Starting current with soft starter Fuse protection

Similar documents
Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

Starting current with soft starter Fuse protection. Heat source connection

Starting current with soft starter Fuse protection

Dimplex High efficiency air-to-water heat pump for indoor installation. (Low temperature) Order reference

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels

Product Range Overview 2010

PRODUCT DATA SHEETS HEAT PUMPS

WARMTEPOMPEN DIMPLEX. POMPES À CHALEUR DIMPLEX.

Technical data LA 60TUR+

Product Range. Overview 2015.

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

Technical data LA 60TU

Technical data LA 28TBS

Technical data LA 9S-TU

Advance Split

BWL air heat pumps BWS brine heat pumps

For a future without oil and gas.

VIESMANN. VITOCAL Air/water heat pumps. Technical guide. VITOCAL 300-A Type AWC-I and AW-O. VITOCAL 350-A Type AWH-I and AWH-O

WZS 82(H)(K)3M 20 I B0W I I I (263) (288) 7.0

Air / Water Heat Pump - Compact Design Modulating 8 18 kw

LZT High efficiency air to water heat pumps with E.V.I. compressors

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

A w rld of new product innovation new product launches

LZA High efficiency air to water heat pumps with HP compressor

your tree NEW TREE for you Several facts on trees: Follow our Green Tree heat pumps

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

Product Line Introduction. Karl Zhang Technical support engineer

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

Planning guide. (2010/09) en

MODEL LA 6 MI LA 9 MI LA 12 MI LA 16 MI. Heat output (kw)/cop at A-15/W35 5.9/ / / /2.33

HIGH-POWER HEAT PUMPS. Up to 300 kw

HT V2 HT Split

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Efficient heating that won t cost the earth

LZT High efficiency air to water heat pumps with E.V.I. compressors

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Do you want a versatile solution

VIESMANN VITOCAL 300-G Brine/water and water/water heat pump Single and two-stage, from 21 kw

NABILATON PRO. The Nabilaton Pro heat pumps consist of MDV brand outdoor units and suitable hydraulic modules from Nabilaton.

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Oilon Ground Source Heat Pumps

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Saving energy comes naturally to us.

High temperature air-to-water heat pumps

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Technical description. Atec.

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

TOSHIBA AIR CONDITIONING

HPWH 300 HPWH 300HE. Installation and Operating Instructions. Hot Water Heat Pump for Outdoor Installation. English FD 9501

ECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps.

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Heat pump systems and Chillers

PRODUCT RANGE HEAT PUMPS 2012

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

Planning guide. Atec.

Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss

WZH Ground source heat pumps

CRIMSON & CRIMSON MAX

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

Air to water Heat Pump System

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

50A KP 70A KP 90A KP 120A KP 150A KP 210A

PROJECT PLANNING AND INSTALLATION MANUAL

HEAT PUMPS EN - flyer 10/p/2017 Made in Poland

NIBE SPLIT ACVM 270 Air/water heat pump

REMKO HYBRID HEAT PUMPS

WPM 2006 plus WPM 2006 R WPM 2007 plus WPM 2007 R

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

SmartRad Planning Manual

Galletti Water chillers and heat pumps catalogue

Technical specifications

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Installation and operating instructions. DK energy storage and DK energy buffer

WHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

UK arotherm Schematics and installation guide

Transcription:

Data sheet LIH 26TE High temperature air-to-water heat pump Max. flow temperature: 75 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for heating purposes for indoor installation with integrated WPM 2007 plus controller. The control panel is integrated into a brown-red design screen and can also be used as wired remote control using the wall mounting set (special accessories MS PGD). The integrated air circuit enables corner or wall installation with air ducts at the air intake and the air outlet side. Sound-optimised through low-noise axial fan and vibration-isolated compressor. High coefficients of performance (COP) using an evaporator optimised for heating operation and energy-efficient defrosting by reverse circulation. Universal design with low temperature and high temperature levels, optional domestic hot water preparation and the possibility of flexible expansion for: - Bivalent or bivalent-renewable operating mode - Distribution systems with unmixed and mixed heating circuits In the summer a maximum flow temperature of 58 C is available for domestic hot water preparation. Integrated flow and return sensors; external sensor (standard NTC-2) included in the scope of supply. Technical data Dimplex High temperature air-to-water heat pump (High temperature) Order reference LIH 26TE Heat pump code 1001 Casing colour White (similar to RAL 9003) Max. flow temperature 75 C Lower operating limit heat source (heating operation) / Upper operating limit heat source (heating operation) -25 to 35 C / COP A-7/W35* 12,9 kw / 2,6 Heat output A2/W35 / COP A2/W35* 15,7 kw / 3 / COP A7/W35* 19,5 kw / 3,6 / COP A10/W35* 20,2 kw / 3,7 Nominal power consumption according to EN 14511 at A2/W35 5,16 kw Nominal power consumption according to EN 14511 at A7/W35 5,25 kw Sound power level device 62 db (A) Sound pressure level in 1 m (indoors) 58 db (A) Refrigerant / Amount of refrigerant R404A / 3,7 kg Max. heating water flow rate / Pressure drop 2,7 m³/h / 8200 Pa Heat source flow (min.) 8000 m³/h Dimensions (W x H x D)** 750 x 1710 x 1030 mm Weight 389 kg Rated voltage 3/N/PE ~400 V, 50 Hz Starting current with soft starter 30 A Fuse protection C 25 A Type of defrosting Reverse circulation Connection heating 1 ¼ inch *Heat output and COP according to EN 14511 at A2/W35 (A2 = air intake temp. +2 C, W35 = heating water outlet temp. +35 C) **Please note that additional space is required for pipe connections, operation and maintenance. Page 1/6

System accessories LIH 26TE Description Heat pumps Order ref. Article number Sample High temperature air-to-water heat pump LIH 26TE 352740 1 Elasticated sound insulation underlay strips SYL 250 352260 2 DN 32 double-sphere rubber expansion joint KOMP 32 362060 DN 32 dirt trap SMF 32 362140 Heat source accessories 90 air duct bend LKB 800A 366170 1 90 air duct bend LKB 800 339820 Sealing collar 800 DMK 800 340290 1 Deflector hood LUH 800 358640 Rain guard for LI(H) RSG 800 340250 2 Hydraulic accessories Heating water hose connection set SAS 110 340330 1 Free-standing buffer tank 200 l PSW 200 339830 1 Immersion heater 4.5 kw; ~230 V CTHK 630 363610 Immersion heater 2.0 kw; ~230 V CTHK 631 336180 Immersion heater 2.9 kw; ~400 V CTHK 632 335910 Immersion heater 4.5 kw; ~400 V CTHK 633 322140 1 Immersion heater 6.0 kw; ~400 V CTHK 634 322150 1 Universal buffer tank (500 l)* PSW 500 339210 Dual differential pressureless manifold DDV 32 348450 1 Circulating pump for heating water UP 70-32 354020 1 Manifold bar VTB 25 339870 Manifold bar (3-fold) for modules DN 25 and DN 32 VTB 32 367770 Domestic hot water module/unmixed heating circuit module WWM 32 367800 1 Mixed heating circuit module MMH 32 367790 Mixer module for bivalent systems MMB 32 367780 Electronically regulated wet running pump (0-10 V) with coupling relay UPE 70-32 362800 1 Electronically regulated wet running pump (0-10 V) with coupling relay UPE 80-32 362820 Electronically regulated wet running pump (0-10 V) with coupling relay UPE 120-32 362830 Ready-for-use DN 32 stainless steel Wellflex pipe VSE 32-50 362520 Ready-for-use DN 32 stainless steel Wellflex pipe VSE 32-100 362530 Ready-for-use DN 32 stainless steel Wellflex pipe VSE 32-150 362540 Ready-for-use DN 32 stainless steel Wellflex pipe VSE 32-200 362550 Ready-for-use DN 32 stainless steel Wellflex pipe VSE 32-300 362560 Immersion heater pipe assembly* HDLR 450 337450 Heating accessories Fan convectors heating 800 W SRX 080M 359080 Fan convectors heating 1200 W SRX 120M 359090 Fan convectors heating 1400 W SRX 140M 359100 Fan convectors heating 1800 W SRX 180M 359110 DHW preparation accessories Domestic hot water cylinder (500l) with temperature sensor WWSP 900 339220 1 Flange heater for domestic hot water FLH 60 338060 Flange heater for domestic hot water FLHU 70 338070 1 Flange heater for domestic hot water FLH 90 366130 FLH 25M flange heater FLH 25M 349430 Safety valve combination SVK 852 326660 PWS 650 combination tank* PWS 650 367660 Combo tank for heating and domestic hot water preparation with central flow* PWD 750 349100 Combo tank for heating and domestic hot water preparation with central flow* PWD 900 362860 Combo tank for heating and domestic hot water preparation with central flow* PWD 1250 362890 Pump unit DN 32 for direct connection of the domestic hot water cylinder WPG 32 356040 1 Electronically controlled circulating pump with coupling relay UPH 60-32 366920 1 Circulating pump for heating water UP 70-32 354020 item Item Price Page 2/6

System accessories LIH 26TE Description Order ref. Article number Fresh water station FWS 27 FWS 27 367310 FWS WT fresh water station FWS WT 368100 Control accessories Flow rate switch DFS 32-13 368220 Extension for an Ethernet network connection NWPM 356960 Extension for a KNX/EIB bus connection EWPM 356970 Extension for a Modbus connection LWPM 410 339410 Swimming pool/remote fault indicator relay module RBG WPM 339700 MS PGD wall mounting kit MS PGD 353810 Outside temperature sensor with casing FG 3115 336620 Temperature sensor NTC-10 with metal sleeve NTC-10M 363600 Thermostat for heating and domestic hot water KRRV 003 322070 * Other specific accessories available / required Sample Important information: The combination of the components and the quantities indicated represent a non-binding sample system, which needs to be tested and individually adapted as required. Pump dimensioning must be reviewed according to the pressure loss of the system and the minimum heating water flow rate of the heat pump. item Item Price Page 3/6

Air-to-water heat pump, Integration Diagram, Heat pump and immersion heater Note: The given hydraulic integration schematic is a schematic representation of the key components and serves as an aid for planning your customized system. The current status is available at all times under www.dimplex.de/nc/en/professional/onli ne-planner/hydraulic-integrations.html. It does not contain all the required safety devices, the components needed to maintain constant pressure, or any other additional valves which may be required for maintenance and service work as stipulated by EN 12828. The heat pump manager settings and any external regulation system which may be connected must be adapted to the present integration diagram. Software updates may be required! Page 4/6 Integration Diagram: 10231020

Air-to-water heat pump, Integration Diagram, Heat pump and immersion heater System description: Air-to-water heat pumps with defrosting by reverse circulation extract the energy required for defrosting from the heating system. In the case of air-to-water heat pumps, a buffer tank connected in series, into which the immersion heater is screwed, must be installed in the flow in mono energy systems to ensure defrosting. A dirt trap with a mesh size of between 0.6mm and 0.8mm is to be installed in order to protect the plate heat exchanger from larger dirt deposits. Clean the filter sieve of the dirt trap one day after start-up. These intervals can be extended as soon as no more impurities are detected. When the level of impurities is significantly high (e.g. due to corrosion found in the building), it is recommended that a sludge trap be installed in order to minimise the need for regular cleaning. A permanent corrosion process, caused by the entry of oxygen into the system, is characteristic of heating systems featuring open diffusion. This is best alleviated using an electrophysical anti-corrosion system. Condensate which forms during defrosting must be drained off without risk of frost. Acoustic emissions must be taken into account, and a free air circuit provided for, when the installation location is being selected. Heat pumps without weather-proof protective covers in particular need to be installed outdoors in such a manner that the air outlet is not positioned against the main wind direction. A buffer tank connected in series is recommended for heat pump heating systems, to ensure the minimum heat pump runtime of 6 minutes for all operating statuses. Presettings: Pre-configuration Operating mode Heating circuit 1 Heating circuit 2 DHW preparation DHW preparation request by Domestic hot water preparation flange heater Swimming pool water preparation Setting Mono energy Yes No Yes Sensor Yes No The heat pump supplies a large part of the required heat output. An electric heating element (immersion heater) supplements the heat pump on days when the external temperature lies below the bivalence point. In mono energy systems, the contactor for the immersion heater (E10.1) must be set according to the output. It is controlled (230 V AC) by the heat pump manager via terminals X1/N and J13/NO4. The heat exchanger in the hot water cylinder must transfer the maximum heat output at the maximum heat source temperature. In systems with high hot water consumption (multiple dwellings, industrial applications) the cylinder must be set to the maximum peak demand while taking the shut-off times into account. The maximum heat output and the maximum heating water flow must be adhered to! The contactor for the flange heater (E9) in the hot water cylinder should be dimensioned according to the output and must be supplied by the customer. It is controlled (230 V AC) by the heat pump manager via terminals X1/N and J16/NO10. The maximum heat output of the heat pump and the water flow are to be observed. The dual differential pressureless manifold ensures that the required minimum water flow rate is maintained, independent of both the number of open heating circuits and of how the system is used. Hydraulic isolation is carried out using two connections between flow and return; each connection is fitted with a check valve. The characteristic curve of the pump in the consumer circuit must be set in such a way that a maximum spread of 10 Kelvin is not exceeded, in order to prevent unnecessary surging of the heat pump. Electronically regulated pumps must be operated at a constant pressure. Page 5/6 Integration Diagram: 10231020

Air-to-water heat pump, Integration Diagram, Heat pump and immersion heater Legend: 1. Heat Pump 1.1 Air-to-water heat pump 1.2 Brine-to-water heat pump 1.3 Water-to-water heat pump 1.4 Reversible air-to-water heat pump 1.5 Reversible brine-to-water heat pump 1.6 Reversible water-to-water heat pump 1.7 Air-to-water heat pump split design 2. Heat pump manager 3. Parallel buffer tank 3.1 Buffer tank 4. Hot water cylinder 5. Swimming pool heat exchanger 6. Passive cooling station with cooling controller N6 7. Heating and silent or dynamic cooling 8. Fan convector with 4-wire connection 9. Cooling circuit only 10. Heating circuit only 13. Heat source 15. Hydraulic tower 16. Scalding protection 17. Hydro tower HWK 332 Domestic hot water distribution system: DDV 25 DDV 32 EB KPV KPV 25 MMB 25 MMH 25 VTB 25 WWM 25 Dual differential pressureless manifold (up to 2.0 m³/h)* Dual differential pressureless manifold (up to 2.5 m³/h)* Extension module for compact manifold (up to 2.0 m³/h)* Compact manifold with overflow valve (up to 1.3 m³/h)* In combination with EB KPV (up to 2.0 m³/h)* Mixer module, bivalent (up to 2.0 m³/h)* Mixer module for heating circuit Manifold bar (up to 2.5 m³/h)* Hot water module / unmixed heating circuit (up to 2.5 m³/h)* * Recommended max. heating waterflow Solarthermics: SST 25 Solar station for hot water SOLK 1204 Collector field SOLPU 1 Solar station SOLCU 1 Solar controller SOLCU 2 Solar controller T1 Temperature sensor (collector sensor) T2 Temperature sensor (cylinder 1) T3 Temperature sensor (cylinder 2 /optional display function) B3 Hot water thermostat B4 Swimming pool thermostat B7 Thermostat primary circuit E9 Flange heater, hot water E10 2nd heat generator (HG2) E10.1 Immersion heater E10.2 Oil/gas boiler E10.3 Solid fuel boiler E10.5 Solar energy system F7 Safety temperature monitor F10 Flow rate switch K20 Contactor for 2nd heat generator K21 Contactor for immersion heater hot water M11 Primary pump for heating operation M12 Primary pump for cooling operation M13 Heat circulating pump for main circuit M14 Heat circulating pump for heating circuit 1 M15 Heat circulating pump for heating circuit 2 M16 Auxiliary circulating pump M17 Cooling circulating pump M18 Hot water circulating pump M19 Swimming pool water circulating pump M20 Heat circulating pump heating /cooling circuit 3 still M21 Mixer M22 Mixer heating/cooling circuit 2 M25 Circulating pump for heating and domestic hot water preparation N1 Heating controller N2 Cooling controller for reversible heat pumps N3/N4 Room climate control stations N6 Cooling controller for passive cooling N12 Solar controller N17.1 Cooling module general N17.2 Cooling module active N17.3 Cooling module passive N17.4 Solar module WPM Econ SOL R1 External wall sensor R2/2.1 Return flow sensor R3 Hot water sensor R4 Return flow sensor for cooling water R5 Temperature sensor for heating circuit 2 R9 Flow sensor (antifreeze) R11 Flow sensor for cooling water R13 Sensor for heating circuit 3 / bivalent-renewable SMF Dirt trap TC Room temperature controller Y5 Three-way distribution valve Y6 Two-way valve Y7 Three-way mixing valve Y8 Three-way valve (closing time max. 10 sec.) Y12 External 4-way reversing valve Y13 Three-way reversing valve Page 6/6 Integration Diagram: 10231020