TENDER NO. PGVCL/PROC/SMC BOX FOR CT OPERATED METER & Junction Box/867

Similar documents
TECHNICAL SPECIFICATION FOR SMC AMR METER BOXES MADE FROM THERMOSETTING PLASTIC

DC POWER DISTRIBUTION BOARD

Eligibility Criteria for Participation [Qualification Requirement (QR)]

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

Tender document for Supply/ Installation of New Fire extinguishers & Refilling TENDER NOTICE

KAIGA GENERATING STATION

Annexure - 1. Detectors: Fire Alarm Control Panel :

Table-1: Clarifications and modification in tender specifications based on Pre-bid meeting discussion

TENDER DOCUMENT FOR SUPPLY OF EPOXY MIXING & POURING PLANT

LINEAR HEAT DETECTION SENSOR CABLE ACCESSORIES

Indian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi , Ph. No.

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

NOTICE INVITING TENDER

Energy Saving Band Heaters

TECHNICAL SPECIFICATION AUTOMATIC SINGLE POLE AND THREE POLE CIRCUIT BREAKERS FOR LV SUPPLIES

Transportation. Distribution

TENDER CRFQ NO (E-TENDER REF NO.13020)

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

Survey of electrical equipment installed in hazardous areas on tankers

w w w. w a s h e r h u b. c o m

Supply & Installation of Fire Protection System at STPI- Nashik. Tender No. STPI/P/PUR/07/14-15 Date Signature of Bidder

TENDER NOTICE FOR RATE CONTRACT FOR SUPPLY, INSTALLATION AND REFILLING OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS

STANDARD TECHNICAL SPECIFICATION FOR PRESSURE SWITCH, DIFFERENTIAL PRESSURE SWITCH VOLUME - IIB. SPECIFICATION No: PES

Department of Biochemistry University of Lucknow Lucknow

BANK OF BARODA, ZONAL OFFICE, EASTERN U.P ZONE, BARODA HOUSE, V-23, VIBHITI KHAND, GOMTI NAGAR, LUCKNOW, TEL: , TENDER NOTICE FOR

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

Material Description Quantity UOM

TECHNICAL SPECIFICATION FOR. 11 kv 25 KA INDOOR SWITCHGEAR INTEGRATED WITH ASSOCIATED CONTROL AND RELAY PANELS AND CONTROL DESK FOR REMOTE OPERATION

SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD.

Independent, accredited testing station Member laboratory of STL and LOVAG

TENDER DOCUMENT FOR CHECKING, TESTING AND REPAIRING OF FIRE HYDRANT AND SPRINKLER SYSTEM AT Bank Of India, STC Building, B-32, Sector-62 Noida

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

DEVIL CERAMIC SPACE HEATERS

PURCHASE ENQUIRY. Enquiry No : AFD/PUR/PKS/ENQ/High Speed/1, April 08, 2017

BANK OF BARODA BIHAR REGIONAL OFFICE, 4 TH FLOOR, ANAND VIHAR, West Boring Canal Road, Patna TENDER NOTICE

Part: I TECHNICAL SPECIFICATION

BANK OF BARODA ZONAL OFFICE, MP & CG ZONE BHOPAL TENDER NOTICE

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF PORTABLE FIRE EXTINGUISHER- PERFORMANCE AND CONSTRUCTION AS PER IS 15683: 2006

BANK OF BARODA, ZONAL OFFICE, EASTERN U.P ZONE, BARODA HOUSE, V-23, VIBHITI KHAND, GOMTI NAGAR, LUCKNOW, TEL: , TENDER NOTICE FOR

TENDER NOTICE FOR SUPPLY, INSTALLATION AND MAINTENANCE OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS

Time Extension: Tender submission deadline is extended up to 12:00 Hrs. of

* To be remitted only through DD/Banker Cheque, in favour of Bank of Baroda, payable at Bhopal.

Technical Specification For Design and supply of Water Mist cum CAFS (Compressed Air Foam System) Backpack Fire Fighting System

TENDER NOTICE FOR SUPPLY, INSTALLATION AND MAINTENANCE OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN KARNATAKA & ANDHRA PRADESH ZONE

INVITATION FOR QUOTATION. TEQIP-II/2015/RJ1G08/Shopping/25

ELSTA MOSDORFER- Energy Distribution with Competence

Bank of Baroda Zonal Office, Tamil Nadu and Kerala Zone, Baroda Pride, New No.-41, Luz Church Road, Mylapore, Chennai

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Section 8: Switchgear Connections (Straight & Elbows)


MANUFACTURER OF LT PANELS

ENGINEERING PROJECTS (INDIA) LTD. (A Govt. of India Enterprise) Signature of Bidder 1 of 11 EPI

TENDER NOTICE FOR DESIGNING, SUPPLY, INSTALLATION, TESTING, COMISSIONING AND MAINTENANCE OF FIRE ALARM SYSTEM AT APROX.

TIME KNITWEAR (PVT) LTD.

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

BUREAU OF INDIAN STANDARDS CENTRAL MARKS DEPARTMENT-III

Ravi Malik General Manager

Due to large sum and BG processing time it is requested to offer 15 Working days instead of 7 working days.

Tempest TP420/180 Electric Pressure Washer

PANTHER. Condensate removal pump Installation and operating guide

OPERATING & MAINTENANCE INSTRUCTIONS

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

SolderSleeve Insulated Electrical Termination Devices

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA TECHNICAL SPECIFICATION FOR

Relationship beyond banking

Notice inviting Tender for Development of Signature Stall

CORRIGENDUM NO: 2 TO REQUEST FOR QUOTATION CRFQ NO E-Tender Ref. No: 9093

COMPONENT SOLUTIONS for the lighting industry

Lloyd s Register Type Approval System Test Specification Number 3

WESTERN ZONAL OFFICE ENGINEERING DEPTT. WEST WING, FIRST FLOOR, "YOGEKSHEMA, NARIMAN POINT MUMBAI

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

38-SDMS-01 SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS

OFFICE OF THE PRINCIPAL GOVERNMENT ENGINEERING COLLEGE JAGDALPUR (C.G.)494005

Heated Display. Instruction manual. Model: CW147 / CW148

new new Industrial plugs and sockets

BANK OF BARODA BARODA CORPORATE CENTRE MUMBAI

IECEx Certificate of Conformity

DUST EXTRACTOR MODEL No: CDE1000

इ ड यन ओव रस ज ब क Indian Overseas Bank. क ष त र य क य ऱय, Regional Office, Chandigarh

Product Information Motor and machine protection

TECHNICAL SPECIFICATIONS SWIVEL ARM GRINDING MACHINE

TITANIA F4 PYTHON EXPLODED VIEW

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

NATIONAL BANKING GROUP WEST-1

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

ELECTRICAL SAFETY INSPECTION REPORT

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

CK C O M P R E S S O R

MODEL NO: CW2D PART NO: OPERATING & MAINTENANCE INSTRUCTIONS

1 NOS. 25mm x 4 mm thick with PVC sleeving e) 1Set, RYB, indicating lamps & CT

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

CAN/ULC-S109 Flame Resistance of "Argo" Fabric

Standard Specification for Hardened Steel Washers [Metric] 1

Heating Element. Building Technologies HVAC Products

Calling for Quotations

Transcription:

1.0 SCOPE: SCHEDULE - X TECHNICAL SPECIFICATION FOR SERVICE CONNECTION BOX MADE FROM THERMOSETTING PLASTIC FOR SERVICE CONNECTIONS. 1.1 This specification covers the design, manufacturing and testing of anticorrosive, dust proof, rust proof, shock proof, self extinguishing property, resistant to heat, vermin & water proof, Ultra Violet Stabilized and pilfer resistant Service Connection Dist. Box made from Thermosetting Plastic i.e. Glass Reinforced Polyester Sheet Moulding Compound (SMC) Confirming to IS:13410 (1992) and attached technical specification, drawing and IS 14772:2000. 2.0 CONSTRUCTION: 2.1 Service Connection Box shall be moulded in a single piece forming the body of the Service Connection Box with a cover fitted with base by minimum two nos. concealed Anticorrosive hinges. The lid/cover shall rest on the collar of the Service Connection Box base in such a way that any access from outside of the box is not possible. The hinges shall be fitted with the Service Connection Box body base and cover rigidly, thereby making the Service Connection Box pilfer resistant. All corners of the Service Connection box should be round & not pointed ones. 2.2 The door in closed position should be overlapped in such a manner that no direct entry or access is possible. The Service Connection Box shall be closed by MS U Clamp of minimum 1.2 mm. thickness for holding and locking of the door with body base. The U Clamp shall sealing arrangement for sealing purpose. 2.3 The top surface of box shall have little tapering shape towards both sides of the Service Connection Box for easy flow of rainwater. Page 1 of 9

Required arrangements per box should be as follows: Sr. No Details Box for 4 nos. of 3 ph. connection 01 Size of the box 250 x 250 x 160 mm Box for 8 nos. of 1 ph. connection 250 x 250 x 160 mm 02 Thickness 1.5mm 1.5 mm 03 Opening of the box 90 90 04 No of holes on backside box wall having 6 mm 04 No 04 No dia for fixing of box. 05 Earth bolt of 6 mm dia x 20 mm length with 2 01 No 01 No nuts and 2 washers 06 Cable Entry Hole with good quality rubber grommets as shown in drawing. 35 mm 01 No 25 mm 01 No 07 Cable Exit Holes with good quality rubber grommets as shown in drawing. 25 mm 04 No 14 mm 08 No 08 Required no of Distribution Blocks (Phase) 03 No 01 No 09 Required no of connection per Distribution Blocks (per Phase) 04 No 08 No 10 Distribution Blocks (Phase) should have I/C 35 sq mm I/C 35 sq mm arrangement for cable connection purpose O/G 10 sq mm O/G 10 sq mm 11 Current Carrying capacity of each Distribution Blocks (Phase) I/C 114 AMP O/G 57 AMP I/C 114 AMP O/G 57 AMP 12 Required no of Distribution Blocks (Neutral) 01 No 01 No 13 Required no of connection per Distribution Blocks (Neutral) 12 No 08 No 14 Distribution Blocks (Neutral) should have I/C 04 sq mm I/C 35 sq mm arrangement for cable connection purpose O/G 04 sq mm O/G 10 sq mm 15 Current Carrying capacity of each Distribution I/C 32 AMP I/C 114 AMP Blocks (Neutral) 16 Fixing arrangement of each Distribution Blocks (Phase & Neutral) O/G 32 AMP A fixed Alkaline Zinc Plated with Yellow Passivation DIN Channel O/G 57 AMP A fixed Alkaline Zinc Plated with Yellow Passivation DIN Channel Page 2 of 9

3 GUARANTEED TECHNICAL PARTICULARS: 3.1 Guaranteed Technical particulars are given in enclosed Annexure A and B. Bidder shall submit the data in given Performa. 4 TYPE TEST CERTIFICATE: 4.1 The bidder shall submit type test report as per IS-14772-2000 & IS 13410 : 1992 from CIPET, Ahmedabad / ERDA, Baroda along with the offer. Type Test Certificate should not be older than 5 years as on the date of tender opening. 5 ROUTINE TEST : 5.1 Manufacturer has to carryout routine test during production to check the essential requirements that are likely to vary during production. Manufacturer has to keep records of the same and to be produced for verification of inspector when asked at the time of inspection of lot. 6 ACCEPTANCE TEST 6.1 The acceptance tests shall be carried out on randomly selected samples as per Annexure-B 7 TYPE TEST From the offered lot, Sample shall be picked up at discretion of Company for type test at CIPET, Ahmedabad / ERDA, Vadodara pr any NABL accredited laboratory for every 10,000 nos. supply. The charges for the Type Test shall be borne by bidder. On passing the type test successfully, the lot shall be accepted. In case, the boxes are not confirmed to type test, another sample from the lot shall be selected and tested again. On receipt of unsatisfactory results, the lot shall be rejected and new lot shall be offered for inspection keeping aside old lot offered and rejected earlier by the Company. However Company reserves the right to accept the boxes by levying penalty at the discretion of the Company. 8 RAW MATERIALS 8.1 The manufacturer has to submit the test certificate for the material used in the lot offered and document for purchase of raw material. 9.0 FACILITY 9.1 The bidder shall have facility to test the box for routine tests and acceptance as per IS 14772: 2000 and IS - 13410 at their works. The bidder has to submit list of Machinery & Equipment / Testing instruments etc. Page 3 of 9

10.0 INSPECTION AND TESTING 10.1 The bidder has to offer the boxes for inspection at his works before dispatch. The manufacturer will offer all facilities to inspector without any charge. 11 DESPATCH 11.1 The Service Connection Boxes shall be so dispatched as to ensure that no damage occurs during transport where they may be subject to rough handling. 12 TENDER SAMPLE 12.1 One tender sample as per specifications will have to be submitted before last date of submission of Tender to The Deputy Engineer (Regional store Office) PGVCL,Dudhsagar Road,Rajkot Page 4 of 9

SR. NO. ANNEXURE A GUARANTEED TECHNICAL PARTICULARS PARTICULARS DETAILED PARTICULARS 1 Maker's name To be intimated by the supplier 2 Material Glass reinforced polyester sheet moulding compound 3 Grade of Material SMC confirming to IS: 13410:1992 Grade S 1 4 Properties of Material of Construction of Service Connection Box Heat Deflection Temperature 150 C (Minimum) (Ref. Std. IS:13411) Exposure to flame (Ref. Std. IS:4249) Self-extinguishing Melting Point (Ref. Std. IS:13360) Does not melt Glow wire test at 650 C As per IS 11000 Part- 2/sec-1 Degree of protection IP-42 as per IS-12063 / 87 Heat distortion temp. 125 C (Min) as per IS:13411 9 KV/mm (Min) as per IS : 6262-1971 To be mentioned by the supplier Dielectric Strength at 90 C in oil 5 Inside dimension of Service Connection Box a. Height 250 mm (min) b. Width 250 mm (min) c. Depth 160 mm (min) d. Thickness of SMC sheet 6 Earthing Arrangement Earthing bolt 01.50mm (min) One no. of Earthing bolt of MS with 2 nuts and 2 washers shall be provided on RH side of box. Earthing sign has to be provided near to earthing bolt. TO BE OFFERED BY BIDDER Page 5 of 9

Dia. & Length of earthing bolts 7 Locking arrangement 8 Manufacturer short name & Company logo shall be Printed on the front side of the box Dia. 6 mm Length 20 mm For Holding & Locking of door with base one no. of "U" shaped clamps to be provided To be provided on the front side of the box 9 Sealing arrangement Holes for wire seal. 10 Wire entry plugged holes 11 Colour of Service Off White Connection Box 13 Distribution Blocks Mounting Arrangement 14 Distribution Blocks (Phase) Current Carrying Capacity (Phase) Fixed Alkaline Zinc Plated with Yellow Passivation DIN Channel Three Phase 04 each Single Phase 08 each Single Phase 04 each Page 6 of 9

Cable Size (Phase) Three Phase 04 Single Phase 08 Single Phase 04 15 Distribution Blocks (Neutral) Current Carrying Capacity (Neutral) Three Phase 04 Rating Incoming = 32 Rating Outgoing = 32 each Single Phase 08 each Single Phase 04 each Cable Size (Phase) Three Phase 04 Incoming = Upto 04 sq.mm Outgoing = Upto 04 sq.mm Single Phase 08 Page 7 of 9

Single Phase 04 Page 8 of 9

ANNEXURE B TEST REQUIREMENT FOR SERVICE CONNECTION BOX Reference Standards ROUTINE TEST Protection against electric shock IS 14772 Provision for earthing - Do - ACCEPTANCE TESTS (Random samples 10 nos. to be selected) Marking ( Name, Trade mark) - Do - Protection against electric shock - Do - Provision for earthing - Do - Construction and Dimension verification - Do - Heat distortion temperature (min.150 0 C) (On any one IS 13411 sample) Self Extinguishing (On any one sample) IS: 4249 TYPE TEST Marking IS: 14772 Dimensions - Do - Protection against electric shock - Do - Provision for earthing - Do - Construction - Do - Resistance to ageing, to humid conditions, ingress of - Do - Solid objects and to harmful ingress of water Mechanical strength - Do - Resistance to heat - Do - Resistance of insulating material to abnormal heat and - Do - fire Resistance to rusting - Do - Resistance of tracking - Do - Heat distortion temperature (min.150 0 C) IS 13360 (Part VI Sec III) Self Extinguishing IS: 4249 Material Identification CIPET Page 9 of 9