HOME SECURITY MICROPROCESSOR CENTRAL UNIT HOME 5 USER S MANUAL

Similar documents
HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Watchguard WGAP864 User Manual

CA60Plus. Installation manual

Solution 844 Operators Manual ISSUE 1.10

TABLE OF CONTENTS TABLE OF CONTENTS 1

Sentry 4 Zone Alarm Panel User Manual

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

AXI LED USER MANUAL (REV. 1.0)

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

PROGRAMMING PROCEDURES (Table 3)

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Solution Ultima 862 Operators Manual ISSUE 1.10

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Wireless Keypads LKP(E)S8M Series

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Intruder alarm panel Terxon MX Operating instructions

IDS816 User Manual H Issued January 2009

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

5000 SERIES 8 ZONE INSTRUCTION MANUAL

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

Model: M30. Owner s Operation Manual. For correct operation, please read this manual to familiarise yourself with the features.

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

BURGLAR ALARM PANEL BS-468

EasyLoader. End User Manual

Condominium Security Management System

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

/24 USER MANUAL

Total Protection Alarm System

LS800S Intruder Alarm System. Engineering Manual

Contents. Glossary

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

"Pegaso" wireless alarm system D.I.Y. wireless kit


/ /24 INSTALLATION AND USE MANUAL. Made in Italy AC 2710/UK Rev /12

INSTALLATION MANUAL PC56O. Version 1.OA

Wireless Keypad GKP-S8M

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

EVO192 v3.0 Fire and Burglary What s New

SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual

JA-63 PROFI Alarm System MGK55402

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

ITI Caretaker Basic Commands

HSA % wirefree security alarm system. Installation Programming Operating. Helpline Intelligent Security & Fire Ltd

Solution 880 Operators Manual. Issue 1.00

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

PERMACONN PM1030 Includes DI300. Installation Manual

Version 1.03 January-2002 USER S MANUAL

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

G34 AU1B (External Ultrasonic Sensor) Version 3

1. Introduction. 2. Product overview

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

CPVan Home Alarm Starter Kit

VAP304 PRO INSTALLATION & OPERATION MANUAL

Auto Dialer. Manual E-921APQ E-921GPQ

Solution Ultima Series Operators Manual ISSUE 1.00

Paradox Security System Graphic Dept - PRINTED IN CANADA. keypad entries in memory. arming permits movement in pre-selected,

PRO-TEC SYSTEM ONE. Trailer Security Systems Model # PTS-2. Photo includes PTS-2 with optional pager unit

Supervised Security System Owner's Guide

SR-i500 INSTALLATION MANUAL AND USER S GUIDE. FM 2-Way Security System. Setting Clock Time. Setting Alarm Clock. FCC Notice

AMX 68 Owner's Manual 12/29/97

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

TRUST WIRELESS ALARM SYSTEM 200S

"Pegaso" wireless alarm system

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

INSTALLATION MANUAL DV8OOO. Software Version 1.0

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

3 User s settings. 3.3 Internal clock setting

AL600ULADA. NAC Power Extender. Installation Guide

INSTALLATION MANUAL PC15OO

User Manual. with LED Keypad. Alarm Control Panel CA10 plus (software version 4.7) GDAŃSK. ca10pldu_e 07/03

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

X64 Wireless Training

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Installation & Programming Guide

WARNING FIRE DOOR CLOSING

JA-63 Profi User manual

USER GUIDE. PowerMaster-10 G2 Fully supervised wireless alarm control system.

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

TO ARM/DISARM ALARM The alarm is activated by pressing BUTTON 1 on the remote control transmitter once. The blinkers will flash once, and the

Summit 3208GLD USER MANUAL. Electronics Line

AP10LED 10 Zone onboard LED Alarm Panel. Engineering Manual

For silent arm / disarm use BUTTON 2.

User Manual. Alarm system: PhoneWatch TC

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

INSTRUCTION MANUAL FOR. Remote Control Car Alarm with Impact Sensor, Mini-Battery Backup Siren & Engine Immobiliser

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

Transcription:

HOME SECURITY MICROPROCESSOR CENTRAL UNIT HOME 5 FEATURES USER S MANUAL - remote control by two buttons; - (dynamic code up to 6 remote transmitters) - 4 zones, double balanced circuits; - indications for: * power supply of the central unit * statu s (OFF/ON) * status of each zone (active / passive) * alarm memory for each zone * memory for the last 8 alarms - three security modes, two setup modes; - function bell for each zone (by choice) - double supply (220 VAC network and acid battery) with automatic charge - built-in magnetodinamic siren 126dB - built-in tamper-buttons against sabotage - possibility for wiring all kind of security sensors (12V normal closed switches for alarm and tamper) - outputs for: - status outstanding indication (ON/OFF) 100mA - additional siren or dialer, current 2A to the ground - low power acid battery 100mA to the ground - chirp tone if switched ON/OFF, four levels of sound intensity USER S INSTRUCTION 1. Remote control: Remote transmitter has two buttons:

Left (I) switches ON the central unit Right (II) switches it OFF 2. Indications At the bottom part of the box: 220V (green) shows existing of power supply, when it is switched off it means the system works with acid battery supply and it is necessary to take care for restoring it. The battery can secure proper work of the system during couple of hours to three days, due to its capacity and number of mounted sensors. After battery s discharge the system becomes uncontrolled. Armed (yellow) - shows system s status If LED is ON it means the system is armed in some arm modes, if LED is OFF the system is in Disarm mode. Zone 1 Zone 4 (red), show each zone status. If the LED doesn t light on, it means that all detectors, connected to corresponding zone are in neutral status, if some of the LEDs lights on it means some of detectors from this zone are been triggered. If the system is disarmed, any blink LED shows, which zone is been triggered. The same LED shows the current status of the zone if some detector is triggered, the LED lights on and off, shortly twice in second, but in neutral mode of the zone the LED lights off and blinks shortly twice in second. 3.Arm modes. There are four security modes of the central unit: - disarmed - armed - armed in Special mode 1 - armed in Special mode 2 Each mode can be set by the remote transmitter. 3.1. Disarmed: Before coming into the security zone, press the right button to disarm. Double chirp is heard and lighting zone Armed lights off. If the remote transmitter for disarming is with random code and its acid battery power is below 10V, after double chirp, double separated sound is heard (the same as in function bell ). Every time the right button is pressed, the system is disarmed (as described above), independent of the system status (ON/OFF). In this mode the central unit disables control of sensors to all system zones, but still keeps to control system and if any cable has been disconnected or zone sensor has been opened or disconnected (sabotage in system), the starts alarm immediately. Tampers for sabotage in the central unit are connected to the fourth zone internally. 3.2 Armed. In this mode the system is turned by pressing left button on the remote transmitter (RT) after leaving and locking the security area. One chirp will be heard and the yellow LED will light on (Armed). 6 seconds after arming, the system disables all detectors, to avoid false alarms from triggered detectors when the area has been left. All 4 LEDs light on, showing that the system will read all zones. After that the LEDs light off and any detector triggering will turn on the alarm immediately. 3.3 Special Arm mode 1. Turn on this mode as follows: When the system is disarmed press the left button, a chirp is heard, within 1 to 6 sec. after press the same button again, long and short

chirp is heard. In this order only the programmed zones for the mode (normally 1 and 4) light on. The difference with the previous mode is that in the present mode work only programmed for the mode zones. 3.4 Special Arm mode 2 This mode is turn on by consequent pressing of the left button three times after the system is disarmed. After the first pressing, a chirp is heard and the system is armed. After the second pressing (within 6sec.) special arm mode 1 is ON and a long and short chirps are heard. With third pressing special arm mode2 is ON and a long and two short chirps are heard. The LEDs flashes corresponded to armed zones (normally zone 1) in this mode. Pressing of the left button in more than 6 sec., calls indication (light and sound) for the system status only. If you are not sure for the present system mode, wait 10sec.and press the left button. 4. To interrupt alarm. If any detector is triggered, the system starts alarm by build-in siren and additional devices for determined time (it is set to 2 or 4 min during initial installation). You could stop alarm by pressing one of the two buttons on RT. According to the pressed button the system stays in arm or disarmed mode. When you are stopping the alarm, if corresponding zone is still triggered, the system is disabling it till the zone is restore. This function is useful in case, for instance - the system is armed after leaving the protected area, but some detector is defective and triggered, as permanent triggered sensor or a door is left opened. Six sec. later the system will alarm in such case. Two possible actions exist - disarm the system and check in the memory which zone is been triggered. The second possibility is to press button enabling the arm mode after alarm, so the alarm stops and the defective zone is disabled, but other zones are controlled as usual. A partitive arming is possible till repairing, and at the same time the trouble can not be passed through. 5. Check the last alarms. If you press and hold the right button more, than 4sec, the system comes in Last Alarms check mode. In this mode the system chirps by a long and short tone, the zone s LED indicates which zone is been triggered. Any next pressing on right button shows previous triggering, a long chirp is heard. To quite this mode press the left button - or automatically after 30sec. 6. Programming. To put the system in this mode you have to press left and right button simultaneously for more than 4sec. Thus you can program zones in Special modes, the loudness of chirp or time for alarm, or zone with bell function. The programming is described in Installation manual. To quit press and hold both buttons for 4sec. - or automatically after 30sec. Note: Don t use this mode if you are not familiar with Installation manual. 7. Panic mode If hold the left button for more than 4sec. alarm is activated. Stop the alarm as it is described in Chapter4. 8. Bell. This function is set in programmable mode. For the selected zones usually zone of the entrance door in every opening if the central unit is disarmed, a short chirp is

heard to warn that somebody enters. Ordinary used in offices and shops if current view to the door is missing. By learning the function is switched on to first zone and if it disturbs you it has to be switched off from the programmable mode. 9. Battery change If the transmission range of the remote control is extremely low or if, in system type with random code, double chirp is heard (as in bell mode) it s necessary the battery of the transmitter to be changed. HOME SECURITY MICROPROCESSOR CENTRAL UNIT HOME 5 INSTALATION GUIDE INSTALATION Installation of the system has to be done in the following order: - mounting the box of the central unit by three dubels to the wall, using earmarked holes at the back side of the box: - mount all the detectors on the places fixed in advance - wire all the cables from detectors to the central unit providing a cable for permanent network supply to the electrical board. CONNECTING To every zone you can connect unspecified quantity of standard security detectors (normal closed alarm and tamper switches, with power supply 12V or without

supply, for example magnetic switches, etc.). The requirement to detectors is to provide min 0.5 sec. open switches when they are triggered. For their quantity there are two requirements; 1. Common consumption of all detectors and additional device supplied from the central uni t to be not more than 500mA 2. Total additional resistance from the cables and closed detectors switches not to exceed 30 Ohm for every zone (have in mind that most detectors have connected in series to their switches protective resistance from 10 to 300 ohm, which usually is described in technical characteristics). To wire the detectors follow fig.2 and fig.3. In wiring consider that every zone includes alarm and tamper switches of the sensors, connected to it. The priority of double blanched circuits is that up to 6 detector in zone wiring is through 4 wires cable. Another priority is that there are not separate zones for tamper switches, but all zones are totally used. The principle of the zone with double balanced circuit is following: when the sensors are inactive resistor s value is 1k, if any sensor is activated the resistor s value is between 2-7K, in tamper (line defect or open sensor lid) the resistor s value is less than 500 ohm or over 10K. The rule for wiring of a zone with double balanced circuits with up to 6 sensors is following: start from the Common end (COM) to the last detectorand connect with resistor 1k, in reverse order to the first detector follow consequently all tamper and alarm circuits, as paralle to every sensor alarm switch connect resistor 1K and close the circuit in connectors Z (1-4), (see fig2). When detectors have no tamper, wiring is in the same order but circuit of the tamper switches is contacted in short (shortened). If only one detector is connected in a zone (for example magneticswitched) wiring follows the same rules ( according fig.3) and it s advisable both resistors to be connected at the detector. Zones that aren t in use have to be connected with resistor 1k in the central unit (from Zn to COM ). Except detectors to the central unit can be wired standard additional notification systems. For that pupose following outputs exist: - PG2 output with open collector and active zero (12V/100mA), indicating the status of the central unit (ON/OFF). In armed mode transistor is open (fig. 4). It s used to switch on an additional diode indicating status of the central unit (with relevant terminating by current resistor usually 1K to +12V from detectors or for connecting to alarm transmitters, needing input for central unit status; - CTR output with active zero (2A in a zero) for controlling additional sirens or telephone dialers; - PG3 output with open collector and active zero (100mA), as the power of the acid battery is below 10V(+/-0.5V). It can be used for optional starting of dialer, before the accumulator is fully discharged. Supply of the system is through electric net (220V/ 25W max), connected to the initial coin of transformer and the secondary one to the connectors AC; and though lead (unsupported) acid battery 12V-4Ah, wired to

the blue and red cables by connectors (do not change order of the battery connectors). Calculating value of necessary capacity (in the mentioned range) is dependent of whole system consumption and necessary time of autonomous working, having in mind that consumption of the central unit in inactive mode is about 25 ma. Low current power supply fuse is switched on to electric board, and is almost impossible not to mention its burning (for example the lights). PROGRAMMING You could program the next functions: The switched on zones in both special arm models, the chirp sound loudness, the time during the siren sounds and zones with function bell. To put the system in programming mode you have to press both #1 and #2 simultaneously and hold them at least 4 seconds, the system sounds by 5 short chirps. The programming is separated in 4 options : included zones in first second special mode, included zones in second arming mode, the third option: signalization modes and the fourth option : zones with function bell. By number of chirps indicates which mode the system is put in: first option one chirp pause, second two chirps and a pause and the third three chirps. The change of options is performed by pressing button 1, a long chirp is heard, after that you go to next mode. When you are in some option, the LED`s indicates the option status as follows: - for option 1 and 2 the LED light corresponding to the zone indicates that the zone will be switch ed on in special mode 1(for option 1) or special mode 2 (for option 2).. - for option 3: - Zones 1 and 2 chirp loudness - Zones 1 and 2 don t light on too dark - Zone 1 doesn t light, zone 2 lights on - dark - Zone 1 lights on, zone 2 doesn t light - brightly - Zones 1and 2 light on brightest - Zone 3 duration of siren sound if lights (2min.) otherwise 4 min. - for option 4 lighting of some zone means that the zone will have switched on function bell In order to change some option, when the option is entered just the second button: a long chirp is heard and zone 1 starts blinking. If button1 is pressed, zone 1 stays in light on mode and zone 2 starts blinking: if you press #2 instead #1, zone 1 lights off and zone 2 starts to blink. This is the way to change the four zone of any option, and after fourth zone no LED is blinking, but the zones indicate the new status of the option. After this you could continue to the next option by pressing #1 and by #2 start editting it. The factory standard settings are as follows: - For first mode zone 1 and 4 are turned on. - For second mode zone 1 only - The siren alarms 2 min, the chirp is low - zone 1 has function bell

The sound settings are valid only in normal work of the system. In Programme mode or Mode for alarm memory check, automatically the loudest chirp sound is turned on, in order to make difference between the mentioned modes. If these settings suits, there s no need the system to be reprogrammed. To quit the Programming mode press #1 and #2 simultaneously at least for 4 sec. or automatically after 30 sec. (if no button is pressed during this time). Two long chirps are heard. After you are programmed the system it is useful to verify it. For this purpose turn on consequently both Special Ar ming modes and follow the indication to check if the selected zones are turned on. If the system is with random code transmitters, their learning is done according the following procedure: Connect in short the jumper J2, besides the four LEDs start blinking in consequent order and quickly and the siren produces three chirps. Press once any button of the transmitter and a chirp from the siren is heard. Press second time any button on the RT, a chirp is heard again and if the learning is successful all zones blink quickly in one and the same time. If the learning is unsuccessful, only the first zone blinks. After that disconnect jumper J1 and test the work of the learned RT. The same procedure can be used for learning up to 6 RTs, as the 7 th one erases the setting of the first one. If an old RT is learned its setting are recorded in the same position without erasing the other ones. It s not possible to learned RT six times. To erase all transmitters (RT) turn off the power supply (AC or acid battery), wait the electrodes to be separated (10sec.), connect in short the jumper J1 and switch on the power supply (for instance the battery). The zones blink but slower than in the learning mode. 10-15 sec. after three chirps are heard and the LEDs light off all the transmitters settings are erased. The new RTs are learned following the above described method. INITIAL START UP OF THE SYSTEM The initial start up is done in the following order: 1. After all the cables are connected, switch on the battery, in this case the system will alarm due to open tamper switch of system, connected internally to zone 4. The alarm is stopped by pressing button 2 on RT. 2. After that you have to turn on the AC power supply, the green LED will flash. If the indication for power supply is missing check the connector from the transformer to the main board. 3. Check the sensors status (after passing of their setup time - 1min approx.). If they don t work properly, check the fuse (2A) status. 4. Put on the lids of the central unit and verify if every zone is corresponding to its LED without starting alarm if the system is in disarmed mode. If some of the sensors are starting alarm in disarmed mode, it means the sabotage and alarm circuits are wired incorrect. If a trouble with the zone 4 occurs ( permanent lighting on of indication LED or alarming at every switching of the zone), check both tampers in the central unit.