M-SERIES SUBMITTAL DATA: SLZ-KA09NA & SUZ-KA09NA 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS Job Name: System Reference: Date: ENERGY STAR...Yes ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. : SLZ-KA09NA : SUZ-KA09NA GENERAL FEATURES Four-way 'x' ceiling-cassette indoor unit for ceiling recessed applications Built-in drain mechanism for condensate removal; lifts to 9-/6" Wide air-flow pattern for better air distribution Design features ventilation air intake knockout Long-life air filter included with indoor unit Indoor unit powered from outdoor unit using A-Control Choice of fan speed: Low, Medium, High Automatic restart following a power outage Limited warranty: five years parts and seven years compressors ACCESSORIES Condensate Pump (BlueDiamond X87-7/7; 5/0V) Condensate Pump (Sauermann SI0-5/0; 5/0V) (SLP-5AAUW; required - shipped with unit) Three-pole Disconnect Switch (TAZ-MS0) Air Outlet Guide (MAC-889SG) Mounting Base (DSD-400P) Mounting Pad (ULTRILITE) Wall Mounting Bracket (QSWB000M-) Controller Options Wireless Controller (MHK) Wired Remote Controller (PAR-MAA-J) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-US444CN-) Hand-held Wireless Remote Controller (PAR-FLMA; req.par-fama-e) Wireless Signal Receiver Module PAR-FAMA (for PAR-FLMA-E) SPECIFICATIONS Cooling Rated Capacity....8,400 Btu/h to Capacity Range...,00-0,900 Btu/h SEER...5.0 Btu/h/W EER...0 Btu/h/W Total Input....700 W Heating at 47 F Rated Capacity....0,900 Btu/h to Capacity Range...,00-4,00 Btu/h HSPF...9.6 Btu/h/W COP...44 Total Input....90 W Heating at 7 F Rated Capacity....6,00 Btu/h Rated Total Input...740 W COP...46 Capacity **...6,00 Btu/h Total Input...,040 W Cooling Indoor: 80º F (7º C) DB / 67º F (9º C) WB * Cooling Outdoor: 95º F (5º C) DB / 75º F (4º C) WB * Heating at 47º F Indoor: 70º F (º C) DB / 60º F (6º C) WB * Heating at 47º F Outdoor: 47º F (8º C) DB / 4º F (6º C) WB * Heating at 7º F Indoor: 70º F (º C) DB / 60º F (6º C) WB * Heating at 7º F Outdoor: 7º F (-8º C) DB / 5º F (-9º C) WB * * Rating Conditions per AHRI Standard ** Capacity is at full speed and performance for INVERTER-driven System. Electrical Requirements Power Supply... 08 / 0V, -Phase, 60 Hz Recommended Fuse/Breaker Size....5 A Voltage Indoor - Outdoor S-S...AC 08 / 0V Indoor - Outdoor S-S...DC ±4V OPERATING CONDITIONS Cooling 4 Heating Indoor Intake Air 90 F ( C) DB 7 F ( C) WB 67 F (9 C) DB 57 F (4 C) WB 80 F (7 C) DB 67 F (9 C) WB 70 F ( C) DB 60 F (6 C) WB Outdoor Intake Air 5 F (46 C) DB 4 F (-0 C) DB 75 F (4 C) DB 65 F (8 C) WB -4 F (-0 C) DB -5 F (- C) WB 5 4 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 5 System cuts out at -9º F (-7º C) to avoid thermistor error and automatically restarts at -4º F (-0º C). MCA... A Fan Motor Output...5 W Fan Motor (ECM)...0. F.L.A. Airflow (Lo - Med - Hi).... 80-0 - 50 Dry CFM 50-90 - 0 Wet CFM Air Filter...Polypropylene Honeycomb Sound Pressure Level (Lo - Med - Hi)...9 - - 8 db(a) DIMENSIONS UNIT GRILLE W -7/6 / 570 5-5/8 / 650 D -7/6 / 570 5-5/8 / 650 H 9-/4 / 5 /6 / 0 Weight (Unit/) Lbs...... 6 / 7 kg....6.5 / External Finish (Unit/)... Galvanized-steel Sheets / Munsell 6.4Y 8.9 / 0.4 Field Drainpipe Size O.D.....-/4" / mm Compressor...DC Inverter-driven MCA... A MOCP....5 A Fan Motor (ECM)...0.50 F.L.A. Sound Pressure Level Cooling...46 db(a) Heating...50 db(a) DIMENSIONS W -/ / 800 D -/4 / 85 H -5/8 / 550 Weight...66 lbs. / 0 kg External Finish... Munsell No. Y 7.8 /. Type...R40A Pipe Size O.D. Gas Side.../8" / 9.5 mm Liquid Side..../4" / 6.5 mm Max. Pipe Length.... 65' / 9 m Max. Pipe Height Difference... 40' / m Connection Method...Flared 06 Mitsubishi Electric US, Inc.
DIMENSIONS: SLZ-KA09NA Unit : inch (mm) 9/~-5/(5~7) 9/~-5/(5~7) Ceiling hole -/6~4-/(576~60) Fresh air intake 6-7/(40) 0-7/8(50) -7/6(570) -/6(5) -7/() -7/6(570) Detail drawing of fresh air intake -5/6( 00) - /8(.8) Burring hole 0 4-/(8) (5) -7/8( 7.4) Cut out hole 0 -/4(57) -7/(56) 7-7/(99) -7/(5) -/6(5) 9/~-5/(5~7) -/6~4-/(576~60) Ceiling hole 9/~-5/(5~7) -7/6(87) -9/(66) 4-/4() -/(9) pipe (gas) pipe (liquid) -/~-9/(8~58) Suspension bolt lower edge /(7) 7-5/6(0) Terminal block 9-/6(0) Drain pipe VP-5 connection (O.D. -/4( )) Suspension bolt M0 or W/8 7-9/(9) 8-/6(08) 9-/4(5) +/6 +5 0 (7 0 ) 5/(0) -/6 Wiring entry 7-5/(8) -7/8(48) 5-9/(650) -7/(0) -5/(55) -/8(5) 5-9/(650) -7/(0) Brand label Drain hole Auto vane 4-7/(77) Models SLZ-KA09NA SLZ-KANA SLZ-KA5NA (liquid) /4 inch ( 6.5mm) /4 inch ( 6.5mm) /4 inch ( 6.5mm) (gas) /8 inch ( 9.5mm) /8 inch ( 9.5mm) / inch (.7mm) 4-7/(77) -/8(5) -5/(55) Air intake grille Vane motor 06 Mitsubishi Electric US, Inc.
DIMENSIONS: SUZ-KA09NA 40 Satellite Boulevard. Suwanee, GA 004 Toll Free: 800-4-48 www.mehvac.com FORM# SLZ-KA09NA - SUZ-KA09NA - 0604 06 Mitsubishi Electric US, Inc.
M-SERIES SUBMITTAL DATA: SLZ-KANA & SUZ-KANA,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS Job Name: System Reference: Date: ENERGY STAR...Yes ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Electrical Requirements Power Supply... 08 / 0V, -Phase, 60 Hz Recommended Fuse/Breaker Size....5 A Voltage Indoor - Outdoor S-S...AC 08 / 0V Indoor - Outdoor S-S...DC ±4V : SLZ-KANA : SUZ-KANA GENERAL FEATURES Four-way 'x' ceiling-cassette indoor unit for ceiling recessed applications Built-in drain mechanism for condensate removal; lifts to 9-/6" Wide air-flow pattern for better air distribution Design features ventilation air intake knockout Long-life air filter included with indoor unit Indoor unit powered from outdoor unit using A-Control Choice of fan speed: Low, Medium, High Automatic restart following a power outage Limited warranty: five years parts and seven years compressors ACCESSORIES Condensate Pump (BlueDiamond X87-7/7; 5/0V) Condensate Pump (Sauermann SI0-5/0; 5/0V) (SLP-5AAUW; required - shipped with unit) Three-pole Disconnect Switch (TAZ-MS0) Air Outlet Guide (MAC-889SG) Mounting Base (DSD-400P) Mounting Pad (ULTRILITE) Wall Mounting Bracket (QSWB000M-) Controller Options Wireless Controller (MHK) Wired Remote Controller (PAR-MAA-J) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-US444CN-) Hand-held Wireless Remote Controller (PAR-FLMA; req.par-fama-e) Wireless Signal Receiver Module PAR-FAMA (for PAR-FLMA-E) SPECIFICATIONS Cooling Rated Capacity....,00 Btu/h to Capacity Range...,400 -,00 Btu/h SEER...5.4 Btu/h/W EER...0 Btu/h/W Total Input....90 W Heating at 47 F Rated Capacity....,600 Btu/h to Capacity Range...,00-7,00 Btu/h HSPF...9.6 Btu/h/W COP...8 Total Input....,80 W Heating at 7 F Rated Capacity....8,00 Btu/h Rated Total Input...90 W COP...6 Capacity **...8,00 Btu/h Total Input...,0 W Cooling Indoor: 80º F (7º C) DB / 67º F (9º C) WB * Cooling Outdoor: 95º F (5º C) DB / 75º F (4º C) WB * Heating at 47º F Indoor: 70º F (º C) DB / 60º F (6º C) WB * Heating at 47º F Outdoor: 47º F (8º C) DB / 4º F (6º C) WB * Heating at 7º F Indoor: 70º F (º C) DB / 60º F (6º C) WB * Heating at 7º F Outdoor: 7º F (-8º C) DB / 5º F (-9º C) WB * * Rating Conditions per AHRI Standard ** Capacity is at full speed and performance for INVERTER-driven System. OPERATING CONDITIONS Cooling 4 Heating Indoor Intake Air 90 F ( C) DB 7 F ( C) WB 67 F (9 C) DB 57 F (4 C) WB 80 F (7 C) DB 67 F (9 C) WB 70 F ( C) DB 60 F (6 C) WB Outdoor Intake Air 5 F (46 C) DB 4 F (-0 C) DB 75 F (4 C) DB 65 F (8 C) WB -4 F (-0 C) DB -5 F (- C) WB 5 4 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 5 System cuts out at -9º F (-7º C) to avoid thermistor error and automatically restarts at -4º F (-0º C). MCA... A Fan Motor Output...0 W Fan Motor (ECM)...0.8 F.L.A. Airflow (Lo - Med - Hi).... 80-0 - 90 Dry CFM 50-90 - 50 Wet CFM Air Filter...Polypropylene Honeycomb Sound Pressure Level (Lo - Med - Hi)...0-4 - 9 db(a) DIMENSIONS UNIT GRILLE W -7/6 / 570 5-5/8 / 650 D -7/6 / 570 5-5/8 / 650 H 9-/4 / 5 /6 / 0 Weight (Unit/) Lbs...... 6 / 7 kg....6.5 / External Finish (Unit/)... Galvanized-steel Sheets / Munsell 6.4Y 8.9 / 0.4 Field Drainpipe Size O.D.....-/4" / mm Compressor...DC Inverter-driven MCA... A MOCP....5 A Fan Motor (ECM)...0.50 F.L.A. Sound Pressure Level Cooling...49 db(a) Heating...5 db(a) DIMENSIONS W -/ / 800 D -/4 / 85 H -5/8 / 550 Weight...77 lbs. / 5 kg External Finish... Munsell No. Y 7.8 /. Type...R40A Pipe Size O.D. Gas Side.../8" / 9.5 mm Liquid Side..../4" / 6.5 mm Max. Pipe Length.... 65' / 9 m Max. Pipe Height Difference... 40' / m Connection Method...Flared 06 Mitsubishi Electric US, Inc.
DIMENSIONS: SLZ-KANA Unit : inch (mm) 9/~-5/(5~7) 9/~-5/(5~7) Ceiling hole -/6~4-/(576~60) Fresh air intake 6-7/(40) 0-7/8(50) -7/6(570) -/6(5) -7/() -7/6(570) Detail drawing of fresh air intake -5/6( 00) - /8(.8) Burring hole 0 4-/(8) (5) -7/8( 7.4) Cut out hole 0 -/4(57) -7/(56) 7-7/(99) -7/(5) -/6(5) 9/~-5/(5~7) -/6~4-/(576~60) Ceiling hole 9/~-5/(5~7) -7/6(87) -9/(66) 4-/4() -/(9) pipe (gas) pipe (liquid) -/~-9/(8~58) Suspension bolt lower edge /(7) 7-5/6(0) Terminal block 9-/6(0) Drain pipe VP-5 connection (O.D. -/4( )) Suspension bolt M0 or W/8 7-9/(9) 8-/6(08) 9-/4(5) +/6 +5 0 (7 0 ) 5/(0) -/6 Wiring entry 7-5/(8) -7/8(48) 5-9/(650) -7/(0) -5/(55) -/8(5) 5-9/(650) -7/(0) Brand label Drain hole Auto vane 4-7/(77) Models SLZ-KA09NA SLZ-KANA SLZ-KA5NA (liquid) /4 inch ( 6.5mm) /4 inch ( 6.5mm) /4 inch ( 6.5mm) (gas) /8 inch ( 9.5mm) /8 inch ( 9.5mm) / inch (.7mm) 4-7/(77) -/8(5) -5/(55) Air intake grille Vane motor 06 Mitsubishi Electric US, Inc.
DIMENSIONS: SUZ-KANA 40 Satellite Boulevard. Suwanee, GA 004 Toll Free: 800-4-48 www.mehvac.com FORM# SLZ-KANA - SUZ-KANA - 0604 06 Mitsubishi Electric US, Inc.
M-SERIES SUBMITTAL DATA: SLZ-KA5NA & SUZ-KA5NA 5,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS Job Name: System Reference: Date: Electrical Requirements Power Supply... 08 / 0V, -Phase, 60 Hz Recommended Fuse/Breaker Size....5 A Voltage Indoor - Outdoor S-S...AC 08 / 0V Indoor - Outdoor S-S...DC ±4V : SLZ-KA5NA : SUZ-KA5NA GENERAL FEATURES Four-way 'x' ceiling-cassette indoor unit for ceiling recessed applications Built-in drain mechanism for condensate removal; lifts to 9-/6" Wide air-flow pattern for better air distribution Design features ventilation air intake knockout Long-life air filter included with indoor unit Indoor unit powered from outdoor unit using A-Control Choice of fan speed: Low, Medium, High Automatic restart following a power outage Limited warranty: five years parts and seven years compressors ACCESSORIES Condensate Pump (BlueDiamond X87-7/7; 5/0V) Condensate Pump (Sauermann SI0-5/0; 5/0V) (SLP-5AAUW; required - shipped with unit) Three-pole Disconnect Switch (TAZ-MS0) Air Outlet Guide (MAC-889SG) Mounting Base (DSD-400P) Mounting Pad (ULTRILITE) Wall Mounting Bracket (QSWB000M-) Controller Options Wireless Controller (MHK) Wired Remote Controller (PAR-MAA-J) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-US444CN-) Hand-held Wireless Remote Controller (PAR-FLMA; req.par-fama-e) Wireless Signal Receiver Module PAR-FAMA (for PAR-FLMA-E) SPECIFICATIONS Cooling Rated Capacity....5,000 Btu/h to Capacity Range...,800-7,700 Btu/h SEER...6.0 Btu/h/W EER...0. Btu/h/W Total Input....,460 W Heating at 47 F Rated Capacity....8,000 Btu/h to Capacity Range...,00 -,00 Btu/h HSPF...9.6 Btu/h/W COP...7 Total Input....,950 W Heating at 7 F Rated Capacity....0,00 Btu/h Rated Total Input...,0 W COP...99 Capacity **...,000 Btu/h Total Input...,970 W Cooling Indoor: 80º F (7º C) DB / 67º F (9º C) WB * Cooling Outdoor: 95º F (5º C) DB / 75º F (4º C) WB * Heating at 47º F Indoor: 70º F (º C) DB / 60º F (6º C) WB * Heating at 47º F Outdoor: 47º F (8º C) DB / 4º F (6º C) WB * Heating at 7º F Indoor: 70º F (º C) DB / 60º F (6º C) WB * Heating at 7º F Outdoor: 7º F (-8º C) DB / 5º F (-9º C) WB * * Rating Conditions per AHRI Standard ** Capacity is at full speed and performance for INVERTER-driven System. OPERATING CONDITIONS Cooling 4 Heating Indoor Intake Air 90 F ( C) DB 7 F ( C) WB 67 F (9 C) DB 57 F (4 C) WB 80 F (7 C) DB 67 F (9 C) WB 70 F ( C) DB 60 F (6 C) WB Outdoor Intake Air 5 F (46 C) DB 4 F (-0 C) DB 75 F (4 C) DB 65 F (8 C) WB -4 F (-0 C) DB -5 F (- C) WB 5 4 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 5 System cuts out at -9º F (-7º C) to avoid thermistor error and automatically restarts at -4º F (-0º C). MCA... A Fan Motor Output...0 W Fan Motor (ECM)...0.8 F.L.A. Airflow (Lo - Med - Hi).... 80-0 - 90 Dry CFM 50-90 - 50 Wet CFM Air Filter...Polypropylene Honeycomb Sound Pressure Level (Lo - Med - Hi)... - 5-40 db(a) DIMENSIONS UNIT GRILLE W -7/6 / 570 5-5/8 / 650 D -7/6 / 570 5-5/8 / 650 H 9-/4 / 5 /6 / 0 Weight (Unit/) Lbs...... 6 / 7 kg....6.5 / External Finish (Unit/)... Galvanized-steel Sheets / Munsell 6.4Y 8.9 / 0.4 Field Drainpipe Size O.D.....-/4" / mm Compressor...DC Inverter-driven Twin Rotary MCA... A MOCP....5 A Fan Motor (ECM)...0.50 F.L.A. Sound Pressure Level Cooling...49 db(a) Heating...5 db(a) DIMENSIONS W -/ / 800 D -/4 / 85 H -5/8 / 550 Weight...80 lbs. / 6 kg External Finish... Munsell No. Y 7.8 /. Type...R40A Pipe Size O.D. Gas Side.../" /.7 mm Liquid Side..../4" / 6.5 mm Max. Pipe Length.... 65' / 9.8 m Max. Pipe Height Difference... 40' /. m Connection Method...Flared 06 Mitsubishi Electric US, Inc.
DIMENSIONS: SLZ-KA5NA Unit : inch (mm) 9/~-5/(5~7) 9/~-5/(5~7) Ceiling hole -/6~4-/(576~60) Fresh air intake 6-7/(40) 0-7/8(50) -7/6(570) -/6(5) -7/() -7/6(570) Detail drawing of fresh air intake -5/6( 00) - /8(.8) Burring hole 0 4-/(8) (5) -7/8( 7.4) Cut out hole 0 -/4(57) -7/(56) 7-7/(99) -7/(5) -/6(5) 9/~-5/(5~7) -/6~4-/(576~60) Ceiling hole 9/~-5/(5~7) -7/6(87) -9/(66) 4-/4() -/(9) pipe (gas) pipe (liquid) -/~-9/(8~58) Suspension bolt lower edge /(7) 7-5/6(0) Terminal block 9-/6(0) Drain pipe VP-5 connection (O.D. -/4( )) Suspension bolt M0 or W/8 7-9/(9) 8-/6(08) 9-/4(5) +/6 +5 0 (7 0 ) 5/(0) -/6 Wiring entry 7-5/(8) -7/8(48) 5-9/(650) -7/(0) -5/(55) -/8(5) 5-9/(650) -7/(0) Brand label Drain hole Auto vane 4-7/(77) Models SLZ-KA09NA SLZ-KANA SLZ-KA5NA (liquid) /4 inch ( 6.5mm) /4 inch ( 6.5mm) /4 inch ( 6.5mm) (gas) /8 inch ( 9.5mm) /8 inch ( 9.5mm) / inch (.7mm) 4-7/(77) -/8(5) -5/(55) Air intake grille Vane motor 06 Mitsubishi Electric US, Inc.
DIMENSIONS: SUZ-KA5NA 40 Satellite Boulevard. Suwanee, GA 004 Toll Free: 800-4-48 www.mehvac.com FORM# SLZ-KA5NA - SUZ-KA5NA - 0604 06 Mitsubishi Electric US, Inc.