D System Description D System indoor handsfree video handset with analogue LD LED backlit display. omplete door entry functions with alarms management. International standard SOS pushbutton and keyboard for intercom function and programming device. Direct call to switchboard function. ring tones selectable for different call types. Surge protection. Wall mount installation. Technical data LD display resolution: 0 x Power supply : 0 Vdc Stand by absorption: 0 ma @ 0 V Max. operating absorption: ma @ 0 V Operating temperature: (-0)-(+0) Front view 0 * # 0 Dimensional data Legend, Dimensions in mm 0 * # 0. Loudspeaker. SOS key. Monitor key. Information LED. Switchboard call key. ommunication LED. Answer key. Unlock key. Shortcut key 0. olor control knob. Brightness knob. Ring volume control knob. Microphone. Numerical keys and corresponding numbers. Defense area LED to. LD Display BT00-b-EN 0/0/0
0 * # Rear view 0 Legenda. Anti removal switch connector. Master and Slave selection pin. onfigurators housing. RJ system BUS connector. SOS alarm connector. Small entrance panel (00) connector. Alarm sensors connector (see specific page). Door lock interface (0) connector. Alarm sensor anti-removal connector 0. Serial interface connector onfigurazione Indoor handset must be configured for following parameters: F F I I #I #I FF : Floor number II : Apartment number #II : Maximum apartments quantity per floor in a riser Two different configuration modes available for whole system : configuration MODE and configuration MODE. The main characteristics for each configuration mode are listed below. When the biggest number of #FF in whole system is 0, and the biggest number of #II is, and the total risers number is 0, we recommend to choose (MODE ) configuration for system. POSITION Mode Mode F FF FF F I II II I #I Default for #II is 0, II #I need not connect the configurator (#II setup using same value for all system handsets). When the biggest number of #FF in whole system is more than 0, or the biggest number of #II is more than, we suggest to use (MODE ) configuration to setup #FF (choose the biggest number #FF of system) and #II (choose the biggest number #II of system), then calculate total IU number of system. If the total number (#FF * #II * R ) is less or equal 000, use of (MODE ) is suggested. BT00-b-EN 0/0/0
Two different device configuration ways available: WAY ) onfiguration settings by device keyboard WAY ) onfiguration settings by inserting phisical configurators onfiguration settings by device keyboard - WAY : SETUP operation code and light status installation settings operation list TABLE next meaning and information for the operation operation remark Set room number for handset Set maximum apartments quantity per floor in a riser Set external SOS to be always on or always off Enable and disable function of monitoring Small EP Return all the parameters to default value Enable and disable sensors Set and type of sensors # alarm lights and message light off # alarm lights and message light off # message light will indicate status of this setting item # message light will indicate status of this setting item # message light will indicate status of this setting item # Message light is off. alarm lights will indicate status of each alarm zone # alarm lights will indicate status of each alarm zone. FFII# correct parameter input: long tone wrong parameter input: short tones Default room number: 0 * return to main menu of installation setup, short tone unsuccessful operation: short tone II# or I# correct parameter input: long tone Range:- Default:; it can be set only when there is no setting for hardware wrong parameter input: short tones * return to main menu of installation setup, short tone unsuccessful operation: short tones SOS external switch or pushbutton always open (): message light on, long tone 0 SOS external switch or pushbutton always close (): message light off, long tone * return to main menu of installation setup, short tone unsuccessful operation: short tones Default: always open enable: handset can monitor Small EP: message light on, long tone Default: cannot monitor Small EP. This 0 Shielded: handset can not monitor Small EP: message light off, long tone function is available only when the * return to main menu of installation setting, short tone function is set as Small EP function. unsuccessful operation: short tones Get all the default parameters: message light on, long tone 0 Do not get all the default parameters: message light off, long tone * return to main menu of installation setup, short tone unsuccessful operation: short tones # alarm zone with sensor: LED on, a long tone. Default: (all) without sensor 0 alarm zone without sensor: LED off, a long tone. * return to previous menu, short tone Ineffective operation: short tones # alarm zone with sensor: LED on, a long tone. 0 alarm zone without sensor: LED off, a long tone. * return to previous menu, short tone unsuccessful operation: short tones * return to main menu of installation setting, short tone unsuccessful operation: short tones # always open () sensor for alarm area : LED on, long tone Default: sensors for alarm zones are 0 always close () sensor for alarm area : LED off, long tone always open (). * return to previous menu, short tone unsuccessful operation: short tones # always open () sensor for alarm area : LED on, long tone 0 always close () sensor for alarm area : LED off, long tone * return to previous menu, short tone unsuccessful operation: short tones * return to main menu of installation setup, short tone unsuccessful operation: short tones BT00-b-EN 0/0/0
onfiguration SETUP operation code and light status installation settings operation list TABLE next meaning and information for the operation operation remark Set infrared sensor # Message light is off. alarm lights will indicate status of infrared sensor. Setting: infrared sensor: light of this alarm zone will be on. Non-infrared sensor, light of this alarm defence area zone will be off. # infrared sensor for alarm zone : LED on, long tone 0 non- infrared sensor for alarm zone : LED on, long tone * return to previous menu, short tone unsuccessful operation: short tones Note: /// alarm zone are # infrared sensor for alarm zone : LED on, long tone defined as infrared alarm zones, door alarm, smoke alarm, gas 0 Non- infrared sensor for alarm zone : LED on, long tone alarm. They cannot be changed. * return to previous menu, short tone / are defaulted as infrared unsuccessful operation: short tones alarm zones s. / alarm are defaulted as non-infrared alarm zones Setting for Time delay after alarm set Setting for Time delay after alarm happens Enable and disable sound alarm for thief ) Doorbell function setup(if is doorbell function, it is not Small EP function) ) Handset connection to Apartment interface function setup # The light of the zone indicates the parameter For example, if the parameter is, then LED will on # The light of defence area give the parameter. For example, if the parameter is, then LED will on * return to main menu of installation setup, short tone unsuccessful operation: short tones delay 0 s: long tone, only LED will on Default: 00 s delay 00 s: long tone, only LED will on only for thief area alarm delay 0 s: long tone, only LED will on delay 0 s: long tone, only LED will on delay s: long tone, only LED will on * return to main menu of installation setup, short tone Other unsuccessful operation: short tones delay 0 s: long tone, only LED will on Default: 0 s delay 00 s: long tone, only LED will on only for thief area alarm delay 0 s: long tone, only LED will on delay 0 s: long tone, only LED will on delay s: long tone, only LED will on * return to main menu of installation setup, short tone unsuccessful operation: short tones # enabled: if there is a burglar alarm, loudspeaker will emit a sound. Message light on, long tone The Information LED indicates the setup state disabled: if there is a burglar alarm, loudspeaker will not emit a sound. 0 Message light off, long tone. * return to main menu of installation setup, short tone unsuccessful operation: short tones * exit main menu of installation setup, short tone unsuccessful operation: short tones # The information LED to give setup state # The information LED to give setup state Default: no sound Enable doorbell function, the information LED is on, long tone. Default: is not doorbell function, 0 Disable doorbell function, the information LED is off, long tone tt is Small EP function. * return to main menu of installation setup, short tone unsuccessful operation: short tones handset has connected to the Apartment interface the information LED is on, long tone, 0 handset has not connected to the Apartment interface, the information LED is off, long tone. * return to main menu of installation setup, short tone unsuccessful operation: short tones Default: Handset not connected to the Apartment interface. BT00-b-EN 0/0/0
onfiguration settings by inserting phisical configurators - WAY : Physical connection for their sockets: F F I I #I #I Example (A): The number of handsets is 0, each floor has handsets, the system configuration mode is Mode, the handset configuration should be as follows Example (B): The number of handsets is 0, each floor has handsets. System configuration mode is used. The handset configuration should be as follows: Position configuration value RemarkS F F I 0 It is ok not to insert configurator 0 I #I #I Because the default value of #II is, no configurator is needed Position value RemarkS F F I 0 It is ok not to insert configurator 0 I #I 0 It is ok not to insert configurator 0 #I BT00-b-EN 0/0/0
Wiring diagram - alarm sensors connections + V F F F F F F F F sensor sensor sensor sensor gas sensor smoke sensor door sensor 0 K infrared sensor 0 K V TE: 0 KΩ resistors used to detect cable by cut or cable short circuited to. Resistors must be placed near the sensor. IU can afford sensor Vdc - 00 ma type. onnection way for and contacts mode - SINGLE SENSOR mode - SINGLE SENSOR 0 K 0 K 0 K 0 K mode - MULTIPLE SENSORS N0 mode - MULTIPLE SENSORS 0 K 0 K 0 K 0 K BT00-b-EN 0/0/0
onnection way for and contacts PIN ALARM AREA SENSOR TYPE SENSOR TYPE REMARK F SENSOR INFRARED SENSOR Theft alarm F SENSOR DOOR SENSOR F SENSOR SMOKE SENSOR FIRE alarm F SENSOR GAS SENSOR F SENSOR F SENSOR F SENSOR F SENSOR + V Theft alarm Default is infrared sensor; Default is non-infrared sensor; Default is infrared sensor; Default is non-infrared sensor; an use short key to sensor active or idle an t use short key to let sensor idle an use short key to sensor active or idle BT00-b-EN 0/0/0