AdvisorOne Quick Operation Guide

Similar documents
Simon XTi Quick Operation Guide

Simon XTi Quick Operation Guide

Simon XT User Manual R-11 and R-11-CN P/N REV B ISS 13JAN11

Simon XTi-5 User Manual

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

Reference information

RE6100 Series Helix Security and Automation Platform

Safewatch Pro 3000 System Manual

9000P Wireless Alarm Owner s Manual

Silencing an Alarm. When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display.

Destiny Destiny Owners Manual

Concord 4 User Manual

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

Rev C May GE Interlogix. Part No: R. CareGard. User Guide

Area Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.

D1265. User's Guide. Touchscreen Keypad

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

User s Manual. System Information... 3 Using the Touchpad Buttons... 3 General Operation... 4 Using Systems with Keyswitches... 4

Concord 5 TouchScreen Installation Sheet

XRSuper6. User s Guide

How to Use Your Sentrol Security System

Lyric Gateway. User Reference Guide. Ref: LCP300-L/LCP300-LC /16 Rev A

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Wireless Keypads LKP(E)S8M Series

XTL/XTLN/XTLN-WiFi USER GUIDE

Supervised Security System Owner's Guide

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Contents. Glossary

RF2352A, HC2351AC (Discontinued), HC2352AC

Wireless Security System

XTL Series USER GUIDE

abode Web app Functionality

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

Contact ID as of 2/2/2015

Silencing an Alarm. When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display.

1126 Series Ceiling Mount PIR Motion Detector

Simon XT User Manual P/N REV F OCT13

2GIG GC3 Security & Automation System. Fingertip Guide

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

AXI LED USER MANUAL (REV. 1.0)

PC4020 v3.2 Instruction Manual

FTP-1000 Touchpad/Display Installation Manual

Watchguard WGAP864 User Manual

Midco SmartHOME Quick Start Guide. Learn how to protect the things that matter most using this Midco SmartHOME instruction guide.

Wireless External Alarm

DESTINY OWNER S MANUAL

EVO192 v3.0 Fire and Burglary What s New

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

NetworX NX-8V2. LED Keypad User Manual

HILLS Series LED Code Pad User Manual

Total Connect Box. User manual

Security System. User s Guide for the Text Command Center

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01

NETWORX TM. User manual NX-4

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions

Silencing an Alarm Note: Area Systems What to do when a trouble tone is sounding

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

SECURITY SYSTEM NOTES

Security System. User Guide for the LED Command Center

XT30/XT50 U S E R G U I D E

Table of Contents. Appendix A Special Characters 31

Silencing an Alarm All/Perimeter or Home/Sleep/Away System What to do when a trouble tone is sounding

User's Manual VISTA-40 N7003V1 6/97

D3D Wi-Fi GSM Smart Alarm System -User Manual

icontrol OpenHome Converge Panel Interface Module Installation Guide Congratulations on purchasing your Panel Interface module.

Silencing an Alarm Note: Area Systems What to do when a trouble tone is sounding

IDS816 User Manual H Issued January 2009

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

User's Manual 5120XM N8031 6/96

Protect and connect. Home and away.

User s Information Guide R2A

Silencing an Alarm All/Perimeter or Home/Sleep/Away System What to do when a trouble tone is sounding

Silencing an Alarm All/Perimeter and Home/Away Systems. Area Systems. What to do when a trouble tone is sounding

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Installation Instructions

XRSuper6. User s Guide

XR500/XR100. User s Guide

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Pet Immune SAW PIR Motion Sensor

HS2016/HS2016-4/HS2032/HS2064/HS2064 E/HS2128/HS2128 E Alarm Panel. User Manual

WLS900 Wireless Security System. Table of Contents. Your installing company is, Name: Address: Phone: Your monitoring station is, Name: Phone:

NetworX NX-548E Receiver Installation Instructions

NX-148 LCD CODE PAD TABLE OF CONTENTS

VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

NetworX Series NX-1500E LED Keypad

XTLC PANEL INSTALLATION GUIDE

User Guide V3 4/13 Rev. C

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Panel XTO210/610/710 GPRS

INSTALLATION GUIDE XTLN-WIFI PANEL

Silencing an Alarm Note: Area Systems What to do when a trouble tone is sounding

Power864. User s Guide. Now classified in accordance with ANSI/SIA CP (SIA-FAR)

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

/10 Rev A

INSTRUCTION MANUAL PC255O

Transcription:

AdvisorOne Quick Operation Guide EN CNF ES PR English: Quick Operation Guide Introduction AdvisorOne (part # AVO-1037) is a wireless, self-contained system used to detect, control and inform of security and life safety conditions and threats. AdvisorOne uses a proprietary wireless technology to communicate with various types of sensors. The panel relays sensor status both visually using At-A-Glance icons on the touch screen display and audibly with beeps and verbal chimes. Can be connected to the internet via broadband through an Ethernet connection. Is controlled via the integrated touch screen. Using the AdvisorOne system Use this guide to quickly begin operating the AdvisorOne security system. An access code is needed to perform certain system functions. The default master code is 1-2-3-4 when AdvisorOne is shipped from the factory. The code should be changed after the system is installed (see User codes on page 4). Main screen The Main screen provides quick access to all system features that allows the user the ability to control the system. See Table 1 on page 2 for more information on these functions. P/N 466-4404-EE Rev H Dec 2014 1

Figure 1: AdvisorOne Main screen Note: The screen to the left is an example. Some systems are configured differently. Top Bar At a Glance area Bottom Bar Table 1: Main screen Icon Description Top bar Access the emergency screen to select the appropriate icon (Fire, Police, or Auxiliary). Time & Date The current system time and date. To change the time and date see To set the date and time: on page 4. An icon that provides quick access to system help, FAQ s, and dealer contact information. At-A-Glance area (If not programmed the At-A-Glance icons will be grayed out and N/A will appear) Door status - The icon depicted on the left indicates all monitored doors are closed. The icon depicted on the right indicates one or more monitored doors are open. Press the icon to obtain more information. Window status - The icon depicted on the left indicates all monitored windows are closed. The icon depicted on the right indicates one or more windows are open. Press the icon to obtain more information. Motions sensor status - The icon depicted on the left indicates no recent monitored motion is detected. The icon depicted on the right indicates monitored motion was detected in the last 10 minutes. Property status - Depicts status changes in monitored property protection in the building (i.e. water detection, glassbreak detection, smoke detection, CO detection, etc). The icon depicted on the left indicates all monitored sensors are closed and no activity has occurred since being checked. The icon depicted on the right indicates a monitored sensor is tripped or there is unacknowledged activity. Bottom bar Assets status - Depicts status changes in monitored assets in and around the building (i.e. movement of recreational vehicles, lawn care equipment, artwork, electronics, etc). The icon depicted on the left indicates all monitored sensors are closed and no activity. The icon depicted on the right indicates one or more monitored assets have unacknowledged activity. Press icon to obtain more information. Note: By obtaining more information this acknowledges the activity and resets the icon status to normal. Security Status - Press to access the System Status, Zone Status, and Events security status screens. Settings and Configuration - Press to access the General settings, Display, Sound, Date & Time, Applications, and Configuration screens. Applications - Press to gain quick access to the applications in the system. Press to access the active and inactive applications in the system. Contact the dealer for more information. Disarm - Pressing this icon will begin the sequence of disarming the system. Note: When disarmed, only 24-hour sensors (smoke, carbon monoxide detectors, etc) remain active. Arm Stay - Arms perimeter doors and windows only. Interior devices, such as motions remain off so you can stay inside the premises without setting off an alarm. Arm Night - Arms doors, windows, and interior motions, while leaving designated interior protection inactive. Contact the dealer for more information. Arm Away - Arms perimeter door/window sensors and interior motion sensors for maximum protection. 2 AdvisorOne Quick Operation Guide

Security Status screen To access the Security Status screen, press system. on the main screen. Use the Security Status screen to check the status of the Table 2: Security Status screen options Icon System Status Zone Status Events Description Displays event name and details of the event. Displays the status of the zones in your system. Displays a log of all system events (i.e. arming/disarming, alarms, connection issues, etc). The screen consists of Event Name, Occurred On, and Details. Settings Screen To access the Settings screen, press on the Main screen. Use the Settings screen to configure system options. Table 3: Settings screen options Icon General Display Sound Date & Time Applications Configuration Description Press General to access and/or configure the Chime, Apps Shown on Main Screen, Expertise, Help, and About options. Press Display to access and/or program the Brightness, Contrast, Background, Screen Saver, Screen Saver Time and Calibration. Displaying the Applications icon is enabled or disabled here. Press Sound to access and/or program the Application Volume, Security Volume, Keypress Volume, and Mic Gain Volume, Beep Volume and Voice Volume sound options ; adjustable from 1(low) to 10(high) bars.. Press Date & Time to access and/or program the Show Date, Time Format, and Date Format date and time options. Press Applications to make applications active or inactive in the system. Press Configuration to access and or program the Bypass Device, Users, Tests, Time Date, and Downloader options. Applications Note: Applications not evaluated by UL. To access applications on the AdvisorOne system from the Main screen: Swipe a finger on the middle part of the screen left or right to scroll through the options. OR Press and then press the desired application from the list on the Applications screen. Programming The AdvisorOne security system allows users to program certain options. To enter programming mode: 1. From the Settings screen, press CONFIGURATION. 2. Enter Master user code. Note: The Access Granted screen will appear. Press OK or wait 4 seconds and the screen will automatically go to the main Options screen. AdvisorOne Quick Operation Guide 3

To set the date and time: 1. From the Settings screen, press CONFIGURATION. 2. Enter Master user code. Note: The Access Granted screen will appear. Press OK or wait 4 seconds and the screen will automatically go to the Global Options screen. 3. From the main Options screen, press TIME DATE. 4. From the Date/time settings screen, press the up and down arrows next to Year, Month, and Day to set the Date. 5. From the Date/time settings screen, press the up and down arrows next to Hours, Minutes, and Seconds to set the Time. User codes User codes are needed to perform certain system functions, such as arming and disarming the system or programming certain system functions. Contact the dealer about what system functions require a user code. Note: Disarming the system will always require an user code. To add a user code: 1. From the main Options screen, press USERS. 2. From the Users screen, press USERS. 3. From the list of users screen, press ADD. 4. From the User Configuration screen, enter the user name and user pin number. 5. Press CONTINUE to save changes and exit the User Configuration screen. 6. Press CLOSE twice to exit the Users screen and return to the main Options screen. Note: The duress code, when used in place of another user code, generates a silent duress alarm that is reported to the central monitoring station. Contact the dealer for more information. Life safety AdvisorOne as a life safety system detects, controls, and informs of security and life safety conditions in the home. Emergency icon To send an emergency alarm: 1. Press. 2. Press the appropriate alarm (Fire, Police, or Auxiliary). Note: Fire alarms are sent instantly. Police and auxiliary alarms could be delayed. Contact the dealer for more information. Note: If the system is connected to a security monitoring service, the authorities will be notified. This option may not be enabled. Contact the dealer for details. Priority of signaling is 1. Fire, 2. Police, 3. Auxiliary. 4 AdvisorOne Quick Operation Guide

If an emergency alarm is initiated by mistake: 1. Press. 2. Enter user access code. 3. Press OK from the Alarm Restored screen. 4. Press CLOSE from the Alarms and Faults screen to return to the Main screen. Note: an aborted alarm will result in audible and visual annunciation Note: The alarm screen image above is for a panic alarm. The alarm could be a fire or police alarm. Arming and disarming Use the steps below to arm and disarm the system: To disarm: 1. Press. 2. Enter the code when the keypad screen appears. If an incorrect code is entered, press CLEAR and enter the correct code. To Arm Stay, Arm Night, or Arm Away: See Table 1 on page 2 for more information. 1. Press. 2. Set arming options. To display arming options, press SHOW OPTIONS. To hide arming options, press HIDE OPTIONS. 3. Press ARM STAY, ARM NIGHT, or ARM AWAY. Note: If no trouble conditions exist, proceed to step 6. 5. From the Arm Protest screen, press BYPASS next to any devices that need to be bypassed. 6. The arming countdown screen will appear. To cancel arming, press CANCEL in the top right corner of the countdown screen. Note: Entry & exit delay beeps sound once a second until the last 10 seconds when the beeps sound twice a second. Exit delay - Turn this option ON to enable the exit delay. Silent exit. Turn this option ON to silence the exit beeps during arming. Exit/entry delay AdvisorOne provides a delay after entering or exiting the premises before the system is armed or disarmed. An exit time restart feature will recognize when the system is armed, a person leaves the premises and quickly reenters The system will restart the exit delay to give users the full exit delay again. The restart will only occur once. Double knock Double knock (two-trip) refers to a zone needing two sensor trips (one or multiple sensors) to be present to generate an alarm. If the zone becomes active and would normally trigger an alarm, either the zone needs to remain active for the programmed Double Knock time or the zone has to return to normal and trigger again within the Double Knock interval before sending an alarm to the central station. Fire alarm verification If this option is off, the panel immediately reports to the central station when a smoke detector goes into alarm. With this option on, if a single smoke detector goes into alarm, the panel will not report for 60 seconds unless another smoke detector goes into alarm. If the first smoke detector is cleared of an alarm within the first 60 seconds, no report will be sent to the central station unless it or a second smoke detector goes into alarm within the panel siren timeout period (5 minutes). Contact the dealer for more information. AdvisorOne Quick Operation Guide 5

Call waiting To help prevent a call waiting option on the phone service interfering with an alarm, this option will be turned on if the panel reports to a central station and the phone system has a call waiting service. Contact the dealer for more information. Unvacated premises Unvacated premises is a feature that determines whether the system automatically arms down to Stay (perimeter sensors are armed. Interior sensors are disarmed) if the system is armed to Away (perimeter and interior sensors are active) without opening or closing a perimeter door (on), or remains at the armed level chosen (off). This feature does not work from a key fob. Autobypass must be on for this feature to work. Contact the dealer to see how these options are programmed. Swinger Shutdown This setting determines if a sensor or zone will go into alarm twice during an arming period (an active arming level) and will not be active again until the alarm is canceled (Swinger Shutdown is enabled) or the sensor has not been activated for 8 hours or zone will always be active and will go into alarm multiple times during an arming period (an active arming level) without canceling the alarm (Swinger Shutdown is disabled). Contact the dealer for more information. Note: Swinger Shutdown does not affect Smoke, Fire, Carbon Monoxide and Environmental sensors. Alarms The system provides annunciation to indicate an alarm condition. When an alarm is active, the Main screen will display the alarm status (see Table 1 on page 2). To cancel an alarm To view additional alarm information, press from the Main screen, then press EVENTS. To cancel the alarm, press and enter a valid user code. Alarm Aborted will be spoken and displayed. The alarm cancel window is the amount of time the user has to cancel an alarm before it is reported. The amount of time to cancel an alarm before it is reported to the central station is 15-60 seconds. Contact the dealer for more information. After alarms are canceled, the system will be disarmed. Status beeps need to update The panel sounds status beeps to alert to various system events and conditions as shown in Table 4 below. A trouble condition will be indicated by a flashing exclamation point over the status shield. Pressing the status shield will display the condition. Table 4: Status beeps Activity Arm Stay Arm Night Arm Away Disarm Chime Property/asset management Trouble beeps RF Jam No activity beeps Beep response Three beeps verify that motion sensors are armed. Two beeps verify that door/window sensors are armed. Four beeps verify that door/window and motion sensors are armed. One beep indicates the system is disarmed. Two beeps. One beep. (Information displays on the touchscreen). Six beeps every minute. Press Listen next to Panel Status to stop beeps for 4 hours. Trouble beeps and RF Jam Fault displayed TBD 6 AdvisorOne Quick Operation Guide

Alarm sirens Exterior and interior sirens make three different alarm sounds on the premises, each indicating a different type of alarm. Sirens are programmed by the installer to time out and stop sounding after a specified time. Consult with your installer to determine if your system is configured with a communicator delay. A communicator delay will prevent a report to the central station if the control panel is disarmed within 30-45 seconds after an intrusion alarm is triggered. Note that fire-type alarms are normally reported without a delay. Table 5 below describes the siren sounds used by the security system. Table 5: Siren sounds Function Fire ( set to 5min per UL Canada) CO Detector Intrusion Emergency Interior and panel siren Temporal 3 Temporal 4 Steady Fast on/off Exterior siren Temporal 3 Temporal 4 Steady Notes: Alarms will not be transmitted in test mode. Temporal 3 refers to a continuous pattern of three siren pulses, then off for 1.5 seconds, three siren pulses, then off for 1.5 seconds. Auxiliary/Emergency alarms have not been evaluated for medical applications by UL and should not be used for medical emergencies. Devices that are not UL Listed are not for UL applications. Among these may include unlisted water detection devices, environmental sensors, key fobs, asset management devices, garage door openers, electric gate, motors etc. System tests The system should be tested every week. Sensor test Sensors should be tested one at a time to make sure they are sending strong signals to the panel. Sensors should be tested at least once a week. To perform the sensor test: 1. Place all sensors in their secured (non alarm) state. 2. From the main Options screen, press TESTS. 3. From the Testing screen, press SENSORS. 4. Trip the sensor (see Table below). The signal level is recorded under the sensor on the Sensors screen. Table 6: Tripping sensors for sensor test Sensor Instructions Minimum packets required Hardwire contact Open the hardwire contact. 1 Door/window Open the secured door or window. 6 of 8 Carbon monoxide alarm Press and hold the Test/Hush button (approximately 5 seconds) until the unit beeps two times, and then release the button. 6 of 8 Glassbreak Test with an appropriate glass break sensor tester. 6 of 8 Motion sensor Avoid the motion sensor field of view for 5 minutes, and then enter its view. 6 of 8 Wireless Smoke Press and hold the test button until the system sounds transmission beeps. 6 of 8 Key fob Press and hold the Lock and Unlock buttons simultaneously for 3 seconds. 6 of 8 AdvisorOne Quick Operation Guide 7

Note: Refer to specific sensor installation instructions for complete operation and testing details. If all sensors have not been tested, the test mode will time out and the panel will return to normal in 15 min. Communication test To test communication with the central station: 1. Call the central station and tell the operator that the system will be tested. 2. Arm the system. 3. Test an emergency icon (Fire, Police, or Auxiliary) and trip at least one sensor of each type (fire, intrusion, etc.) to verify that the appropriate alarms are working correctly. There could be a delay on intrusion devices. 4. When finished testing the system, call the central station to verify that the alarms were received and instruct them to resume monitoring the system. Note: If the system is not connected to a central monitoring station, the central station communication test will not be available. Emergency planning Periodically discuss and rehearse emergency plans to include the following: Understand how to use the security system. Check with the dealer to make sure smoke detectors are located on each floor of the premises. Know the normal state of doors and windows: open, closed, or locked. Escape fast! (Do not stop to pack). Use a different escape route if closed doors feel hot to the touch. Crawl and hold your breath as much as possible to help reduce smoke inhalation during an escape. Meet at a designated outdoor location. Emphasize that no one should return to the premises if there is a fire. Notify the fire department from a neighbor s phone. Emphasize that no one should enter the premises if they hear sirens in the house. If you arrive at the premises and hear sirens, do not enter. Call for emergency from a cell phone or neighbor s phone. Use the following guidelines when drawing your floor plan: Show all building levels. Show exits from each room (two per room are recommended). Show the location of all security system components. Show the location of any fire extinguishers. Smoke detector placement Maintenance & support This system is intended to be checked by a qualified technician at least once every 3 years. Contact the dealer for battery replacement needs. 8 AdvisorOne Quick Operation Guide

Cleaning the touch screen If necessary, use a soft cloth to clear smudges on the touch screen; do not use glass cleaner on the touch screen. Disposal Dispose of all equipment is accordance with local requirements. Contact the dealer for more information. Support There may be additional features or programming options for the system depending on how it was installed. Contact the dealer or Interlogix for more information. Industry Canada Compliance IC ID: 1175C-AVO1037 This Class B digital apparatus complies with Canadian ICES-003. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. FCC Compliance Part 68. This equipment complies with Part 68 of the FCC rules and the requirements adopted by ACTA. FCC registration number: US: B4ZAL04B55972 Ranger Equivalence 0.2B Load Number 0.2 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Changes or modifications not expressly approved by UTC Fire and Security Americas Corporation, Inc. could void the user s authority to operate the equipment. Contact information www.utcfireandsecurity.com or www.interlogix.com For customer support, see www.interlogix.com/customer-support 2013 UTC Fire & Security Americas Corporation, Inc. Interlogix is part of UTC Climate Controls & Security, a unit of United Technologies Corporation. All rights reserved. AdvisorOne Quick Operation Guide 9

Canadian French: Quick Operation Guide Spanish: Quick Operation Guide Portuguese: Quick Operation Guide 10 AdvisorOne Quick Operation Guide