PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Similar documents
Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

2. HEAT EXCHANGERS MESA

MODELING OF THE SINGLE COIL, TWIN FAN AIR-CONDITIONING SYSTEM IN ENERGYPLUS

ABSTRACT. 2 CanmetENERGY

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

Effects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Commercial Refrigeration

Experimental Study Of An Ejector Refrigeration System

Using Evaporative Cooling Methods for Improving Performance of an Air-cooled Condenser

Energy Transfer Based Test Method Development and Evaluation of Horizontal Air Flow Re- Circulatory Air Curtain Efficiencies

Global Journal of Engineering Science and Research Management

Two-Phase Evaporation Pressure Drop Experimental Results for Low Refrigerant Mass Flux

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Numerical study of heat pipe application in heat recovery systems

Heat pump supplemental heating system for motor vehicles

Effect of evaporator temperature on vapor compression refrigeration system

Study on the Effect of Blade Angle on the Performance of a Small Cooling Tower

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Performance of CO2 Cycles with a Two-Stage Compressor

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

TEST REPORT #32. System Soft-Optimized Test of Refrigerant D2Y60 in Air Source Heat Pump

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Investigation of Evaporator Performance with and without Liquid Overfeeding

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

THE EFFECT OF HIGH TEMPERATURE AIR DRYING ON EVAPORATION, RUNNABILITY AND COATED PAPER PROPERTIES. Pertti Heikkilä and Pasi Rajala

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

Chapter 14, Problem 27.

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

Low GWP Refrigerants for Air Conditioning Applications

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

A Statistical Analysis of a Liquid Desiccant Dehumidifier/Regenerator in an Air Conditioning System

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Shortcut Model for Predicting Refrigeration Cycle Performance

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Real Time Upright Freezer Evaporator Performance Under Frosted Conditions

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV)

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

EXPERIMENTAL PERFORMANCE OF AN R410A-FILLED C-SHAPE THERMOSYPHON

ABSTRACT. Professor Reinhard Radermacher, Department of Mechanical Engineering

A study on performance improvement of corrugated type total heat exchanger considering the structure of flow passage on surface

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

CO 2 EVAPORATOR DESIGN

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Heat Recovery Units. Heat Recovery 1

Dynamic performance of a novel dew point air conditioning for the UK buildings

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS. FJ Smit and JP Meyer

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

HFO-1234yf Performance in a Beverage Cooler

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

ABSTRACT APPLICATIONS

Development of Small-diameter Tube Heat Exchanger: Circuit Design and Performance Simulation

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

Experimental Investigation Of A New Low- Approach Evaporator With Reduced Refrigerant Charge

Experimental investigation of the performance of industrial evaporator coils operating under frosting conditions

Influences of temperature of vapour-condenser and pressure in the vacuum chamber on the cooling rate during vacuum cooling

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Effect of magnetic field on the performance of new refrigerant mixtures

A CRYOGENIC TEST STATION FOR SUBCOOLING HELIUM HEAT EXCHANGERS FOR LHC

Modified Air Cooler with Split Cooling Unit

Experimental and Numerical Study on the Performance of R410A Liquid Recirculation Cycles with and without Ejectors

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Design Optimization of Variable Geometry Microchannel Heat Exchangers

Steady and Cyclic Performance Testing of Packaged R-410A Units

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Transcription:

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING M. POIRIER, D. GIGUÈRE, Z. AIDOUN, M. OUZZANE Natural Resources Canada, CANMET Energy Technology Centre-Varennes 1615, Lionel Boulet Blvd, P.O. Box 4800, Varennes (Quebec) J3X 1S6 Canada Tel.: (450) 652-5521, Fax: (450) 652-5177, E-mail: mpoirier@nrcan.gc.ca ABSTRACT A well instrumented experimental set-up for testing heat exchangers in a capacity range of up to 10 kw was built according to ASHRAE standards and has been used to study CO 2 as the coolant in a secondary loop for applications in low temperature display cases for supermarkets. Tests were conducted with a commercial staggered air refrigeration coil. Excellent stability is obtained when operated with CO 2 recirculation. Energy balances on air and on CO 2 correlate within ± 5%. The pressure drop in the coil was measured at different operating conditions. None of the available correlations predicting the pressure drop in coil gave acceptable results, however, the experimental values were fitted using an equation having the form DP = a (x) b (G CO2 ) c with a mean difference of 2.8%. The presented experimental data and empirical correlation can be useful for validating theoretical models. 1. INTRODUCTION The use of carbon dioxide (CO 2 ) as secondary refrigerant for freezing temperature applications in supermarkets is already a reality in Western Europe [1] and is at the demonstration stage in North America. In support to the commercialization of this technology, a well instrumented test bench was built in view to provide experimental data for the validation of a design tool that would predict the operating characteristics such system (capacity, pressure drop, etc ). In this paper will be presented a description of the experimental set-up, the results of some tests and a correlation allowing to predict the pressure drop in the evaporator for a wide range of carbon dioxide flow and outlet quality. 2. EXPERIMENTAL SET-UP AND PROCEDURE The experimental set-up, built according to the ASHRAE standard for forced circulation air cooling and heating coils [2], is showed in Figure 1. The CO 2 loop includes a circulating centrigugal pump, two mass flow and density sensors, a CO 2 /air corrugated fin coil, a CO 2 brazed plate condenser and a CO 2 tank having a volume of eighteen liters. The head of the CO 2 pump is 300 kpa. The loop is also equipped with several temperature (RTD) and pressure sensors. The CO 2 is condensed using a brine loop (potassium formate), allowing good flexibility and control of the condensing temperature and capacity. A CO 2 level sensor is used to monitor the level of CO 2 in the tank.

Figure 1. Simplified scheme of the experimental set-up (CV: electronic valve, FN: fluid density sensor, FT: flow transmitter sensor, LT: level transmitter sensor, PDT: pressure differential sensor, PT: pressure sensor, TE: temperature sensor). The air loop is made of a small room enclosed in a larger room. The air flows from the main room to the small one through the CO 2 evaporator and air returns to the main room through a duct, pull by a centrifugal blower. In the duct, a corrugated fin coil can be used to cool down the air using the cold brine loop and an electric heater can be used to warm the air, increasing the refrigeration charge. The two rooms are equipped with temperature (RTD) and dew point temperature sensors. The evaluation of air flowrate is done using a nozzle at the inlet of the duct, as described in ASME MFC-3M-1989 standard [3]. The pressure drop across the nozzle is measured using a differential pressure sensor. The rooms are well insulated from the outside, minimizing air and moisture infiltration, and consequently very few frost is formed on the evaporator during tests. The room is also equipped with a CO 2 sensor for safety. All tests reported in this paper were conducted with an evaporator made of two commercial refrigeration staggered coil of 0.61 meter wide and 0.32 meter high, for a corresponding face area of 0.1936 m 2. Each coil has four rows of ten tubes per row, and four corrugated fins per inch. The evaporator thus have 80 copper tubes of 3 / 8 " O.D. (i.d. of 8.712 mm) arranged in one circuit, as shown in Figure 2. Tube spacing are 31.75 mm vertically and 27.48 mm horizontally. Fin thickness is 0.254 mm and fin length is 110 mm for each coil of four rows, giving a total fin length of 220 mm, with and empty space of 50 mm between the two coils. The total external heat transfer surface (fins + tubes) is 13.64 m 2 and the internal tube heat transfer surface is 1.34 m 2. Finally, in this evaporator, air and CO 2 are circulating counter-flow.

CO 2 Air Air CO 2 Figure 2. Configuration of the air/co 2 evaporator. The temperature sensors (RTD) were periodically calibrated and the accuracy was always better than 0.05 C. The pressure sensors (PT), differential pressure sensors (PDT) and CO 2 flow sensor were calibrated by the manufacturer and their accuracy were ± 1 kpa, ± 1 Pa and ± 0.1% respectively. The accuracy of the air flow measured using the nozzle was ± 2% [3]. Moreover, the use of several sensors at critical location (e.g. air temperature sensors before and after the evaporator) and the correlation between the saturated pressure and temperature for CO 2 allow to rapidly identify possible inaccurate sensors. A data acquisition system is used to continuously record the value of all sensors and set-points four times per second. Prior to the realization of a test, the room is cooled down using the air/brine coil located in the duct. When the required room temperature is reached, the brine stream to the air/brine coil is stopped and liquid CO 2 is circulated to the CO 2 evaporator. The CO 2 flow is adjusted using the variable frequency drive of the CO 2 pump and the electronic valves (CV). The CO 2 temperature range for this test bench is from -18 C to -35 C, corresponding to pressure in the range of 1200 to 2100 kpa. Stable CO 2 mass flow velocity is obtained in a wide range going from 0.002 kg/s to 0.100 kg/s, however the maximum flow is lower when pressure drop in the evaporator is high. Air velocity is adjusted using the variable frequency drive of the blower and the nozzle diameter; its range is from 0.047 m 3 /s to 1.15 m 3 /s. 3. RESULTS AND DISCUSSION 3.1. Stability and energy balance Figure 3 is showing the air and CO 2 temperatures and the CO 2 flow during a typical test. CO 2 total flow was quite stable at about 0.0275 kg/s and recirculation ratio was around four to one. Air mass flow was 3.13 kg/m 2 s, corresponding to an air velocity of 2.23 m/s. During this test, CO 2 was at saturation conditions at both inlet and outlet of the coil, and the CO 2 temperature was lower at the outlet (-25.6 C) than at the inlet (-24.1 C) because of the CO 2 pressure drop in the evaporator. The air was cooled by about 2.5 C (from around -20.3 C to -22.8 C). An energy balance on the air side gave a capacity of 1.54 kw (at ± 6%).

In some other tests, experimental conditions were ajusted to obtain superheated CO 2 at the exit of the coil. This allowed to compare energy balances on air and on CO 2, and both values were in good agreement, the difference always being lower than ± 5%, which is within the experimental error. Figure 3. Typical results showing the stability of the system. 3.2. Pressure drop in the evaporator The test bench was operated at different conditions over a period of 10 months. During that period, all tests were conducted in the absence of frost on the fins. In Table 1 are presented some of the results of tests identified by the corresponding date and time. These results were taken during periods of stable operation and are average values over a five-minute period (1200 measurements). Typically, the standard deviation for temperature values was 0.045 C. The data reported in Table 1 were used to calculate the mass flow of CO 2 per unit flowing area (G CO2 ). Data in Table 1 also allowed to perform energy balance on air, which led to the evaporator capacity and the CO 2 quality at the outlet of the evaporator. In a recent paper, Ould Didi et al. [4] discussed and compared several models developed to predict the pressure drop (DP) in coil for different refrigerants. Those models were investigated but they all failed to predict the pressure drop observed in the present work (DP values in Table 1). However, it was found that the pressure drop measured in the evaporator can be well represented by a function of both the CO 2 flow (G CO2 ) and the outlet quality (x), having the form: DP = a (x) b (G CO2 ) c (1)

Table 1. Experimental results for several tests. Date Time (T air ) in dt air (T CO2 ) in (T CO2 ) out Flow air Flow CO 2 dp G CO2 Capacity x C C C C kg/s kg/s kpa kg/m 2.s kw November 20, 2004 8h30-17.91 2.42-21.33-23.20 0.592 0.0407 106 683 1.44 0.137 November 19, 2004 5h25-16.58 2.41-20.03-21.73 0.586 0.0397 101 666 1.42 0.138 August 16, 2005 5h03-21.53 2.72-25.47-27.27 0.585 0.0305 90 511 1.60 0.189 December 8, 2004 15h00-20.32 2.52-24.13-25.59 0.600 0.0286 81 480 1.52 0.202 December 10, 2004 7h15-20.32 2.49-24.09-25.50 0.603 0.0275 78 463 1.51 0.199 August 10, 2005 16h26-20.53 2.81-25.21-27.54 0.836 0.0302 119 507 2.36 0.280 August 9, 2005 8h10-20.91 2.67-25.48-27.59 0.850 0.0268 106 450 2.28 0.300 August 16, 2005 14h20-17.56 5.13-25.06-27.67 0.585 0.0304 138 510 3.02 0.352 August 5, 2005 17h10-18.95 3.62-24.77-27.36 0.839 0.0298 133 500 3.05 0.363 December 7, 2004 6h30-20.31 2.43-24.13-24.90 0.606 0.0147 44 247 1.48 0.350 December 10, 2004 15h45-20.25 2.51-24.17-24.94 0.600 0.0145 45 244 1.51 0.362 November 29, 2004 17h10-20.05 3.08-24.78-25.89 0.611 0.0183 61 307 1.89 0.359 December 9, 2004 3h20-20.19 2.52-24.15-24.93 0.606 0.0147 45 248 1.54 0.362 May 12, 2005 8h00-10.08 9.04-24.76-28.87 0.587 0.0442 304 741 5.33 0.434 November 18, 2004 11h45-17.38 2.46-21.21-21.75 0.587 0.0112 34 187 1.45 0.458 May 5, 2005 10h15-12.66 7.83-25.26-28.68 0.598 0.0341 223 573 4.71 0.487 November 29, 2004 14h55-20.04 4.06-26.24-27.62 0.611 0.0173 73 291 2.50 0.494 August 9, 2005 13h05-17.51 4.20-24.58-27.12 0.836 0.0236 131 396 3.54 0.523 November 22, 2004 15h55-20.50 2.57-24.46-25.05 0.593 0.0103 34 173 1.53 0.510 August 10, 2005 1h30-17.39 4.27-24.55-27.09 0.838 0.0232 132 390 3.60 0.542 August 11, 2005 13h03-14.56 5.85-25.43-28.33 0.845 0.0314 224 527 4.97 0.552 August 4, 2005 15h15-15.88 6.39-24.46-27.03 0.592 0.0238 133 399 3.80 0.558 August 11, 2005 16h38-13.72 6.17-25.12-28.03 0.843 0.0303 226 509 5.23 0.601 August 5, 2005 13h02-12.20 6.39-23.49-26.39 0.835 0.0288 207 482 5.37 0.656 November 29, 2004 1h20-19.93 5.09-27.67-29.35 0.603 0.0161 85 270 3.09 0.650 December 9, 2004 15h20-20.03 2.48-24.08-24.54 0.606 0.0076 28 127 1.51 0.688 December 6, 2004 6h00-20.06 2.46-24.10-24.55 0.610 0.0076 28 128 1.51 0.682 August 5, 2005 9h37-9.21 7.62-22.62-25.71 0.825 0.0286 234 480 6.32 0.779 May 6, 2005 14h45-15.67 7.29-26.94-29.62 0.597 0.0188 132 316 4.38 0.792 August 5, 2005 4h10-8.57 9.84-23.02-26.31 0.576 0.0228 175 382 5.70 0.875 August 11, 2005 5h08-7.59 9.01-23.76-27.14 0.825 0.0281 273 472 7.48 0.928

In a first step, the values of DP were plotted as a function of (x) n (G CO2 ) m for different values of n and m. The best correlation was obtained for values of n = 1 and m = 1.981. Thus next step was to assume F = x G CO2 1.981 and to realize a curve fit on the data (see Figure 4), which led to the following equation: DP = 0.0169 F 0.799 (R 2 = 0.998) (2) And replacing F by x G CO2 1.981 gave the final form of a correlation that predicts quite accurately the pressure drop in the evaporator for the test bench: DP = 0.0169 (x) 0.799 (G CO2 ) 1.583 (3) Using this correlation to recalculate the DP for each of the tests of Table 1 showed a mean difference of 2.8% and a maximum difference of 6.1%. The above correlation, as it is, only apply to the coil used in this work. It was validated for a G CO2 range from 125 to 750 kg/m 2 s, for all value of quality. Figure 4. Pressure drop in the evaporator as a function of the CO 2 mass flow and outlet quality. 4. CONCLUSION A well instrumented test bench was built in view to provide experimental data for the validation of a design tool that would predict the operating characteristics of refrigeration systems for applications in low temperature display cases for supermarkets using CO 2 as secondary refrigerant. As a first result, an emperical correlation allowing to predict the pressure drop of CO 2 in the evaporator was obtained from a set of experimental results covering a given range of CO 2 flow and outlet quality. Further tests will be done in view to enlarge the range of operating conditions for which this

correlation is valid. Also, emperical correlations predicting other characteristics such as air and CO 2 outlet temperatures, evaporator capacity and CO 2 heat transfer coefficient will be developed. NOMENCLATURE dp and DP pressure drop (kpa) dt difference of temperature ( C) fn function G CO2 mass flow of CO 2 per unit flowing area (kg/m 2 s) i.d. inside diameter O.D. outside diameter 1.981 Phi and F used in place of x G CO2 R 2 Variance T temperature ( C) x quality of the CO 2 at the outlet of the coil Subscripts in out inlet outlet REFERENCES 1- Sawalha S., 2005, Using CO 2 in Supermarket Refrigeration, ASHRAE Journal, August 2005: 26-30. 2- Methods of Testing Forced Circulation Air Cooling and Heating Coils, ASHRAE Standard 33-2000. 3- ASME MFC-3M-1989, January 31, 1990, Measurement of Fluid Flow in Pipes Using Orifice, Nozzles, and Venturi. 4- Ould Didi M.B., Kattan N., Thome J.R., 2002, Prediction of two-phase pressure gradients of refrigerants in horizontal tubes, Inter. J. of Refrig., 25: 935-947.