UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS

Similar documents
ICC CODE CORNER 2015 International Fire Code

Fire Test Requirements for Upholstered Furniture Used in Public Buildings

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

Fire and Explosion lnvestigation and Litigation Support

Report on Public Input June 2014 NFPA 101

UNDERSTANDING THE CHANGES TO CALIFORNIA TB ON FLAME RETARDANCE OF RESILIENT FILLING MATERIALS USED IN UPHOLSTERED FURNITURE

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

First Revision No. 6-NFPA [ Section No. 2.2 ]

FM Approval Standard For Cavity Walls And Rainscreens

Report on First Revision June 2014 NFPA 101

TECHNICAL BULLETIN Weston Parkway, Cary, North Carolina, Telephone (919) FLAMMABILITY TESTING: A REVIEW BY COTTON INCORPORATED

January 14, Via Electronic Mail to NFPA

State of California Department of Consumer Affairs Green Science Policy Workshop for Manufacturers and Retailers

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

NFPA 101 Life Safety Code Culture change 2012

Artificial Trees and Fire Performance

Illuminating Label Laws 2015 Manufacturing Summit Franklin Furniture Institute Mississippi State University

CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

Upholstered Furniture Main Task Group Conference Call Meeting Agenda March 18, 2016

EC EP 14 All other electrical K-920 equipment in patient care vicinity NFPA , Chapter 10

Schools and the Fire Code A Partnership for Safety

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Safety Code Users. Fire Tests for Life SUPPLEMENT 3. Marcelo M. Hirschler FIRE PROPERTIES

CMS Announcement 3/27/2017. Adoption of 2012 Life Safety Code Health Care Facilities Code. Kenneth Daily, LNHA

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Chapter 43, Building Rehabilitation allows for degrees of compliance based on the work category such as the extent of work.

Global flammability standards.

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

CLT Adhesive Tests in Support of Mass Timber Buildings

UL Conference Atlanta May 21 22, 2014 Polyurethane Foam Association presentation

Fire Test Methods ASTM NFPA UL ISO IEC

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Public Comment No. 1-NFPA [ Section No ]

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

NFPA Technical Committee on Fire Tests FALL 2010 ROC MEETING MINUTES April 15-16, 2010 Southwest Research Institute San Antonio, TX

FHCA 2014 Annual Conference & Trade Show

Considerations in the Design of Smoke Management Systems for Atriums

First Revision No. 7-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

Agency for Health Care Administration

CEC CODE COMPLIANCE SEMINAR FOR ICC CHAPTER 8 INTERIOR FINISHES & DECORATIVE MATERIALS

ICC CODE CORNER 2012 IFC Code & Commentary

Report on First Revisions with Statement June 2014 NFPA 101

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

Building Description Applicable Codes & Standards Prescriptive Requirements. Performance Based Design

Considerations for Development of Effective Flammability Standards

Title: BFST1505 Syllabus

Agency for Health Care Administration

Fire Performance of Furnishings As Measured in the NBS Furniture Calorimeter.

For additional information regarding Group I occupancies please call (951)

FIRE SAFETY SURVEY REPORT AMBULATORY SURGICAL CENTERS (ASC) & END STAGE RENAL DISEASE (ESRD) MEDICARE

REVISION RECORD FOR THE STATE OF CALIFORNIA ERRATA

Chapter 34 Flammable and Combustible Liquids

Evaluation on Combustion Characteristics of Finishing Materials for Exterior Walls

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

INSPECTOR I SKILLS ADMINISTRATION

Chapter 2: Definitions

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor

Agency for Health Care Administration

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

Wausau Fire Department Inspection Violation Code Listing (Modified) All Applicable Records

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

The Cannabis Industry: Fire Department Requirements

Potential Impact of New UL Fire Test Criteria

Copy of article submitted to Fire Safety Engineering for publication January/February 2009

Agency for Health Care Administration

DEALING WITH FIRE SAFETY

Single Room Occupancy Hotel Safety & Stabilization Task Force

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Resolution: FR-1-NFPA Statement: When tests are conducted for fire reconstruction or research the items excluded above can be included.

Prepublication New Text Jan 2018 Changes to Environment of Care and Life Safety Chapters

NFPA Technical Committee on Fire Tests FALL 2011 ROC MEETING MINUTES

Questions related to specific materials, methods, and services will be addressed at the conclusion of the presentation.

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Compliance w/ the 2012 Life Safety Code

ORDINANCE NO

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

HOME FIRES THAT BEGAN WITH UPHOLSTERED FURNITURE

Fire Prevention Plan for McGrath Health and Wellness Center 1714 Cleneay Avenue

Are there any policies regarding outlets that contain USB ports?

New Facilities. Minimum Requirements

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

Tampa, FL Fire Cause Classification Task Group Tue, 14 April 2011

Kicking Toxics Out of the Work Place: Eliminating the Use of Unnecessary Flame Retardant Chemicals

Academic and Administrative Buildings

January 1, 2014 Mandatory Effective Date

American Fire Sprinkler Association. An Introduction to the IBC and IFC

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

Tunnel Fire Dynamics and Evacuation Simulations

7.1 Smoke Detector Performance

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

AHC Meeting #7 July 12-13, Occupancy WG Report

Agency for Health Care Administration

Transcription:

Page 20 ABOUT CODE CORNER CCFS would like to remind you to check with your local Authority Having Jurisdiction (AHJ) for questions and opinions concerning your local Fire and Building Codes. The information contained in this article is supplied as a courtesy by the International Code Council (ICC) and is based on the International Fire and Building Codes and their respective commentaries. Your local codes or ordinances may vary. While the criteria of Section 805 specifically applies to I-1 residential board and care facilities, it is offered as background on the thoughts, rational and various test methodology for regulating upholstered furniture and mattresses. Discussion of applicability of flammability standards for certain campus facilities is an issue being deliberated the CCFS Codes and Standards Committee. If you have thoughts or opinion, please share them with the committee at: codescommittee@campusfiresafety.org SECTION 805 UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS 805.1 Group I-1, board and care facilities. The requirements in Sections 805.1.1 through 805.1.2 shall apply to board and care facilities classified in Group I-1. Furnishings and contents are a subject that codes have not addressed very strongly in the past. Ultimately, the fire hazard potential within a building depends heavily upon what is in the building and where it is placed. First, the burning characteristics of the materials will vary and the location of the material will change the characteristics of a fire. For instance, a couch within a small compartment will create a much different fire event than the same couch burning in a large open atrium (see Figure 805.1). The compartment may be limited by the amount of oxygen available, while the atrium fire will be limited only by the amount of combustibles to burn because oxygen will be plentiful; therefore, the compartment is likely to reach flashover while the atrium will not. Generally, upholstered furniture and mattresses are the largest fire hazards in most residential buildings because a mattress or an upholstered chair or sofa are the only products typically present where people live that can cause room flashover on their own. Board and care facilities house, in a supervised setting, more than 16 persons on a 24-hour basis because of age, mental disability or other reasons. These occupants are also considered more vulnerable than the general population and have had a history of starting fires in beds or upholstered furniture. There is also more of a concern than with a Group I-2 occupancy over occupants having the ability to purposely start a fire. This is less likely in an assisted living setting but more likely in a halfway house setting; therefore, limitations on combustibility of upholstered furniture and mattresses are also required. Reducing ignitability and combustibility will significantly reduce the level of fire hazard. The requirements are slightly different than for Group I-2 occupancies in that different tests and performance criteria are required because of the nature of the hazards.

Page 21 805.1.1 Upholstered furniture. Newly introduced upholstered furniture shall meet the requirements of Sections 805.1.1.1 and 805.1.1.2. This section informs the user that two aspects of upholstered furniture are regulated: the ignitability by cigarettes and the maximum allowable heat release in accordance with ASTM E 1537. 805.1.1.1 Ignition by cigarettes. Newly introduced upholstered furniture shall be shown to resist ignition by cigarettes as determined by tests conducted in accordance with NFPA 260 and shall meet the requirements of Class I. This section focuses on the ignitability of furniture when exposed to lighted cigarettes. The test required by this section is NFPA260. NFPA260 uses an overall classification system that looks at the cigarette ignition behavior of the individual components that may be found in upholstered furniture. Section 805.1.1.1 requires a Class I rating for upholstered furniture, meaning that no evidence of ignition occurred and specific limitations on char length must be met based on each specific component of the furniture. For example, the cover fabric would be allowed a 1.77-inch (45 mm) char length, whereas the interior fabric would be allowed only a 1.5-inch (38 mm) char length to be considered Class I. The other components of upholstered furniture tested using NFPA 260 include the welt cords, filling/padding, decking material and barrier materials. This section differs from Section 805.2.1.1 for Group I-2 nursing homes and hospitals and Section 805.3.1.1 for Groups I-3 detention and correction facilities in that it only references NFPA 260 as a compliance method.

Page 22 Groups I-2 and I-3 are also allowed to comply with NFPA 261, which specifically looks at ignitability of a mock-up of upholstered furniture. NFPA 261 simply presents a method for study of the ignitability of the furniture mockup and a technique to measure the char length, and limits the maximum char length to 1.5 inches (38.1 mm). As with Sections 805.2.1.1 and 805.3.1.1, when the room or space is sprinklered in accordance with NFPA 13, this test is not required. The code requires new facilities of this occupancy classification to be sprinklered except that sprinkler systems in accordance with NFPA 13R and 13D are allowed. 805.1.1.2 Heat release rate. Newly introduced upholstered furniture shall have limited rates of heat release when tested in accordance with ASTM E 1537 or California Technical Bulletin 133, as follows: 1. The peak rate of heat release for the single upholstered furniture item shall not exceed 80 kw. 2. The total energy released by the single upholstered furniture item during the first 10 minutes of the test shall not exceed 25 megajoules (MJ). The two tests specified in this section measure the overall combustibility of the furniture. When a building is sprinklered in accordance with NFPA13, this section does not apply. Upholstered furniture must be tested to either ASTM E 1537 or California Technical Bulletin 133 (which are basically the same test, but ASTM E 1537 has no pass/fail criteria). This test uses a full-scale calorimeter, with the furniture item either in a standard room or under a hood. A full-scale calorimeter allows a representative piece of furniture to be burned and the products of combustion to be collected and analyzed in the exhaust duct by measuring gases (principally oxygen) in order to measure heat release. The test also measures weight loss during the test [see Figure 805.1.1.2(1) for a representation of the test]. The acceptance criteria set by the code are as follows: Peak heat release is limited to 80 kw, and Total energy (or heat) release within the first 10 minutes cannot exceed 25 mega joules (MJ). Limitations are placed on the maximum intensity and fire effluents produced by restricting the peak heat release rate and the amount of combustibles actually burned. The total energy release of 25 MJ could be translated to a steady fire as follows, where: X = Steady fire heat release rate expressed in kw: X 10 minutes = 25 MJ (10 minutes = 600 sec and 25 MJ = 25,000 kj) X 600 sec = 25,000 kj X = 25,000 kj/ 600 sec = 41.66 kj/sec X = 41.66 kj/sec = 41.66 kw ~ 42 kw heat release rate A steady fire of 42 kw (133 kj/sec) for 10 minutes will result in a total energy release of 25 MJ. Because fires in more realistic conditions do not burn steadily and vary in their characteristics, the criterion is given in the form of a peak heat release rate and total energy release. To provide a better understanding, if the were burning at the maximum peak heat release rate of 80 kw for the first 10 minutes, the total energy output would be 75 MJ, [ 80 kw(kj/sec) H 10 minutes (600 sec) = 48,000 kj = 48 MJ], which is well over the criterion of 25 MJ. A fire burning at a steady rate from start to finish is not realistic because fires must go through an initial growth stage before a peak heat release rate will be reached, followed by a decay phase; therefore, because a realistic fire will not burn at the peak heat release rate from the start of the fire, it is possible for a piece of furniture to

Page 23 have a peak heat release rate of 80 kw and still stay within the 25 MJ limitation. Figure 805.1.1.2(2) demonstrates the difference between a steady fire and a more realistic unsteady fire. As stated in the exceptions, the heat release rates will not apply to buildings sprinklered in accordance with NFPA 13. Sections 805.2.1.2 and 805.3.1.2 address the heat release rate limitations for upholstered furniture in the same manner. It should be noted that Section 805.3.1.2 does not reference California Technical Bulletin 133. 805.1.1.3 Identification. Upholstered furniture shall bear the label of an approved agency, confirming compliance with the requirements of Sections 805.1.1.1 and 805.1.1.2. In order to achieve verifiable compliance, labeling by an approved agency is required. Otherwise this information would be extremely difficult to verify in the field. See the commentary for the definition of Labeled in Section 202. 805.1.2 Mattresses. Newly introduced mattresses shall meet the requirements of Sections 805.1.2.1 through 805.1.2.3. Sections 805.1.2.1 and 805.1.2.2 deal with the combustibility of mattresses. Section 805.1.2.1 focuses on initial ignition and the ability of a mattress to sustain a fire; Section 805.1.2.2 is focused primarily on the burning characteristics of mattresses. 805.1.2.1 Ignition by cigarettes. Newly introduced mattresses shall be shown to resist ignition by cigarettes as determined by tests conducted in accordance with DOC 16 CFR Part 1632 and shall have a char length not exceeding 2 inches (51 mm). Exception: Mattresses in rooms or spaces protected by an approved automatic sprinkler system installed in accordance with Section 903.3.1.1. This section sets a maximum char length of 2 inches (51 mm) when the mattress is tested under DOC 16 CFR, Part 1632. This test is actually a mandatory regulation for all mattresses sold within the United States. More specifically, it is part of the regulations governed by the Consumer Products Safety Commission (CPSC) under the Department of Commerce (DOC). Sections 805.2.2.1 and 805.3.2.1 have the same reference and requirements for Groups I-2 and I-3 occupancies. Thus, mattresses that fail to meet the 16 CFR 1632 test will be those that were sold before the CPSC regulation went into effect (in 1972) or that were sold outside of the United States. 805.1.2.2 Heat release rate. Newly introduced mattresses shall have limited rates of heat release when tested in accordance with ASTM E 1590 or California Technical Bulletin 129, as follows:

Page 24 1. The peak rate of heat release for the single upholstered furniture item shall not exceed 100 kw. Exception: Mattresses in rooms or spaces protected by an approved automatic sprinkler system installed in accordance with Section 903.3.1.1. 2. The total energy released by the single upholstered furniture item during the first 10 minutes of the test shall not exceed 25 MJ. Exception: Mattresses in rooms or spaces protected by an approved automatic sprinkler system installed in accordance with Section 903.3.1.1. As noted, an occupant smoking in bed and initiating a mattress fire is a major fire hazard in board and care facilities. This section, like Section 805.1.1.2, limits combustibility through a limitation of the peak heat release rate and on the total energy output in the first 10 minutes of burning. These limitations vary slightly from those for upholstered furniture. Each mattress is allowed a maximum heat release rate of 100 kw, whereas each upholstered furniture item is limited to 80 kw. The total energy (or heat) release limitation is the same as for upholstered furniture items, which is 25 MJ in the first 10 minutes. As with upholstered furniture, these restrictions are not applicable in buildings sprinklered in accordance with NFPA 13. The tests that determine the peak heat release rate and total energy (or heat) release are specific to mattresses. These tests are detailed in ASTM E 1590 and California Technical Bulletin 129 (which are the same test, except that ASTM E 1590 does not have pass/fail criteria). These tests, like that referenced in Section 805.1.1.2, make use of a full scale calorimeter to measure the products of combustion. There are two differences between ASTM E 1537 and ASTM E 1590: (a) the object being tested (see commentary, Section 805.1.1.2) and (b) the ignition source. Both tests use a gas burner, but they are different in geometry, gas flow rate, duration of gas flow and position of flame application. Section 805.2.2.2 contains the same restrictions and testing requirements on combustibility for mattresses in Group I-2 nursing homes and hospitals and Section 805.3.2.2 for Group I-3 detention and correction facilities. 805.1.2.3 Identification. Mattresses shall bear the label of an approved agency, confirming compliance with the requirements of Sections 805.2.2.1 and 805.2.2.2.