DMFPM-2R MULTIFUNCTIONAL

Similar documents
RSMFM-2R MULTIFUNCTIONAL

Snifter ATEX22 VERSION. User Manual. Distributor

Sintrol Snifter A2 EX. Manual. Version 1.2.3

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

Carbon Monoxide Transmitter

Refrigerated Incubator Model and Operating Instructions

Networkable Fan Coil Controller Specification and Installation Instructions

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

Snifter. User Manual. Distributor

FLÄkT WOOdS BuILT-ON FrEQuENCY CONVErTEr CENTRIFLOW 3D PLUG FAN WITH PERMANENT MAGNET AND ASYNCHRONOUS MOTOR

I/O logger box. User manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT!

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Sintrol Snifter A1+ Manual. Version 1.2.2

P2267 NETWORK INTERFACE

CHILLGARD M-100. Refrigerant Sensor. Operating Manual. Order No.: /02

PTE0705 Electric Fence Monitor

Instructions OJ EC-Controller (Translation of the original) BA-ESR_OJ-EC /2013

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

LC1350 Level Controller

RS485 MODBUS Module 8AI

FLT93 Installation, Operation and Troubleshooting Guide

S304 and S305 Dust Emission Monitors. User Manual. Distributor

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Instructions for the BASIC BCRW Fan, Sizes General

BC3250. Blowdown Controller

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

Interface Module RS232/485. INTERFACE MODULE RS232/485 Instruction Manual 03-INT-02-17

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Duct and Rough Service Carbon Monoxide Sensor

Installation and maintenance instructions for cabin units type vertical IDAC (V50)

Installation, Operation and Maintenance Manual

Knürr RMS Compact II. Knürr RMS Compact II 2.81

2017 MacroAir Technologies Toll Free: Fax:

Datasheet: K-22 LO Sensor

Pump-Down Controller MODEL 4052

ModBus DE-1 INSTALLATION AND USER MANUAL

Gas Leak Detection Alarm

! "! # Please read these installation and operating instructions completely and carefully before starting.

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

mtc001 Thermocouple Converter

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Pump-Up Controller MODEL 4062

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PowerLogic Branch Circuit Power Meter (BCPM)

1600 Gas Controller. User s Manual. Industrial Scientific Corporation. Version 3.2 September 1, 2006

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Outside Humidity and Temperature Sensor

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

OPTISENS TUR 2000 Technical Datasheet

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Built-on speed controller for GMPM plug fan with permanent magnet motor

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

Danfoss gas detection units

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

QFM21... Duct sensors. Symaro. for relative humidity and temperature

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

VA301C CONTROLLER WITH BACnet OPTION

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

Warranty Registration

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

tcu.z Commercial Programmable Thermostat Installation Instructions

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION

Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Dusty / Dusty Ex Low-Cost Broken Bag Detection

Duct Temperature Sensors

CLEANROOM MONITOR CR3A Network - Installation Instructions

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

DAP III Zone Master User s Guide

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

Product waste disposal - Protection of the environment:

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Installation and user manual for the BiWire / Conventional Repeater Panel

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

WRF04 CO 2 RS485 Modbus

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Safety, Installation, and Operation Manual

Hot Surface Ignition (HSI) System Booklet

Transcription:

Mounting and operating instructions

Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND CONNECTIONS 5 MOUNTING & OPERATING INSTRUCTIONS IN STEPS 6 OPERATING INSTRUCTIONS 8 VERIFICATION OF INSTALLATION INSTRUCTIONS 9 MODBUS REGISTER MAPS 9 TRANSPORT AND STORAGE 11 WARRANTY AND RESTRICTIONS 11 MAINTENANCE 11 MIW--EN-000-11 / 04 / 2018 www.sentera.eu 2-11

SAFETY AND PRECAUTIONS Read all the information, the datasheet, mounting and operating instructions and study the wiring and connection diagram before working with the product. For personal and equipment safety, and for optimum product performance, make sure you entirely understand the contents before installing, using, or maintaining this product. For safety and licensing (CE) reasons, unauthorised conversion and / or modifications of the product are inadmissible. The product should not be exposed to abnormal conditions, such as: extreme temperatures, direct sunlight or vibrations. Long-term exposure to chemical vapours in high concentration can affect the product performance. Make sure the work environment is as dry as possible; avoid condensation. All installations shall comply with local health and safety regulations and local electrical standards and approved codes. This product can only be installed by an engineer or a technician who has expert knowledge of the product and safety precautions. Avoid contacts with energised electrical parts; always treat the product as if it is live. Always disconnect the power supply before connecting, servicing or repairing the product. Always verify that you apply appropriate power supply to the product and use appropriate wire size and characteristics. Make sure that all the screws and nuts are well tightened and fuses (if any) are fitted well. Recycling of equipment and packaging should be taken into consideration and these should be disposed of in accordance with local and national legislation / regulations. In case there are any questions that are not answered, please contact your technical support or consult a professional. MIW--EN-000-11 / 04 / 2018 www.sentera.eu 3-11

PRODUCT DESCRIPTION The series are multifunctional duct controllers featuring adjustable temperature, relative humidity and CO 2 setpoints. They are Power over Modbus supplied and all parameters and the output are accessible via Modbus RTU. ARTICLE CODES Code Supply Connection Power over Modbus, 24 VDC RJ45 INTENDED AREA OF USE Maintenance and control of temperature, relative humidity and CO 2 levels in HVAC ducts TECHNICAL DATA Selectable temperature, relative humidity and CO 2 setpoints Selectable temperature : 0 50 C Selectable relative humidity : 5 85 % Selectable CO 2 : 0 2.000 ppm Accuracy: ±0,4 C (0 50 C); ±3 % rh (5 85 % rh); ±30 ppm CO 2 (0 2.000 ppm CO 2 ), depending on the selected parameter Removable sensor element for easy calibration and verification Compatible with SSCDM - Sentera Sensor Calibration Device Option for uploading a new firmware via Modbus RTU Minimum airflow velocity required: 1 m/s Enclosure and probe material: ASA, grey (RAL9002) Protection standard: Enclosure: IP54, Probe: IP20 Operating ambient conditions: temperature: 0 50 C rel. humidity: 5 85 % rh, (non-condensing) Storage temperature: -10 60 C STANDARDS EMC Directive 2014/30/EC: EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements EN 61326-2-3:2013 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning WEEE Directive 2012/19/EC RoHs Directive 2011/65/EC MIW--EN-000-11 / 04 / 2018 www.sentera.eu 4-11

OPERATIONAL DIAGRAMS Input register 11 [%] T [ C] rh [%] CO 2 [ppm] 100 Max Max 60 40 Min Min 0 0 T min T Max 5 rh min rh Max 0 CO 2 min CO 2 Max 50 85 2.000 WIRING AND CONNECTIONS Pins 1 & 2 Pins 3 & 4 Pins 5 & 6 Pins 7 & 8 24 VDC A /B GND Supply voltage (24 VDC) RS485, Modbus RTU communication, signal A RS485, Modbus RTU communication, signal /B Supply voltage, ground 24 VDC A /B GND 1 2 3 4 5 6 7 8 RJ45 1 2 3 4 5 6 7 8 MIW--EN-000-11 / 04 / 2018 www.sentera.eu 5-11

MOUNTING & OPERATING INSTRUCTIONS IN STEPS Before you start mounting the duct controller, read carefully Safety and Precautions. Follow these steps: 1. When preparing to mount the, bear in mind that the unit itself must be installed onto the outer surface of the duct both via fixing the flexible flange or directly the unit enclosure, while the probe must be inserted inside the duct, see Fig. 1 and Fig. 2 below. Fig. 1 Mounting dimensions With flange Without flange 50 Ø 12 2x Ø 5 60 18,5 285 42,3 86,8 100 70 4x Ø 4,4 105 80 66 34,5 Fig. 2 Mounting position Correct Incorrect AIR FLOW AIR FLOW MIW--EN-000-11 / 04 / 2018 www.sentera.eu 6-11

2. Having selected the appropriate mounting location, proceed with the following steps: 2.1 Drill a Ø 13 mm hole into the duct and insert the probe. Apply an air-tight sealing between probe and duct. 2.2 Fix the flange onto the duct outer surface using the self-drilling screws delivered with the unit. If you do not intend to use the flange, insert the tube and fix the enclosure onto the duct. Mind the airflow direction (see Fig. 2 and Fig. 3). Fig. 3 Mounting requirements 7,5*D (1) 3,5*D (1) D = Duct diameter ATTENTION Installation requirements: The must not be installed in turbulent air zones. Ensure sufficiently long settling zones upstream and downstream of the tapping point. A settling zone consists of a straight section of pipe or duct with no obstructions. Avoid installation near filters, cooling coils, fans, etc. The sensor will achieve the optimal result when the measurement is taken at least 7,5 duct diameters downstream and at least 3 duct diameters upstream from any turns or flow obstructions. ATTENTION Installation of the unit near high EMI-emitting devices may lead to faulty measurements. Use shielded wiring in areas with high EMI. ATTENTION Keep at least 15 cm distance between the sensor lines and the 230 VAC power lines. 2.3 Install the tube at the desired depth and, in case you use the flange, fix it via the plastic white screw in the flexible flange. 2.4 Unscrew the cover of the unit to remove it and insert the connecting cable through the cable gland of the unit. 2.5 Crimp the RJ45 cable and plug it into the socket, see Fig. 4 and section Wiring and connections above. Fig. 4 Wiring and connections 24 VDC A /B GND 1 2 3 4 5 6 7 8 RJ45 1 2 3 4 5 6 7 8 MIW--EN-000-11 / 04 / 2018 www.sentera.eu 7-11

3. Customise the factory settings to the desired ones via the 3SModbus software or Sensistant (if necessary). For the default factory setting see Table Modbus register maps. Optional settings If your unit is the first or the last unit on the Modbus RTU network (see Example 1 and Example 2), enable the NBT resistor via 3SModbus or Sensistant (Holding Register 30). If your device is not an end device, leave the NBT disabled (default Modbus setting). Example 1 Example 2 Slave 1 NBT NBT RX ТX Master NBT RX ТX NBT Slave 2 Master NBT Slave n Slave 1 Slave 2 Slave n 4. Close the enclosure and fix the cover. 5. Switch on the power supply. CAUTION Do not expose to direct sunlight! OPERATING INSTRUCTIONS Calibration procedure: No relative humidity and temperature sensor calibration is necessary. By default, the CO 2 sensor element is self-calibrating. Optionally, the CO 2 sensor element can be calibrated and verified manually via SSCDM. For this purpose, the CO 2 sensor element is removable. More information is available in the SSCDM datasheet and mounting and operating instructions. Bootloader Thanks to the bootloader functionality, the sensor firmware can be updated via Modbus RTU communication. To enter Boot mode, put a jumper onto pins 3 and 4 of the P1 header and restart the power supply (see Fig. 5). Once Boot mode is activated, the firmware can be updated via SM Boot application (part of 3SModbus software suite) or Sensistant. Fig. 5 P1 header 1 2 3 4 5 1 2 3 4 5 Put a jumper onto pins 1 and 2 and wait for at least 5 seconds to reset the Modbus communication parameters Put a jumper onto pins 3 and 4 and restart the supply to enter bootloader mode MIW--EN-000-11 / 04 / 2018 www.sentera.eu 8-11

VERIFICATION OF INSTALLATION INSTRUCTIONS If your unit does not function as expected, please check the connections. MODBUS REGISTER MAPS INPUT REGISTERS Data type Description Data Values 1 Temperature signed int. Actual temperature level -300 700 50 50,0 C 2 Relative humidity Actual relative humidity level.000 1.00 100,0 % rh 3 Dew point signed int. Calculated dew point -700 700 20 20,0 C 4 CO 2 Actual CO 2 level 0 2.000 2.00 2.000 ppm 5 10 Reserved, return 0 11 Output value 1 Output value.000 12 13 Reserved, return 0 1.00 0 % 100 % 14 Temperature alert flag 15 Relative humidity alert flag 16 CO 2 alert flag 17 Temperature limit flag 18 Relative humidity limit flag 19 CO 2 limit flag 20 Humidity / temperature sensor fault Flag indicates that measured temperature is outside set alert values. Set to 1 when the measured value is outside the temperature alert values defined by holding registers 20 and 21. Flag indicates that measured relative humidity is outside set alert values. Set to 1 when the measured value is outside the relative humidity alert values defined by holding registers 22 and 23 Flag indicates that measured CO 2 level is outside set alert values. Set to 1 when the measured value is outside the CO 2 limit values defined by holding registers 24 and 25 Flag indicates that measured temperature is outside set limit values. Set to 1 when the measured value is outside the temperature limit values defined by holding registers 14 and 15 Flag indicates that measured relative humidity is outside set limit values. Set to 1 when the measured value is outside the relative humidity limit values defined by holding registers 16 and 17 Flag indicates that measured CO 2 level is outside set limit values. Set to 1 when the measured value is outside the CO 2 values defined by holding registers 18 and 19 Flag indicates if the communication with the temperature and humidity sensor is lost 21 CO 2 Sensor fault Flag that shows if the communication with the CO 2 sensor is lost. 22 Reserved, returns 0. Measured temperature is OK Measured temperature is too high/ low Measured rh is OK Measured rh is too high/ low Measured CO 2 is OK Measured CO 2 is too high/ low Temperature is OK Temperature is too high/ low rh is OK rh is too high/ low CO 2 is OK CO 2 is too high/ low No Yes No Yes MIW--EN-000-11 / 04 / 2018 www.sentera.eu 9-11

HOLDING REGISTERS Data type Description Data Default Values 1 Device slave address Modbus device address 1 247 1 2 Modbus baud rate Modbus communication baud rate 0 6 2 3 Modbus parity mode Parity check mode 0 2 1 4 Device type Device type (Read only) = 1100 5 HW version Hardware version of the device (Read only) XXXX 0x010 HW version 1.00 6 FW version Firmware version of the device (Read only) XXXX 0x010 FW version 1.00 7 13 Reserved, return 0 14 15 16 17 Minimum temperature Maximum temperature Minimum relative humidity Maximum relative humidity 18 Minimum CO 2 19 Maximum CO 2 20 21 22 23 Minimum temperature alert Maximum temperature alert Minimum relative humidity alert Maximum relative humidity alert Minimum value of the temperature ; cannot be set higher than max. temperature minus 5ºC Maximum value of temperature ; cannot be set lower than min. temperature rang e plus 5ºC Minimum value of the rh ; cannot be set higher than max. rh minus 5 % Maximum value of rh ; cannot be set lower than min. rh plus 5% Minimum value of the CO 2 ; cannot be set higher than max. CO 2 minus 100 ppm Maximum value of CO 2 ; cannot be set lower than min. CO 2 plus 100 ppm Minimum temperature alarm value Maximum temperature alarm value Minimum relative humidity alarm value Maximum relative humidity alarm value 2 = 3 = 4 = 5 = 6 = 2 = 4.800 9.600 19.200 38.400 57.600 115.200 230.400 8N1 8E1 8O1 0 (Max. - 50) 0 10 10,0 C (Min. + 50) 500 500 50 50,0 C 50 (Max. 50) 50 20 20,0 % rh (Min. + 50) 850 850 850= 85,0 % rh 0 (Max. 100) 400 1.00 1.000 ppm (Min. + 100) 2.000 2.000 2.00 2.000 ppm Min. temperature Max. temperature alarm Min. temperature alarm Max. temperature Min. relative humidity Max. relative humidity alarm Min. relative humidity alarm Max. relative humidity 0 10 10,0 ºC 500 50 50,0 ºC 50 20 20,0 % rh 850 85 85,0 % rh 24 Minimum CO 2 alert Minimum CO 2 alarm value Min. CO 2 Max. CO 2 alarm 400 40 400 ppm 25 Maximum CO 2 alert Maximum CO 2 alarm value Min. CO 2 alarm Max. CO 2 2.000 2.00 2.000 ppm 26 29 Reserved, return 0. 30 Modbus network resistor termination (NBT) Set device as ending the line or not by connecting NBT 31 35 Reserved, returns 0. 36 Modbus registers reset 37 CO 2 module self calibration (ABC logic) algorithm 38 Minimum output value 39 Maximum output value Resets Modbus Holding registers to default values. When finished this register is automatically reset to 0 Enables or disables the CO 2 module selfcalibration algorithm. If enabled, the sensor will typically reach its operational accuracy after 24 hours of continuous operation. The sensor will maintain its accuracy given that it is exposed to a reference level of 400 ppm CO 2 at least once in a 7 day period Sets minimum value of output signal in percentage Sets maximum value of output signal in percentage 40 Reserved, returns 0. 0 0 1 If you want to find out more about Modbus over serial line, please visit: http://www.modbus.org/docs/modbus_over_serial_line_v1_02.pdf NBT disconnected NBT connected Idle Reset Modbus registers Disabled Enabled 0 40 0 2 20 % 600 100 6 60 % MIW--EN-000-11 / 04 / 2018 www.sentera.eu 10-11

TRANSPORT AND STORAGE Avoid shocks and extreme conditions; stock in original packing. WARRANTY AND RESTRICTIONS Two years from the delivery date against defects in manufacturing. Any modifications or alterations to the product after the date of publication relieve the manufacturer of any responsibilities. The manufacturer bears no responsibility for any misprints or mistakes in this data. MAINTENANCE In normal conditions this product is maintenance-free. If soiled, clean with a dry or damp cloth. In case of heavy pollution, clean with a non aggressive product. In these circumstances the unit should be disconnected from the supply. Pay attention that no fluids enter the unit. Only reconnect it to the supply when it is completely dry. MIW--EN-000-11 / 04 / 2018 www.sentera.eu 11-11