DRAIN WATER TEMPERING INSTALL

Similar documents
WARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.

WARNING DESCRIPTION PART NUMBER QTY PLUMBING, DYNATEMP DRAIN QUENCH BRACKET, THERMOSTAT DRAIN QUENCH

DRAIN WATER TEMPERING INSTALL

DRAIN WATER TEMPERING INSTALL

KIT NOTICE. These instructions are for replacing the two existing thermostats with a single new solid-state thermostat.

AVENGER HT THERMOSTAT RETROFIT INSTRUCTIONS

THERMOSTAT RETROFIT INSTRUCTIONS

KIT NOTICE. These instructions are for replacing the three existing thermostats with a single new solid-state thermostat.

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D.

AJ-44 Rack Conveyor Dishmachine Maintenance Instructions. Changing Conveyor Direction

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

SAVE THESE INSTRUCTIONS

Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Engine Block Heater Service Kits (Tank Type) ROZJ 6076T and 6076A (John Deere Powered Standby Generator Sets)

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

5800 Refrigerator Compressor Capacitor/Relay Kit

A HEATER KIT With Diesel Engine Connection Fittings

Installation Manual PS-200 & PS-201

Installation Instructions

IMPORTANT SAFETY INSTRUCTIONS:

Installation Instructions Built-In Dishwasher

Installation Manual PS-225 & PS-275

WARNING. Tighten strain relief screws to secure cable. Make sure screw heads are facing up when tightening conduit nut.

IMPORTANT SAFETY INSTRUCTIONS:

Installing a Fast Oven Upgrade Kit

Installation Instructions

Installation S

Smart Water Heater Controller

Installation. Leveling

W C. Table of Contents... 2 Table des matières... 25

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions

D1/D2 Direct Vent Pilot Replacement Model #: D INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.

STEAMPRO. Steam Generator Troubleshooting and Service Guide

Commercial Electric Energy Saver Water Heater IMMERSION AND SURFACE MOUNTED THERMOSTAT MODELS

Installation Instructions

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S

CABS/BLADES/ SPREADERS/ACCESSORIES

INSTALLATION INSTRUCTIONS

A B A B4

FIREPLACE INSTALLATION

Handshower, Hose & Handshower Accessories

Dishwasher Installation Instructions DW 24XT/DW 24XV

INSTALLATION INSTRUCTIONS

Instructions. Certifications Chrome 2-handle Chrome 3-handle 10-B83-WCH-AD Chrome 3-handle 10-B82-WCH-AD Chrome 2-handle

Installation Instructions 30 French Door Built-in Wall Ovens

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

Dishwasher. Installation manual DW60M9990AP

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

! WARNING. Before using product, read and understand instructions.

DELTA 1200/115 INSTALLATION, OPERATION, AND SERVICE MANUAL DELTA SERIES GLASSWASHER DISHMACHINES. Delta 1200/115 Manual S

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

Electric Space Heater

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHER PLASTIC TUB INSTRUCCIONES DE INSTALACIÓN LAVAVAJILLAS EMPOTRADA CON TINA PLÁSTICA

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Installation S

Installation S

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS

WATT R TWIN Energy-Efficient Home Water System

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

Cable Drain & Cable Drain Trim Kit

IMAGE V. Parts and Service Manual

PO Box 827 Hawley, MN (218) Fax (218)

25M01A-100 to 25M01A-199 HSI Single Stage Combination Gas Valve

TT /97 WARNING WARNING WARNING INSTALLATION INSTRUCTIONS

Non-RTD Hot Melt Hose Replacement

BURWELL BIDET TOILET SEAT INSTALLATION

Installation Instructions Built-In Dishwasher

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

Retro-DWS Other Methods Internal Heating Cable System for Sewer Pipe and Waste Drain Applications

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

BUNN H5E H5M H5X BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

Installation Instructions

I<enmore Elite. instructions dlnstallation. Installation Guide Instrucciones de Instalaci6n. English / Espafiol/Frangais

Water Distiller Service Manual

V Refrigeration Module

Installation Instructions

TABLE 1 Electrical Specifications. Phase

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

Hoshizaki America, Inc.

Installation Instructions

Installation Manual. Models 99168, 99169, 99170

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Installation Instructions

Step 1: Identify the parts of your shade (parts shown are not to scale)

Installation Instructions

Decorative Low Profile Integrated Kit

MODEL CMA-180UC PARTS MANUAL Rev 1.16

Owner s Guide and Installation Manual

Installation Instructions Air Pump

Light Duty Commercial Electric Voltage and Wattage Conversion Instructions

Installation S19-324D1. Class I, Division 1, Groups C & D Explosion Proof. Emergency Signaling System

Owner s Guide and Installation Manual

INSTALLATION & OPERATING INSTRUCTIONS

Owner s Manual FS-10/FreshSpa

Transcription:

! WARNING! CAUTION DRAIN WATER TEMPERING KIT - 0601-00-07-86 WARNING! This kit should be installed only by qualified service personnel to reduce the risk of electric shock, serious injury, or fire. A plumbing permit and the services of a licensed plumber and electrician might be required in some areas. Turn off the power supply and place the dishwasher disconnect (if applicable) in the off position. Lock-out/Tag-out to prevent the power supply from being turned back on inadvertently. CAUTION! Failure to install this kit within the guidelines might adversely affect safety, performance, component life, and warranty coverage. ITEM 1 2 3 5 6 TOOLS REQUIRED Pipe Wrench Adjustable Wrench 5/16 Nut Driver 3/8 Nut Driver or Wrench Phillips Screwdriver Pipe Thread Sealant Tape Needle-nose Pliers SCHEMATIC The Drain Water Tempering schematic is shown as an option on the machine schematic. PARTS INCLUDED Parts are the same for both units, but configured differently. Two graphics/pictures are shown when there are differences. 6 6 HH-E 1 1 3 5 2 FRONT OF UNIT 3 5 2 ITEM DESCRIPTION PART NUMBER QTY 1 CROSS CONNECTOR, 1 1/2" FEMALE 0710-00-3-65 1 2 NIPPLE, 1 1/2" CLOSE BRASS 0730-207-0-00 1 3 REDUCER, 1 1/2" X 1/" BRASS 0730-002-55-76 1 ELBOW, 1 1/2" 90-DEGREE STREET BRASS 0730-206-32-00 3 5 UNION, 1/" MODIFIED 05700-001-16-52 1 6 PLUMBING, SOLENOID DRAIN TEMPERING 05700-00-1-95 1 07610-00-07-99-E 1 of 8

PARTS INCLUDED Assembly 05700-00-1-98 ITEM DESCRIPTION PART NUMBER QTY 7 DRAIN WATER TEMPERING BRACKET 05700-00-07-92 1 8 THERMOSTAT 05930-003-13-65 1 9 LOCK NUT, 6-32 HEX 05310-373-03-00 2 10 CONDUIT FITTING, 90-DEGREE, 1/2 05975-011-5-1 1 11 LIQUID TIGHT FITTING (SMALL) 05975-011-9-03 1 91 712 9 1 13 8 11 16 10 15 Miscellaneous Parts ITEM DESCRIPTION PART NUMBER QTY 12 ELBOW, 1 1/2" NPT, FEMALE 0730-206-32-00 1 13 WASH HEATER COVER 05700-00-07-95 1 1 CONDUIT FITTING, 5-DEGREE, 1/2 05975-011-5-23 1 15 LIQUID TIGHT FITTING (LARGE) 05975-011-65-51 1 16 DECAL, DISCONNECT POWER WARNING (NOT SHOWN) 09905-00-08-16 1 17 WIRING PACK (NOT SHOWN) 05700-00-07-97 1 18 CONDUIT, 1/2" PLASTIC, 1 1/2' LONG (NOT SHOWN) 05975-111-6-57 1 19 VARIOUS HARDWARE (NOT SHOWN) VARIES VARIES 12 13 1 15 07610-00-07-99-E 2 of 9

1. Drain the wash tank. 2. Remove the front dress panel from the dishmachine and keep the hardware. Disconnect electrical power at the breaker or disconnect switch and tag-out in accordance with procedures and codes. Turn off the water supply. Pipe Thread Sealant Tape must be applied to all plumbing components! 3. Install elbow 0730-206-32-00 into the wash tank discharge and orient as shown below, depending on the unit. TANK DISCHARGE HH-E FRONT OF UNIT. Install nipple 0730-207-0-00 into the other elbow 0730-206-32-00. 5. Install combined nipple and elbow into the elbow installed in Step 3 and orient as shown below, depending on the unit. See note below on nipple placement. HH-E Nipple between Elbows Nipple outside Elbows 07610-00-07-99-E 3 of 9

Pipe thread sealant tape must be applied to all plumbing components upon installation. 6. Install connector 0710-00-3-65 onto combined nipple and elbow installed in Step. Make sure the connector is parallel with bottom of wash tank. HH-E 7. Install union 05700-001-16-52 into reducer 0730-002-55-76. 8. Install combined union and reducer into connector installed in Step 6, in the opening facing the front of unit. HH-E FRONT OF UNIT 9. Install the solenoid assembly 05700-00-1-95 to middle opening (facing the left of unit) of the connector installed in Step 6. The solenoid coil can be removed before attaching assembly to the connector, if necessary. If removed, reinstall after assembly is in place. LEFT OF UNIT 07610-00-07-99-E of 9

Pipe thread sealant tape must be applied to all plumbing components upon installation. 10. Connect the drain discharge piping (not supplied) to remaining opening (facing back of unit) of connector 0710-00-3-65. An extra elbow 0730-206-32-00 has been supplied to make the connection, if needed. HH-E BACK OF UNIT 11. Connect cold water supply to the solenoid valve. A nipple 0730-207-02-00 has been supplied to make the connection, if needed. 12. Remove the wash tank heater cover. Use a 3/8" nutdriver or wrench to remove the two nuts from the cover (located at top and bottom of the cover). Keep hardware! 13. Remove the two right-side nuts and lockwashers from the wash tank heater using a 1/2" socket or wrench. Keep hardware! 07610-00-07-99-E 5 of 9

1. Place 05700-00-1-98 over studs and reinstall the two nuts and lockwashers removed in Step 13. 15. Remove nut from union 05700-001-16-52 and slide it onto thermostat probe. Insert probe into union 05700-001-16-52 and tighten nut back down. 16. Place the thermostat capillary tube alongside the bracket.! CAUTION CAUTION! The capillary tube must be placed in a way that prevents damage to the tube. 07610-00-07-99-E 6 of 9

! WARNING 17. Using a phillips screwdriver, remove the four screws (two on each side) securing the control box cover. Ensure the power is off! Keep hardware! 18. On the back of the control box, remove the lower black plug and replace it with 05975-011-65-51. 19. Insert the SJ cord through 05975-011-65-51. The end with the pink terminals goes into the control box. 20. Attach pink terminals to the input side of the motor contactor. The white wire from the SJ cord connects to terminal below the red wire. The black wire from the SJ cord connects to terminal below the black wire. Both are located on the motor contactor. For 60 V machines, skip this step and go to Step 21. 07610-00-07-99-E 7 of 9

21. FOR 60 V MACHINES ONLY: Locate constant voltage connection and pull terminals T1-A (gray wire) and T1-B (red wire) from fuse holders. Place one piggyback terminal on T1-A and one on T1-B and reconnect them to the constant voltage connection fuse holders. Connect black wire from the SJ cord to the T1-A piggyback terminal. Connect white wire from the SJ cord to the T1-B piggyback terminal. 60 V machines only! 22. Route the SJ cord through the existing bracket on back of machine. Tie-wraps are supplied to secure the SJ cord to existing conduit, if needed. 23. Connect the conduit from the coil to 05975-011-5-1 attached to the bracket. Both the red and white wires from the conduit must come through the fitting. 2. Connect the white wire from the coil to the white wire from the SJ cord using the supplied wire nut. Connect the red wire from the coil to the normally-open terminal on the thermostat. 07610-00-07-99-E 8 of 9

25. Connect the black wire from the SJ cord to the common terminal on the thermostat. 26. Adjust thermostat to needed setting. Adjust thermostat by turning clockwise to react to higher drain-water temperatures or counterclockwise to react to lower drain-water temperatures. 27. Install 05700-00-07-95 using hardware removed in Step 12. 28. Replace the front dress panel and control box cover using hardware from earlier in the procedure. 29. Restore power and water to the machine. 30. Run the machine through five cycles to ensure there are no leaks. If there are any issues after installation, please contact Technical Service at 888-800-5672. 07610-00-07-99-E 9 of 9