TABLE OF CONTENTS. 1. Technical specifications of the appliance 2

Similar documents
COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS OPERATING INSTRUCTIONS

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS

0LLCD003EN STANDBY NORMAL INFO MENU INFO DATA SETUP MENU PARAMETER VALUE. Not Product Air Display scale Operating Temper. (sim.

New LAE controller for Plug-in cabinets

BSD SERIES REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

PRO A CABINET & COUNTER

Service Manual. LC125 Meatwell with LDU15 Controller (Feb 04 till July 09) then AT1-5 Controller (July 09 onwards)

Service Manual. Slimline Range With LF28 Controller ISO ISO 9001

Environmental Management Policy for Service Manuals and Duets.

TRUE TEMPERATURE CONTROLS SEQUENCE OF OPERATION

Installation & Operations Manual. Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800) REV: LN PN

Maintenance Manual VCS

Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800)

Original Service Manual

Service Manual. EPrem Cabinets & Counters with FD2-10 Controller ISO ISO 9001

Original Service Manual

Service Manual. Slimline Range with FD2-10 Controller ISO ISO 9001

BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers

FlexDrawer. Original Service Manual. FFC6-2, 3-1, 4-2 & 2-1 Models. FD2-10 Controller & LCD5S Display. English

ER52 - Evaporator Controller

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Cabinet Refrigerators/Freezers Instruction manual

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Multideck Display Cabinets

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS for HOAM and VOAM Open Air Merchandisers

USING THE REFRIGERATOR COMPARTMENT

SERVICE MANUAL REFRIGERATION

PC87 American Style Double Door Fridge Freezer Manual for Installation, Use and Maintenance

Stainless Steel Counter Refrigerators Instruction manual

3/15 Rev B

KELVINATOR C O M M E R C I A L COMMERCIAL FREEZER/REFRIGERATOR REACH-IN REFRIGERATOR AND FREEZER. Refrigerator Model: KCBM23R, KCBM48R, KCBM72R

Chest Freezer Instruction manual

ER MANUAL FOR YOUR BAUMATIC

COMMERCIAL REFRIGERATOR & FREEZER SERVICE MANUAL (SCL/SCLM)

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

PC52 American Style Fridge Freezer

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

BLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance.

User Guide ems25plus. Page 1. Normal operation. Product interface

OPERATING AND INSTRUCTIONS MANUAL: B130/10/220H VACCINE REFRIGERATOR REV.1 (WITH TEMPERATURE HOLDOVER FUNCTION)

THERMOELECTIRC WINE COOLER

FWC860 Wine Cooler Installation, Use and Maintenance

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

USER MANUAL. Laboratory Refrigerator Range. Applicable models: LSR151 LSR288

GS-1. Instruction Manual. G-Series Cooler. Manual is for the following models: GS-1-N14NF GS-1-N14NG GS-1-N14NI COUNTERTOP COOLER

USER MANUAL. Pharmacy Refrigerator Range. Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151

SWIMMING POOL HEAT PUMP Owners Manual

REMOTE CONTROL FOR CHILLER MYCHILLER

Built-under larder fridge instruction manual RBL4. Contact Caple on or for spare parts

TCW 2000 Ice liner refrigerator and freezer PIJ

USER GUIDE. TL6015W TL6018W 60cm Larder

Chest Freezer HSA46330

EVAKOOL ELITE - UPRIGHT FRIDGE FREEZERS OPERATING MANUAL

CHEST FREEZER HS225523

CAREL IR33+ CONTROLLER

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

GS-2. Instruction Manual. G-Series Cooler

INSTRUCTIONS OPERATING BLUETOOTH CAPACITIVE TOUCH THERMOSTAT MODEL COOL/FURNACE COOL/FURNACE/HEAT PUMP

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 15 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 17

SPR7-OS SPR601-OS SCR600L-OS SPR601-OSRC SCR600L-OSRC SP6DSSTB-OS

RCB53724MW RCB53724MX RCB53724VW RCB53724VX. User Manual Fridge Freezer USER MANUAL

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

KitchenAid Food Stream Solutions Classic and Integrated Series

CONTENTS. 1. Safety recommendations 2 Table of warning and attention plates 3. Description of the unit 4. Operation 5. Handling

User Manual. Dishwasher ZDM17301SA ZDM17301WA

FW422 Integrated In Column Larder Fridge Manual for Installation, Use and Maintenance

THERMOELECTRIC COMBO COOLER. Model: DX-68 COMBO. Operation Manual

FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance

FWC153, FWC304, FWC604 & FWC624

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

10/2017. Mod: WR-FP600-X. Production code: AGBS-600RI /

USER MANUAL. Platinum Refrigerator & Freezer Range

MFC501 & MFC701. Manual for installation, use and maintenance. Integrated fridge-freezers. year.

HOW TO USE THE FREEZER COMPARTMENT PAGE 16

PRODUCT DESCRIPTION CONTROLS

REFRIGERATED CASES VITRINAS REFRIGERADAS

Installation & Operations Manual for. BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers. 6/17 Rev.

SERVICE MANUAL REFRIGERATION

PC71 American Style Fridge Freezer

Installation & Operations Manual. Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800) /17 Rev.

Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800)

BUILT-IN OVEN MODEL: EBO-D7080D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

REFRIGERAT A OR USE DF1-15 F ridge

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

BUILT-IN OVEN MODEL: EBO-E7081D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 17 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 19

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers

INSTALLATION and OPERATION INSTRUCTIONS

FW851 / FW871 Integrated Fridge Freezer Manual for Installation, Use and Maintenance

Model:WHS-109FB1/WHS-109FW1/WHS-109FSS1

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

Operation manual. Rooftop Packaged Unit

FF820 Freestanding Full Height Larder Fridge Manual for Installation, Use and Maintenance

Table 1. Serie of Digital Room Thermostats.

Transcription:

TABLE OF CONTENTS Pages 1. Technical specifications of the appliance 2 a. Refrigerated counter 2 b. Upright refrigerator 3 c. Open top refrigerated counter 3 d. Pizza refrigerated counter 4 e. Pizza refrigerated show case 4 2. Transportation Positioning Installation 5 3. Safety instructions 6 4. Instructions for use of thermostat BIT12RU 6 5. Instructions for use of thermostat SMD12 8 6. Instructions for use of thermostat MTR11 9 7. Instructions of new thermostat for drainage resistance 10 8. Daily and general cleaning Maintenance 10 9. Temporary interruption of functioning 10 10. Advice for saving energy 10 11. Troubleshooting 11 12. Electric diagrams 12

READ CAREFULLY THE FOLLOWING INSTRUCTIONS BEFORE USE. 1. Technical specifications of the appliance a) Refrigerated counter The refrigerating equipment is incorporated in the lateral part of the appliance. Technical data are shown at the following table: BP7300 PN99 PN999 PN9999 Capacity (Lt) 266 352 433 588 *Temperature (ºC) 0ºC ~ 10ºC 0ºC ~ 10ºC 0ºC ~ 10ºC 0ºC ~ 10ºC El. Consumption (KWh/24 h) 5,12 5,12 5,12 6,81 Weight (Kg) 100 122 130 154 Freon R134a R134a R134a R134a Cooling power (W) 773 773 773 1022 Compressor power (HP) 1/4 1/4 1/4 3/8 Dimensions out (cm) 106,5 x 70 x 86 156 x 70 x 86 179 x 70 x 86 224 x 70 x 86 Dimensions in (cm) 95,5 x 58 x 48 101 x 58 x 60 124,5 x 58 x 60 169 x 58 x 60 Dimensions packed (cm) 108 x 75,5 x 99 157 x 75,5 x 91 180 x 75,5 x 91 225 x 75,5 x 91 Number of shelves 2 2 3 4 Dimensions of shelves (mm) 325 x 555 325 x 555 325 x 555 325 x 555 * Temperature is controlled by electric thermostat. 2

b) Upright refrigerator Refrigerated cabinet The refrigerating equipment is incorporated in the upper part of the appliance. Technical data are shown at the following table: CA170 CB170 CE2140 CF2140 Capacity (Lt) 679 679 1471 1471 *Temperature (ºC) 0ºC ~ 10ºC -20ºC ~ 0ºC 0ºC ~ 10ºC -20ºC ~ 0ºC El. Consumption (KWh/24 h) 6,81 7,46 8,83 9,81 Weight (Kg) 114 115 175 175 Freon R134a R404a R134a R404a Cooling power (W) 1022 798 1560 1140 Compressor power (HP) 3/8 3/4 1/2 1 Dimensions out (cm) 85 x 70 x 208 85 x 70 x 208 85 x 140 x 208 85 x 140 x 208 Dimensions in (cm) 73 x 60 x 155 73 x 60 x 155 73 x 130 x 155 73 x 130 x 155 Dimensions packed (cm) 86,5 x 72,5 x 86,5 x 72,5 x 86,5 x 142,5 x 86,5 x 142,5 x 218 218 218 218 Number of shelves 3 3 6 6 Dimensions of shelves (mm) 534 x 690 534 x 690 534 x 690 534 x 690 c) Open top refrigerated counter The appliance is based on the simple refrigerated counter construction and it can be produced with a luminous glass case. It is an open top construction allowung the option to place two rows of gastronorm pans. BS7300 ZQ99 ZQ999 Capacity (Lt) 266 352 433 *Temperature (ºC) +2ºC ~ 10ºC +2ºC ~ 10ºC +2ºC ~ 10ºC El. Consumption (KWh/24 h) 5,34 7,03 7,03 Weight (Kg) 130 151 166 Freon R134a R134a R134a Cooling power (W) 773 1022 1022 Compressor power (HP) 1/4 3/8 3/8 Dimensions out (cm) 106,5 x 70 x 129 156 x 70 x 129 179 x 70 x 129 Dimensions in (cm) 95,5 x 58 x 48 101 x 58 x 60 124,5 x 58 x 60 Dimensions packed (cm) 108 x 75,5 x 135 157 x 55,5 x 135 180 x 55,5 x 135 Dimensions of shelves (mm) 325 x 555 325 x 555 325 x 555 Number of G/N pans 12 12 14 3

d) Pizza refrigerated counter The refrigerating equipment for pizzas is incorporated in the lateral part of the appliance. The appliance is provided with a white marble from the island Naxos 1 for its counter top. WN88 WN888 Capacity (Lt) 507 690 *Temperature (ºC) +0ºC ~ 10ºC +0ºC ~ 10ºC El. Consumption (KWh/24 h) 6,81 6,81 Weight (Kg) 116 140 Freon R134a R134a Cooling power (W) 1022 1022 Compressor power (HP) 3/8 3/8 Dimensions outside with top (cm) 179 x 80 x 86 224 x 80 x 86 Dimensions inside (cm) 124,5 x 68 x 60 169 x 68 x 60 Dimensions packed (cm) 180 x 85,5 x 91 225 x 85,5 x 91 e) Pizza refrigerated show case The pizza refrigerated show case is an open top construction providing for the use of one row of gastronorm pans. It can be produced with a luminous glass case. WV179 WV224 Number of G/N pans 1/4 8 11 *Temperature (ºC) +3ºC ~ 10ºC +3ºC ~ 10ºC El. Consumption (KWh/24 h) 1,72 1,72 Weight (Kg) 50 60 Freon R134a R134a Cooling power (W) 122 139 Compressor power (HP) 1/6 1/5 Dimensions outside (cm) 179 x 34 x 42 224 x 34 x 42 Dimensions packed (cm) 184,5 x 39 x 47 229,5 x 39 x 47 All models voltage is 230 V / 50 Hz. Insulation thickness is 50 mm. Temperature is controlled by electric thermostat. 1 The island of Naxos in the Aegean archipelago is famous from the ancient years for its crystalline marble production. 4

All the technical characteristics necessary are specified on the identification tag positioned to the right of the device. 2. Transportation Positioning Installation! ATTENTION: Keep the appliance in an upright position during the transportation in order to avoid critical damage in the appliance s systems. Remove all packaging. Move carefully the device to its final position. If the floor is not flat regulate the feet, so that all the feet are in contact to the floor. Keep the appliance slightly bent backwards for better door closing. Insert the plug into the current tap and the installation is completed. The appliance is supplied with an electric plug, SHUKO type.! ATTENTION: Current taps or plugs always must be provided with ground (SHUKO type). If the device has showcase remove the packaging among the crystals and move the two side crystals unscrewing the screws pointed at the picture, so that the crystals line-up with the front crystal of the vitrine. 5

3. Safety instructions For your safety and the proper function of the appliance please follow the instructions below: SAFETY INSTRUCTIONS Store all products to be preserved so as not to obstruct the air circulation among the shelves of the appliance. Do not store hot food or hot drinks into the refrigerator. OXI Do not install the appliance near heat sources or inside rooms with high temperature (over 40 0C) and humidity. This would cause a low efficiency and short life. Never let the doors open for a long time. Do not cover the intake air slots when the machine is ON. On solid door refrigerators especially do not cover the upper side of the appliance. On pizza show cases do not cover the right side of the appliance, where the cooling machine stands. Cover the food with a plastic film before putting it into the refrigerator. Do not change the parameters of the electronic thermostat. This should be performed only by an authorized technician. F Do not wash the appliance by spraying high pressure water. Do not use detergents or substances based on chlorine. These could corrode the surface of the refrigerator. On pizza refrigerated show cases: Do not operate without gastronorm pans covering the whole cooling space. 4. INSTRUCTIONS FOR USE OF THERMOSTAT BIT12RU FOR REFRIGERATORS The user can be informed of the temperature desired by pressing the or button according to the model of the screen settled on the appliance. The user can change this temperature by pressing the arrows to the right of the screen. 6

All configuration parameters are adjustable within the SETUP function which is accessible by pressing [6 ] + [ ] + [ 5 ] for 4 seconds. Scroll the parameter list via keys [ 5 ] and [6 ] until you achieve the desired one, display its value by pressing [ ] and modify it via [ ] + [5 ] or [ 6 ]. Exit from the setup takes place automatically after 15 seconds of no key activation. If probe A fails, the display shows E1 and the compressor remains on for either 40% or 100% of the time. Parameter cf determines the compressor status: 00 = 40% (3 min. on, 4 min. off); 01 = 100% (always on). Defrost The defrost frequency is determined by parameter df and the duration by parameter dt. With df = 0, automatic defrosts are suspended. As the BIT20B model does not include defrost termination probe and defrost relay, parameters dl, dm and dr have got a particular meaning and must not therefore be set to values different from factory settings. Defrost may also be induced manually, by pressing the button located on the control unit or by pressing keys [ 5 ] and [ 6 ] simultaneously. Table 1, Parameters for refrigerators Symb Description Min and Max Limits 1 SP Set point SL Sh 2 SL Minimum set point limit -35 Sh Factory Setting Notes 3 Sh Maximum set point limit SL +15 0 C +08 0 C 4 hy Hysteresis (delay) (+01 +08) Κ +03 Κ 5 cr Compressor minimum pause 00 04 02 min 6 cf Compressor in TA failure 00=40% 00 01=100% 7 df Defrost frequency per 24 hours 00 12 06 times per 24 hours 8 dt Maximum defrost duration 01 90 20 min 9 dl Defrost limit temperature +01.+20 10 0 C Don t change 10 dm Defrost mode 00 = off cycle 01 = electrical 02 = hot gas 01 Don t change 11 dr Drain time 00..10 00 Don t change 12 th Temperature hidden in defrost 0=on 60 5 min 13 to Display offset (-09...+09) Κ 14 ts Display slowdown 00 20 00 Notes: All refrigerated counters work between 0 0 C and 3 0 C, except the open top refrigerators, that work between 2 0 C and 5 0 C. If you want your refrigerator to work between -2 0 C and +4 0 C, then you should change the following parameters: a) Change the parameter 1 (SP) to (SP)-2 (if (SP)=2 then you must set (SP)=0) b) Set the parameter 4 (hy) = 6. 7

5. INSTRUCTIONS FOR USE OF THERMOSTAT SMD12RU FOR FREEZERS Your new appliance has on its front a little digital screen where the user could read the temperature inside the refrigerator. 5.1. SETTING TEMPERATURE: The user can be informed of the setpoint temperature by pressing. He can change this temperature by pressing the arrows to the right of the screen. 5.2 DEFROST: The defrost frequency is set 4 times per day. It is possible to manually start or abort defrost by pushing key [i ] and then [i ] + [5]. 5.3 SETUP MENU: To access the parameter menu select 47 for the passcode PC. To achieve this press buttons [ i ] + [5]. You exit from setup by pressing [i ] or automatically after 30 seconds of no button activation.! ATTENTION: The thermostat s parameters are set by the factory in order to accomplish best performance of your device. Before any change in the setup menu you should be advised by an authorized technician. Table 1, Parameters for freezers Symb Description Minimun and Maximum limits 8 Factory settings 1 SPL Minimum set point -40 +SPH 0-21 2 SPH Maximum set point SPL +250 0 0 3 SP Temperature set point SPL.....SPH 0-18 4 hys Hysteresis (delay) -30 +30 0 3 5 DFR Defrost frequency / 24h 00 24 4 6 DLI Defrost end temperature 00 70 0 30 7 DTO Defrost time out 00 120 min 20 8 DTY Defrost type OFF / ELE / GAS ELE 9 DRN Dripping time 00 30 min 0 10 DDY Display in Defrost 00...60 min 10 11 FPC Evaporator fan control 0... 5 0 12 FDD Fan restart after defrost -40... +70 0-2 13 ATL Low alarm differential -25... 0 0-25 14 ATH High alarm differential 0... +25 0 0 15 ATD Temperature alarm delay 0 120 min 60 16 ADO Door alarm delay 0 120 min 5 17 ACC Periodic condenser cleaning 0 120 weeks 26 18 ACT Condenser alarm temperature 0 250 0 70 19 CSD Compressor safety stop delay 0 30 min 0 20 CFT Condenser temperature -40... +250 0 25 21 CRT Compressor rest time 0 30 min 2 22 CDC Cooler duty cycle 0 10 min 10 23 OFF Standby button enable YES/NO YES 24 DS Door switch enable YES/NO YES 25 LDO Lights enable YES/NO NO

26 T2 Probe 2 enable YES/NO YES 27 T3 Probe 3 enable YES/NO ΝΟ 28 SCL Temperature units selection 0 C / 0 F 0 C 29 os1 Thermostat offset -15 +15 0 C 0 30 os2 Evaporator offset -15 +15 0 C 0 31 os3 Display offset -15 +15 0 C 0 32 SiM Display delay 0 100 0 33 Adr Peripheral number 000 255 01 Note: If you wish a freezer to work as a refrigerator then you must change the following parameters: 1) Change the parameter SPL (1) from 21 0 C to -2 0 C 2) Change the parameter SPh (2) to 10 0 C 3) Change the parameter SP (3) to 0 0 C 4) Change the parameter FDD (12) to +8 0 C 5) Change the parameter ATL (13) to -2 0 C 6) Change the parameter ATH (14) to +10 0 C 6. INSTRUCTIONS FOR USE OF THERMOSTAT MTR12 FOR PIZZA SHOW CASE 7.1. The user can be informed of the desired temperature by pressing the button. He can change this temperature by pressing the arrows to the right of the screen. 7.2 Pressing the key [ set ] the programed minimum temperature value is displayed for 2 sec. 7.3 Pressing the key [ hys ] the delay value is displayed for 2 sec. 7.4 SETUP: Switch off the unit; press keys [ 5 ] and [ 6 ] and, by keeping them pressed switch on the unit again; Par appears on display. Parameter selection and the display of the value is obtained by pressing key [ set ] repeatedly; change with keys [5] and [6] and store with [ set ]. To skip from one parameter to the next without displaying the value, press key [ 6 ]. It is also possible to select a specific parameter and change its value by following the diagram attached. Table 1, parameters for vitrine pizzas A/a Symb Description Minimum and Maximum limits 9 Factory Settings 1 6SP Minimum set point limit -50 +150 0 C +03 0 C 2 5SP Maximum set point limit 6SP +150 0 C +07 0 C 3 rt1 Minimum Off time for RL1. 00 10 minutes 01 min. 4 PF1 Permanent status assigned to RL1 On Off On output in case of probe failure 5 ADJ Offset added to the input value -20 +20 K 6 hy1 Hysteresis (delay) -25 +25 K 03 K

7. Instructions of new thermostat for drainage resistance Your new appliance has a 150 W electric resistance in order to evaporate the condensed water in the drainage canister. The function of the resistance is controlled by a thermostat, situated next to the cooling mechanism, at the top of the refrigerator. The thermostat accomplishes best performance and minimum consumption of the resistance. The optimum setting for the thermostat is 65 C for refrigerated cabinets and 75 C for freezers. At environments, where humidity is higher than 70% increase the above setting to 70 C and 80 C accordingly. The electric consumption of the resistance with the above settings is 0,4 KW/24h for refrigerated cabinets and 2,1KW for freezers. 8. Daily and general cleaning Maintenance Frequent cleaning is highly recommended. Do not use sharp or other similar objects which may damage your appliance. Empty the drain basin (if there is one) in the lower part of the refrigerator regularly. Clean the surfaces with a wet cloth carefully. In case of spots or food rests wash with hot water before they get to hard to be washed out. Use water and neutral soap or a detergent without chlorine and eventually some wooden spatula or a thin stainless steel sponge. Also clean the space around and under the appliance. The usual unpleasant smell disappears if some vinegar is added to the cleaning water.! ATTENTION: Do not wash the appliance by spraying high pressure water. Do not use detergents or substances based on chlorine or acid solvents. These may cause corrosion of stainless steel. Keep the condenser of the refrigerator clean, according to the conditions and the place where the appliance operates. Otherwise, the efficiency of the refrigerator will be reduced and finally the compressor will fail. Before you proceed to any cleaning or maintenance, put off the general switch and disconnect the plug from the electrical supply. 9. Temporary interruption of functioning In case you wish to put the appliance off for a while, in order to keep it in the best possible condition, follow the instructions: Put the appliance off and disconnect from the electrical supply. Empty the appliance and clean it as indicated above. Keep the doors open in order to avoid unpleasant odors. 10. Advice for saving energy Open the appliance s doors according to your needs but do not do that pointlessly. They must remain open the less possible can be, especially during hot and humid periods. The utensils you put in the refrigerator must be dry and the food must be wrapped with special film in order to limit the humidity inside the refrigerator. Check regularly that the refrigerator s doors are solidly closed. Check the door seals inside the doors. Do not place your refrigerators near heat sources as radiators, ovens or points with high sun radiation. 10

Do not fill at once your appliance with big quantities of products, because this will increase the energy consumption. 11. Troubleshooting Malfunction Possible cause Solution 1 The refrigerator does not There is ice in the See case 2 cool evaporator The products are obstructing the air flow Remove the products which obstruct the air flow of the evaporator Ice in the cooling system Call a technician to change the filter The room temperature is very high Improve the temperature condition of the room 2 Ice in the evaporator The temperature adjustment is very low (for high temp. refrigerators) Check the temperature adjustment. Increase the parameter SP to 1 or 2 ºC Defrost malfunction Proceed to a manual defrost. If the defrost function works increase the defrost frequency. If the defrost function fails, change the thermostat. High humidity environment Improve the environment condition. Humid products have been placed in the refrigerator (ex. Vegetables) The doors are opened frequently and for a long time 3 Water in the refrigerator The drainage pipe has been sealed Bad sealing of evaporator base 4 The drainage pipe has ice Evaporator resistance (for freezers) failure The drainage pipe has been sealed 5 Water in the gastronorm High humidity environment pans (for open top refr.) 6 The fuse burns when Evaporator resistance defrost takes place failure (for freezers) The fuse is smaller than the proper 7 The thermostat display The door switch has been indicates Alarm and the disconnected compressor does not Door switch failure function (for freezers) Evaporator fan failure Increase the defrost duration. Cover the food with a plastic film before putting it into the refrigerator. Increase the defrost duration. Decrease the open door duration as possible. Increase the defrost duration. Clean the drainage pipe Repair by a technician Replace Clean the drainage pipe Decrease the cooling temperature Replace See the minimum fuse (A) on the identification tag Reconnect the door switch to the thermostat display Replace Check if the evaporator fan works. If not replace. Ł In any case of malfunction contact the dealer of our company describing the problem, denoting the type and the serial number (S/N) of your appliance. 11

COMPRESSOR No 1 CONDENSER FUN PROBE N1 L1 CONTROL BOX 230 N 3 4 (GROUND) L No 2 1 2 1 2 3 4 ON/OFF SWITCH EVAPORATOR FUN ELECTRIC DIAGRAM FOR POSITIVE REFRIGERATORS BIT12RU Date 31/1/02 Rev. 0 Scale (1:1) 12

13

CONDENSER FUN COMPRESSOR N L L N G DOOR SWITCH DOOR DRAIN RESISTANCE RESISTANCE 230 EVAPORATOR RESISTANCE 12V 230V EV 3 4 G N L1 CONTROL ΒΟΧ L11 N LIVE N N L5 1 2 3 1 1 2 4 2 ON/OFF SWITCH PROBES TH EVAPORATOR FUN DISPLAY DRAINAGE RESISTANCE ELECTRIC DIAGRAM FOR FREEZERS SMD12 Date Rev. Scale 1/3/2002 1 14

ON/OFF SWITCH 230 COMPRESSOR CONDENSER FUN PROBE 11 5 4 3 2 1 THERMOSTAT MTR12 ELECTRIC DIAGRAM FOR WV179 & WV224 Ημερομηνία 1/1/2003 MTR12 1 Αναθ. Κλίμακα 1:1 15