2G & 3G GSM Door Contact Alarm

Similar documents
2G & 3G GSM Portable PIR Alarm

2G & 3G GSM Wireless Beam Alarm


GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

GSM 3G AUTO DIALLER PLUS

GSM PROTECT ANTI-THEFT ALARM WITH GPS TRACKING & MOBILE PHONE ALERTS

GSM PERIMETER & INTRUDER ALARM

Kwêbeam GSM/Interface/Repeater Module

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

D3D Wi-Fi GSM Smart Alarm System -User Manual

GSM RFID VOICE Alarm System

GSM WIRELESS ALARM SYSTEM Model: GSM-0308W

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

MOBILE CALL GSM Alarm System User s Manual

Wireless Alarm system s manual

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

DYGIZONE GJD910 Lighting Controller & Enunciator

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

UK MADE GSM SOLUTIONS

Security GSM Alarm System

System. For a better understanding of this product, please read this user manual thoroughly before using it.

IP & SMS Alarm Communicator

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Intelligent Wireless GSM Alarm System

Mobeye CM2410 GSM fire alarm communicator

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

1. User features of the GSM dialer

GSM Emergency Alarm. User s Manual. For a better understanding of this porduct,please read this user manual thoroughly before using it.

SMART HOME SECURITY. Dual Network Communicating Alarm System with RFID INVINCIBLE. Instruction Manual. Customer Helpline

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

SMS GSM Alarm Messenger

S3 Sim Secual Alarm system with GSM transmitter

WiFi GSM APP Smart Home Security System

Dual-Network LCD Keyboard Intelligent Alarm

EM8710 GSM Alarm System Starter Kit

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

1. Introduction. 2. Product overview

It is necessary to match all peripherals with the EVOLVEO Alarmex main unit before the first use. For safety reasons, they are not factory paired.

Summit 3208GLD USER MANUAL. Electronics Line

Ontech GSM 9040/50. Reference Manual English -1 -

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

GSM Alarm System. S120 User Manual. Ver 1.00 Date Issued:

User Manual (LS-GSM-006)

HomeSecure HS-BASIC-V2 Installation Manual: Table of Contents

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

X64 Wireless Training

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

SA 2650 Kit User Manual

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

Elderly Care Alarm System

SMART SWITCH TECHNOLOGIES. SmartSwitch Yacht-Guard Model SMS-8 Vessel System Monitor Installation Manual

TRX MAINS CONNECTION DIAGRAM

EZY SWITCH. SMS-IRR-4 System Monitor Installation Manual

DIY Home Security Support 30 numbers wireless sensors

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

GSM House Alarm System. User Manual. Ver 1.20 Date Issued:

SC-F3G User Manual 1.0

status AW1 Plus WiFi Alarm System User Manual

1. Functions of GPS locator ETLOC-30S 3

your silent and loyal servant

GSM-SD WITH CALL,SMS,MMS MANUAL

Version 1.03 January-2002 USER S MANUAL

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use

Contents. Glossary

My Visonic SMS App User Guide

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

PART NO: TSMS. Designed in Australia by. Instruction Manual. Factory Car Alarm Upgrade Providing Alarm Notification Via SMS Messaging N517

User Manual & Setting Instructions

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

PERMACONN PM1030 Includes DI300. Installation Manual

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

FarmGuard External Wireless Security

BURGLAR ALARM PANEL BS-468

The complete wirefree security alarm solution

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

Gmini 100. User Guide INTELEC SYSTEMS Intelligent Electronic Systems. Web:

S4 Combo Secual / S4 Combo Vid Secual GSM and Landline Alarm System


PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

INSTALLATION AND USER MANUAL SG2. GSM+WiFi. Alarm Security System

Contents. Contents

Wireless D.I.Y. Alarm Kit

Memcom Emergency Telephone

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

GSM CAR ALARM SYSTEM USER S MANUAL

GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual

Vcare. User Manual. Ver WiFi - GSM- App. Smart Home Security System

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

GSM LCD Touch Keypad Wireless Intelligent Alarm System. User s manual

HELPY QUICK-TL GSM INTL

USER MANUAL QSDL503AD Intelligent Auto-Dial Alarm System

MT-S20 USER S MANUAL. (Motor Alarm &Tracker) (Version 1.4)

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

2000 Series. Program Entry Guide. Control Panels

Transcription:

2G & 3G GSM Door Contact Alarm www.gsm-activate.co.uk MODEL RF - PIR PAGE 1

Product Information Our 2G/3G GSM Door Contact Alarm is a standalone alarm system for smaller rooms inside properties. It will alert you using GSM technology by sending you a text message and/or phone call to your mobile phone or landline when the sensor has been broken alerting you to a possible intrusion. The unit is enclosed in a IP65 rated box which means it is perfectly weathered for outside installation and has passed testing in high temperature as well as below freezing temperatures. GSM Module Specification GSM Frequesncy: Quadband freq 850/900/1800/1900/ 3G Model 2100Mhz Power Supply Voltage: 9-24 volts DC - 1 Amp Min Current used in standby mode: 60mA Max IP 65 Enclosure rating for outside installation Micro 2G or 3G Simcard No landline required Dimensions - L100 x W68 x H50mm Dimensions PCB Only - L95 x W67mm Sim Active Function Operating Temperature: -10 +40 C Programmed by text message Text to test signal strength PIR Specification Alert Distance : 25-35mm seperation Detection: Dual function, magnetic door and emergency switch Battery Life : 6 Months Dimensions - L60xW32xH13mm Wireless Range - 20 Meters Page 2

Instructions Slide the simcard into the holder making sure that the clipped corner of the simcard lines up with the clipped corner of the simcard holder as seen in the picture above. IMPORTANT - PLEASE READ PLEASE MAKE SURE YOU DISCONNECT THE POWER WHEN YOU FIT THE SIM CARD THEN PLACE THE SIM CARD IN WITH THE CLIPPED CORNER FACING UPWARDS. PLEASE SEE PICTURE ABOVE. Signal Strength To help make sure that you place the unit in a suitable position you can text the unit to see how much signal strength the detector is receiving by texting the command #SIGNAL# The detector will perform a test on the signal strength. You will receive a text confirming the signal strength between 0 up to 30. We strongly recommend that you place the unit where it can receive a signal of at least 10. You will find that with a score of less than 10 the unit will be unreliable. Page 3

How to Programme Mobile Numbers After inserting the simcard into the GSM module, turn the unit on and wait until you see the GREEN LED is on. This indicates that the module has a signal and the unit is ready for use. Please Note - To avoid confusion we have colour coded the hash (#) and the equals (=) symbols. Example: (hash) (1,2 or 3) (equals) (phone number) (hash) To programme mobile numbers into the unit you will need to send a text with the contact numbers (maximum 3 numbers) Example #1=07123456789# Then send this as a text to the simcard in the unit (with your preferred mobile number) #2=07123456789# Then send this as a text to the simcard in the unit (with your preferred mobile number for second contact) #3=07123456789# Then send this as a text to the simcard in the unit (with your preferred mobile number for third contact) If you wish to cancel a number, follow this example Example: (HASH) (1,2 or 3) (EQUALS) (DELETE) (HASH) #1=DELETE# Then send this as a text to the simcard number of your unit. PLEASE NOTE Please send one message at a time and wait for the GSM detector to send you back the text acknowledgement NUMBER STORED before you try to add the next number. Below is a notepad to help you remember the numbers that you have saved to your unit in the event you need to modify or delete in the future. #1= # #2= # #3= # Page 4

How to programme the SMS text message You can now change the alarm message from input detected to one of your own choice. To change the message send the text command as follows #MESS=YOUR MESSAGE# The detector will reply with a text message - MESSAGE STORED PLEASE NOTE You can only use a maximum of 19 characters including spaces for your customised message. Telephone Call Alerts The Door Contact Alarm can be programmed to send you a telephone call after each text alarm has been sent. You will receive approximately three ring tones. The unit will then hang up automatically. This is to prevent call charges being incurred. To text call alerts to ON please send the text message #CALL=ON# The unit will reply back with the message - CALL ON To disarm call alerts please send the text message. #CALL=OFF# If the call function has been set to ON you will receive a text message and shortly after a phone call. Page 5

How to use the 2G/3G Door Contact Alarm Once you have positioned the door contact, the system is now ready to use. The GSM Door Contact Alarm has two modes, Alarm Mode and Auto Mode. In alarm mode, you have to arm your alarm manually when required. In auto mode, the alarm is always armed. You should choose the mode most suitable to your application. Your can select the mode you require by sending the text message to the unit as follows: #Mode=1# #Mode=2# Alarm Mode (default) Auto Mode Mode 1 - Alarm Mode: #mode=1# Alarm mode is the default mode. You will need to set the alarm to ON before it detects movement and sends an alarm message. To set the alarm to ON you will need to send the text message #ALARM=ON# #ALARM=OFF# This will activate the alarm. This will deactivate the alarm It is important to remember that when the alarm has been triggered you will need to reset the alarm by sending the text message #ALARM=ON# each time. Mode 2 - Auto Mode: #mode=2# The alarm is always armed and will trigger when movement is detected. The alarm will automatically reset back into armed mode after 20 seconds when no movement is detected. (Dipswitch 2= OFF) ref page 3 How to use the relay output The 3G Auto Dialler has a 2 amp relay output which can be used to switch on external electric devices such as lighting, sirens etc By texting the unit you can turn the relay ON or OFF, Below are examples on how to do this. #REL=ON# #REL=OFF# This will turn the relay output ON This will turn the relay output OFF After each operation the unit will reply with a status report REL ON/OFF (Dipswitch 2 = ON) ref page 3 The relay can also be setup to pulse for 20 seconds when the inputs have been triggered. To activate this mode you need to set DIPSWITCH 2 ON - ref page 3 This can be used to trigger a siren or reset other equipment. Page 6

To connect wireless door sensors you will need to go through a process so that the devices are matched to the receiver on the dialler. 1. Hold down the pairing button on the RF Module for 3 seconds (refer to figure 1) 2. Trigger the door switch Pairing the Wireless Door Sensors 3. The RF module has a RED LED which will flash when pairing in complete. Figure 1 PAGE 7

Quick Reference FACTORY RESET To set the unit back to factory settings you will need to send a text message #RESET# Please Note - doing this will reset ALL of your parameters. Only send a reset command when necessary. The GREEN ready LED will flash eight times. Dipswitch Settings Dipswitch 1 = ON = 3G Selected OFF = 2G Selected Dipswitch 2 = ON = Pulse Relay (20 seconds) OFF = Pulse Relay Off For more technical support please browse the FAQ s on our website www.gsmactivate.co.uk Alternatively email our technical support team at technical@gsm-activate.co.uk and we will do our best to respond to your querry within 24 hours Monday- Friday. 09/072018 AD Page 9