P Zone Expandable Hybrid Security System

Similar documents
System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

WIRELESS CONTROLS & DETECTORS

System Introduction. 1.1 Specifications

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

System Introduction. 1.1 Specifications S E C T I O N 1

System Overview. PC4020 v3.3

INTRODUCTION. The use of any power source other than a PC4204 to repower the Combus will result in a system malfunction.

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

DS7400Xi Addressable Control/ Communicator

Installation Manual. This panel will not operate if installed outside of North America. See section 1.1 for details.

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

PC4020 v3.2 Installation Manual DLS-3 v1.3

WARNING Software Version 2.3 / DLS-1 v6.7 and up See Back Cover for New Features in Version 2.3

Programming Worksheets

Contents. Glossary

System Manual W A R N I N G. PC6O1O Software Version 2.1

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Installation Manual. PC1565 Software Version 2.4ZD DLS-3 v1.3 and higher

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

PC4020 v3.2 Installation Manual DLS-3 v1.3

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

EVO192 v3.0 Fire and Burglary What s New

Installation Manual RF55O1-433

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

Control/Communicator Installation Manual

TABLE OF CONTENTS TABLE OF CONTENTS 1

Installation Instructions

Installation Guide. NT9010 v 1.0. DLS-3 v1.3 and higher

Contents. Programming Worksheets 22. Appendix A: Guidelines for Locating Smoke Detectors 27. Index 28

Installation Manual Premier 412/816/832. Issue 10

All-In-One Wireless Security System V1.0. Model #: MG-6060

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Table of Contents. Appendix A Special Characters 31

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

Power864. User s Guide. Now classified in accordance with ANSI/SIA CP (SIA-FAR)

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

INSTALLATION MANUAL DV8OOO. Software Version 1.0

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

CC408. Quick Reference Guide Solution 880

CC488. Quick Reference Guide Solution Ultima 880

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

IDS816 User Manual H Issued January 2009

AXI LED USER MANUAL (REV. 1.0)

INSTALLATION MANUAL PC56O. Version 1.OA

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

PowerSeries. PC1616/PC1832/PC1864 version 4.1. Installation Guide

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

Power864. Installation Manual IMPORTANT. PC5O2O Version 3.1 DLS-3 v1.3 and higher

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

ITI Caretaker Basic Commands

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

Digiplex Control Panel (DGP-848) - V4.0

X64 Wireless Training

Series. NX-4-EUR Control Panel. Installation manual

Watchguard WGAP864 User Manual

RE6100 Series Helix Security and Automation Platform

SPECIFICATIONS Control Panel Specifications Remote Keypad Specifications 21 zones including: (PC3000RK) Audible alarm output:

RUNNER 8/64. 8/64 Zones Control Panel. Program Summary Guide

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

DSC PowerSeries NEO Quick Start Guide

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

Flair 500 Series Annunciators

Technical Manuals Online! - Keypad Programming. Basic Programming

INSTALLATION MANUAL PC15OO

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

ACP10 & ACP50 Security Systems

NX-148 LCD CODE PAD TABLE OF CONTENTS

PowerSeries. PC1616/PC1832/PC1864 version 4.2 NA. Installation Guide

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

ALARM CONTROL PANEL AND DIALLER USER S MANUAL. Revision 4.5 A$15.00 INC GST. Ness D8 control panel User s manual

Control/Communicator

All-In-One Wireless Security System V1.0. Model # MG Programming Guide

PRODUCT CATALOG. Concord Family Product Catalog. December 1999

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Property of Monitronics Inc

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

DESTINY OWNER S MANUAL

Solution-8248 Installation Manual ISSUE 1.16

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

(31/03/05) Version p1. INNER RANGE IQ. Programmer s Manual. Programmer s Manual Inner Range Pty. Ltd. Part Number:

Transcription:

Page 1 of 11 up to 8 hardwired keypads and 4 wireless keypads 4 hardwired keypads available with zone input PWLS910 wireless handheld keypad added wireless control is provided by - PWLS908 wireless panic pendant - PWLS909 wireless key Hardwired - P832-08Z eight zone LED keypad - P832-16Z sixteen zone LED keypad - P832-32Z thirty two zone LED keypad - P832-LCDZ alphanumeric keypad 8 zones on main panel 8 keypad zones P5108-8 zone expansion module P5108L - 8 zone expansion module plus Downlook video on P-832DL panels P5100-32 zone addressable multiplexed loop interface module P5700 Canada only - 4 general purpose zones, 2 waterflow zones, 1 ground fault supports all major formats including SIA and Contact ID LINKS1000 cellular communication LINKS2150 and LINKS2450 long range radio communication DVACS communication using P5400 or P5720 modules Downlook video transmission using P5108L module with the P-832DL main control panel event initiated personal paging 3 phone numbers (3rd backs up primary number) 2 account numbers supports Central Station Two Way Voice and Home Intercom features using P5928 audio interface module, P5922 intercom stations, and P5904 two way listen-in stations supports Downlook still frame video transmission using P5108L module with the P -832DL main control panel provides local VCR/monitor video switching for 8 cameras http://wwwpartnerproductscom/p-832/p-832htm

Page 2 of 11 zone, plus dual supervised telephone lines P5720 Canada only - 5 general purpose zones, 2 waterflow zone, 1 ground fault zone, plus printer or DVACS communications Wireless P5132-32 zone wireless zone expansion module up to 5 high current outputs 1 on main panel plus: P5204-4 output high current power supply module - 1 output fully supervised for siren output up to 9 low current outputs 1 on main panel plus: P5208-8 low current output module P5580 & P5580TC Escort provide voice assisted security and automation control for up to 32 X-10 devices plus thermostat control on the P5580TC 4 wire communications bus (KEYBUS) - connect modules up to 1000 (305m) from control panel - P5204-4 output high current power supply module provides up to 1A auxiliary power - main panel provides up to 550mA auxiliary power P-832 main control panel - alarm only P-832DL main control panel - alarm plus Downlook video capability support up to 32 zones using any combination of up to: - 8 hardwire zones on main panel - 8 hardwire zones using P5108L video matrix module (on P-832DL only) - 4 general purpose hardwire zones and 2 waterflow hardwire zones using P5700 fire module (in Canada only) - 24 hardwire zones using P5108 eight zone expander modules - 8 keypad zones - 32 wireless zones using P5132 wireless receiver module 2 system partitions 2 account numbers - each partition acts as a separate alarm system with any number of zones, user codes, keypads and individually programmable features 38-4 or 6 digit access codes - 32 user codes, 1 system master code, 2 partition master codes, 2 duress codes, and 1 maintenance code automatic arming by partition - each partition may be programmed to autoarm at its own time each day http://wwwpartnerproductscom/p-832/p-832htm

Page 3 of 11 zone programming - all zones programmable as burglary or fire - zone options include: Normally Closed loop, Single End of Line (EOL) resistor, and Double EOL resistor(1) (1)keypad zones cannot be programmed as fire zones and cannot support Double EOL resistor supervision - 27 programmable zone types, 8 programmable zone options audible alarm output - supervised bell output - 700mA @ 12Vdc, PTC protected, current limited at 3A - steady, pulsed, temporal pattern, or strobe fire output - additional supervised siren output is available using P5204 power supply module programmable voltage outputs - 1 high current 300mA PGM can also be used for 2 wire smoke with a maximum of 20 detectors at 15mA per detector - 1 low current 50mA PGM - 8 additional low current PGM outputs using P5208 module 4 additional high current PGM outputs using P5204 module 24 programmable options local PCLINK and remote upload/download capability - program system using Comm-Link DLS software and direct PC connection to control panel or via remote PC over telephone line - view status and trouble conditions, and system 128 event buffer - remote access can be controlled by owner to prevent unauthorized access to system power supply - 550mA @ 125Vdc auxiliary power (400mA for UL applications) - positive temperature coefficient (PTC) protected battery, AUX, and Bell output - electronic protection of KEYBUS - supervision of AC power loss, low battery, auxiliary power failure - internal clock locked to AC power frequency EEPROM memory keypad lockout - panel can be programmed to lockout keypad if a series of incorrect access code entries are made quick arm and quick exit - allows users to arm and exit easily stay/away zones and stay arming - security of perimeter arming while premise is occupied door chime - programmable by zone - monitor a door by having keypad beep when the door is opened and again when door is closed 128 event buffer - all events automatically stored with time and date stamp to buffer - events can be printed on-site using the P5400 serial printer interface module, viewed through an LCD Keypad, or viewed and printed via PC using Comm-Link DLS software The system continuously monitors the following trouble conditions AC power failure trouble by zone fire trouble telephone line trouble low battery bell output trouble loss of internal clock tamper by zone fail to communicate aux power supply fault module fault (supervisory or tamper) camera troubles (on P-832DL with Downlook) audible exit delay audible exit fault http://wwwpartnerproductscom/p-832/p-832htm

Page 4 of 11 - will not lose programming or system status on complete AC and battery failure digital communicator - supports all major formats including SIA & Contact ID - supports LINKS1000 cellular communications - supports LINKS2150 and LINKS2450 long range radio communications - 3 phone numbers (3rd backs up primary) - 2 account numbers - DTMF or pulse dialing - DPDT line seizure - anti-jam feature - split reporting of selected events to each telephone number - event initiated personal paging battery required: 12V, 4Ah, rechargeable sealed lead acid transformer required: 165Vac, 40VA quick exit urgency on entry delay swinger shutdown cross zone alarm recent closing transmission burglary verified timer* double hit timer* communication delay rotating keypress buffer arm/disarm bell squawk * on P -832DL v22x and higher The P-832 security system is fully programmable from the attractive, easy to use dual-language P832-LCDZ keypad: The P-832 system is fully programmable from any of the attractive, easy to use, LED keypads: 3 keypads available: http://wwwpartnerproductscom/p-832/p-832htm

Page 5 of 11 connect up to 8 keypads, combination LED and/or LCD zone input - connect detector to keypad to avoid separate wiring back to panel multi-language (languages vary according to country) - supervised bell output - 700mA @ 12Vdc, PTC protected, current limited at 3A - steady, pulsed, temporal pattern, or strobe fire output - additional supervised siren output is available using P5204 power supply module - simple key entry to toggle between languages while viewing keypad rotating keypress buffer reduces access code entry false alarms large 32 character display - zone identification - system instructions - system status - 128 event buffer - trouble conditions plain language operating instructions - menu for user functions - what key to press for specific functions - steps for programming functions automatic scrolling of alarms in memory - scrolls through alarms in memory while keypad is idle 12 hour or 24 hour clock display 5 programmable function keys with 25 options such as Home Arm, Away Arm, Quick Exit etc 4 keypad-activated alarm: Fire, Auxiliary, Panic, and Duress 3 LED indicators: Ready, Armed and Trouble - allow system status to be viewed at a glance P832-08Z P832-16Z P832-32Z zone input - connect detector to keypad to avoid separate wiring back to panel rotating keypress buffer reduces access code entry false alarms 5 programmable function keys with 25 options such as Home Arm, Away Arm, Quick Exit etc LED indicators: Ready, Armed, Trouble, Memory, Bypass, Fire, Program 4 keypad-activated alarms Panic, Auxiliary, Fire, and Duress backlit display with Backlighting Boost to provide extra high key lighting when any key is pressed piezo buzzer provides audible feedback for correct key entries, pre-alert, and system trouble status with adjustable buzzer tone connect to 4 wire KEYBUS up to 1,000' (305m) from control panel specifications 8 zone LED keypad 16 zone LED keypad 32 zone LED keypad - current draw: 85mA with backlighting boost - dimensions: 575"W x 45"H x 1"D (144 x 114 x 25mm) both P5400 and P5400DV may be used at the same time on a system provides RS232 serial printer connection for report of events logged to the system event buffer prints event, partition, time, and date that event occurred http://wwwpartnerproductscom/p-832/p-832htm

Page 6 of 11 backlit display - display and keys backlit for easy viewing in low light conditions - adjustable brightness and contrast - Backlighting Boost provides extra high key lighting when any key is pressed piezo buzzer - provides audible feedback for correct key entries, pre-alert, and system trouble status - adjustable buzzer tone connect to 4 wire KEYBUS up to 1,000' (305m) from control panel specifications - current draw : 85mA with backlighting boost - dimensions : 575"W x 45"H x 1"D (144 x 114 x 25mm) supports any 300, 1200, 2400 or 4800 BPS serial printer connect printer up to 200' (61m) from P5400 connect P5400 up to 1,000' (305m) from control current draw: 65mA @ 12VDC maximum one module per system both P5400 and P5400DV may be used at the same time on a system provides ULC Level 3 Line Security provides full DVACS reporting of all system events module is pre-programmed to SIA zone definitions events simultaneously communicated via DVACS and other installed communications mode such as digital or cellular full cross supervision between the system control panel and the DVACS module eg problems with one will be communicated to the central station by the other central station requires Sur-Gard a zone expansion module which can also be used to provide either a serial printer or DVACS communications interface 8 zone inputs include: - 2 ClassA supervisory waterflow zones - ground fault detection zone - 5 general purpose fire or burglary zones as RS232 printer interface: - baud rates 300, 1200, 2400, 4800 - connect printer up to 200' (61m) from the P5720 module as DVACS interface: same as P5400DV http://wwwpartnerproductscom/p-832/p-832htm

Page 7 of 11 receiver with DVL2A version 2 or higher software complete with 8 pin jack, and communications and power cables for connection to F1/F2 subset connect up to 1,000' (305m) from control module current draw: 65mA @ 12VDC adds 8 hardwired general purpose burglary or fire zones provides 100mA @ 12VDC auxiliary current, PTC protected connect up to 1000' (305m) from control module current draw: 35mA @ 12VDC add 32 DSC addressable devices on a 2- wire multiplexed loop Devices include: - Partner AMA-100 glassbreak detector - Partner AMS-220 series photoelectric smoke detectors - Partner AMB-300 PIR motion detector - Partner AMB-500 ceiling mount 360 PIR - Partner AMB-600 dual element pet immune PIR - Partner AMP-700 series contact modules connect up to 1,000' (305m) from control module current draw: 40mA @ 12VDC addressable loop maximum current draw: 170mA @ 12VDC compatible with P-832v2x and P- add up to 32 DSC wireless detectors* including: - PWLS904 passive infrared alarm - PWLS906 photoelectric smoke alarm - PWLS907 universal transmitter/contact - PWLS912 glassbreak detector - PWLS914 dual element pet immune PIR - PWLS915 door/window contact - PWLS917 recessed door/window contact 900MHz true Spread Spectrum technology, fully supervised for communication integrity easy sensor enroll process supervisory transmissions every 12 minutes programmable 1-24hr supervisory window connect up to 1,000' (305m) from control module current draw: 130mA @ 12VDC PWLS908 Wireless Panic Pendant - communicates a non-medical alarm to central station http://wwwpartnerproductscom/p-832/p-832htm

Page 8 of 11 832DLv2x or higher a zone expansion module which provides: - dual supervised telephone lines - 2 Class A supervisory waterflow zones - ground fault detection zone - 4 general purpose fire or burglary zones tamper and trouble reporting codes connect up to 1000' (305m) from control module current draw: 150mA @ 12VDC - 32 pendants maximum each occupying 1 alarm zone - sealed non-replaceable battery PWLS909 Wireless Key - remote arm/disarm control - up to 16 keys per system - 3 photo/electronic 15V batteries included PWLS910 Wireless Hand-Held Keypad - personal remote keypad - up to 4 wireless keypads per system (in addition to hardwired keypads) - 3 'AAA' batteries included turns any touch-tone phone into a fully functional keypad with Global and Partition control built-in power line interface for control of 32 X -10 automation control devices - 16 schedules with On Time, Off Time, and Day of Week P5922 Internal Intercom Station also available: P5922EXT external intercom http://wwwpartnerproductscom/p-832/p-832htm

Page 9 of 11-8 user controlled automation modes - full range of dimming levels for lighting control - event activated control for any PGM output supported by the main panel an extensive library of voice prompts for security and automation operation, programming, and system status feedback - 250 system words for pre-programmed system functions - 240 word library for user programmable voice prompts for Automation Item Labels, Automation Mode Labels, Partition Labels, and Zone Labels program up to 6 words per voice label powerful say number command can announce numbers from 0-999 in three different ways connect up to 1000' (305m) from control module current draw: 150mA @ 12VDC all the features of the P5580 Escort plus thermostat control supports up to four EMS-100 thermostats EMS-100 has 4 temperature control modes: - day occupancy mode - night occupancy mode - auxiliary occupancy mode - away occupancy mode each thermostat optionally supports: - up to six EMS-ITS remote indoor temperature sensors for interior temperature averaging - one EMS-OTS outdoor temperature sensor for display of outdoor temperature station P5922EXT/R external intercom station with relay for operation of existing door bell P5928 audio interface module - provides 7 output ports for connection of P5922 Series Intercom Stations - connect up to 1,000' (305m) from control panel via KEYBUS local intercom functions: - page/answer - do not disturb - doorbell function - door strike release listen-in broadcast allows any station to be programmed as a broadcast station to which all other internal stations in the system may listen in programmable as sounder for fire/burglar alarms answer telephone calls received on regular voice line - ringing programmable by station - supports call waiting - allows call transfer to in-house phones audio user help - provides plain language prompts for system programming, operation, and system status reports when installed with P5580 Escort Voice Prompt Module and keypads mounted with P5922 Intercom Stations P5904 central station 2-way listen-in station - programmable control tones (from central station) - select zone, listen/talk, extend on-line time, hang up http://wwwpartnerproductscom/p-832/p-832htm

Page 10 of 11 provides an interface between the P- 832DL alarm control panel and the Downlook DLM-4L still frame video transmission module communicates alarm followed by video over a single telephone line in one transmission to a Sur-Gard MLR2 digital receiver 8 inputs for video cameras, VCRs, or video switchers 8 general purpose burglary or fire alarm zone inputs any alarm zone (up to 32) or group of zones can be programmed to initiate video capture of 4 frames from any 4 sources - in any sequence programmable on-site sequential video switcher mode - view and capture images on a monitor / VCR setup - select cameras for viewing manually using an LED keypad or program system to switch automatically between selected cameras at programmed dwell times supervised by main panel programmable via downloading using modem or direct PC-Link provides 1A @ 125Vdc auxiliary power for additional modules and devices includes 4 fully programmable high current outputs - rated at 1A @ 12Vdc, PTC protected - will provide 3A short term if battery backup connected - each output can sink up to 3A output #1 may also be used as a supervised bell output - 700mA max each output programmable to activate for any of 24 options connect up to 1000' (305m) from control fully supervised for: tamper, low battery, AC power loss, and auxiliary power trouble maximum 1 module per system module current draw: 20mA @ 12VDC battery required: 4Ah minimum transformer required: 165Vac, 40VA module provides 8 low current transistor switch outputs - each output can sink up to 50mA - up to 250mA max at one time each output programmable to activate for any of 24 options http://wwwpartnerproductscom/p-832/p-832htm

Page 11 of 11 connect up to 1,000' (305m) from control module current draw: 60mA @ 12VDC connect up to 1000' (305m) from control fully supervised for tamper maximum 1 module per system module current draw: 20mA @ 12VDC P-832 Engineer s Specifications are available on separate copy and on the Partner web site Back to Products List Top of Page http://wwwpartnerproductscom/p-832/p-832htm