UN Test Report - ASM P/N 45N1010 (Nom. 94Wh, 11.1V)-

Similar documents
UN Test Report - ASM P/N 45N1028 (Nom. 94Wh, 11.1V)-

UN Test Report - ASM P/N 42T4946, ASM P/N 42T4956 (Nom. 32Wh, 11.1V)-

UN Test Report - ASM P/N 42T4882 (Nom. 63Wh, 11.1V)-

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

1. Chemical Product and Company Identification

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Vibration tests on a TNAML Luminaire

Test Methods for Consideration Into Radio Standard

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

DP86 Constant Voltage with Fitting

ENVIRONMENTAL TEST REPORT

environmental chambers for Battery testing

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

JUL 18 Rev A1

OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION

/Mar/2014 Rev A

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

Product Tests Report

Mar11 Rev C

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618

USB 3.0 Plug & Receptacle

Mar11 Rev B

environmental chambers for Battery testing

Battery Design Considerations

PERMANENT DOCUMENT. Annex AD to Routine Test Requirements for manufacturers (as per Article 9 of the Agreement)

COMITÉ EUROPÉEN DES ASSURANCES

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Residual Current Devices

A Review of America s First Step Towards the Harmonization of Portable Battery Standards: UL 62133

INTERNATIONAL STANDARD

Battery Design Considerations

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Products for Secondary Battery Market

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

Product Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5

M7100 Pressure Transducer

DRAFT TANZANIA STANDARD

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

KILOVAC K1K High-Voltage Contactor

Laser Collimated Beam Sensor

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

D5100 Industrial Differential Pressure Transducer

Technical Specification for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C)

FOS WATER LOW FOG 3000

DECOMMISSIONING OF THE REACTOR VESSEL OF THE COMPACT SODIUM COOLED NUCLEAR REACTOR FACILITY (KNK)

APR 17 Rev A

Osram OT 40 OT 60 OT 90 4DIMLT2 E LED Drivers Conformity check to Synergrid C4/10

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Vacuum suction nozzle OVEM-...-1P/1N

SENTINEL A - Fault Passage Indicator

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

EAE/EAES «HEPHEA 248» Product Technical Instructions

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

INTERNATIONAL STANDARD

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

FIS30XXseries Gas sensor module SPECIFICATIONS

DYNAMICS WHILE DRILLING DWD SOLUTIONS LODESTARINT.COM

Technical Specification for the Gel-Sealed Fiber-Optic Closure System (FOSC 450)

Part 3 Troubleshooting

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

ISO INTERNATIONAL STANDARD. Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions

Emergency Lighting Control Gear Combo Economy Version (2 in 1)

TB/T Translated English of Chinese Standard: TB/T RAILWAY INDUSTRY STANDARD

1 Appendix - Product Specifications

Environment Test Report

Products for Secondary Battery Production and Testing

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

Table 1. Serie of Digital Room Thermostats.

Digital Heater Element Burnout Detector K8AC-H

TECHNICAL REPORT Crimp Splice Protection -250M/P150 mark 2

D5100 Industrial Differential Pressure Transducer

Accumulated Battery JULY The electronic pdf version of this document found through is the officially binding version

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Step by Step Detailed Procedure Expected Result Observations Verify power off at all loads on emergency power. Verify all loads have power.

Event Monitoring Device (EMD)

Technical Data Sheet Opto Interrupter ITR

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

The New Battery Safety Standard EN for LEV s. Stephan Scheuer TÜV Rheinland

Installation Instructions for W2H Series Signals

EVAPORATIVE AIR COOLER

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Qualification Test Report LC Duplex Adapter For LC Cutouts

ABB. Modular contactors. Contents

AUR300C. Advanced Ultraviolet Burner Controller

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Equipment Required. WaveRunner Zi series Oscilloscope 10:1 High impedance passive probe. 3. Turn off channel 2.

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

Rules for Intruder Alarm Systems

SENTINEL D - Fault Passage Monitoring

Transcription:

문서번호 Prepared Reviewed Approved QAEEF02111013PKASMP/N45N1010 김홍일남익현이문규남대호최운기정준용 UN Test Report ASM P/N 45N1010 (Nom. 94Wh, 11.1V) 목차 1. UN Transportation Regulation Test 2. Test Procedure 3. Test 4. Sample Image 2011. 10. 13

1. UN Transportation Regulation Test Test Test 1. Altitude Simulation Test 2. Thermal Test Test 3. Vibration Test 4. Shock Test 5. External Short Circuit Test 6. Impact Condition Storing at (low pressure)11.6kpa for 6hr at 20+/5 [5± 2,6hr 40±2,6hr,interval max. 30min] x 10cycle Storing at 20± 5 for 24h [Hz 200Hz Hz, in 15min] x 12 times x 3 direction 1) sinusoidal waveform with a logarithmic sweep 2) Hz 18Hz (maintaining 1gn) app. 50Hz (until 8gn) 200Hz (maintaining 8gn), 1.6mm total excursion Half sine shock (peak acceleration : 150gn, pulse duration : 6msec) x 6 (± x, y, z) direction x 3 cycle 100mΩ ext. shortcircuit at 55± 2 1hr continue after returning at 55± 2 Φ=15.8mm bar, 9.1kg mass, 61± 2.5cm height s Measuring mass before/ after each test (If M>5g, less than 0.1%) Measuring voltage before/ after each test (more than 90%) No leakage, no venting, no disassembly, no rupture, no fire No disassembly, no rupture, no fire (after 6 hours) Temp. monitoring (max. 10 ) Test. Overcharge Current = Manufacturer s recommended max. continuous charge current X 2 Voltage 1.If charge voltage 18V, V (min.) = 2 x (max. charge voltage) or V (min.) = 22V. 2.If charge voltage > 18V, V (min.) = 1.2 x (max. charge voltage) No disassembly, no fire (after days) Test 8. Forced Discharge Only for Cell, not battery. No disassembly, no fire (after days) * Tests through T1T5 shall be conducted in sequence with the same battery. * We declare that the abovementioned test is the result of being checked according to UN Test (Manual of Test and Criteria ST/SG/AC.10/11/Rev.5) 1 / 6

2. Test Procedure Sample Sample Preparation Preparation Forced discharge test is required to cell level, not pack battery level. 4 ea 1 st cycle d 4 ea 50 th cycle d Test 1 Test 1 Altitude Altitude Simulation Simulation Test 2 Test 2 Thermal Test Thermal Test Test 3 Test 3 Vibration Vibration 10ea 1 st cycle 50% d For cylindrical cells, 5 test cells are required. Test 6 Test 6 Impact Impact Test Test Overcharge Overcharge 4 ea 1 st cycle d 4 ea 50 th cycle d Test 8 Forced Discharge * 10ea 1 st cycle Discharged 10ea 50 th cycle Discharged Test 4 Test 4 Shock Shock Test 5 Test 5 Ext. Ext. Short Short Circuit Circuit Report Report 2 / 6

31. T1T4 Test Before Altitude (T1) Thermal (T2) Vibration (T3) Shock (T4) Residual (%) Loss(%) Residual (%) Loss(%) Residual (%) Loss(%) Residual (%) Loss(%) A. 1st cycle fully state 1 12.191 505.495 12.184 505.490 12.1 505.483 12.12 505.44 12.164 505.40 2 12.14 504.593 12.140 504.585 12.136 504.582 99.9 12.130 504.5 12.121 504.568 3 12.152 505.692 12.142 505.681 12.138 505.60 99.9 12.129 505.661 12.125 505.653 99.9 4 12.185 506.485 12.18 506.482 12.10 506.469 12.166 506.463 99.9 506.460 Ave. 12.169 505.566 505.560 12.155 505.551 12.149 505.544 12.143 505.538 B. 50th cycle fully state 5 12.145 505.485 12.13 505.43 12.130 505.468 12.122 505.462 12.104 505.454 99.85 6 12.196 505.562 12.19 505.554 99.86 12.166 505.548 99.89 12.153 505.538 99.89 12.148 505.531 12.16 504.854 504.850 12.158 504.836 99.98 12.14 504.828 99.91 12.142 504.816 8 12.134 505.898 12.125 505.881 12.11 505.80 12.110 505.855 12.101 505.839 Ave. 505.450 12.151 505.440 12.143 505.431 12.133 505.421 12.124 505.410 Measuring mass before/after each test (If M>5g, less than 0.1%) Measuring voltage before/after each test (more than 90%, only charged samples) No leakage, no venting, no disassembly, no rupture, no fire 3 / 6

32. T5/T Test EXT.Short Circuit (T5) EXT.Short Circuit (T5) (V) (V) A. 1st cycle fully state B. 50th cycle fully state 1 12.164 55.43 5 12.104 55.25 2 12.121 55.04 6 12.148 54.6 3 12.125 54.99 12.142 55.38 4 55.3 8 12.101 55.03 12.164 55.3 12.148 55.38 Test Condition 100mΩ ext. shortcircuit at 55±2 Temperature < 10 No disassembly, no rupture, no fire within 6 hours Over (T) Over (T) (V) (V) A. 1st cycle fully state B. 50th cycle fully state 9 12.421 25.13 13 12.333 24.99 10 12.386 25.29 14 12.362 25.01 11 12.491 25.21 15 12.298 25.11 12 12.433 25.3 16 12.309 25.19 12.491 25.3 12.362 25.19 Test Condition Max. Current : 4000 ma CC/CV 2Imax(8000mA) 22V cutoff 24Hr No disassembly, no fire within day 4 / 6

33. T6 Test (ICR18650C2) Impact (T6) (V) A. 1st cycle 50% charge state 21 3.80 25.43 22 3.80 108.50 23 3.806 24.36 24 3.806 24.9 25 3.806 114.39 3.80 114.39 B. 50th cycle fully discharge state 26 3.351 24.83 2 3.362 46.43 28 3.38 49.26 29 3.369 49.90 30 3.353 4.55 3.38 49.90 Test Condition Φ=15.8mm bar, 9.1kg mass, 61±2.5cm height Temperature < 10 No disassembly, no rupture, no fire within 6 hours 5 / 6

4. Sample Image 6 / 6