Electric Floor Heating Cables

Similar documents
L J Visit to learn about the Danfoss Installer Certification program. Dual Self-Adhesive Mats. Installs in minutes!

Toll Free:

ComfortTile Floor Heating Systems

radiant floor heating Floor Heating Mats Floor Heating Cables Thermostats

Classic Mats Installation Manual

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

Warm Feet For Uncoupling Membrane Pour membrane de désolidarisation. Installation Guide Floor Heating Cable

Anti frost. Snow Melting USA 2012 USA 2014

SECTION LOW VOLTAGE LIGHTING CONTROLS

Electric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada

ELEKTRA RadiantFloor Heating

Thermal Devices, Inc. Mount Airy, Maryland USA C D E F. Typical Maxiband Clamping

FOR TM-16 EMERGENCY WARNING SYSTEM

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

Affiliations: Code Listings and Standards C O U N C I L

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

amuheat Cable Mat floor heating systems Installation Manual CM02-12

FloorHeat Installation Manual

the Cold Chase Away commercial and residential product guide

Installation Guide For your AHT Underfloor Heating System

Installation, Operation, and Troubleshooting Instructions

CATALOG. Toll Free:

T5000 LCD Digital Fan Coil Thermostat

stock code 5265 FIXING GUIDE Thermonet underfloor heating programmable thermostat kit

Electric Floor Heating & Snow Melting Solutions

IdealFILM. Do-It-Yourself Installation Manual

INSTALLATION MANUAL ES-TERRAIN-SYS-4.1 ES-TERRAIN-SAT-2.0 ES-TERRAIN-SUB ES-TERRAIN-SAT-2.0 ES-TERRAIN-SYS-4.1 ES-TERRAIN-SUB

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

PLSRR Heat Trace Cable Data Sheet

Underwood Heater Installation Manual

Schneider Electric Erie T155 Series

TM Series. Induced Draft, Counter Flow Optional Accessories

Paragon. Induced Draft, Counter Flow Optional Accessories

Part Number Color Cool Current Dimensions -H x W x D (Inch) Voltage Description THM5320R1000 Gray 1.0 A running 8-1/8 x 8 x 1-7/8 18 to 30 Vac

Installation Guide Heating Elements

GE LightSweep Lighting Control System Guideform Specification

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

emat Pro 100/150/200 Installation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SEALED ENCLOSURE COOLING

Installation Guide - Heating Cables. Installation Guide. Heating cables. for In-Slab and In-Screed Applications BROCDEV135.1

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Toll Free:

Self-regulating Roof Heat Cable

TraceNet TM TCM2 CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

HEAT CABLE underfloor heating

LIFETIME. INSTALLATION MANUAL emat Pro 100w/150w/200w WARRANTY

Climate Cŏntrol Multifunction Hydronic Control Installation and Operation Manual. Uponor Radiant Heating and Cooling Systems

DOMOTHERM CLASSIC TWIN/S MAT

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Self-regulating Roof Heat and Gutter Trace Cable

FUSION ALARMS TROUBLESHOOTING GUIDE CURRENT LIMIT VOLTAGE LIMIT

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

CATALOG. Toll Free:

Installation, Operation & Service Manual

Underfloor Heating. undertile heating

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Intro. Intro. Table of Contents

EasyWire Between Joists Installation Instructions

SECTION ELECTRIC FLOOR HEATING AND SNOW MELTING EQUIPMENT

Viking Installation Guide

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

AS950 REFRIGERATED SAMPLERS

OPERATION AND MAINTENANCE MANUAL ELC-810 AUTOMATIC WATER LEVEL CONTROLLER. AquatiControl Technology

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

wireless. web-based. worthy of the name RACO.

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

PARTS AND SERVICE MANUAL FOR MERCO HOLDING CABINET MODEL 86002

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

Ramsey Motion Monitoring Systems

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

Service Handbook. Servicing should only be performed by a Qualified Service Agent.

SWITCH PRODUCTS SAFETY & SIGNAL MATS SENSING EDGES SENSING BUMPERS INTERFACE CONTROLLERS LIGHT CURTAINS CUSTOM DESIGNS

Polymer solutions Heating mat EM2-CM

Battery charger modules

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

TC-5231 Series, TC-5232, & TC-5241 Series

RE-PR3-E-27 3-Phase Panel Mount 27kW

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Motogard. Over Temperature Protection System. Installation Instructions

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Model 4001 Series Single Channel Controller

Electro-HELPS XV ELECTRO-BOILER SPECIFICATIONS. A complete product line to fi t all your application needs. Made in USA

Foil Heaters. Installation Manual: TECHNICAL HELPLINE

RACK-MOUNT Air Conditioners

Excel-EN Conventional Fire Control Panel

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Carbon Film Installation Instructions

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Installation and User Instructions

Transcription:

Electric Floor Heating Cables Danfoss LX Electric Floor Heating Cable Systems combine the highest comfort levels with the maximum energy efficiency. Our Electric Floor Heating Cable Systems offer the following features: Single point connection Twin conductor cable Eliminates EMF's (electromagnetic fields) Safety approved for wet locations Flexible installation Durable construction Genuine 20-year non-prorated warranty, includes labor and materials Installation Attach the Danfoss cable strapping to the sub floor (3' - 4' apart) Technical Data Cable Construction: Twin Conductor Cable Diameter: 3/6" (4.8mm) Rated Voltage: 20V, 208V, 240V Max. Rated temperature: 22 F (00 C) Conductor Insulation: Teflon FEP Outer Insulation: PVC Flexible installation! c@us Place the LX cable in the tabs (3" standard spacing) LX Thermostat Cable Strapping Clip the LX Cable in place LX Floor Heating Cable Please visit our You Tube channel for step by step installation instructions: www.youtube.com/danfosslx Please take into consideration the locations of sinks, tubs, toilets and objects on the floor when measuring the floor area 3

Electric Floor Heating Cables Approximate Heat Coverage Length (sq.ft.) Watts (feet) 2"spacing Standard 4"spacing (3W/ft.) 3"spacing 088L340 40 5 0 5.0 20 088L34 60 0 5 20.5 80 088L342 80 5 20 25 2.0 240 088L343 20 20 30 40 3.0 360 088L344 60 25 40 55 4.0 480 088L345 200 35 50 65 5.0 600 088L346 240 40 60 80 6.3 750 088L347 280 45 70 95 7.2 860 088L348 35 50 80 05 8.0 960 20V LX Strapping included: feet (m) 5 (4.6) 5 (4.6) Approximate Heat Coverage Length (sq.ft.) Watts (feet) 2"spacing Standard 4"spacing (3W/ft.) 3"spacing 088L3080 80 5 20 25.0 245 088L308 20 20 30 40.5 365 088L3082 60 25 40 55 2.0 480 088L3083 200 35 50 65 2.5 605 088L3084 240 40 60 80 3.0 725 088L3085 280 45 70 95 3.5 840 088L3086 320 55 80 05 4.0 965 088L3087 360 60 90 20 4.5 080 088L3088 400 65 00 35 5.0 200 088L3089 440 75 0 45 5.5 330 088L3090 480 80 20 60 6.5 445 088L309 570 95 40 90 7. 70 088L3092 630 05 60 20 8.0 95 240V LX Strapping included: feet (m) 05 (32.0) 05 (32.0) Notes: Cable strapping is supplied with product. Additional cable strapping can be ordered separately (See pg.6) 2" centers provide 8W/sq.ft. 3" centers provide 2W /sq.ft. 4" centers provide 9W/sq.ft. Watt output of the 240V cable is reduced by 25% when operated at 208V (approximately 2W/ft.) Power leads are 0 feet in length Floor sensor conduit is not included (Part # 9809099) Contactor or Power Module is required for loads exceeding 5 amps on a single thermostat (See Pg. 6) Controls - See PG. 5 Accessories- See PG. 6 4

.,.3" I t,j - - Electric Floor Heating Thermostats The Danfoss LX Thermostat raises the bar for aesthetic appeal while offering industry-leading functionality. The LX electronic thermostat offers optimum comfort and numerous user friendly features: Large backlit display for easy programming Includes Class-A GFCI for safety (approved for wet locations) Simple to program with intuitive on-screen menus Monitor energy consumption Dual voltage capability (can operate at either 20V or 240V) Four event, seven day ENERGY SAVINGS programming Easily upgrade older model LX thermostats - Non-Programmable =. Part# 088L533 Technical Data LX Thermostats Temperature Range: 40 F to 04 F S C to 40 C GFCI: Class A (SmA trip level) Supply Voltage: 20V - 240V max., 50/60Hz Max. Load: SA max (resistive load) Max. Power:,800W at 20VAC 3,600W at 240VAC Programmable Thermostat 4.80" X 3.00" X.00" Dimensions (HxWxD): 23mm x 74mm x 25mm Manual Thermostat 4.65"x 2.90"x.90" Dimensions (HxWxD): 8mm x 74mm x 48mm c@us LX Thermostats 20V-240V 088L530 LX Programmable Thermostat with Floor Sensor 088L532 LX Programmable Thermostat with Air Sensor (and floor temperature limiter) 088L533 LX Non-Proqrammable Thermostat with Floor Sensor Note: All Thermostats include a Floor Sensor with a 0 foot lead. 5

LX Power Module The LX Series Power Module makes it easy to connect more heating mats or cables to the same thermostat without the need for contactor panels. An easy control solution for large areas Receives on/off command from the main thermostat Each Power Module adds SA switching capability Up to 5 Power Modules can be added to the thermostat Includes Class-A GFCI for safety (approved for wet locations) For use with Programmable LX thermostat only Power Module/ Contactor Max. 088L535 Power Module with GFCI 5 088L3450 Single Contactor, 600V max. 40 088L345 Single Contactor, 600V max. 40 Contactor or LX Power Module is required for loads exceeding 5 on a single thermostat All contactors are complete with NEMA enclosure Coil Voltage N/A 20 208-240 No.of Contactors Cable Strapping Part # 088L 050/5 Little Buzzer Electric Floor Heating Accessories LX Accessories 088L050 Cable Strapping (5 ft/4.5 m) 088L054 Cable Strapping (75 ft/22.9 m) 088L3008 Replacement floor sensor for LX Thermostat 088L004 LX Repair Kit (includes: crimp connectors, repair wire, heat shrink, tubes) 9809099 Sensor Conduit (8 ft) 088L0028 Little Buzzer (continuity alarm) Little Buzzer - Continuity Alarm (088L0028) Simplify your installation process by using the Little Buzzer by Danfoss. The Little Buzzer is designed to monitor Danfoss Heating Mats or Cables during installation and will sound an alarm if the heating element is cut or damaged. This allows an easy repair before the floor covering is laid. The Little Buzzer is battery powered with a set of batteries included. NOTE: A continuity alarm does not replace the need for measuring and verifying the Ohm resistance three times throughout the installation process. Failure to do so may result in voiding the warranty. Part# 088L0028 Sensor Conduit 0Part# 9809099 LX Repair Kit Part# 088L004 Floor Sensor Part# 088L3008 For technical assistance call: Toll Free: 888-448-0555 6

Comfort Radiant Heating at 888-448-0555 or on the web at Comfort Radiant Heating 9 Morris Lane Clifton Park, NY 2065 888-448-0555 fax 58-373-035 88-448-0555 fax 58-373-035