygienic Pressure Transmitter

Technical Data. Dimensions

Installationsmanual GWSL1100/2100, GWML3100

IECEx Certificate of Conformity

国家级仪器仪表防爆安全监督检验站 National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation (GYJ ) (Attachment Ⅰ) Attachm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

SET-2000 Hi Level/Oil

Quick Start Guide For the

IECEx Certificate of Conformity

Rosemount 2051G Pressure Transmitter

Centurion Guided Radar HAWK CGR SERIES

IECEx Certificate of Conformity

Rosemount 8800D Series Vortex Flowmeter

MT3809G Series. Metal Tube Variable Area Flowmeters. Overview. Product Description. Variable Area

Rosemount 3144P Temperature Transmitters with FOUNDATION Fieldbus Protocol. Quick Start Guide , Rev DA June 2016

MT5000 Guided Wave Radar Level Transmitter. State-of-the-art loop powered, 4-20 ma output guided wave radar transmitter for liquid level applications

Rosemount 2051 Pressure Transmitter and Rosemount 2051CF Series Flowmeter

Rosemount 644H Temperature Transmitters

Rosemount 3490 Series

Ar-Mite TM Low Flow Armored Flowmeter

Technical Data. Dimensions

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Transcription:

User s Manual YTA60 and YTA70 NEPSI Certification [Option code: /NS, /NS5 and /NF] st Edition

. INTRODUCTION Thank you for purchasing the YTA60 and YTA70 Temperature transmitters. This manual contains important note and handling cautions for the YTA Temperature Transmitters with NEPSI certification, option code /NS, NS5 and /NF. Refer to the following user s manuals for standard specifications, functions, handling cautions, and operations, etc. Table. List of User s Manuals Title YTA60 and YTA70 Temperature Transmitters (Hardware) YTA60 and YTA70 Temperature Transmitter (HART Protocol) YTA60 and YTA70 Temperature Transmitter (Fieldbus Communication). NEPSI Certification () Technical Data a) NEPSI Intrinsically Safe Type Caution for NEPSI Intrinsically safe type Document No. IM 0C50G0-0EN IM 0C50T0-0EN IM 0C50T0-0EN Note. Certification information -0mA type Model YTA60 and YTA70 with /NS Certificate No.: GYJ6.X Applicable Standard: GB86.-00, GB86.-00, GB86.0-00 Type of Protection and Marking code: Ex ia IIC T/T5 Ga Temperature Class: T, T5 Ambient Temperature: 0 to 70 C for T, 0 to 50 C for T5 Enclosure: IP66/IP67 in accordance with only IEC 6059 Electrical Data [Supply/Output circuit] Ii = 00 ma Pi =.0 W Ci = nf [Sensor circuit] Po = 5 mw Co = 0 μf st Edition: Dec. 06 (YK) All Rights Reserved, Copyright 06, Yokogawa Electric Corporation Dielectric strength: 500 V a.c.r.m.s., min [, -, C,,,,, 5] to Earth terminal [, -, C] to [,,,, 5] Fieldbus type Model YTA60 and YTA70 with /NS5 Certificate No.: GYJ6.X Applicable Standard: GB86.-00, GB86.-00, GB86.0-00 Type of Protection and Marking Code: Ex ia IIC T Ga Temperature Class: T Ambient Temperature : 55 to 60 C for T Enclosure: IP66/IP67 in accordance with only IEC 6059 FISCO field Device Electrical parameters [Supply/output circuit] Ii = 00 ma Pi =. W Ci =. nf [Sensor input circuit] Po = 5 mw Co = 0 μf Dielectric strength: 500 V a.c.r.m.s., min [, -,,,,, 5] to Earth terminal [, -] to [,,,, 5] Note. Special condition for safe use WARNING When the enclosure of the Temperature Transmitter is made of aluminum alloy, if it is mounted in an area where the use of EPL Ga equipment is required, it must be installed such that, even in the event of rare incidents, an ignition source due to impact and/or friction sparks is excluded Precautions shall be taken to minimize the risk from electrostatic discharge of the painted parts. The dielectric strength of 500V r.m.s between the intrinsically safe circuit and the enclosure of the Temperature Transmitter is limited, only by the removable surge absorber F90AR. When the surge absorber is used, the earthing facility should be in accordance with Clause.. of GB86.5-000.

WARNING: ELECTROSTATIC CHARGE MAY CAUSE AN EXPLOSION HAZARD. AVOID ANY ACTIONS THAT CAUSE THE GENERATION OF ELECTROSTATIC CHARGE, SUCH AS RUBBING WITH A DRY CLOTH ON COATING FACE OF THE PRODUCT. Note. Control Drawing -0mA Non- Temperature Transmitter Intrinsically Safe apparatus or Simple apparatus Sensor Input 5 Supply/Output C Associated Apparatus Sensor lnput: Po = 5 mw Co = 0 μf Model YTAxxx - J or - D Supply/Output: Ii = 00 ma Pi =.0 W Ci = nf F0.ai Fieldbus Non- Terminator Terminator Associated Apparatus Field Device Field Device Linear source of FISCO power supply Intrinsically Safe apparatus or Simple apparatus Model YTAxxx - F or - G Temperature Transmitter Sensor Input Supply/Output 5 Sensor lnput: Po = 5 mw Co = 0 μf Model YTAxxx - F or - G Supply/Output: Ii = 00 ma Pi =. W Ci =. nf FISCO field device F0.ai

Note. Conditions for safe use Cable entry should be applied when installation in hazardous location and redundant holes for cable entry should be closed by blanking elements. The IP code should be IP66/IP67. This product should be used in explosive gas atmospheres together with associated apparatus, follow the instruction manual of this product and the associated apparatus when connecting the wiring. Connect the wiring terminals correctly. It is forbidden to change the configuration except for the removable surge arrester, to ensure the equipment s explosion protection performance. When installation, use and maintenance of Temperature Transmitter, observe following standards GB86. -0 Explosive atmospheres - Part : Equipment repair, overhaul and reclamation GB86.5-000 Electrical apparatus for explosive gas atmospheres Part 5: Electrical installations in hazardous area (other than mines) GB86.6-006 Electrical apparatus for explosive gas atmospheres Part 6: Inspection and maintenance of electrical installation (other than mines) GB86.8-00 Explosive atmospheres - Part 8: Intrinsically safe system GB5057-0 Code for construction and acceptance of electric equipment on fire and explosion hazard electrical equipment installation engineering. b) NEPSI Flameproof Type Caution for NEPSI Flameproof Type Note. Model YTA60/NF and YTA70/NF Applicable Standard: GB86.-00, GB86.-00, GB76.-0, GB76.5-0 Certificate No.: GYJ6.96X Type of Protection and Marking Code: Ex d IIC T5/T6 Gb, Ex td A IP66/IP67 T70 C/T90 C Temperature Class: T5, T6 Ambient Temperature for Gas Atmospheres: 0 to 80 C for T5, 0 to 75 C for T6 Ambient Temperature for Dust Atmospheres: 0 to 65 C for T70 C, 0 to 80 C for T90 C Enclosure: IP66/IP67 Note. Electrical Data Supply voltage : V dc max. ( to 0 ma type) : V dc max. (Fieldbus type) Output signal : to 0 ma : ma dc max. (Fieldbus type) Note. Installation All wiring shall comply with local installation Requirements. Note. Operation Keep strictly the WARNING on the label on the transmitter. WARNING: AFTER DE- ENERGIZING, DELAY 0 MINUTES BEFORE OPENING. WHEN THE AMBIENT TEMP. 70 C, USE THE HEAT- RESISTING CABLE & CABLE GLANDS 90 C. POTENTIAL ELECTROSTATIC CHARGING HAZARD. -SEEUSER S MANUAL BEFORE USE. Take care not to generate mechanical spark when access to the instrument and peripheral devices in hazardous location. Note 5. Conditions for safe use The external earth connection facility shall be connected reliably. M0X.5 or /-NPT thread type cable entry, adapters and/or blanking elements, certified by notified body with type of protection Ex d IIC Gb in accordance with GB86.-00 and GB86.-00, should be applied when installation in explosive gas atmosphere. M0X.5 or /-NPT thread type cable entry, adapters and/or blanking elements, certified by notified body with type of protection Ex td A in accordance with GB76.-0 and GB76.5-0, should be applied when installation in combustible dust atmosphere. At least IP6X should be guaranteed after the assembly. Forbid end user to change the configuration to ensure the equipment s explosion protection performance.

When installation, use and maintenance of Temperature Transmitter, observe following standards GB86.-0 Explosive atmospheres - Part : Equipment repair, overhaul and reclamation GB86.5-000 Electrical apparatus for explosive gas atmospheres Part 5: Electrical installations in hazardous area (other than mines) GB86.6-006 Electrical apparatus for explosive gas atmospheres Part6: Inspection and maintenance of electrical installation (other than mines) GB5057-0 Code for construction and acceptance of electric equipment on fire and explosion hazard electrical equipment installation engineering GB5577-007 Safety regulations for dust explosion prevention and protection GB76.-00 Electrical apparatus for use in the presence of combustible dust-part : Selection and installation Revision Record Dec. 06 st edition New Publication. Note 6. Special condition for safe use WARNING The suffix X placed after the certificate number indicates that this product is subject to special conditions for safe use: The values of the flamepaths are different from the standard values given in GB86.- 00. Repair of the equipment is only allowed when done by the manufacturer or authorized representative. When used in hazardous location, electrostatic discharge should be avoided. () Electrical connection The type of electrical connection is stamped near the electrical connection port according to the following marking. Screw Size ISO M0.5 female ANSI / NPT female Marking M N Location of the marking F0.ai