GBA Oxy-Tech Co.,Ltd

Similar documents
6868 Ardmore Street Houston, Texas Toll Free Phone Fax

SE300 Build Guide. SeeMeCNC Guides. SE300 Build Guide. Written By: SeeMeCNC seemecnc.dozuki.com/ Page 1 of 16

Oxygen Concentrator Procedure

HERCULES (110V) (220V) USER S MANUAL

INSTALLATION AND USER MANUAL

Half Inch Round LED Rope Light

Unpacking and removing shipping bolts. Connecting the drain line Leveling the washer Connecting to the power supply

Oxygen Concentrator Instruction Booklet

Service Manual for X9.5 and Older Models

Instruction Manual. Please read this manual carefully before operating this unit.

Automatic Ice Maker. Service Manual VT ICEMAKER 15

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Model: AC-108. Instruction Manual

Service Manual. Solar Direct Drive Vaccine refrigerator. Haier Medical and Laboratory Products Co,.Ltd. Model:HTC-60H & HTCD-160.

ZD-985 Desoldering Station

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

A few simple steps to ensure perfect water, every time.

INSTALLATION INSTRUCTIONS

Ceiling Fan Installation Instructions

Installation. Leveling

PWC 1800 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model PWC P/N man Copyright 2011 Vertex Water Products

Owner s Manual Ceiling Fan Installation Instructions

Ceiling Fan Installation Instructions

WATER-WASHED AIR PURIFIER MODEL NO.: KJG-178A OPERATION MANUAL QINGDAO FUNGLAN ENVIRONMENTAL & PROTECTION TECHNOLOGY CO., LTD

TROUBLESHOOTING VANGUARD

Laser engraving & cutting machine installation. Operation Manual

6-inch Intelligent Speed Dome Installation Manual

LDDC Series Double-Deck Drum Pre-cleaner. Instruction Manual LAMBTON MACHINERY(ZHENGZHOU)CO. LTD

INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool Remote Condensing units & Cold plates.

Model DAC12004RC. Please read this manual carefully before use and keep it for future reference.

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

SERVICE MANUAL FOR MODEL RM-10

Inverter Swimming Pool Heat Pump

OWNER S MANUAL CAVN SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

EFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres

Automatic Sublimation Transfer Machine Manual Model. No.: ASTM-40/48/64

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Ceiling Fan Installation Instructions

SUBMERSIBLE WATER PUMP. Model Nos. CSE1 - CSE1A - CSE2 - CSE2A CSD3- -CSD3A CSV1A - CSV2 - CSV2A - CSW1A OPERATING & MAINTENANCE INSTRUCTIONS

Mopit 4 Operator s / Service Manual

2-IN-1 Warm Mist Humidifier with Steam Inhaler

A few simple steps to ensure perfect water, every time.

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

Installation Guide for Stern SPIKE 2 Speaker Light Kits

Dacor Technical Service

E S D REWORK SYSTEM 3 IN 1, I702 USER S GUIDE

DSSHP06G Intelligent Lead Free Soldering Station INSTRUCTION MANUAL

OWNER S MANUAL WASHING MACHINE

A few simple steps to ensure perfect water, every time.

OWNER S MANUAL AVN SERIES RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

MODEL MC-UL592 MC-UL594 POWER SOURCE. 230V - 240V ~ 50 Hz MAX INPUT 1400 W 1500 W NOMINAL INPUT DIMENSIONS (W x L x H)

Ceiling Fan Installation Instructions

V Refrigeration Module

CELEBRITY DELUXE 52" indoor fans

IWATA STUDIO SERIES MAXX JET AIR COMPRESSOR IS-1000

5WF42XX Series Fan UL Model No. : AC-542OD. Owner s Guide and Installation Manual

PWC 7000 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model Copyright 2012 Vertex Water Products

CW-5000/5200 Series Industrial Chiller maintenance manual

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

OXYGEN CONCENTRATORS Information For Our Customers

NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

INSTRUCTION MANUAL. Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Ceiling Fan Installation Instructions

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

SERVICE MANUAL TWIN TUB WASHING MACHINE PWM6010M PWM8010PM PWM1010PM PWM1210PM

5CO52XX Series Fan UL Model No. : 5CO52. Owner s Guide and Installation Manual. Attach sales receipt to this card and retain as your proof of purchase

BK3300/BK3300L. Intelligent Lead free Soldering Station. Instruction Manual V1.0. Warning

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION INSTRUCTIONS

SERVICE MANUAL K LIGHT COMMERCIAL

INSTALLATION, OPERATION AND SERVICE MANUAL AERATION SYSTEMS FEATURING AIR COMPRESSOR AND AIR ELIMINATOR TANK

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

SPLIT TYPE AIR CONDITIONER WAS-09HSTD WINTAIR

HOT WATER BOTTLE BATH PART NUMBER

V Refrigeration Module

Washing Machine OWNER S MANUAL TRWTL-70. Before using your washing machine, please read this manual carefully and keep it for future reference.

FDT11 FDT15 FDT18. DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed)

OWNER S MANUAL CAVS SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER

CONTENT. Ⅰ General information 1. Ⅱ Product description 2. System description 3. Installation 3

CEILING FAN OWNER'S MANUAL

DESIGNER HOOD MODEL: EH-E9122ST(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

After-sales Service Manual for WGG Solar Driven Vaccine Refrigerator

G-10f/GCG-10f UPRIGHT COOLER

20 TON AIR/MANUAL SHOP PRESS

ED4000 & ED5000 SERIES EXIT DEVICES with M61 ALARM OPTION and ED40AK & ED50AK ALARM RETROFIT KIT

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

Mobile Evaporative Cooler. Use & Care Guide MC37 / MC61 INDEX

PWC-500/1000/1010/1500

SOUP MAKER HR2202/80 SHW R1. Technical information. Difference in Power Cord:

USER MANUAL TPS-M5/M55/M555

4 TON HYDRAULIC FLOOR PRESS INSTRUCTION MANUEL

Faucet Series. Installation Guide. Service Hotline Total Free (China) (America)

MAINTENANCE MANUAL TAIYO SEIKI CO., LTD.

OPERATING MANUAL. Reverse Osmosis Equipment Model: Frame Mount Vertical FMV-1 through FMV-6. Made in U.S.A.

CONSTANT SUCTION UNIT

Electrician Installation Manual Majestic Madagascar Ceiling Fan

USER MANUAL WATER DISPENSER WITH ICE MAKER

5800 Refrigerator Compressor Capacitor/Relay Kit

Transcription:

LG101 Oxygen Concentrator Service Manual Working Principle

The Electric Circuit Diagram PSA system Structure Chart

1 Front shell 2 Rear housing 3 left shell 4 right shell 5 pedestal 6 Inlet cover 7 inner support 8 Compressor Support 9 EVA foams 10 upper silencer 11 lower silencer

www.oxygencare.cn Phone:86-755-23733851 12 flow meter 13 silica gel connector 14 air intake filter 15 bacteria filter 16 check valve 17 Compresspor 18 capacitor 19 PCB mainboard 20 membrane switch 21 aerofoil fan 22 AC power cord 23 Anion Generator 24 tieline buckle 25 overload protector 26 The screen plate 27 LED Screen 29 Anion fan 30 foot pad 31 Spring suspension foot 32 Suspension foot pedestal 33 collar nut for outlet 34 Chi joint 35 oxygen generation system 36 Round head cross milling tail self tapping screw 37 Round head cross screws 38 Flat head cross screws 39 Round head cross self-tapping screws 40 Large flat head cross self-tapping screws 41 Round head cross screws http://lovego.en.alibaba.com Fax:86-755-61672247

Common trouble shooting a) Remove the shell b) The oxygen flow of nasal cannula is weak c) LCD display indicator light d) Noisy e) Compressor f) Cooling fan g) Circuit board h) PSA system

www.oxygencare.cn http://lovego.en.alibaba.com Phone:86-755-23733851 Fax:86-755-61672247 Trouble found and repair The following chart will help you analyze and fix the trouble of LG101.If the following suggestions can t help you fix the unit, please connect GBA oxy-tech. Warning In case electric shock, only technician could move the shell. a) Remove the shell Ⅰ Lay down the unit on the table down the six screws at the bottom with screwdriver, 2 screws each side 2 screws back cover. P.S. P 1-1 Ⅱ Press the area nearby A and B with hand. P.S. P 1-2 one by one until the side shell move out by itself, then take off two side shells. The side shells are buckled up by four notches. A notch B notch 6 crews P 1-1 Ⅲ Twist off the 2 screws in handle P.S. P 1-2 P 1-3, take off the air-intake filter, take off silicone silencer joint, move the back shell. Please notice the electric cord.

Air filter P 1-3 b) The oxygen flow of nasal cannula is weak oxygen flow of nasal cannula is weak, when you turn up the flow gauge and the floating ball could be on the top. Take off the humidifier cup, block off the oxygen outlet with hands, watch if the floating ball of flow gauge could back to bottom. Ⅰ If the ball could, the points should be humidifier cup. Re: a. Check the humidifier cup, tighten the cap of humidifier cup. b. Check the tubes of nasal cannula in case bending Ⅱ Turn on the machine and turn up the flow gauge, the ball couldn t down to the bottom when you block off the oxygen outlet. Re:the flow gauge leak. Change the flow gauge. (P.S. P 2-2) Disconnect the tube with the joint of flow gauge(p.s. P 2-1), then screw the joint anti-clockwise direction. Next take out the oxygen gauge and change new.

Oxygen gauge joints Flow gauge P 2-1 P 2-2 Ⅲ When you turn up the flow gauge to top, the ball between the scale 2 to 3 Re:block the outlet to see if the floating ball could be down to bottom. a. If it could, the points is that pipe of machine are blocked by bending. Move the shell to check the oxygen pipe inside of the machine. The following pictures show the easily-bending area(p.s. P 2-3, P 2-4). And smooth it in case bending b. If it couldn t, the point is flow gauge. Change it Oxygen pipe Sway it P 2-3 P 2-4 c) LCD display indicator light Ⅰ turn on the machine, the unit doesn t work and LCD display doesn t on Re:check the power strip first and then check the joint of electric cord power with the

circuit board. Check if it s connected closely. Ⅱ urn on the machine, the unit work but the LCD display shows disordered Re:the program of circuit board error. Change the circuit board. d) Noisy Turn on the machine, the unit works. But it s big noisy, especially unnormal. Re: a. Check if the four screws at the middle bottom of the machine are tightly. Srew down the four screws tightly. b. Check if the leaf of the cooling fan is broken or the cooling fan crushed down. Change the fun and get the broken leaves out e) Compressor Turn on the machine, the compressor screamy. Re:the compressor is aged. Change it f) Cooling fan Ⅰ The noise doesn t happen until the machine run 15 minutes at least Re:Change the cooling fan. Install the fan with the arrow direction down as follow (P.S. P 6-1)

Watch the arrow P 6-1 Ⅱ The machine show over temperature alarm after run 2 hours continuously. And the cover of machine is very hot Re:Check if there is something block the ventilation at the bottom of rear cover. Move the block. Ⅲ The over temperature alarm works when the machine run 20 minutes continuously at least. Re:Check the electric joint of fan with circuit board. Change the fan if the it s closely.(p.s. P 6-2) Joint of fan on circuit board P 6-2

g) Circuit board Ⅰ Turn on machine, the LCD display work normally, machine doesn t run. Re:Check if the joints of circuit board with other parts are closely. Ⅱ Turn on machine, there is a burst of smoke out. Then the machine stop work. Re:Move the shell, change the circuit board and connect the joints.(p.s. P 7-1 ) P 7-1 h) PSA system Ⅰ The floating ball jump up and down drastic. Re:Change the PSA system Ⅱ The oxygen purity can t be 90% at 1 liters oxygen flow. Re:Change the PSA system