DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

Similar documents
ABSTRACT. 2 CanmetENERGY

Owner Municipality Built in 1978 Rebuilt in 2001 Rink and bleachers. Surface area (footprint) 4,140 m 2 (44,700 ft 2 )

RAPB. Multi-Purpose Facility. Characteristics of Hockey Rink. Project profile Refrigeration technological innovation

Trends and Perspectives in Supermarket Refrigeration

July 2012 was a significant date for the HVAC and Refrigeration industry as it saw the introduction of the Carbon Tax and the HFC Levy.

IEA Annex 26: Advanced Supermarket Refrigeration / Heat Recovery Systems Canada Report

CHAPTER 1 INTRODUCTION

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Making equipment decisions

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Campbell Soup Company Extends Use of CO2 Systems Into Their Operations

Commercial Refrigeration

HFCs or the Old Refrigerants - what is the best Choice?

IEA Annex 26: Advanced Supermarket Refrigeration/Heat Recovery Systems

Parilla Thermal Storage Project Case Study. May Page 1 of 11

Hydrocarbon heat and refrigeration supply systems for a mini-hotel with a shop and laundry

Transcritical CO2 Bottle Cooler Development

DeCO2ded: Understanding ROI on CO2 Refrigeration Systems

Refrigerants & Cooling in renovation buildings

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

PHASE-IN of natural refrigerants. Prof. Dr. Armin Hafner NTNU Norway

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

CO2 TRANSCRITICAL BOOSTER SYSTEMS

MAYEKAWA MFG. CO., LTD Botan Koto-ku, Tokyo , JAPAN TEL:(81) FAX:(81)

Ammonia. Background on ammonia as a refrigerant

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

FACT SHEET 9 Large Air-Conditioning (air-to-air)

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

Use of transcritical CO 2 in industrial applications

Guidance for Stationary Refrigeration & Air-Conditioning

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE

An Efficient Cold Store Facility

Low GWP Refrigerants for Air Conditioning Applications

Green economy with natural refrigerants

investment in R&D, the commitment to - name.

Stakeholder Meeting Dublin, Ireland Update on the new F-Gas Rules Andrea Voigt, EPEE

From the Field to the Supermarket

Brazed Plate Heat Exchanger for CO Applications

Reinventing Energy Efficiency WARMNESS.

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

Natural Refrigerants.

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

Environmentally friendly refrigeration systems for industrial use

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

FACT SHEET 9 Large Air-Conditioning (air-to-air)

GEOTHERMAL DESIGN GUIDE

Global Solutions for Ammonia Industrial Refrigeration

Leadership, Innovation, Advanced Technology Synergise Here!

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Alternative Refrigerants Part 1 Future and Current Options. Overview

Chapter 2. Alternatives to HCFCs and their Characteristics

Thermodynamics I. Refrigeration and Heat Pump Cycles

Improving Cold Chain Competitiveness with Danfoss Energy Efficiency Solutions.

Chapter 11 REFRIGERATION CYCLES

A refrigeration system for supermarkets using natural refrigerant CO 2

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

Commercial CO 2 Refrigeration Systems

Chapter 11 REFRIGERATION CYCLES

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Hydrocarbons as refrigerants

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Why Secondary-Coolant Systems for Supermarket Refrigeration?

Winter sports fun all year round, thanks to natural refrigerants

NEW HARRIS TEETER STORE SHOWCASES FIRST HILL PHOENIX SECOND NATURE COMPACT CHILLER UNITS IN NORTH AMERICA

Simply fresh today and tomorrow

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

US Supermarket Modeling Activities

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Meeting the Challenges of the EU HFC Phase-Down

Energy consumption storage facilities examined in ICE-E

Thermodynamics II Chapter 5 Refrigeration

Responsible Care Product Stewardship for Refrigerants

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

DEEPAK PALIWAL, S.P.S.RAJPUT

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

Energy Performance of Low Charge NH3 Systems in Practice. Stefan S. Jensen

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Comparison Ammonia / Secondary Refrigerant System against Direct Evaporation of HCFCs /HFCs

THE INSTITUTE OF REFRIGERATION

FACT SHEET 6 Transport Refrigeration

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

ARE YOU AN AUTHORISED REFRIGERATION GAS PRACTITIONER?

HVAC Water chiller selection and optimisation of operation

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

R&D ON HEAT PUMPS WITH NATURAL WORKING FLUIDS IN JAPAN

Mayekawa Mfg. Co., Ltd. Kuniaki Kawamura

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Transcription:

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA Daniel Giguère, Technology Expert Georgi Pajani, Engineer Sophie Hosatte, Section Head, Buildings CETC-Varennes, Natural Resources Canada, Varennes, Québec, Canada ABSTRACT A demonstration project of innovative refrigeration technologies has been underway in a Loblaws supermarket in Canada with the technical support of the CANMET Energy Technology Centre- Varennes (CETC-Varennes) from Natural Resources Canada. The technology implementation allows the reduction of greenhouse gas emissions by approximately 75% and energy consumption by approximately 25% compared to a typical supermarket. The principal innovation at this 10,000 square-meter (102,000 square-feet) Loblaws is the installation of a secondary-loop refrigeration integrated with the building s heating and ventilation. The objective of the secondary-loop is threefold: to reduce refrigerant charge and therefore leaks, to facilitate heat recovery, and obtain a better quality of cold to limit food spoilage. For instance, heat recovery provides for all heating and hot water demand and allows the elimination of the furnace. The project detail and the performance analysis will be presented. Key Words: Supermarket, refrigeration, secondary-loop, secondary fluids, integrated HVAC&R 1 INTRODUCTION Natural Resources Canada s CANMET Energy Technology Centre Varennes (CETC-Varennes) has established a major program in refrigeration. This program involves research, development, and deployment activities undertaken in partnership with universities, refrigeration stakeholders (manufacturers, suppliers, consultants, end-users), utilities, and energy management federal and provincial organizations. The deployment activities were launched in September 2003 under the Refrigeration Action Program for Buildings (RAPB) funded through the Climate Change Plan for Canada, whose goal is to reduce greenhouse gas (GHG) emissions in Canada in keeping with the Government s commitment under the Kyoto Protocol. The principal goals of the RAPB are to reduce GHG emissions by 1.6 Mt of CO 2 equivalents a year and the energy consumption by 1,700 GWh equivalent per year by 2012, in Canadian supermarkets, skating-ice and curling rinks. The strategy to achieve these goals is based on the development of constructive partnerships, information and capacity building activities and demonstration projects. In the supermarket sector, the first demonstration project has been carried out with Loblaw, a major chain of supermarkets in Canada. The project aimed at reducing the energy consumption as well as greenhouse gas (GHG) emissions, while improving product quality and customer comfort, through the implementation of an innovative refrigeration integrated to the heating, ventilation and air conditioning (HVAC) equipment and advanced control strategies. The project has enabled Loblaw to build an environmentally friendly supermarket, the first of its kind in Canada. 1

2 BACKGROUND Supermarkets are the most energy intensive buildings in the commercial sector in Canada, with an energy consumption of approximately 1,000 kwh per square meter per year. This is due to the fact that although supermarkets are heated, ventilated and air-conditioned like any other building, they also have refrigeration s to keep food products cold or frozen and refrigeration accounts for about half of the buildings total energy consumption. Moreover, the refrigeration s of most supermarkets use large quantities of synthetic refrigerant (roughly 1,000 to 2,000 kg of HCFC or HFC per store), which circulates under pressure, from the mechanical room to the refrigerated display cases, through kilometers of piping with hundreds of brazed joints. This is a source of significant leakage, which accounts for 10 to 30 % of the total refrigerant charge per year. Although the HFC refrigerants currently used to replace CFC and HCFC are harmless to the ozone layer, they are nevertheless powerful GHGs that are 1500 to 3000 times more damaging than CO 2. Refrigerant losses from supermarkets therefore have a significant impact on global warming. The refrigeration in a supermarket is generally designed as an isolated process intended to produce cold and most of the heat extracted from refrigerated display cases is released into the environment. Nevertheless the amount of heat rejected is much larger than the energy needs of the store and could meet its heating and hot water requirements most of the time, even in the coldest winter days. Another drawback of most of the Canadian supermarket refrigeration s is that the heat is released at temperatures above 40 o C. This temperature level is normal for the hot weather in the southern United States but could be much lower in the cold Canadian climate, leading to a significant reduction in the energy consumption. 3 DEMONSTRATION PROJECT CETC-Varennes and Provigo/Loblaws cooperated closely on this demonstration project to implement the following strategies at Repentigny: Refrigeration and synthetic refrigerants confined to the mechanical room; Secondary fluids on cold and heat rejection loops of both low and medium temperature refrigeration s; Package refrigeration units confined in the mechanical room insuring minimal refrigerant charge and leaks; Semi-hermetic compressors; Plate-type evaporators and plate-type condensers; Only four thermal expansion valves located in the mechanical room; No evaporator pressure regulator required to operate the refrigeration ; Heat recovery from the condenser with a secondary loop to provide almost all the space heating demand; Variable condensing temperature by the modulation of the secondary loop heat rejection temperature according to the outside temperature in order to minimize the overall supermarket energy consumption while meeting the refrigeration and space heating loads of the supermarket; No furnace for space heating. 2

3.1 Refrigeration System Cold Side The nominal capacity of the low temperature refrigeration is 200 kw, and 400 kw for the medium temperature. Both refrigeration s use R507A, a HFC refrigerant blend. As shown in Figure 1, two secondary fluids that have no environmental impact potassium formate for low temperatures (around -28 o C) and propylene glycol for moderate temperatures (around 6 o C), are cooled by the refrigerant through a heat exchanger. These fluids circulate through pipes from the mechanical room to the refrigerated display cases at low pressure, thus reducing the possibility of leaks. Subcooling of the low temperature liquid line by 30ºC corresponding to 55 kw of cooling at design conditions is performed by the medium temperature through a plate-type evaporator. The desuperheat of the low temperature unit is recovered with a double wall heat exchanger. The defrosting of the display case evaporators is performed by a small flow of warm glycol circulating in a three-pipe. Fig. 1. Cold side of the low and medium temperature refrigeration s 3.2 Refrigeration System Hot side Heat Recovery and Upgrade for Heating Purposes The heat rejection loops of the low and medium temperature refrigeration s are independent. The use of ethylene glycol as secondary fluid, on those loops, makes it easier to recover the heat from the condenser and the superheat energy from the compressor, to meet the air heating and the hot water needs of the building. 3

The heat load (up to 220kW) rejected by the low temperature is recovered and upgraded by seven water loop heat pump units. This strategy leads to a lower heat rejection temperature and therefore improves the energy efficiency of the main refrigeration. The heat load (up to 250kW) rejected by the medium temperature loop is recovered by an air coil located in a rooftop unit. The cold fresh supply air and the space return air are mixed at the heat recovery coil. The secondary fluid temperature is varied strategically in order to match the space heating demand. Therefore the refrigeration of the medium temperature loop acts as a heat pump. Fig. 2. Hot side of the low and medium temperature refrigeration 4 HEAT RECOVERY OF LOW AND MEDIUM TEMPERATURE REFRIGERATION SYSTEM 4.1 Operation and Control Strategies The operation of the HVAC&R integrated is optimized by the control in order to take advantage of the Canadian climate. The main control variable is the condensing temperature and its optimization is based on two criteria: building heat load (recovery) and outside temperature. 4

5 EXPECTED IMPACTS The integrated secondary-loop HVAC&R (Figures 2 and 3) allows a reduction of approximately 80 % in the amount of synthetic refrigerant compared to a conventional supermarket. The project is expected to reduce total supermarket energy consumption by 18 % and GHG emissions by about 75 % relative to conventional supermarkets of equivalent size. The GHG emission reduction comes from both energy savings and synthetic refrigerant leak decrease. It is equivalent to the total GHG emissions of 430 family-size cars per year. The has also other benefits: ease of operation and maintenance, more stable food temperatures (resulting in improved product quality and longer shelf life time) and added comfort for the customers. 6 RESULTS AND PERFORMANCE The 10,000 square-metre (102,000 square-foot) Loblaws supermarket in Repentigny opened on April 28, 2004, and the integrated HVAC&R has been operating successfully since then. The HVAC&R operator indicated that the start-up of the whole has been an easy task. A detailed monitoring of the integrated is performed on a continuous basis with more than two hundred sensors scanned each minute. CETC-Varennes has been analyzing the performance for at least a complete year. 6.1 Winter Conditions The following tables show the performance under winter conditions for a 24-hour operation on December 20, 2004. The average outdoor temperature was -22.6ºC, the indoor temperature 20.9 ºC, and the indoor relative humidity 15%. Table 1. Refrigeration and heating energy consumption - December 20, 2004 Units Low temp Medium temp Total Compressor consumption kwh 1 570 1 536 3 106 Outdoor Fluid cooler kwh 0 0 0 Pump cold side kwh 168 127 295 Pump condenser kwh 122 533 655 Heat pump consumption kwh 775 0 775 Heat recovery coil pump kwh 0 65 65 Auxiliary heating kwh 322 0 322 Total consumption kwh 2 957 2 261 5 218 The low temperature compressor unit worked at 85% of its nominal capacity and the medium temperature unit at 55 %. The energy consumption for space heating was reduced by 88%, thanks to the heat recovered from the refrigeration. Even at 26 C outdoor temperature, only 3% of the heating load was supplied by the auxiliary heating unit (for the shipping/receiving dock). The total energy consumption (5218 kwh) is the sum of the energy consumed by the refrigeration compressors, heat pumps (including fans), circulation pumps, and auxiliary heating units. 5

Table 2. Space heating and refrigeration load - December 20, 2004 Units Low temp Medium temp Total Total Space Heating Load kwh 3 366 5 973 9 339 Total Refrigeration Load kwh 3 449 5 176 8 625 Total load kwh 6 815 11 149 17 964 We have defined a specific COP for the supermarket (COP supermarket ). COP supermarket = Total space heating and refrigeration load. Total energy consumption for heating and refrigeration Table 3. Saved energy and COP improvement - December 20, 2004 Units Low temp Medium temp Total Saved space heating energy kwh 2 269 5 908 8 177 Supermarket COP 2.3 4.9 3.4 Supermarket COP DX without heat recovery 1.4 1.5 1.5 COP supermarket is a good indicator of the efficiency of the supermarket, in order to compare different technologies and strategies. The calculated COP for this supermarket is more than 2.4 times the COP of a similar supermarket using a multiplex DX and a furnace for space heating (this factor varies with the outdoor temperature). 6.2 Summer Conditions Under summer conditions the secondary fluid refrigeration consumes 10% more than a standard multiplex because of the extra pumping power. The saturated evaporating temperature is lower by 3 C for the low temperature unit but almost the same for the medium temperature unit. The saturated condenser temperature for the secondary-loop is typically 1 C higher than the temperature in a standard DX. In the Montreal area the temperature exceeds 18 C for only 1500 hours per year, and therefore this small increase in energy consumption under summer conditions (which corresponds to less than 5% of the total supermarket energy consumption in a year) is significantly overshadowed by the heating season benefits. It is possible to increase the energy performance during summer conditions by working on the pumping power required for circulating the secondary fluids. The pumps in place were probably oversized. 7 CONCLUSION The preliminary results obtained up to now show that this demonstration project of advanced integrated HVAC&R s in the Repentigny Loblaws supermarket is successful. These results demonstrate that: 1) the use of secondary loops on the cold and hot sides of a refrigeration are promising alternatives to direct expansion s, in order to reduce synthetic refrigerant charges and leaks in supermarkets; 2) the use of a secondary loop on the hot side of the refrigeration offers a better potential and flexibility for heat recovery and upgrade; 3) it is possible to match the whole heating (heating and hot water) requirements of supermarkets by recovering the heat rejected by the refrigeration 6

(even during the coldest days of the Canadian winter) and therefore to eliminate the use of auxiliary heating devices such as furnaces. The detailed monitoring of the supermarket performance is going to continue until summer 2005. The final project report will present also a detailed financial evaluation of the project, investments, and operation costs, as well as a qualitative evaluation of customer comfort and produce shelf life. This demonstration project is a huge step towards the increase of the energy and environmental performance of Canadian supermarkets. Other demonstration projects, featuring new operating strategies and secondary loops have already been planned under the Refrigeration Action Plan for Buildings. In the long term, the use of secondary loops will facilitate the adoption of natural refrigerants (ammonia, carbon dioxide, hydrocarbons...) in supermarkets. Finally, it is interesting to note that the substantial environmental benefits to be achieved through this new approach to the design of refrigeration s should not imply in any additional costs, since the energy savings will offset the extra investment costs within an acceptable time frame. 8 ACKNOWLEDGEMENTS The authors would like to thank Provigo/Loblaw for their confidence and support in this project, as well as all the technical and financial partners: Hill-Phoenix, Hussmann, Keeprite, Consolidated Energy Solutions, MicroThermo, Hydro-Québec, l Agence de l efficacité énergétique du Québec, and the Office of Energy Efficiency and the TEAM program (Technology Early Action Measures) at Natural Resources Canada. 7