VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

Similar documents
VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation instructions VITOCROSSAL 300. for contractors. Vitocrossal 300 Type CM3 Gas condensing boiler with MatriX radiant burner

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

VIESMANN. Installation and service instructions. EHE immersion heater. for contractors. EHE immersion heater

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

VIESMANN. Installation instructions. Mixer extension kit. for contractors. Mixer extension kit. For one heating circuit with mixer

VIESMANN. Installation instructions. Extension AM1. Safety instructions. for contractors. Part no

VIESMANN. Installation instructions VITOCROSSAL 200. for contractors. Vitocrossal 200 Type CM2 Gas fired condensing boiler with MatriX radiant burner

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation and service instructions VITOTROL 300A. for contractors. Vitotrol 300A. Remote control, part no

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

VIESMANN. Installation instructions VITODENS 200-W. for contractors

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

Installation instructions PYROMAT ECO. for contractors PYROMAT ECO GB 8/2012 Dispose after installation.

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation instructions. Extension EA1. Safety instructions. for contractors. Part no

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

VIESMANN. Operating instructions VITODENS 100-W. for the system user

VIESMANN. Operating instructions VITODENS 111-W. for the system user

VIESMANN VITOLADENS 300-C Oil condensing boiler 12.9 to 28.9 kw

VIESMANN VITOLADENS 300-T Oil Unit condensing boiler 35.4 to 53.7 kw

VIESMANN. VITOMAX 200-WS Rated heating output 1.75 to MW. Datasheet. VITOMAX 200-WS Type M250

VIESMANN. Operating instructions DIGITAL TIME SWITCH. for the system user. Digital time switch for the Vitodens 100-W, type WB1B

VIESMANN. Datasheet VITOMAX 200-WS. Hot water boiler for permissible flow temperatures up to 110 C 1.75 to MW

VIESMANN. Installation and service instructions VITODENS 050-W. for contractors

VIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.

VIESMANN VITOLADENS 300-C Oil condensing boilers 12.9 to 28.9 kw

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

VIESMANN. Service instructions VITOCROSSAL 300. for contractors. Vitocrossal 300 Type CR3 and CR37, 787 and 978 kw Gas condensing boiler

for contractors Vitoplex 200 Type SX2A For applicability, see the last page Please keep safe.

VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw

VIESMANN VITOROND 100. Datasheet Part numbers and prices: see pricelist VITOROND 100. Cast iron low temperature oil and gas fired boiler.

VIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw

VIESMANN. Service instructions. MatriX radiant burner. for contractors

VIESMANN. Installation and service instructions VITOCAL 200-S. for contractors

Installation and operating instructions. DK energy storage and DK energy buffer

Installation Instructions for use by heating contractor. VITOCELL r 100-B CAUTION IMPORTANT. Read and save these instructions for future reference.

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

Start-up/Service Instructions for use by heating contractor. VITOCELL r 300-V VITOCELL r 300-B IMPORTANT

aurostor Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VIH S GB...

Installation, operating and servicing instructions

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Powerstock Storage Tank

VIESMANN. Installation and service instructions VITODENS 050-W. for contractors

Installation and maintenance instructions

Service instructions. FM443 solar module. Function module. For contractors. Read carefully prior to commissioning or service

T E C H C A L EBS-1 T High technology heating

Installation and maintenance instructions

Installation instructions

Installation and User Instructions HS10U, HS15U.

Installation Instructions for use by heating contractor. VITOCELL r 100-V CAUTION IMPORTANT. Read and save these instructions for future reference.

Valves, controls + systems. Regucor WHS Energy storage centre. Innovation + Quality. Product range. v o. Awards: i y. n n

Instructions for Use Installation and Servicing

and Installation Instructions The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack.

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

VITOSOL r DHW SOLAR PACK

Gas 220 Ace Cascade Assembly Manual

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

VIESMANN. Installation and service instructions VITODENS 111-W. for contractors

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

VIESMANN. Operating and service instructions VITOMAX 200-HW. for contractors

HOTFLO 10 / 15. Fitting Instructions and User Guide

Installation and maintenance instructions

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Unvented Electric Water Heater 10/15 litre Undersink

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

SEALED THERMAL STORE

CIRCO 6 Solar Circulation Unit

VIESMANN. Installation and service instructions VITOCAL 300-A. for contractors

HERZ Differential Pressure Control Valve 4002

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Technical Data Manual Model Nos. and pricing: see Price List

ADVANCE ELECTRIC THERMAL STORE

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

VIESMANN. Installation and service instructions VITOCAL 300-G. for contractors

Technical information Installation instructions. Modul-plus (F21-52) High performance calorifiers

Multipoint Technical Data

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

Floorstanding Gas Condensing Boilers VITOCROSSAL 100

VIESMANN. Datasheet For part no. and prices: see pricelist VITOLIGNO 300-P. Pellet boiler 4to48kW. Vitotec folder, register 12. File in: Type VL3B

Installation Instructions for use by heating contractor. VITOCELL r 300-H CAUTION IMPORTANT. Read and save these instructions for future reference.

/99 USA. Installation Manual SU Save These Instructions!

Baxi Maxflow Combi WM

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

Commercial Hot Water Solutions Ltd.

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

Transcription:

Installation instructions for contractors VIESMANN Vitocell 300-B Type EVBA-A Dual mode DHW cylinder, 300 and 500 l VITOCELL 300-B 1/2017 Dispose after installation.

Safety instructions Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained! Danger This symbol warns against the risk of injury. Please note This symbol warns against the risk of material losses and environmental pollution. Note Details identified by the word "Note" contain additional information. Target group These instructions are exclusively intended for qualified contractors. Work on electrical equipment may only be carried out by a qualified electrician. Regulations to be observed National installation regulations Statutory regulations for the prevention of accidents Statutory regulations for environmental protection Codes of practice of the relevant trade associations All relevant safety regulations as defined by DIN, EN, DVGW, VDE and locally applicable standards a ÖNORM, EN and ÖVE c SEV, SUVA, SVTI, SWKI and SVGW Working on the system Isolate the system from the power supply (e.g. by removing the separate fuse or by means of a mains isolator) and check that it is no longer live. Safeguard the system against reconnection. Wear protective clothing.! Please note Electronic assemblies can be damaged by electrostatic discharge. Prior to commencing any work, touch earthed objects such as heating or water pipes to discharge static loads. Danger Hot surfaces can cause burns. Before maintenance and service work, switch OFF the appliance and let it cool down. Never touch the hot surfaces of uninsulated pipes and fittings. Repair work! Please note Repairing components that fulfil a safety function can compromise the safe operation of the system. Replace faulty components only with genuine Viessmann spare parts. 2

Index 1. Information Disposal of packaging... 4 Symbols... 4 Intended use... 5 Product information... 5 2. Preparing for installation Connections... 6 Siting information... 6 Siting the DHW cylinder with immersion heater... 7 3. Installation sequence 300 l capacity... 8 Installing leads for the thermometer sensor and temperature controller sensor... 8 Installing the sensor well and the cylinder temperature sensor... 9 Fitting the flange cover... 10 500 l capacity... 11 Siting the DHW cylinder and fitting the thermal insulation mat at the bottom... 11 Fitting the thermometer sensor (if supplied) and cylinder temperature sensor... 12 Fitting the thermal insulation jacket... 13 Fitting the cover strips... 14 Fitting the cover... 15 Fitting the cylinder temperature sensor for solar operation... 15 Connections on the heating water side... 15 Heating DHW by solar collectors... 17 Heating DHW by a heat pump... 18 Connections on the DHW side... 19 Safety valve... 19 Connecting the equipotential bonding... 20 Commissioning... 20 4. Specification... 21 3

Disposal of packaging Please dispose of packaging waste in line with statutory regulations. DE: Use the disposal system organised by Viessmann. AT: Use the ARA statutory disposal system (Altstoff Recycling Austria AG, licence number 5766). CH: Packaging waste is disposed of by the HVAC contractor. Symbols Symbol 1. Meaning Reference to other document containing further information Step in a diagram: The numbers correspond to the order in which the steps are carried out. Warning of material losses and environmental pollution Live electrical area Pay particular attention. Component must audibly click into place. or Acoustic signal Fit new component. or In conjunction with a tool: Clean the surface. Dispose of component correctly. Dispose of component at a suitable collection point. Do not dispose of component in domestic waste. 4

Intended use The appliance is only intended to be installed and operated in sealed unvented systems that comply with EN 12828 / DIN 1988, or solar thermal systems that comply with EN 12977, with due attention paid to the associated installation, service and operating instructions. DHW cylinders are only designed to store and heat water of potable water quality. Heating water buffer cylinders are only designed to hold fill water of potable water quality. Only operate solar collectors with the heat transfer medium approved by the manufacturer. Intended use presupposes that a fixed installation in conjunction with permissible, system-specific components has been carried out. Any usage beyond this must be approved by the manufacturer for the individual case. Incorrect usage or operation of the appliance (e.g. the appliance being opened by the system user) is prohibited and results in an exclusion of liability. Incorrect usage also occurs if the components in the system are modified from their intended use (e.g. through direct DHW heating in the collector). Adhere to statutory regulations, especially concerning the hygiene of potable water. Commercial or industrial usage for a purpose other than heating the building or DHW shall be deemed inappropriate. Product information Stainless steel DHW cylinder with internal indirect coil for DHW heating in conjunction with solar thermal systems, floorstanding and wall mounted boilers and/or heat pumps for dual mode operation. Capacity: 300 and 500 l An immersion heater can be used. Suitable for systems conforming to DIN 1988, EN 12828 and DIN 4753 5

Connections A B C D A Fig. 1 300 litres E F G H K L A Temperature controller (upper indirect coil) (below the thermal insulation) B Cylinder temperature sensor and safety limiter (below the thermal insulation) C DHW D Heating water flow *1 (upper indirect coil) E DHW circulation F Heating water return (upper indirect coil) G Cylinder temperature sensor or temperature controller and thermometer sensor (lower indirect coil) *2 H Heating water flow *3 (lower indirect coil) K Heating water return and cylinder temperature sensor for solar operation *2*3 L Cold water Fig. 2 500 litres B C D E F A DHW B Clamp (behind the thermal insulation) for cylinder temperature sensor or temperature controller (upper indirect coil) C Heating water flow *1 (upper indirect coil) D DHW circulation E Heating water return (upper indirect coil) F Clamp (behind the thermal insulation) for cylinder temperature sensor or temperature controller and thermometer sensor (lower indirect coil) *2 G Heating water flow *3 (lower indirect coil) H Heating water return and cylinder temperature sensor for solar operation *2*3 K Cold water G H K Cylinder capacity Maximum connectable heat pump output (upper and lower indirect coils linked in series): 300 l 12 kw 500 l 15 kw! 6 Siting information Please note The thermal insulation must not come into contact with naked flames. Exercise caution when welding and brazing. *1 The upper indirect coil is designed for connection to a boiler. *2 Recommended positioning of the cylinder temperature sensor for solar operation: With threaded elbow (accessories) in the heating water return. *3 The lower indirect coil is designed for connection to solar collectors.

Siting information (cont.)! Please note To prevent material losses, install the DHW cylinder in a room free from draughts and risk of frost. When not in use, the DHW cylinder must be drained if there is a risk of frost. Provide adequate clearance from the wall to allow for operation of the temperature controller (if installed). Use the adjustable feet to level the DHW cylinder. Note Never extend the adjustable feet beyond a total length of 35 mm. Siting the DHW cylinder with immersion heater a Fig. 3 Immersion heater installation instructions Maintain the minimum clearance. Cylinder capacity Dim. a 300 l 730 mm 500 l 670 mm Note The unheated length of any threaded immersion heater installed on site must be at least 100 mm. 7

300 l capacity Installing leads for the thermometer sensor and temperature controller sensor 1. 3. A 8. 8. C 7. 4. 6. 2. 5. B 2. Fig. 4 A Type plate 8 1. Remove top panel, thermal insulation, and parts for flange cover installation. 2. Route the sensor lead of the lower thermometer downwards through the opening in the thermal insulation and the cable channel. 3. Push the sensor lead through the strain relief sleeve and route to the sensor well. 4. Fit the strain relief sleeve to the sensor well. 5. Push the cylinder temperature sensor into the sensor well as far as it will go. Note Never wrap insulating tape around the sensor. 6. Secure sensor lead with strain relief sleeve. 7. If a high limit safety cut-out is installed: Cut out opening A on flange insulation. Push high limit safety cut-out sensor B into clamping bracket, and secure with wing screw. 8. Remount the flange insulation and top panel.

300 l capacity (cont.) 9. Affix type plate C. Installing the sensor well and the cylinder temperature sensor Note The sensor retainer is in the sensor well. 1. Extract the sensor retainer. 2. Fit the sensor to the outside of the sensor retainer contact spring (not in the groove). Note The sensor must sit flush with the front of the spring. Never wrap insulating tape around the sensor. 2. 3. Insert the sensor retainer with sensor into the sensor well as far as it will go. 1. 3. 4. Fig. 5 9

300 l capacity (cont.) Fitting the flange cover 1. 2. Fig. 6 10

500 l capacity Siting the DHW cylinder and fitting the thermal insulation mat at the bottom 1. A 2. Fig. 7 A Type plate 11

500 l capacity (cont.) Fitting the thermometer sensor (if supplied) and cylinder temperature sensor 3. 5. 2. 1. 6. 7. A 4. 8. Fig. 8 1. Guide the thermometer sensor through the cover strip and insert the thermometer. Note The cover strip is held in its vertical position by the straight capillaries. This is necessary for the rest of the installation. 2. Insert the upper thermometer sensor as far as it will go into the hole in the cylinder cap. 3. Secure the thermometer sensor against being pulled out using clips. 4. Route the bottom thermometer sensor capillaries to the back of the cylinder body. 6. Push the clamps onto the threaded studs and align. 7. Tighten the nuts. 8. Depending on where the sensor is being fitted: insert the thermometer sensors and cylinder temperature sensors into clamp A as far as they will go. Note Never wrap insulating tape around the sensors. When the thermal insulation is being fitted, the cylinder temperature sensor leads are routed outwards through the apertures (slots) in the rear cover strip. 5. Screw the nuts onto the threaded studs. Do not tighten. 12

500 l capacity (cont.) Fitting the thermal insulation jacket Note Ensure that no fleece remnants enter the DHW cylinder through the cylinder connections. 2 people are required for the following work. 6x 2. 1. 6x 4. 6x 6x 3. Fig. 9 1. At the back of the cylinder: attach 6 clip fastenings to the edges of the right and left sections of the insulation jacket and lay the thermal insulation jacket around the cylinder body. Note Leave the clip fasteners in the first notch. 3. Push the clip fasteners at the back of the cylinder as close together as possible. 4. Push the clip fasteners at the front of the cylinder as close together as possible. 2. At the front of the cylinder: attach 6 clip fasteners to the edges of the right and left sections of the thermal insulation jacket. 13

500 l capacity (cont.) Fitting the cover strips 4. 3. A B 1. 2. Fig. 10 A Type plate 1. Fit the thermal insulation jacket evenly around the cylinder body by patting it. 2. Mount the front cover strip and flange cover. 3. Cut out openings B and mount rear cover strip. 4. Affix the type plate. 14

500 l capacity (cont.) Fitting the cover Note The soft side of the thermal insulation must rest against the cylinder body. A 1. 2. Fig. 11 A Cap with Viessmann logo Fitting the cylinder temperature sensor for solar operation 2. 1. Fig. 12 1. Seal threaded elbow and sensor well (accessories) into the heating water return connection (solar return). 2. Insert the cylinder temperature sensor (part of solar control unit standard delivery) into the sensor well as far as it will go and secure against slipping out. Connections on the heating water side Connect all pipework with detachable fittings. Seal any connections that are not required with red brass caps. Adjust the temperature controller and high limit safety cut-out so that the DHW temperature in the DHW cylinder does not exceed 95 C. For 300 l and heating water flow temperatures above 95 C: Remove the pipe collars from the pipe outlets on the heating water side (pipe collars have l.h. threads).! Please note The internal indirect coil is installed with gaskets. Temperatures > 150 C at the connections will damage the gaskets. Ensure an adequate safety distance when soldering and welding. Realigning the connector will damage the gaskets. 15

Connections on the heating water side (cont.) Permissible temperatures Solar side 160 C Heating water side 160 C Permissible operating pressure Solar side Heating water side Test pressure Solar side Heating water side 10 bar (1.0 MPa) 10 bar (1.0 MPa) 16 bar (1.6 MPa) 16 bar (1.6 MPa) 16

Connections on the heating water side (cont.) Heating DHW by solar collectors Via the lower indirect coil and heat supply for reheating or heating the DHW by means of a boiler via the upper internal indirect coil (parallel operation) 1 6 WW 2 3 KW 4 5 Fig. 13 1 Solar collector 2 Fill valve 3 Solar manual fill pump 4 DHW cylinder 5 Oil/gas boiler 6 Heating circuit KW Cold water WW DHW 17

Connections on the heating water side (cont.) Heating DHW by a heat pump Via the upper and lower indirect coils (coils connected in series) 4 WW 3 KW 1 2 Fig. 14 1 DHW cylinder 2 Heat pump 3 3-way valve 1. Install the heat supply control unit. 2. Only for heating water flow temperatures in excess of 110 C: Install an additional type-tested high limit safety cut-out if the system does not already have one. For this, use a TR/HLSC combination device (temperature limiter and high limit safety cut-out). 4 Heating circuit KW Cold water WW DHW 3. Close test ports that are not used for the installation of a sensor. Note For connections, see page 6. 18

Connections on the DHW side For connections on the DHW side, observe DIN 1988 and DIN 4753. c: SVGW regulations. Connect all pipework with detachable fittings. Seal any connections that are not required with red brass caps. Equip the DHW circulation pipe with a DHW circulation pump, check valve and time switch. Always install cylinder banks with connected DHW circulation.! Please note The internal indirect coil is installed with gaskets. Temperatures > 150 C at the connections will damage the gaskets. Ensure an adequate safety distance when soldering and welding. Realigning the connector will damage the gaskets. Permissible temperature: 95 C Permissible operating pressure: Test pressure: 10 bar (1 MPa) 16 bar (1.6 MPa) P H D E F G K M O K R K P L N K O S T C A Fig. 15 B A Expansion vessel B Drain C DHW circulation pipe D DHW E Spring-loaded check valve F DHW circulation pump G Visible discharge pipe outlet point (tundish) H Safety valve K Shut-off valve L Flow regulating valve M Pressure gauge connection N Non-return valve O Drain P Cold water R Drinking water filter S Pressure reducer T Non-return valve/pipe separator Safety valve The system must be equipped with a type-tested diaphragm safety valve as protection against overpressure. Permissible operating pressure: 10 bar (1 MPa). The safety valve must have the following connection diameter: R ¾ (DN 20), max. heat input 150 kw. If the heat input of the DHW cylinder exceeds 150 kw, select a sufficiently large safety valve for the heat input (see DIN 4753-1, issue 3/88, section 6.3.1). Install the safety valve in the cold water line. Ensure it cannot be shut off from the DHW cylinder. There must be no restrictions in the pipework between the safety valve and the DHW cylinder. 19

Connections on the DHW side (cont.) Never seal off the safety valve discharge pipe. Ensure that any expelled water is safely and visibly drained into a drainage system. Position a sign close to the safety valve discharge pipe, or ideally on the safety valve itself, with the following inscription: "For safety reasons, water may be discharged from the discharge pipe during heating. Never seal." Install the safety valve above the top edge of the DHW cylinder. Connecting the equipotential bonding Connect the equipotential bonding in accordance with the requirements stipulated by your local power supply utility and VDE regulations. c: Connect the equipotential bonding in accordance with the technical requirements stipulated by your local power supply utility and SEV regulations. Commissioning Service instructions 20

Specification Cylinder capacity l 300 500 DIN registration number Applied for Standby heat loss kwh/24 h 1.06 1.37 Dimensions Length a (Ø) Incl. thermal insulation mm 667 1022 Excl. thermal insulation mm 715 Width b Incl. thermal insulation mm 744 1084 Excl. thermal insulation mm 954 Height c Incl. thermal insulation mm 1734 1852 Excl. thermal insulation mm 1667 Height when tilted Incl. thermal insulation mm 1825 Excl. thermal insulation mm 1690 Weight incl. thermal insulation kg 112.4 122.2 Connections (male thread) Indirect coils G 1 1 Cold water, DHW G 1 1¼ DHW circulation G 1 1 21

22

23

24 Viessmann Werke GmbH & Co. KG D-35107 Allendorf Telephone: +49 6452 70-0 Fax: +49 6452 70-2780 www.viessmann.com Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP, GB Telephone: +44 1952 675000 Fax: +44 1952 675040 E-mail: info-uk@viessmann.com Subject to technical modifications.