SUBMITTAL DATA: SLZ-KA09NA & SUZ-KA09NA 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS. Cooling 4. Heating

Similar documents
SUBMITTAL DATA: SLZ-KA09NA... 9,000 BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS

M-SERIES SUBMITTAL DATA: SEZ-KD15NA4** & SUZ-KA15NA. Job Name: Location: Date: Submitted to: For Reference Approval Construction

SUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11

SUBMITTAL DATA: MSY-GL12NA & MUY-GL12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

SUBMITTAL DATA: MSY-GL24NA & MUY-GL24NA 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

Submitted to: For Reference Approval Construction

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7

SUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A36NKA7

SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A24NHA7

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

INVERTER-driven. Split-ductless and ducted Comfort Systems M Series Full Line Catalog.

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

M-SERIES PRODUCT CATALOG

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

Ductless Split Systems Ceiling Cassette Heat Pumps

The Hyper-Heat Advantage

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To


Ductless Split Systems Wall-mounted, Single Zone Heat Pump

M-Series RESIDENTIAL AND SELECT COMMERCIAL. MS MSY MSZ MXZ

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

Samsung 360 Cassette, Single Zone, Split System

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Ductless Split Systems Concealed Duct Heat Pumps

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

Residential and Light Commercial Ductless Systems Catalog

ZONED COMFORT SOLUTIONS

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

THE WORLD S MOST EFFICIENT HEAT PUMP

HEAT PUMPS. Efficient Comfort For Every Season

DUCTLESS FULL LINE CATALOG

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Heating & Cooling Products

Air Conditioning & Heating. Ductless Product Catalog

A single answer for multiple zones.

CARRIER DUCTLESS & VRF SYSTEMS. What s Next in Comfort

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Redefining Comfort. Mr. Slim Splitductless

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Ductless Systems. Right product for the right application

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

A single answer for multiple zones.

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

IT'S HARD TO STOP A TRANE

BENEFITS. Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase

Kühl J Series DUCTLESS ROOM AIR CONDITIONERS THE EXPERTS IN ROOM AIR CONDITIONING. Wall-mounted Ceiling Cassette The Insider Concealed Ducted

Ceiling type. Contents MMC-AP 1H2UL MMC-AP0181H2UL MMC-AP0361H2UL MMC-AP0421H2UL

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Ductless Split Systems Wall-mounted, Multizone Heat Pump

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

TECHNICAL & SERVICE MANUAL. Ceiling Cassettes

Carrier. Ductless Systems. Taking Comfort, And Your Business, Further. The Right Solution. Right Now.

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

LV Series. SEER 15+ Concealed Built in Heat Pump

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

Variable Refrigerant Flow (VRF), Multi-Zone, Heat Pump & Heat Recovery Systems

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

DUCTLESS SPLIT SYSTEMS

Multi - Zone Systems. Specification and Performance. 208V-230V 18k-36k. Presents

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

LV Series. SEER 20+ Wall Mount Heat Pump

DESIGN & TECHNICAL MANUAL

R4H4. Product Specifications

PHD3. Product Specifications

Geniuses at work. Residential Mini Splits

Transcription:

M-SERIES SUBMITTAL DATA: SLZ-KA09NA & SUZ-KA09NA 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS Job Name: System Reference: Date: ENERGY STAR...Yes ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. : SLZ-KA09NA : SUZ-KA09NA GENERAL FEATURES Four-way 'x' ceiling-cassette indoor unit for ceiling recessed applications Built-in drain mechanism for condensate removal; lifts to 9-/6" Wide air-flow pattern for better air distribution Design features ventilation air intake knockout Long-life air filter included with indoor unit Indoor unit powered from outdoor unit using A-Control Choice of fan speed: Low, Medium, High Automatic restart following a power outage Limited warranty: five years parts and seven years compressors ACCESSORIES Condensate Pump (BlueDiamond X87-7/7; 5/0V) Condensate Pump (Sauermann SI0-5/0; 5/0V) (SLP-5AAUW; required - shipped with unit) Three-pole Disconnect Switch (TAZ-MS0) Air Outlet Guide (MAC-889SG) Mounting Base (DSD-400P) Mounting Pad (ULTRILITE) Wall Mounting Bracket (QSWB000M-) Controller Options Wireless Controller (MHK) Wired Remote Controller (PAR-MAA-J) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-US444CN-) Hand-held Wireless Remote Controller (PAR-FLMA; req.par-fama-e) Wireless Signal Receiver Module PAR-FAMA (for PAR-FLMA-E) SPECIFICATIONS Cooling Rated Capacity....8,400 Btu/h to Capacity Range...,00-0,900 Btu/h SEER...5.0 Btu/h/W EER...0 Btu/h/W Total Input....700 W Heating at 47 F Rated Capacity....0,900 Btu/h to Capacity Range...,00-4,00 Btu/h HSPF...9.6 Btu/h/W COP...44 Total Input....90 W Heating at 7 F Rated Capacity....6,00 Btu/h Rated Total Input...740 W COP...46 Capacity **...6,00 Btu/h Total Input...,040 W Cooling Indoor: 80º F (7º C) DB / 67º F (9º C) WB * Cooling Outdoor: 95º F (5º C) DB / 75º F (4º C) WB * Heating at 47º F Indoor: 70º F (º C) DB / 60º F (6º C) WB * Heating at 47º F Outdoor: 47º F (8º C) DB / 4º F (6º C) WB * Heating at 7º F Indoor: 70º F (º C) DB / 60º F (6º C) WB * Heating at 7º F Outdoor: 7º F (-8º C) DB / 5º F (-9º C) WB * * Rating Conditions per AHRI Standard ** Capacity is at full speed and performance for INVERTER-driven System. Electrical Requirements Power Supply... 08 / 0V, -Phase, 60 Hz Recommended Fuse/Breaker Size....5 A Voltage Indoor - Outdoor S-S...AC 08 / 0V Indoor - Outdoor S-S...DC ±4V OPERATING CONDITIONS Cooling 4 Heating Indoor Intake Air 90 F ( C) DB 7 F ( C) WB 67 F (9 C) DB 57 F (4 C) WB 80 F (7 C) DB 67 F (9 C) WB 70 F ( C) DB 60 F (6 C) WB Outdoor Intake Air 5 F (46 C) DB 4 F (-0 C) DB 75 F (4 C) DB 65 F (8 C) WB -4 F (-0 C) DB -5 F (- C) WB 5 4 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 5 System cuts out at -9º F (-7º C) to avoid thermistor error and automatically restarts at -4º F (-0º C). MCA... A Fan Motor Output...5 W Fan Motor (ECM)...0. F.L.A. Airflow (Lo - Med - Hi).... 80-0 - 50 Dry CFM 50-90 - 0 Wet CFM Air Filter...Polypropylene Honeycomb Sound Pressure Level (Lo - Med - Hi)...9 - - 8 db(a) DIMENSIONS UNIT GRILLE W -7/6 / 570 5-5/8 / 650 D -7/6 / 570 5-5/8 / 650 H 9-/4 / 5 /6 / 0 Weight (Unit/) Lbs...... 6 / 7 kg....6.5 / External Finish (Unit/)... Galvanized-steel Sheets / Munsell 6.4Y 8.9 / 0.4 Field Drainpipe Size O.D.....-/4" / mm Compressor...DC Inverter-driven MCA... A MOCP....5 A Fan Motor (ECM)...0.50 F.L.A. Sound Pressure Level Cooling...46 db(a) Heating...50 db(a) DIMENSIONS W -/ / 800 D -/4 / 85 H -5/8 / 550 Weight...66 lbs. / 0 kg External Finish... Munsell No. Y 7.8 /. Type...R40A Pipe Size O.D. Gas Side.../8" / 9.5 mm Liquid Side..../4" / 6.5 mm Max. Pipe Length.... 65' / 9 m Max. Pipe Height Difference... 40' / m Connection Method...Flared 06 Mitsubishi Electric US, Inc.

DIMENSIONS: SLZ-KA09NA Unit : inch (mm) 9/~-5/(5~7) 9/~-5/(5~7) Ceiling hole -/6~4-/(576~60) Fresh air intake 6-7/(40) 0-7/8(50) -7/6(570) -/6(5) -7/() -7/6(570) Detail drawing of fresh air intake -5/6( 00) - /8(.8) Burring hole 0 4-/(8) (5) -7/8( 7.4) Cut out hole 0 -/4(57) -7/(56) 7-7/(99) -7/(5) -/6(5) 9/~-5/(5~7) -/6~4-/(576~60) Ceiling hole 9/~-5/(5~7) -7/6(87) -9/(66) 4-/4() -/(9) pipe (gas) pipe (liquid) -/~-9/(8~58) Suspension bolt lower edge /(7) 7-5/6(0) Terminal block 9-/6(0) Drain pipe VP-5 connection (O.D. -/4( )) Suspension bolt M0 or W/8 7-9/(9) 8-/6(08) 9-/4(5) +/6 +5 0 (7 0 ) 5/(0) -/6 Wiring entry 7-5/(8) -7/8(48) 5-9/(650) -7/(0) -5/(55) -/8(5) 5-9/(650) -7/(0) Brand label Drain hole Auto vane 4-7/(77) Models SLZ-KA09NA SLZ-KANA SLZ-KA5NA (liquid) /4 inch ( 6.5mm) /4 inch ( 6.5mm) /4 inch ( 6.5mm) (gas) /8 inch ( 9.5mm) /8 inch ( 9.5mm) / inch (.7mm) 4-7/(77) -/8(5) -5/(55) Air intake grille Vane motor 06 Mitsubishi Electric US, Inc.

DIMENSIONS: SUZ-KA09NA 40 Satellite Boulevard. Suwanee, GA 004 Toll Free: 800-4-48 www.mehvac.com FORM# SLZ-KA09NA - SUZ-KA09NA - 0604 06 Mitsubishi Electric US, Inc.

M-SERIES SUBMITTAL DATA: SLZ-KANA & SUZ-KANA,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS Job Name: System Reference: Date: ENERGY STAR...Yes ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Electrical Requirements Power Supply... 08 / 0V, -Phase, 60 Hz Recommended Fuse/Breaker Size....5 A Voltage Indoor - Outdoor S-S...AC 08 / 0V Indoor - Outdoor S-S...DC ±4V : SLZ-KANA : SUZ-KANA GENERAL FEATURES Four-way 'x' ceiling-cassette indoor unit for ceiling recessed applications Built-in drain mechanism for condensate removal; lifts to 9-/6" Wide air-flow pattern for better air distribution Design features ventilation air intake knockout Long-life air filter included with indoor unit Indoor unit powered from outdoor unit using A-Control Choice of fan speed: Low, Medium, High Automatic restart following a power outage Limited warranty: five years parts and seven years compressors ACCESSORIES Condensate Pump (BlueDiamond X87-7/7; 5/0V) Condensate Pump (Sauermann SI0-5/0; 5/0V) (SLP-5AAUW; required - shipped with unit) Three-pole Disconnect Switch (TAZ-MS0) Air Outlet Guide (MAC-889SG) Mounting Base (DSD-400P) Mounting Pad (ULTRILITE) Wall Mounting Bracket (QSWB000M-) Controller Options Wireless Controller (MHK) Wired Remote Controller (PAR-MAA-J) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-US444CN-) Hand-held Wireless Remote Controller (PAR-FLMA; req.par-fama-e) Wireless Signal Receiver Module PAR-FAMA (for PAR-FLMA-E) SPECIFICATIONS Cooling Rated Capacity....,00 Btu/h to Capacity Range...,400 -,00 Btu/h SEER...5.4 Btu/h/W EER...0 Btu/h/W Total Input....90 W Heating at 47 F Rated Capacity....,600 Btu/h to Capacity Range...,00-7,00 Btu/h HSPF...9.6 Btu/h/W COP...8 Total Input....,80 W Heating at 7 F Rated Capacity....8,00 Btu/h Rated Total Input...90 W COP...6 Capacity **...8,00 Btu/h Total Input...,0 W Cooling Indoor: 80º F (7º C) DB / 67º F (9º C) WB * Cooling Outdoor: 95º F (5º C) DB / 75º F (4º C) WB * Heating at 47º F Indoor: 70º F (º C) DB / 60º F (6º C) WB * Heating at 47º F Outdoor: 47º F (8º C) DB / 4º F (6º C) WB * Heating at 7º F Indoor: 70º F (º C) DB / 60º F (6º C) WB * Heating at 7º F Outdoor: 7º F (-8º C) DB / 5º F (-9º C) WB * * Rating Conditions per AHRI Standard ** Capacity is at full speed and performance for INVERTER-driven System. OPERATING CONDITIONS Cooling 4 Heating Indoor Intake Air 90 F ( C) DB 7 F ( C) WB 67 F (9 C) DB 57 F (4 C) WB 80 F (7 C) DB 67 F (9 C) WB 70 F ( C) DB 60 F (6 C) WB Outdoor Intake Air 5 F (46 C) DB 4 F (-0 C) DB 75 F (4 C) DB 65 F (8 C) WB -4 F (-0 C) DB -5 F (- C) WB 5 4 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 5 System cuts out at -9º F (-7º C) to avoid thermistor error and automatically restarts at -4º F (-0º C). MCA... A Fan Motor Output...0 W Fan Motor (ECM)...0.8 F.L.A. Airflow (Lo - Med - Hi).... 80-0 - 90 Dry CFM 50-90 - 50 Wet CFM Air Filter...Polypropylene Honeycomb Sound Pressure Level (Lo - Med - Hi)...0-4 - 9 db(a) DIMENSIONS UNIT GRILLE W -7/6 / 570 5-5/8 / 650 D -7/6 / 570 5-5/8 / 650 H 9-/4 / 5 /6 / 0 Weight (Unit/) Lbs...... 6 / 7 kg....6.5 / External Finish (Unit/)... Galvanized-steel Sheets / Munsell 6.4Y 8.9 / 0.4 Field Drainpipe Size O.D.....-/4" / mm Compressor...DC Inverter-driven MCA... A MOCP....5 A Fan Motor (ECM)...0.50 F.L.A. Sound Pressure Level Cooling...49 db(a) Heating...5 db(a) DIMENSIONS W -/ / 800 D -/4 / 85 H -5/8 / 550 Weight...77 lbs. / 5 kg External Finish... Munsell No. Y 7.8 /. Type...R40A Pipe Size O.D. Gas Side.../8" / 9.5 mm Liquid Side..../4" / 6.5 mm Max. Pipe Length.... 65' / 9 m Max. Pipe Height Difference... 40' / m Connection Method...Flared 06 Mitsubishi Electric US, Inc.

DIMENSIONS: SLZ-KANA Unit : inch (mm) 9/~-5/(5~7) 9/~-5/(5~7) Ceiling hole -/6~4-/(576~60) Fresh air intake 6-7/(40) 0-7/8(50) -7/6(570) -/6(5) -7/() -7/6(570) Detail drawing of fresh air intake -5/6( 00) - /8(.8) Burring hole 0 4-/(8) (5) -7/8( 7.4) Cut out hole 0 -/4(57) -7/(56) 7-7/(99) -7/(5) -/6(5) 9/~-5/(5~7) -/6~4-/(576~60) Ceiling hole 9/~-5/(5~7) -7/6(87) -9/(66) 4-/4() -/(9) pipe (gas) pipe (liquid) -/~-9/(8~58) Suspension bolt lower edge /(7) 7-5/6(0) Terminal block 9-/6(0) Drain pipe VP-5 connection (O.D. -/4( )) Suspension bolt M0 or W/8 7-9/(9) 8-/6(08) 9-/4(5) +/6 +5 0 (7 0 ) 5/(0) -/6 Wiring entry 7-5/(8) -7/8(48) 5-9/(650) -7/(0) -5/(55) -/8(5) 5-9/(650) -7/(0) Brand label Drain hole Auto vane 4-7/(77) Models SLZ-KA09NA SLZ-KANA SLZ-KA5NA (liquid) /4 inch ( 6.5mm) /4 inch ( 6.5mm) /4 inch ( 6.5mm) (gas) /8 inch ( 9.5mm) /8 inch ( 9.5mm) / inch (.7mm) 4-7/(77) -/8(5) -5/(55) Air intake grille Vane motor 06 Mitsubishi Electric US, Inc.

DIMENSIONS: SUZ-KANA 40 Satellite Boulevard. Suwanee, GA 004 Toll Free: 800-4-48 www.mehvac.com FORM# SLZ-KANA - SUZ-KANA - 0604 06 Mitsubishi Electric US, Inc.

M-SERIES SUBMITTAL DATA: SLZ-KA5NA & SUZ-KA5NA 5,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS Job Name: System Reference: Date: Electrical Requirements Power Supply... 08 / 0V, -Phase, 60 Hz Recommended Fuse/Breaker Size....5 A Voltage Indoor - Outdoor S-S...AC 08 / 0V Indoor - Outdoor S-S...DC ±4V : SLZ-KA5NA : SUZ-KA5NA GENERAL FEATURES Four-way 'x' ceiling-cassette indoor unit for ceiling recessed applications Built-in drain mechanism for condensate removal; lifts to 9-/6" Wide air-flow pattern for better air distribution Design features ventilation air intake knockout Long-life air filter included with indoor unit Indoor unit powered from outdoor unit using A-Control Choice of fan speed: Low, Medium, High Automatic restart following a power outage Limited warranty: five years parts and seven years compressors ACCESSORIES Condensate Pump (BlueDiamond X87-7/7; 5/0V) Condensate Pump (Sauermann SI0-5/0; 5/0V) (SLP-5AAUW; required - shipped with unit) Three-pole Disconnect Switch (TAZ-MS0) Air Outlet Guide (MAC-889SG) Mounting Base (DSD-400P) Mounting Pad (ULTRILITE) Wall Mounting Bracket (QSWB000M-) Controller Options Wireless Controller (MHK) Wired Remote Controller (PAR-MAA-J) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-US444CN-) Hand-held Wireless Remote Controller (PAR-FLMA; req.par-fama-e) Wireless Signal Receiver Module PAR-FAMA (for PAR-FLMA-E) SPECIFICATIONS Cooling Rated Capacity....5,000 Btu/h to Capacity Range...,800-7,700 Btu/h SEER...6.0 Btu/h/W EER...0. Btu/h/W Total Input....,460 W Heating at 47 F Rated Capacity....8,000 Btu/h to Capacity Range...,00 -,00 Btu/h HSPF...9.6 Btu/h/W COP...7 Total Input....,950 W Heating at 7 F Rated Capacity....0,00 Btu/h Rated Total Input...,0 W COP...99 Capacity **...,000 Btu/h Total Input...,970 W Cooling Indoor: 80º F (7º C) DB / 67º F (9º C) WB * Cooling Outdoor: 95º F (5º C) DB / 75º F (4º C) WB * Heating at 47º F Indoor: 70º F (º C) DB / 60º F (6º C) WB * Heating at 47º F Outdoor: 47º F (8º C) DB / 4º F (6º C) WB * Heating at 7º F Indoor: 70º F (º C) DB / 60º F (6º C) WB * Heating at 7º F Outdoor: 7º F (-8º C) DB / 5º F (-9º C) WB * * Rating Conditions per AHRI Standard ** Capacity is at full speed and performance for INVERTER-driven System. OPERATING CONDITIONS Cooling 4 Heating Indoor Intake Air 90 F ( C) DB 7 F ( C) WB 67 F (9 C) DB 57 F (4 C) WB 80 F (7 C) DB 67 F (9 C) WB 70 F ( C) DB 60 F (6 C) WB Outdoor Intake Air 5 F (46 C) DB 4 F (-0 C) DB 75 F (4 C) DB 65 F (8 C) WB -4 F (-0 C) DB -5 F (- C) WB 5 4 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 5 System cuts out at -9º F (-7º C) to avoid thermistor error and automatically restarts at -4º F (-0º C). MCA... A Fan Motor Output...0 W Fan Motor (ECM)...0.8 F.L.A. Airflow (Lo - Med - Hi).... 80-0 - 90 Dry CFM 50-90 - 50 Wet CFM Air Filter...Polypropylene Honeycomb Sound Pressure Level (Lo - Med - Hi)... - 5-40 db(a) DIMENSIONS UNIT GRILLE W -7/6 / 570 5-5/8 / 650 D -7/6 / 570 5-5/8 / 650 H 9-/4 / 5 /6 / 0 Weight (Unit/) Lbs...... 6 / 7 kg....6.5 / External Finish (Unit/)... Galvanized-steel Sheets / Munsell 6.4Y 8.9 / 0.4 Field Drainpipe Size O.D.....-/4" / mm Compressor...DC Inverter-driven Twin Rotary MCA... A MOCP....5 A Fan Motor (ECM)...0.50 F.L.A. Sound Pressure Level Cooling...49 db(a) Heating...5 db(a) DIMENSIONS W -/ / 800 D -/4 / 85 H -5/8 / 550 Weight...80 lbs. / 6 kg External Finish... Munsell No. Y 7.8 /. Type...R40A Pipe Size O.D. Gas Side.../" /.7 mm Liquid Side..../4" / 6.5 mm Max. Pipe Length.... 65' / 9.8 m Max. Pipe Height Difference... 40' /. m Connection Method...Flared 06 Mitsubishi Electric US, Inc.

DIMENSIONS: SLZ-KA5NA Unit : inch (mm) 9/~-5/(5~7) 9/~-5/(5~7) Ceiling hole -/6~4-/(576~60) Fresh air intake 6-7/(40) 0-7/8(50) -7/6(570) -/6(5) -7/() -7/6(570) Detail drawing of fresh air intake -5/6( 00) - /8(.8) Burring hole 0 4-/(8) (5) -7/8( 7.4) Cut out hole 0 -/4(57) -7/(56) 7-7/(99) -7/(5) -/6(5) 9/~-5/(5~7) -/6~4-/(576~60) Ceiling hole 9/~-5/(5~7) -7/6(87) -9/(66) 4-/4() -/(9) pipe (gas) pipe (liquid) -/~-9/(8~58) Suspension bolt lower edge /(7) 7-5/6(0) Terminal block 9-/6(0) Drain pipe VP-5 connection (O.D. -/4( )) Suspension bolt M0 or W/8 7-9/(9) 8-/6(08) 9-/4(5) +/6 +5 0 (7 0 ) 5/(0) -/6 Wiring entry 7-5/(8) -7/8(48) 5-9/(650) -7/(0) -5/(55) -/8(5) 5-9/(650) -7/(0) Brand label Drain hole Auto vane 4-7/(77) Models SLZ-KA09NA SLZ-KANA SLZ-KA5NA (liquid) /4 inch ( 6.5mm) /4 inch ( 6.5mm) /4 inch ( 6.5mm) (gas) /8 inch ( 9.5mm) /8 inch ( 9.5mm) / inch (.7mm) 4-7/(77) -/8(5) -5/(55) Air intake grille Vane motor 06 Mitsubishi Electric US, Inc.

DIMENSIONS: SUZ-KA5NA 40 Satellite Boulevard. Suwanee, GA 004 Toll Free: 800-4-48 www.mehvac.com FORM# SLZ-KA5NA - SUZ-KA5NA - 0604 06 Mitsubishi Electric US, Inc.