Design Benefits and Advantages:

Similar documents
This series is utilized for waste streams which are not prone to hardening in the presence of liquid solvent, and provides ease of residue removal.

Washing Systems for Pails, Buckets and Jars

SRS Engineering offers the TW-Series (tote washer / tank washer) designed to work with metal or plastic totes or tanks with maximum opening of 80".

The DWC-Series - Drum Washer / Crusher Unit

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

CONTROL SYSTEM D ESIGN, E NGINEERING & C ONSTRUCTION.

When reliability is vital. Alemite Carbon Shield TM Systems deliver

LS-JRE OPERATION & INSTRUCTION MANUAL

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

GIRTON TREE, TUB, AND CART WASHER MODEL 80-O

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

1.1 Controller General Information

IBC Wash: Critical Cleaning Solution for IBCs, Totes and Tablet Bins.

Analyze IT. Process Gas Chromatograph. PGC2000 Series

Allen Bradley Plc Training Manual

OPERATION & MAINTENANACE MANUAL

LS Series Solvent Recovery Systems

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

Dual Tower Heat Reactivated Desiccant Air Dryer

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

266-CS-TMS-E-2008 Automation & Instrumentation Engineer. PERSONAL DATA Nationality : Egyptian Birth Date : 23/08/1986

Across-the-Line SERIES MP300 Combined Manual and Automatic

Power Flame Incorporated

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR


cgmp STEAM STERILIZERS

GIRTON CABINET WASHER MODEL 794A

Insert Photo Here Bos Howard Johns Manville

Distillation Systems for Solvent Recycling

PRODUCT REVIEW Honeywell HC900 Hybrid Vacuum Furnace Control System

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task.

Soft Start Series MP700 Solid State, Reduced Voltage

TM Series. Induced Draft, Counter Flow Optional Accessories

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Central Chillers TS Series

i-temp MAX Up to 150 C 12 to 360kW

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

OAM Purger. Oil Acid & Moisture Purge Unit. Redi Controls, Inc. Installation, Operation & Maintenance Manual. High Pressure Centrifugal Chillers

ECOPlus SERIES OF HIGH-PRESSURE METERING MACHINES

Process Control & Automation

Remote Alarm Monitoring Alarm monitoring includes Global Remote Alarm Relay. Capabilities independent port can be used

PROBATCH MODEL H. Optimize Your Polymer Performance

SmartVFD HVAC and BYPASS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Reliable, Compact Systems with Complete Flexibility in Customization and Design

Foundation Fieldbus Usability from field Device Perspective. Hemal Desai Endress+Hauser India Pvt. Ltd 16 th October 2014 Automation 2014 Mumbai

OPERATING INSTRUCTIONS AND SAFETY PRECAUTIONS WASHER-EXTRACTOR WARNING

Open the Door to Increased Productivity and Cost Efficiency

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

LQ AQ SQ. Air-cooled and water-cooled portable chillers

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

Water treatment made easy! Evaporators for the treatment of industrial wastewater.

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

- Data Brochure Steam Control 279

Premium Efficient OIL-FREE Compressors

The Experts in Vacuum Solutions

SENTRA Series Water Unit

Pulse Firing Doubles Capacity and Cuts Fuel Costs

Commercial Semi-Instantaneous Water Heaters

Intelligent. Evaporation. Premium Safety Standards Superior Ease of Use Reduced Cost of Ownership

C1N & C2N SERIES Fluid heating for light industrial applications

Model GW1020 Laboratory Glassware Washer General Specifications

Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership. Intelligent. Evaporation

A Complete Package That Includes:

Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership. Intelligent. Evaporation

AccuBrine automated brine maker Technical Specifications

HEAT TREAT EQUIPMENT Quality Used Heat Treating Equipment Item V-1062 Furnace Super 36 Allcase IQ, 36x72x36

WASTE WATER EVAPORATOR WITH ANY FUEL OPTIONS

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

This guide will discuss the scope of work, and technical requirements of connecting to the Energy Transfer Station(s) (herein referred to as ETS).

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

TYPICAL CPA SPECIFICATIONS

LTFX Electric Tank Immersion Heaters Installation Instructions

All rights for changes reserved that lead to technical improvement. kolb GmbH 2017

Enteral Pump Instructions for Use To Assemble When the low

Intelligent. Evaporation.... no task too big

STEAM STERILIZER SERIE S1000 (RBE)

Operation and Maintenance Haskris LX-Series, R-Series, WW-Series, OPC-Series

Order by phone Order on-line Order by fax Website

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

Power Flame Incorporated

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

One Operator Bottling.

LQ AQ SQ. Air-cooled and water-cooled portable chillers

High Capacity Instantaneous Steam Fired Water Heater

Flex separation systems, P-separators 605/615

Paragon. Induced Draft, Counter Flow Optional Accessories

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

McNeil Group University of Michigan. MBraun Glovebox. Preparing Items To Be Brought Into the Glovebox

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

Revitalize Building Mechanical Systems (4619)

Precise Temperature Control; Compact Footprint

Landfill & Digester Gas Dryers. Features and Benefits

- Data Brochure D 260. Boiler Control /09

- Data Brochure Boiler Control 264e

Transcription:

The SRH-Series is designed for system sizes handling 25-250 gallons per hour and features scrapers and immersion heaters in a large capacity oil bath. The system incorporates a self adjusting scraper unit like the one in the SRS Series unit and provides the same performance reasons. The hot oil media consists of a large volume chamber surrounding the distillation chamber which is heated via two electric immersion heaters or optional steam coils. Because of the relatively large volume of oil involved, this simple and trouble free design minimizes hot spots and results in a very efficient distillation process. An optional auto cool system is achieved by circulating cooling water through coils in the oil bath. Design Benefits and Advantages: Vessel Design: Unlike typical flat bottom or straight side, dished bottom stills, SRS provides a true cone vessel. Models SRH have 60 cone vessels. This design allows proper heat distribution and ease of residue removal. This design has more heat transfer area at the top of the cone. As sludge accumulates, it naturally drops to the bottom of the cone leaving the larger surface area at the top to keep on distilling at optimal efficiency. Under these conditions, the sludge is always submerged in solvent and acts as an additional safety feature with reactive materials such as nitrocellulose. PLC controls: SRS offers an assortment PLC systems. All programs and listings are made available to the user for on-going maintenance. Set points and temperature ranges are preset at the factory, and are protected by password access. This password control is passed on to the user to be used only by authorized personnel. Self Adjusting Scraper Blades: Model SRH. The unique self aligning, flexible wrist design assures proper leading edge scraping of the vessel heated surface. This ensures a continuous contact with the inner walls of the unit at all times, requiring no external adjustments. The support hub is located above the residue discharge area to prevent interference during discharge. The massiveness of the wear surface provides long life. Material of Construction: Both the vessel walls and the outer shell are stainless steel. The elevated stand, platform and ladder are also of stainless steel. High Efficient Condenser: Made of stainless steel type 316, the Flat Plate design provides exceptional heat transfer area thus establishing an efficiency rating far above the standard shell and tube condenser designs.

Precise Temperature Controls: RTD temperature sensors are provided in the vapor space, heating medium and the sludge and are monitored and controlled within a pre-determined range by the PLC. RTD s are accurate to within 1 to 2 degrees F. Sludge temperature control is the only accurate way to establish its consistency, since it becomes hotter as it thickens. Discharge condition is controlled accurately through this temperature sensing, initiating auto cool down cycle which alerts the operator to empty the residue. Sludge temperature control is key to the safe distillation of waste solvent contaminated with nitrocellulose. Auto Cool: For operator safety and VOC minimization, all SRS systems are available with an auto cool option. Before discharging, the sludge should be rapidly cooled to a safe temperature, typically from 100-150 degrees F. After discharge, the system is immediately ready to be reloaded with solvent to continue the process. This shortens the discharge time by several hours for a more effective use of the system. Heating Methods: The SRH Series Model utilizes a self contained heating system with immersed electric heaters or steam coils in a high volume oil bath. Cooling of the residue is accomplished by circulating a cooling medium through coils in the oil bath. Vacuum: Optional vacuum systems with a secondary condenser for maximum VOC control. Includes a 3 HP Liquid Ring vacuum pump, decanter, sight glass under PLC control. A secondary condenser is used to virtually eliminate VOC emissions from the vacuum system. The vacuum is mounted on the distillation system to reduce the effective boiling temperature for safety and efficiency. An added benefit of this vacuum system is the fact that it can be used in the auto load operation instead of a pump. Auto Fill: Vacuum fill or optional pump fill system with electronic level sensor to maintain operational level within the distillation vessel. In addition to the level sensor control, all SRS systems have a secondary level of safety by incorporating a PLC driven watch dog timer feature, which stops the auto fill action upon the expiration of the allocated time, both for an initial fill (typically 10 minutes) and consequent refills (typically 2 minutes). This ensures against accidental overfilling. Sludge Discharge: All series of distillation units use a bottom mounted large capacity 6 or 8 manually operated discharge valves. Class 1, Division 1 or ATEX Option for Hazardous applications: Explosion resistant air (or nitrogen) purged NEMA 4X Control Panel with pressure differential sensor mounted on a NEMA 7X junction box. Purge pressure loss sensed through the PLC will shut power off to the unit. NEMA 7 compatible junction boxes, conduits and components are utilized. Nitrocellulose Package: Present The Nitrocellulose control package is required when Nitrocellulose is present in materials being distilled to prevent a Nitrocellulose Reaction typically found in the printing industry.

Additional Operating and Safety Features: 1. Full function digital display with clear status and fault messages 2. Interlocking safety devices on all components. 3. Explosion resistant designs and components. 4. 5 PSI pressure relief valve. Single Point Utilities Connections: Minimal installation time and cost. Units are skid mounted, pre-shipment assembled and tested. All systems are wet tested at the factory before shipment. Solvent Tank Designs: SRS offers conical bottom vertical tank designs (typically 500 gallons) fabricated of 304 stainless steel, which feature small footprints for optimal use of space. Optional recirculating and fill pumps can be fitted to the dirty solvent tank to keep solid sludge from building up at the bottom. Automated transfer pumps are available to suit the application. All tanks have clean out hatches, venting ports, a sight glass, and accommodations for three level sensors. This system utilizes a Closed Loop System configuration. Operating Control Systems SRS' automatic systems are equipped with a Programmable Logic Controller (PLC). The user interface prompts the operator through comprehensive menus to set up the operating system functions. This enables the PLC to operate the system automatically while providing displayed current status information. The PLC monitors system and auxilary equipment sensors, flow rates, temperatures, fault conditions, and contacts to verify proper grounding, before initiating the start function. Fault conditions are diagnosed and clearly displayed on the HMI, to ensure operator safety and ease of operation. The unit will systematically shut down in a fail safe mode in the event of a fault condition or at the end of the cycle.

DCS PLC HMI ABB Bailey INFI 90 ABB Fischer & Porter DCI Allen-Bradley ProcessLogix Delta V Fisher-Rosemount RS3 Honeywell TDC/TPS Systems Honeywell Plantscape Honeywell Experion Siemens Simantic PCS Siemens Moore APACS Allen-Bradley SLC Allen-Bradley PLC5 Allen-Bradley ControlLogix Allen-Bradley MicroLogix General Electric 90/70 Koyo DirectLogic Modicon Quantum Modicon 884/984 Siemens APT Siemens S7 Mitsubishi Allen-Bradley - PanelView Rockwell - RSView, RSBatch Siemens - WinCC, OSx Wonderware - InTouch, InTrack, InControl, InBatch, InSQL