Liebert InteleCool Warranty Inspection Check Sheet

Similar documents
Liebert DataMate (1-3 Ton) Warranty Inspection Check Sheet

Liebert CRV Warranty Inspection Check Sheet

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

Liebert Xtreme Density Chiller (XDC) Unit Warranty Inspection Check Sheet

Liebert Small System MCD and PFH Condensers (1-5 Ton) Warranty Inspection Check Sheet

Service Step by Step Trouble-Shooting Check-List

Installation, Operation, and Maintenance Manual

Installation, Operating & Maintenance Instructions. Air Handler Models: AH & AV

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Installation, Operating & Maintenance Instructions. Horizontal Models: LH & HL

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

/ No. (\01. la-ejl~ Withthe MainDisconnectOFFcheckthe following: Owner Address I~O ~.Cc:t\". ~\\A. Contact Name, Contact Telephone # Installation Date

BasicTroubleshooting Information and Guidelines

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

SA Series Start up Report

Bug Killers. Read all instructions before using the bug killer. Contents

BK17 Heater. Read all instructions before using the heater. Contents

Panel Fan Series Operators Manual (Galvanized and Polymer)

BK5 Bug Killer. Read all instructions before using the bug killer. Contents

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

Installation Instructions

Bottom Mount Refrigerator---Technical Information

Locally Controlled Bug Killers. Read all instructions before using the bug killer. Contents

Liebert Challenger 3000/Liebert Challenger ITR with Liebert icom Control. Operation & Maintenance Manual - 50 & 60Hz

Installation Instructions

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Installation Instructions

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

Construction Standards Page

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

CAUTION. No-Load Performance, Controls in Normal Position

HX18 Heater. Read all instructions before using the heater. Contents

Verde GSE PCA Bridge and Ground Mount Units 30/45/60/90/120 Tons. Installation and Maintenance Manual

Installation, Operation & Service Manual

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

Installation Instructions

L A signature series TA T N E RE O, A L L A T S IN

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Indirect gas-fired air heater

MIST MAX MODEL MM800. Important: Installation and Operation Manual

Installation & Maintenance Instructions

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

OPERATING INSTRUCTIONS MANUAL FLE-150 INDUSTRIAL / COMMERCIAL ELECTRIC HEATER (OPERATOR MUST RETAIN FOR FUTURE REFERENCE)

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

Field Start-Up Sheet Direct Fired Gas Equipment

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

ELECTRIC BODY SAW INSTRUCTIONS. Item #31660

Residential Steam Humidifier

MANUAL INSTALLATION. Fan Column. v200 Issue Date: 01/18/ Price Industries Limited. All rights reserved.

Ducted Propeller. Airflow Volume

CENTRAL, SPLIT SYSTEM REFRIGERATED AIR-CONDITIONING INSPECTION INTERIOR

Model No. Serial No. Original Purchaser. Address. City and State Zip. Dealer. Address. City and State Zip. Installation Date Name Signature

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

Installation Owner Diagnostics

Welcome to the Ice-O-Matic on-line training modules. Ice. Pure and Simple

AXPR Wall Mounted Axial Panel Fans

Installation Instructions

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Installation Instructions

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10%

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH

OPERATING INSTRUCTIONS MANUAL FLE-60 INDUSTRIAL / COMMERCIAL ELECTRIC HEATER (OPERATOR MUST RETAIN FOR FUTURE REFERENCE)

ECM OPERATION MANUAL

Installation, Operation and Maintenance Manual

For an administrative fee of $9.97, you can get an un-locked, printable version of this book.

SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

Safety & Installation Instructions

A/C-HEATER SYSTEM - MANUAL

HX150 OPERATOR S MANUAL. 150 kw HEATER

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

Owner s Manual Guide du propriétaire Manual de Usuario. H Rev -

DISPOSER CONTROL CENTER

Installation and Maintenance Manual IM 1102

PRESIDENT POPCORN MACHINE SERVICE MANUAL

Modular Packaged Unit Installation, Operation and Maintenance Manual. Modular Packaged Cooling Unit

Preventative Maintenance Tables

Installation, Operating & Maintenance Instructions. High Performance Horizontal Models: HH & CH

User s Information Manual

Installation Instructions

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Intelligent Electronic Enclosure Thermal Management Systems

Transcription:

The following information must be fully completed and forwarded to your local Liebert sales office to establish your equipment warranty. Installer _ Address Owner Address Owner e-mail address Installation Date Was the unit received in good condition? Yes No If no, has the carrier been notified? Yes No Have the manuals been kept with unit? Yes No PRE-START-UP InteleCool Serial Number: _ InteleCool Model Number: _ Compressor Serial Number Compressor Model Number Page 1 of 5 Rev. 3 10/2015

Arc flash and electric shock hazard. Open all local and remote electric power disconnect switches, verify with a voltmeter that power is off and wear personal protective equipment per NFPA 70E before working within the electric control enclosure or any hazardous voltage electric connection enclosure. Failure to comply can cause serious injury or death. With the electric power to the unit OFF check the following items as noted: Internal piping clamps tight and secure. ALL electrical connections are tight and properly terminated. Equipment is installed level. Remove all debris from unit area. Drain lines are open and clear of dirt and debris. Duct work is complete, and secured. Filters are installed in the unit? Filter Size Quantity Blower drive system rotates freely. Main fan HP Page 2 of 5

Inspection Risk of electric shock, contact with high speed moving parts and hot surfaces, Can cause serious injury or death. Use extreme caution when working inside the unit cabinet of an energized unit near bare live hazardous voltage terminals, high speed moving parts such as blower wheels and shafts, pulleys, belts, EC fan blades and hot surfaces such as motors, heater elements, hot gas lines, and humidifier bottles. 1. Check voltage at disconnect and record. L1-L2 (If Applicable) L2-L3 (If Applicable) L1-L3 2. Close all local and remote electric power disconnect switches. Verify with a voltmeter that power is on and the supply voltage matches the marked unit voltage rating. Arc flash and electric shock hazard. Wear personal protective equipment per NFPA 70E before working within the electric control enclosure or any hazardous voltage electric connection enclosure. Use extreme caution when checking the status of live hazardous voltage circuits. Failure to comply can cause serious injury or death. Check unit electrical phasing with a phase meter. If phasing is incorrect, change wiring at input source to unit. Do not change any unit or component phasing. Check the compressors for proper rotation by bumping the contactors and watching the gauge pressures. If the pressures are equalized and the compressor sounds noisy, then compressor is running backwards. 3. Check and record control voltage transformers for proper output. (Secondary voltage should not be under 23 VAC or exceed 27 VAC under load, change tap if necessary). T1 Volt 4. Enable Fan and record Main Fan amperage. Page 3 of 5

5. Increase temperature to energize the heaters and record amperage. Disable heaters after test. 6. Decrease temperature to energize compressor. 7. Check compressor operating pressures and record. Suction Pressure Discharge Pressure 8. Check superheat on each circuit. (Should be approximately 10-15 ) Superheat 9. Check and record compressor amps. 10. Check and record condenser fan amperage. Page 4 of 5

Your Start-up is now complete. Your input is important to us. Did you encounter any factory or field issues? If YES, please check the YES box and supply detailed description below. If NO, please check the NO box; however please feel free to provide any additional comments or suggestions. YES NO Comments: START-UP PERFORMED BY START-UP DATE (Please print name) COMPANY PHONE # IMPORTANT: This form must be properly completed and returned to your local Liebert Sales office. If you do not know who your local Liebert sales office is, call 1-800-Liebert or check our website at: http://www.emersonnetworkpower.com/en-us/brands/liebert/pages/default.aspx Page 5 of 5