costruttori di sicurezza POWER SUPPLY UNITS Security Alarms - Fire Alarms - CCTV

Similar documents
Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard

INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX

v1.0.0 POWER SUPPLIES 2016

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

DIGITAL LIGHT CONTROLLER

CALL YOUR SALES CONSULTANT TODAY,

For Complete Fire and Gas Solutions

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

INSTALLATION INSTRUCTIONS

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing

MULTIFUNCTIONAL SYSTEM

SAFETY/ SECURITY - FIRE FIGHTING INTEGRATED SYSTEMS

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Installation, Operating and Maintenance Manual

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

TECOM SYSTEMS NETWORK MASTER

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

MANUAL RESET ALARM RELEASE

XC10 Extinguishing control panels

more than just power! Altronix is the professional security industry s leading manufacturer

Model 4001 Series Single Channel Controller

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

NEO XL NEO XL NEO XL POWER SUPPLIES - MADE IN SWEDEN ENGLISH

intelligent solutions

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

System 800 Addressable Fire Detection & Alarm System

Functional Performance Test

Fire Control Panel FS4000

Model 17A00 Expansion Enclosure

Electronic timeswitch

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Dräger REGARD -1 Control System

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

Intrusion Outdoor Protection Perimeter

EVO192 v3.0 Fire and Burglary What s New

Section PERIMETER SECURITY SYSTEMS

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Intelligent addressable fire alarm control panel

Heat Sensor Cable Alarm Units DT650L / DT950L

Bristol Babcock Oil Content Monitor "oil in water"

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Colour Observation System

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Esmi Sense FDP Fire detection panel with ALC2 loop controller

INDEX WARNINGS AND RECOMMENDATIONS 2 COMPLIANCE DECLARATIONS 3 RANGE AND SIZES 3 ELECTRICITY SUPPLY 3 INSTALLATION 4 INSTRUCTIONS FOR UNINSTALLING

EnvironmentalMonitoring

The EN54 Part 2 and 4 Fire System

CONTROL DEVICE SLIDETRONIC HD

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Addressable and Conventional Fire Protection

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

Components Brochure DX CONNEXION

Battery Powered Digital Mass Flow Meters for Gases

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

FEC400 Series. Installation Manual

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

FireNET Plus Wiring Instructions

631RF Amp Power Supply

ZM20 OEM Technical Manual

STATUS ALARM HISTORY ALARM RESET

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

Conventional Fire Alarm System 2014 V1.2

Unity DAU Voice Alarm System

CODESEC FIRE ALARM SYSTEMS. security technologies

Increased safety and reducing energy consumption with the motion control RPI 01

Installation and user manual for the BiWire / Conventional Repeater Panel

AL600ULX Series. Power Supply/Charger. Installation Guide

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

AL600ULADA. NAC Power Extender. Installation Guide

SECTION (13730) - INTRUSION DETECTION

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Battery charger modules

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Fire Alarm Control Panel. System Maintenance and Log Book

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

Loadstar AC/DC Systems

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Sonos-SB Siren/Beacon

Control Panel Engineering and Commissioning Instructions

EASY THE SECURITY SYSTEM BUILT AROUND YOU

CONTROL PANELS. Tech Data Sheet D01688GB1 10/2012 Fire Detection. Control Panels of the FX 3NET (ALC) Fire Detection System

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Door Release Power Supply

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Transcription:

costruttori di sicurezza POWER SUPPLY UNITS Security Alarms - Fire Alarms - CCTV

costruttori di sicurezza Power Supply Units Security Alarms - Fire Alarms - CCTV Wolf Safety is one of the leading manufacturers of power supplies for security systems requiring lead acid standby batteries. With 7 different power units and housing in 4 sizes, designed to accommodate a varied range of batteries and the most up-to-date circuit boards, our range is one of the most extensive and versatile currently on the market. Variable combinations of power supplies, housing and high-performance circuit boards allows us to provide exceptionally functional units capable of meeting even the most demanding installation requirements. The reliability and quality of our systems are IMQ certified. IMQ certified 13 and 7V power supplies with double insulation 13 and 7 V 7Ah power supply battery chargers. The technology adopted ensures maximum isolation, input surge protection, minimum heat generation and exceptionally compact units. Elevated efficiency and output quality make this a highly trustworthy power supply suitable for use with all burglar/intruder and fire alarms, CCTV and surveillance systems. IMQ certification guarantees quality and reliability. W-AL-13100 W-AL-130C W-AL-1340C W-AL-1370C W-AL-70C W-AL-740C W-AL-770C 13V - IP40 13V 13V 13V 7V 7V 7V, 3,6A 6,9A A 3,4A 6,4A Power supply unit and battery housing model dim. (mm) battery power supply control board UA UB UC US 340x30x115 345x385x13 395x385x185 190x30x80 1x18Ah - x7ah x18ah 1x70Ah - x7ah 1x7Ah 13100-130 1340-70 W-AC-BAT with tamper all greater than W-AC-BAT with tamper W-AC-BAT with tamper 13100-130 1340 tamper only A modular system composing of metal containers of various sizes deigned to accommodate Wolf Safety power supplies and batteries up to 70Ah. The unit includes a discharged battery LED and alarm relay. The containers are supplied separate from the power supply units to ensure safe transportation and facilitate wall mounting of the container. Orders for power supply units and containers are handled separately.

Power supply units for burglar/intruder alarm systems IMQ certified to EN50131-6 The current European Standard EN50131-6 defines the minimum requirements for burglar/intruder alarm power supply units and emphasizes operational safety. WOLF SAFETY has 4 power supply models from A to 6.9A for batteries from 7.Ah to 70Ah. The larger sizes are reserved for higher degrees of security and include a battery tester and faulty battery signal alarm relay. A 70Ah battery with a h load can sufficiently power an alarm system for up to 70 hours, a whole weekend from Friday evening through to Monday morning. unit and dimension power supply battery EN50131-6 grade max power supply current recharge battery UA 130 7Ah A 0,5A 1,5A max current for load Current and autonomy grade grade 3 + notice grade 3 1h 30h 60h 0,55A Detched battery a 1,7 for element = 10V UA - 340x30x115mm UA 130 UA 1340 18Ah 7Ah A 0,5A 3A 0,55A UA 1340 18Ah,5A 1,45A UC - 395x385x185mm UC 1340 7Ah 3 1,5A A A 0,85A UC 1370 7Ah 3 6,8A 1,5A 5,3A,A 0,85A UC 1370 70Ah 3 6,8A 3,3A a 0h,A 0,4A 0,4A 1, EN54-4 requirements - For certification EN54-4 and EN 50131-6 In the absence of the main power source, the unit shall automatically switch to the battery without any interruption. The unit shall recharge the battery automatically to at least 80% of its rated capacity within the first 4 hours and to its rated capacity within another 48 hours and the charging characteristics are within an ambient temperature range of -5 C to +40 C. The unit shall ensure that the power supply is sufficient to satisfy the demand of the load, even in the absence, malfunction and/or short circuit of the battery.

ECO POWER high efficency power supply ECO lines: - Very high efficiency up to 95% - High power up to - High reliability MTBF>>100.000 Hours - High isolation SELV Classification Rack box for batteries up to 100 Ah Applicazioni: - fire detection system according to EN54-4 requirement; - EVAC, vocal evacuation system according to EN54-4 requirements; - smoke and heat evacuation according to EN11-10. Wall-mounting up to 4Ah batteries Power supply units for fire alarm systems certified EN54-4 and CPR Wolf safety offers five certified fire protection system power supply units of up to 6.4Ah with space for batteries up to 7Ah. The units consist of a standard Wolf Safety 7V power supply assembled in one of two different sized metal boxes. The fire alarm panel is fully compliant with the requirements of EN54 and includes a battery charger /failure monitor and signals 15 different power supply unit states and all the alarm signals specified by the Standard. All the systems come with a choice of three battery sizes and are fully certified. CERTIFICATATION RELATED TO CHECK SMOKE AND HEAT DEVICES unit dimension UB - 345x385x185mm UC - 395x385x185mm model W-UB-70ENC W-UB-740ENC W-UB-770ENC* W-UC-740ENC W-UC-770ENC battery x, 7, 18Ah x7,ah 18Ah x7,ah 18Ah x7, 18 7Ah x7, 18 7Ah power supply W-AL-70C 7V A W-AL-740C 7V 3,4A W-AL-770C 7V 6,4A W-AL-740C 7V 3,4A W-AL-770C 7V 6,4A current for load 1,4 1,4 0,9,3,3,3 4,8,3,3 1,8,3 4,8 4,8 The unit shall display the operating state of the system and in particular report the following failures: a. loss of the main power source, within 30 minutes of the occurrence; b. loss of the standby power source - battery- (power, detachment, short circuit) within 15 minutes of the occurrence; c. spent battery when the charge is not sufficient to satisfy the load declared for the power supply, within 4 hours of the occurrence; d. breakage in the charging circuit and associated circuits, within 30 minutes of the occurrence. From: Wolf Safety project specifications for EN54 Controller

VANTAGE Buck boost voltage convertor, Ground Loop supressor For CCTV power supplier application - Supply source from burglar alarm systems with 13,8V back up battery. - End-of- line Voltage below 1. - Centralized 4V AC transformer, for outdoor application. - Slow moving grey band noise suppression. Out 1 V 13,7 Vcc 1-4 Vca Minimun supply requirements end minimum line 10,5 Vcc/ 1Vca The solution to problems of inadequate voltage and ground loop + Ground Loop CCTV power supplies with backup battery W-AC-401 1.6A electronic voltage regulator. Especially designed to protect video cameras with infrared illuminators. Powered by a 7V power unit with a buffer battery, this regulator provides a stabilized output of 1V. Advantages: - zero voltage drop over distances; - avoids line noise and protects the video camera; - reduced dimensions 5x36x8 mm to facilitate installation; - at 7V absorption is halved compared to the current supplied to 1V and therefore doubles the life of the batteries; - backup power to the VCR with a regulator capable of delivering up to 7A, calibrated upon request from 1V up to 19V 7V 1 Vdc 30V W-AC-401 7V 10 19 Vdc Until 7 A W-UB-770 18 Ah; W-UC-770 7 Ah W-AL-140S W-UA-1370TVBAT and W-UA-1340TVBAT These units will correctly charge batteries at 13.7V and supply video cameras with a stabilized 1V, which avoids damage to the infrared illuminators. Advantages: - backup power when main line is down; - power output up to 6A and batteries up to 18Ah for W-UA-1370 and up to 3A with a 7,Ah battery for W-UA-1340; - output current measuring point; - 8 output terminals with a 900 ma self-resetting fuse; - settings for voltage compensation drops; - external dimensions: 340 x 30 x 115 mm.

ENG 10/017 costruttori di sicurezza Wolf Safety è un marchio registrato di ELP s.n.c. ELP Snc è azienda certificata secondo gli standard ISO 9001:008 I prodotti WOLF rispettano i principali standard qualitativi Europei 1010 ARSAGO SEPRIO (VA) Via Tornago, 36 Tel. 0331 767 355 - Fax 0331 90 81 www.wolfsafety.it - info@wolfsafety.it