THERMOCOAX Aeronautic Products : Grey Water Drain Mast Equipped with Electrical Anti-Icing System

Similar documents
MARC70 Installation Manual

Flange immersion heaters

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS MD SERIES TERRAIN AWARENESS ANNUNCIATION CONTROL UNIT FOR GARMIN TAWS SYSTEMS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

A D U ANNUNCIATOR DIM / TEST UNIT INSTALLATION MANUAL DESCRIPTION AND THEORY OF OPERATION

Screw plug immersion heaters

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Laird Engineered Thermal Systems Application Note. Liquid to Liquid Ambient Cooling Systems for Semiconductor Tools

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames.

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

ULTRA GALACTICA POSITION/NAV/STROBE LED LIGHT

SolderSleeve Insulated Electrical Termination Devices

CERTIFICATE OF ACCREDITATION

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Overmoulded Cable Assembly Selector Guide

Flight Crew Reading Lights

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS. MD41-151X Series Annunciation Control Unit For Garmin GPS Systems

C 46 K a d. Specifications EKMC K. Ver.1.1. Page: EKMC K. 1.Product Name. 2.Model Number. 3.Dimensions. Approved by.

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Manual. Belt Sander BSL 115/E. ProxxonTools.com

ANSI-ASQ National Accreditation Board/ACLASS

TAILORED S PECTRUM. Commercial Grow Luminaire SQRT670CX1 INSTRUCTION MANUAL

E-17 Flammable Gas Detection and Alarm System

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

O 3 SYSTEM. Taming the elements

Z-Plus. Temperature/Humidity Chambers.

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

Document No

IEC PROJETOS EM VOTAÇÃO SETEMBRO E OUTUBRO. IEC ED1 - Rotating electrical machines - Part 23: Repair, overhaul and reclamation

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

Coolers / Chillers. Accessories for oil cooled units. Overview. Accessories for water cooled units. Industrial X-Ray

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

Mar11 Rev C

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

LOCAL STORM DATA SHEET

Jun08 Rev C

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

water to water heat pumps

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

Heated tools. Semiconductor equipment

Product Training Module: Inertial Measurement Unit 6-D Motion Variant 6DF Series. Copyright 2013 Honeywell International Inc. All rights reserved.

USB 3.0 Plug & Receptacle

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

Environmental testing of aerospace equipment

Safety Scenarios. You enter the lab and discover that you will be boiling water in a beaker and pouring the hot water into a separate container.

GUIDELINES FOR THE APPROVAL OF HELICOPTER FACILITY FOAM FIRE-FIGHTING APPLIANCES

Differences Among Screw Plug Immersion Heaters

CO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr.

CLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Oil Mist Detection and Alarm Equipment

Explosion-proof Immersion Heater Type D-8660

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax:

FOS WATER LOW FOG 3000

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Table of Contents Categorized Listing

2010 Falcon 2000LX N801DE S/N 203 Specifications and Summary

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

8 Garda - LED 01A LED_AU_Garda.indd 8 27/12/16 09:57

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

A Specifications. Ver.1.1. Page: EKMC Product Name. Model Number. 3.Dimensions. Approved by. Checked by.

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

VM 500 LIST OF THE EXPLODED VIEWS. From s/n up Today. From s/n till s/n GRUPPO FRIGORIFERO GRUPPO FRIGORIFERO SHELL ASSY

High bay LED lighting fixture

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Sensor : IRA-S210ST01 Lens : IML-0685/0688 Pyro Electric Infrared Sensor Fresnel Lens Features Applications Excellent S/N Intrusion Detectors

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

CNBOP-PIB Standard Fire Protection

DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications

Z-Plus Temperature/Humidity Chambers

Federal Law of the Russian Federation of December 27, 2009 N 347-FZ "Technical regulation on safety of low-voltage equipment" Part I

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

RHT RAIL HEATER. Rail & Switch Point Heating System. Pre-Terminated Lengths or Cut-to-Length from the Reel

HOUSEHOLD FREEZER 048-GM-48303/048-GM-48304/048-GM-48305

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

NEWS 2017 SANIFLO. Pumps and pumping stations

E Specifications. Ver.1.2. Page: EKMC Product Name. Model Number. 3.Dimensions. Approved by. Checked by.

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

FALCON 900B N910JW S/N 31

W+ Pumps. Minimize Life Cycle Costs

LED Flood EX 21. User Manual

Hydrogen Sensor Testing and Certification Underwriters Laboratories Inc.

MODULAR CONNECTOR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION

MAC-120HE-03 Air-Cooled Chiller

2008 FALCON 2000LX Serial Number F2000LX-154 HB-JET

G Specifications. Ver.1.1. Page: EKMC K. 1.Product Name. Model Number. 3.Dimensions. Approved by. Checked by. ,2018 Mar.

ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System

AIRCRAFT SALES & ACQUISITIONS

OWNERS MANUAL OPERATION AND INSTALLATION PROCEDURE AND LIMITATIONS

Transcription:

THERMOCOAX Aeronautic Products : Grey Water Drain Mast Equipped with Electrical Anti-Icing System Thermocoax Pedigree THERMOCOAX is a worldwide key player and has been designing, developing and manufacturing heating solutions for aeronautic market for 20 years. Based on the 60 years homemade Mineral Insulated Cable, we provide our customers with solutions for: Ground applications: R&D programs with institutes Ground aero test equipment Flying models: Anti-icing system for pitot tube, Angle of Attack, Total Air Temperature Sensor Wire Cutter (WSPS) on helicopter equipped with electrical anti-icing devices. Anti-icing screen for helicopter engine air inlet. Specific Application: Shower Heating system for VIP business Jet 1 / 9

Technical Application of Grey water drain mast To save weight, the grey water from the washbasins is ejected to the outside of the plane. Function of the configuration, most planes are equipped with two drain masts, one at the front and one at the rear where the washbasins are. Drains are fixed at the bottom of the fuselage exposed to the outside air. The major risk with a drain mast is the production of ice at the tip and risking a potential impact with the fuselage or it getting sucked into the engines. 2 / 9

Technical Description of Drain Mast Anti-Icing In accordance with the specification, the drain is equipped with one or two water pipes. The shell is made using the resin-moulded method. For optimal efficiency of the anti-icing system, THERMOCOAX technology warms up the water pipes instead of the shell. Heating cable technology available: Self-regulated cable Or fixed power cable coupled with switches Inconel or nickel sheath cable Ø 5 up to 3mm Power supply 28 or 115Vac 400hz Dissipated power from 20 to 250 Watts Pipe Temperature up to >40 C at -55 C environmental conditions Each heating cable is produced with cold ends. The cable is then wrapped onto the tube. 3 / 9

The cable is flexible enough to increase the volume of cable and get more heat for areas exposed to coldest conditions. Cable is brazed on the tube for: Conduction pipe/heater for more thermal efficiency Robustness Reliability Longevity Production repeatability 4 / 9

Thermocoax Drain Mast Final Assembly Drain masts are developed, produced and checked in Thermocoax facilities 5 / 9

Acceptance Test Criteria of Drain Masts: Dimensional Weight Line resistance Insulated resistance under 500Vcc Dielectric 1mn 1500Vac Test for Qualification Program of Drain Mast THERMOCOAX conducts the qualification test program in accordance with our customers' specifications. Our engineers write the QTP for customer approval prior to running the tests. Most of the tests (thermal, humidity, electrical etc.) on the drain mast are performed in THERMOCOAX s test lab facilities. These require heavy equipment (vibration, acceleration, impact etc.) and are sub-contracted to external laboratories or provided by our customers with the complete water system. -Typical Qualification Test Schedule for Drain Mast Vibration Acceleration Impact & Crash Safety Vibration 6 / 9

Pyrotechnic Shock Load Test Temperature & Altitude Temperature Variation Explosive Atmosphere Waterproofing Sun & Dust Fluid Susceptibility Salt Audio, induced signal, radio frequency HIRF, ERFE Lightning Icing Fire and Flammability Combined Temperature, Altitude, Humidity Dielectric Test Corrosion Engine Blade Out X-Ray Examination Thermal Cycling Test Lightning test 7 / 9

THERMOCOAX supplies the following platforms: Dassault Falcon Jet Bombardier C Series Embraer EJet 1 & 2 THERMOCOAX is a key player for anti-icing systems on board aircraft platforms and is proud to participate in challenging international aero programs. THERMOCOAX focuses on high quality heating products for the best stability and repeatability in operation. For 15 years, we have witnessed the challenges faced by our customers to manufacture aircraft and to improve the safety and comfort of passengers. 8 / 9

Powered by TCPDF (www.tcpdf.org) New large programs are taking shape, THERMOCOAX is ready for production ramp up and supporting the market with cost-effective drain masts. 9 / 9