XIII Troubleshooting

Similar documents
EG & PEG Series 5 EGH Series 5

TWZ/CT/ODV Series. Oil-Fired Hot Water Boilers (Less Tankless Heater) These instructions must be affixed on or adjacent to the boiler

Electronic Ignition Water Heater

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

COMMERCIAL 24 VOLT FLUE DAMPER

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

24 VAC Intermittent Pilot Gas Ignition Control

EGH Series 5. Control Supplement. EGH-105 to EGH-125 Natural gas CSD-1 control system

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS GAS BOILER

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

PDV(S,T) MODEL SERIES AND INDUCED DRAFT (D80T725, D65T625) MODEL SERIES WATER HEATERS WITH HONEYWELL INTEGRATED CONTROL SYSTEM

Is a heating protection plan really worth it? Decide for yourself!

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

Flame Safeguard Fault Code Diagnostics

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

COMBUSTION AIR SYSTEM

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Burn Easy Installation Instructions LP or Natural Gas Fired Units. Cremator Setup:

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Ultra Low NOx PowerVent with Honeywell Electronic Control California Only

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

COMMERCIAL 24 VOLT FLUE DAMPER

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Technical

RM2604 & RM2804 Gas Controls

Northwest RV Supply Manual Compliments of Printed From 900 & 9100 Series

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

DC50X2 Models 50 Pound Stacked Commercial Dryer. Troubleshooting,Fault Codes, and Schematics. Starting serial number Part # /13

New Power Vented Rheem FVIR Tanks

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Service Manual Model 3163

AHE S -12 VDC AHE S - 24 VDC

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

Installation & Troubleshooting Requirements

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

Figure 10 or Figure 6

Model 60200FR Gas Primary Control Data Sheet

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

Q - Series Boiler. Troubleshooting Manual

SLANT/FIN AUTOMATIC VENT DAMPER For Galaxy, Sentinel and Sentry Series Boilers INSTALLATION INSTRUCTION MANUAL AND TROUBLESHOOTING GUIDE

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR SERIES 3

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

Control manual and troubleshooting guide

SERVICING S-15 CHECKING CAPACITOR

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

ELECTRONIC FIREPLACE DAMPER

24 VAC SYSTEM CONTROL KIT

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules

POWER VENTER. Model: PVE Series

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

User s Information Manual

Model Universal Oil Primary Control

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

ELECTRONIC FIREPLACE DAMPER

D896 Automatic Vent Damper

10.1 Troubleshooting Condition Table

WARNING FLAIR INTERNATIONAL CORPORATION 600 OLD WILLETS PATH HAUPPAUGE, NEW YORK U.S.A. TEL.: (516) FAX: (516) AMERICAN

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

WARNING FIRE OR EXPLOSION HAZARD.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR SERIES 3

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Dexter Commercial Vended Stack Washer Dryer. Dryer Troubleshooting, Fault Codes, And Schematics. Starting serial number (12/13)

Technical

FURNACE OPERATION OVERVIEW

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Columbia Boiler Company

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

PVE SERIES POWER VENTER SYSTEM MANUAL

USER S INFORMATION MANUAL (2,4)SG13B

Installation, Operation and Service Manual

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

Technical

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

Test/Function Wrinkle release. Display list of diagnostic codes. Then press Temperature (^) - 13 Key. To sequence thru the diagnostic and help codes.

HWX GAS BOILERS USER S INFORMATION MANUAL

Energy-Efficient, Environmentally-Friendly Heating Solutions. Baxi Luna HT Residential Troubleshooting Guide

Service Handbook COMMERCIAL GAS HIGH EFFICIENCY WATER HEATERS

Drying Tumblers. Troubleshooting. 120 Pound Capacity 170 Pound Capacity. Refer to Page 5 for Model Numbers. Part No August 2007

Technical

WATER MODELS S-34 THROUGH S-150 INSTALLATION AND OPERATING INSTRUCTIONS

DIAGNOSTIC GUIDE DAMP DRY TEST

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

ML180UH SERIES GAS FURNACE WARNING WARNING

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS GAS BOILER

NO VENTING REQUIRED 120V AC;

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

INSTALLATION GUIDE Dual Fuel Ranges

If additional copies of this guide are needed, they may be downloaded at;

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR ES2 ENHANCED SERIES 2 Gas - Fired Boiler

Transcription:

XIII Troubleshooting The following pages contain troubleshooting charts for use in diagnosing control problems. To use these charts, go to the box marked Start at the top of the chart on page 34 or 36 and follow the appropriate path though the chart until a box with a list of possible causes is reached. If the problem is known to be within the ignition system, go directly to the appropriate troubleshooting guide for the boiler. In using these charts, the following should be kept in mind: 1) These charts are only meant to be used by a professional heating technician as an aid in diagnosing control problems. 2) Where applicable, follow all precautions outlined in the appropriate lighting instructions on pages 28-29. 3) In general, these charts assume that there are no loose or miswired electrical s. Before using these charts, inspect all electrical s on the boiler to make sure that they are tight. Also, check the wiring on the boiler against the appropriate wiring diagram in Figures 18-19. 4) The possible causes at the end of each branch in these charts are not listed in order of likelihood. All controls on the CWI are tested at least once in the manufacturing process and a defective control or component is generally the least likely cause. Before replacing a component, try to rule out all other possible causes. 5) These troubleshooting charts assume that the vent is closed at the beginning of the troubleshooting process. With the applied to the boiler and no call for heat, the should go to the closed position. If it does not, do the following: Confirm that is applied to the boiler and that there is no call for heat. Make sure that the switch on the is in the automatic position. Unplug the harness from the and check for pin #1 (blue) and pin #4 (yellow). If voltage is present, the is defective or there is an obstruction in the path of the blade. If no voltage is present, there is either a loose in the harness or the limit control (L8148E or ) is defective. 6) If the charts indicate that the L8148E or is defective, do the following before replacing it: Check for TV and Z. If no voltage is present, the transformer in the L8148E or is defective. It is possible that this transformer has been destroyed by a short circuit in the boiler wiring. Before replacing the control, carefully inspect all low voltage wiring on the boiler for places where it is touching the frame of the boiler or wiring on the other side of the transformer. If is present TV and Z, check for between T and W. On L8148Es, if no voltage is present, make sure that the brass jumper is present between W and Z and that the screws holding this jumper in place are both tight. If the boiler is equipped with a, voltage will only be present T and W when there is a call for heat AD the boiler water temperature high enough to satisfy the low limit. If not already done, temporarily replace the thermostat TV and T with a jumper. If the boiler fires when this is done, there is a problem with the thermostat or zone wiring. If is present T and W and the relay in the L8148E or does not pull in, the relay in this control is probably defective. Inspect the coil of this relay for visible heat damage. If such damage is found, there is a good chance that a second transformer is present in the thermostat or zone valve circuit, resulting in the application of 48 volts the relay coil. In older buildings, this transformer may be hidden in a location far from the boiler. If this second transformer exists, it must be found and removed before the L8148E or is replaced. 7) When checking voltage harness pins, be careful not to insert the meter probes into the pins. Doing so may damage the pin, resulting in a loose when the harness is reconnected. 33

Troubleshooting Chart for CWI Boilers Without Tankless Heaters Caution: Read page 33 before attempting to use this chart Start Thermostat calls for heat Circulator start? Boiler Equipped With Damper? Vent open? *Power off *Blown fuse or tripped breaker *Miswired or loose electrical in 120V line at l1&l2? at C1&C2? terminals at? B and r (limit switch) in L8148E? *Boiler off on limit high limit. Remove t'stat or zone valve end switch wires from t&tv terminals on L8148E. Install temporary jumper terminals t and tv. t&tv? *Seized or defective between pins 1&4 (blue&yellow)and 2&4 (orange&yellow) on end of harness? See ote 7 on page 33. Does run now? *Loose in t'stat or zone valve end switch wiring t'stat or zone valve end switch *T'stat or zone system miswired-consult t'stat or zone valve manufacturer's instructions L8148E-see ote 6 on page 33. *Bad electrical between C1 or C2 and *Obstruction in path of blade motor *Loose between between L8148E harness. L8148E 34

burners light? Do burners shut down before gage temp exceeds high limit +15F? Do burner and shut down at end of call for heat? ED B1&B2? L8148E harness *Loose harness L8148A *Sensing bulb not bottomed out in well standing pilot gas valve terminals or terminals 5&6 on S8600? *Obstruction in path of blade Refer to ignition system troubleshooting chart (page 38). Pull wire off of t terminal on aquastat. Does boiler shut down? spill *Chimney blockage *Chimney system not constructed in accordance with Parts 7 and 10 of ational Fuel Gas Code. *T'stat or zone valve wiring calling for heat rollout *Down draft *Inadequate combustion air supply in boiler room *T'stat wires shorted *Loose electrical in 24 volt wiring between B1 or B2 and gas valve or *Rollout switch open. Replace with exact replacement (see parts list). Check for blocked heat exchanger. *Internal boiler wiring problem, consult Crown representative 35

Troubleshooting Chart for CWI Boilers Equipped with Tankless Heaters and Dampers Caution: Read page 33 before attempting to use this chart Start o call for heat, boiler water temp. at least 20F below low limit Vent open? burners light? Allow boiler water temperature to reach low limit + differential. Initiate call for heat B1and tv on? *Boiler water temp above low limit tv and Z? transformer in l1 & l2? gray wire on rollout switch and B2? standing pilot gas valve terminals or terminals 5&6 on S8600? harness *Loose harness *Obstruction in path of blade *Obstruction in path of blade motor between pins 1&4 (blue&yellow)and 2&4 (orange&yellow) on end of harness? See ote 7 on page 33. *Loose between between harness. tv & Z? *Power off *Blown fuse or tripped breaker *Miswired or loose electrical in 120V line spill rollout *Loose electrical in 24 volt wiring between rollout switch or B2 and gas valve or *Chimney blockage Refer to ignition system troubleshooting chart (page 38). *Chimney system not constructed in accordance with Parts 7 and 10 of ational Fuel Gas Code. *Down draft *Inadequate combustion air supply in boiler room *Rollout switch open. Replace with exact replacement (see parts list). Check for blocked heat exchanger. 36

Circulator start? burners light? Do burners shut down before gage temp exceeds high limit +15F? Do burner and shut down at end of call for heat? ED *Boiler water temperature exceeds high limit at C1&C2? Remove t'stat or zone valve end switch wires from t&tv terminals on. Install temporary jumper terminals t and tv. Does run now? *Loose in t'stat or zone valve end switch wiring t'stat or zone component *T'stat or zone system miswired-consult t'stat or zone valve manufacturer's instructions t&tv? -see ote 6 on page 33. * Boiler water temperature has dropped below low limit terminals at? *Seized or defective *Bad electrical between C1 or C2 and *Sensing bulb not bottomed out in well Pull wire off of t terminal on aquastat. Does boiler shut down? *T'stat or zone valve wiring calling for heat *T'stat wires shorted * Boiler water temperature has dropped below low limit *Internal boiler wiring problem, consult Crown representative 37

Intermittent Ignition System Troubleshooting Chart Start ( is present 24V and 24V (GD) on ignition but main burners do not light) Caution: Read page 33 before attempting to use this chart Spark ignitor/sensor gap? Pilot lights? Does spark stop when pilot lights? burner lights? ED Can you hear sparking? terminals PV & MV/PV at? ignition 24VAC terminals MV & MV/PV on? ignition ignition PV & MV/PV at gas valve? between MV & MV/PV on gas valve? * Break in spark cable insulation * Break in pilot porcelain * Incorrect pilot spark gap in spark cable * Low line pressure EI wiring harness. * Plugged, kinked or leaking pilot tubing * Plugged pilot orifice * Gas line not purged of air in ignition cable or ground wire * Pilot electrode porcelain cracked * Pilot flame not covering gap between electrode and grounding strap * Low gas pressure at gas valve inlet EI harness gas valve ground pilot assembly gas valve ignition 38