Installation & Operation

Similar documents
Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE

PowerVac G Single to Twin Conversion Kit [ ]

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE for MODELS

A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE for MODELS

Dansereau Dental. P r e - C o n s t r u c t i o n G u i d e

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

Vacuum Plumbing Layout Recommendations

PARTS MANUAL. American Dish Service ADS LOW-WATER DISHWASHER MODELS: L3DW / L3DWC EFFECTIVE: MAY, 2008

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Installation Manual CARBONATOR With Plain-Water Booster

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

USER MANUAL/Installation Instructions LRV-4

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

MODEL CMA-180UC PARTS MANUAL Rev 1.16

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

DENTAL VACUUM SYSTEM Part Numbers: VS2O, VS40, VS50, VS50H, VS80 and VS80H RECOMMEND DAILY USE OF MONARCH CLEANSTREAM USER S MANUAL

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

L A signature series TA T N E RE O, A L L A T S IN

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

MODEL CMA-180UC PARTS MANUAL Rev 1.18

Barracuda Dual Wet Dental Vacuum System User Manual

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

Standard Features. Performance/Capacities

STERI-VAC CENTRAL SUCTION SYSTEM

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

ECO1ZN3P, ECO2ZN4P ECO

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

TM Series. Induced Draft, Counter Flow Optional Accessories

PARTS MANUAL. American Dish Service MODEL: 5-AG-S ADS LOW TEMPERATURE DISHWASHER EFFECTIVE: JULY, 2013 C 4/08

Paragon. Induced Draft, Counter Flow Optional Accessories

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

POWER PAK 480V Commercial Steam bath Generator

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Electric Dryer Installation Instructions

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

Read these instructions carefully and completely. NOTE This appliance must be properly grounded.

CHILLER. Operator s & Installation Manual

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM

Dishwasher Installation Manual

Electric Dryer Installation Instructions

PARTS MANUAL. American Dish Service. ADS HIGH TEMP SINGLE RACK DISHMACHINE MODELS: HT-25 5 WIRE 110 Volt Control System

Installation Instructions

Table of Contents. Installation, Operation, and Maintenance Manual V100 Series

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

IMAGE V. Parts and Service Manual

MODEL MW200 MODEL MW600 AIR DRYER

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

Helpful Tip: NOTE:

Owner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00

INSTANT-FLOW C-MICRO WATER HEATER

SUPPLEMENTARY INSTRUCTIONS

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

Installation Instructions

Installation Instructions

Astro Express 2 - Hot Water Delivery System

Installation Instructions

INSTALLATION INSTRUCTIONS

Single Wet Vacuum Pump

Electrical Installation Instructions

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

! WARNING. Before using product, read and understand instructions.

HEATING- Heating Accessories RW List Prices Page X - 1. Bronze B&G Circulator Pumps. Iron Body Red Fox B&G Circulator Pump

TUBS & SURROUNDS FIBERGLASS TUB STANDARD FIBERGLASS GARDEN TUB

Read Only Document Not For Distribution

Installation Instructions

PARTS MANUAL. American Dish Service ADS HIGH TEMP SINGLE RACK DISHMACHINE MODEL: HT Blake Street Edwardsville, Kansas (913)

Table of Contents. Installation, Operation, and Maintenance Manual ELBPxx

OPERATION AND INSTALLATION

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Installation Instructions

Welcome! Today s topic: Small Home Repairs. November 14, 2015

Installation Instructions

KD-27A SERIES DISHWASHERS

1-866-PENNERS

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

CH250 AND CH251 CHILLERS

Special Requirements For Health Care Facilities

Installation Instructions PRO SERIES

Transcription:

2 PVC Vent Pipe 2 PVC Vent Connection (Vent connected to outdoors) 65 (165cm) Conduit (Provided) Disconnect Box (Provided By Electrician) (1 box per pump) 1/4 Comp x 1/4 Comp x 60 (153cm) See notes on Local Codes Air/Water Separator (Included with Separator Models) Optional Wall Mounting (Extra Hose Provided) 1 1/4 x 4 Flex PVC Inlet Tubing (Use PVC Glue) 1 1/2 P-Trap with 1 Air Gap (Refer to Local Plumbing Codes) 1 PVC Slip Coupling and MPT Adapter (Provided) Description: The Vortex by JDS Vacuum Systems have been tested and approved by various regulatory test agencies. The following list provides JDS File Numbers to help with questions that might arise regarding installation inspections. City of Los Angeles Mechanical Testing Laboratory...File #M-050017 ETL Listed under UL Standard for Medical Electrical Equipment.ETL#3124832 Conforms to UL 60601-1 and Certified to CSA/CAN C22.2#601.1 This dental vacuum should only be installed by qualified personnel. Should any questions arise, call JDS Technical Support between hours of 8:30 a.m. to 5:00 p.m. (Pacific Standard Time). Unpacking The System: Place the Vacuum System in a dry, clean, well ventilated area, on a solid, level surface. Consider sound level and insulate as needed. Be sure adequate ventilation is available as the Vacuum System is air cooled. Ambient temperature in the equipment room should be within the temperature range of 40 degrees Fahrenheit (4 C) minimum and to 100 degrees Fahrenheit (38 C) maximum. During the cold weather months, ice may form inside the pump from the residual water after factory performance testing. Allow ice to melt before starting the vacuum to avoid damaging the pump. Remove motor shaft access cap Turn motor using wrench Shaft should run free when all of the ice has melted 1. Remove the cardboard from the shipping platform. 2. Check to be sure that the pump is not damaged and that the Pump Installation Kit is in the box. 3. Remove pump from the shipping platform. 4. Install rubber feet onto the bottom of the pump. JDS 21133 Norwalk Blvd Hawaiian Gardens, CA 90716 Technical Support: (888) 802 4JDS Fax: (562) 924-2273 Email: support@jdsmfg.com Web: www.jdsmfg.com Page 1

JDS Vacuum Pump Specifications: Model Max Users Height Width Depth Ship Weight Total HP Volt Amp Hertz Wire GA Breaker Size JVBTW20S 4 23 in. 28 in. 17 in. 132 lbs. 2 115/208-230 2 x 8 60 12/14 2@20 JVBTW20RS 4 23 in. 28 in. 17 in. 135 lbs. 2 115/208-230 2 x 8 60 12/14 2@20 JVBTW30S 6 26 in. 28 in. 17 in. 150 lbs. 3 115/208-230 2 x 11 60 12/14 2@20 JVBTW30RS 6 26 in. 28 in. 17 in. 154 lbs. 3 115/208-230 2 x 11 60 12/14 2@20 JVBTW40S 8 30 in. 28 in. 17 in. 160 lbs. 4 208-230 2 x 13.4 60 10/12 2@20 JVBTW40RS 8 30 in. 28 in. 17 in. 165 lbs. 4 208-230 2 x 13.4 60 10/12 2@20 Models suffixed with R denotes Recycler Models suffixed with S denotes Air/water Separator Example: Vacuum model JVBTW20R with a Recycler Vacuum model JVBTW20RS with a recycler and separator Options: Most models can be ordered with a recycler, separator, or both by simply adding suffix(es) R and S. Recycler models consume.19 GPM of water. Notes: A consigned electrical circuit with circuit breaker must be provided for each pump. Ambient temperature must be within the range of 40 degrees Fahrenheit (4 C) minimum to 100 degrees Fahrenheit (38 C) maximum. Page 2

IMPORTANT: JDS vacuum systems are to be installed according to local plumbing and electrical codes. Do not operate the equipment without complete and proper grounding. Single Voltage Models Dual Voltage Models Remote Lighted Switch AGC 1 Fuse LOW VOLTAGE CONTROL See Low Voltage Control Remote Lighted Switch AGC ½ Fuse LOW VOLTAGE CONTROL Motor Leads Motor Leads BlK 24 VAC Secondary / e Transformer Solenoid Coil (115V) 115 or 230V Primary From Transformer: Wire if using 230V e Wire if using 208V Wire from Terminal Strip #5 connects to Terminal #2 in motor BlK Vio Vio 24 VAC Secondary Transformer (Vio) Sole noid Coil 115 or 230V Primary () 1 2 3 4 5 6 7 8 GRD 115 Volt supply to terminals 1 and 3 Install Jumpers from terminals: 3 to 4 5 to 6 7 to 8 1 2 3 4 5 6 7 8 GRD 1 2 3 4 5 6 7 8 Wire from Terminal Strip #7 connects to Terminal #4 in motor 1 2 3 4 5 6 7 8 Page 3

A. Plumbing Hook-Up Requirements: Water Line (Recommended) 1/2 inch (13 mm) cold water supply line with shut off valve terminating in 1/2 inch FPT. The line must be flushed out prior to connection to vacuum. IMPORTANT: Water is essential for the operation and longevity of the pump. There must be no interruptions or restrictions of the water supply during operation. Water containing high mineral content may cause mineral build-up and create water starvation, leading to seal failure. A filter and water softener are recommended for this situation. Waste Line Water and air exhaust to sewer line terminating in: Option A Floor sink, an exhaust separator is highly recommended for most installations. Option B P-trap adapted to 3/4 inch (19mm) PVC slip connection. A 1 inch (25mm) air gap may be required by local code. Vacuum Line 3/4 inch (19mm) PVC female slip connection. Guidelines for the proper design of a vacuum piping system are given in the following sections. IMPORTANT: Continuously running sinks or cuspidors must NEVER be connected to the vacuum piping system. B. Electrical Hook-Up Requirements: Low Voltage Line (24V) 18-3 Thermostat wire from remote control switch if low voltage remote control switching is desired. and e wires are for switching, the White wire is for a lighted switch. Line Voltage (60Hz) A single phase, 115 or 208-230 volt, 60Hz., supply circuit with approved ground connection is required. The 1 and 1 1/2 HP units are dual voltage 115/208-230 VAC. Both units are factory wired for 208-230 volt operation: 220 volt operation is recommended for maximum efficiency. An electrical hook-up kit, complete with high voltage switching box, and pre-wired conduit is provided. C. Vacuum Piping System Guidelines: The design of the vacuum piping can have a large effect on the efficiency and reliability of a vacuum system. Experience has shown that the most effective vacuum piping designs are based on the air velocity that will occur in the lines. The velocity must be high enough to entrain all liquids and sediment in the air flow so that they do not accumulate in the lines. At the same time, the velocity must not be so high as to cause unacceptable vacuum losses. The Vacuum Line Sizing Chart on the following page is based on maintaining an optimum air flow velocity according to the criteria described above. Page 4

D. Vacuum Line Size Chart To Vacuum Pump # of Operatories Supplied through Line Pipe Diameter in inches (mm) 1 3/4 (19) 2 1 (25) 3 1 (25) Floor Piping Level Line Termination at Vacuum Pump (Low Restriction Trap) From Vacuum System 4 1 1/4 (32) 5 1 1/4 (32) To Vacuum Pump 6 1 1/2 (38) 7 1 1/2 (38) 8 1 1/2 (38) 9 2 (50) 10 2 (50) 11 2 (50) 12 2 (50) Y-Tee (Flow Diagram) NOTE: Use the number of operatories being supplied, not the number of outlets within the operatories to determine line size at any given point. Branch lines to individual operatories off of the main suction line should be ¾ inch diameter Overhead System Line Termination (Floor Level Junction Box) 1/2 (13mm) Pipe Main Vacuum Line 1/2 (13mm) Line to floor Level Junction Box 45 Elbows 1/2 (13mm) Pip from this bushing to junction box Primary Vacuum Line Overhead System Line Termination (In Wall Junction Box) 1/2 (13mm) Line to Junction Box on Wall A trap is required to prevent backflow A trap is required here to help prevent backflow The vacuum lines should be supported to prevent sag and should be angled 1/4 inch (6 mm) for every 10 ft (3 m) towards the vacuum pump. It is of primary importance to minimize turns of 90 degrees in the system. This not only causes vacuum loss, but exposes areas where sediment can accumulate. A combination of two 45 degree elbows are recommended to a rather than a single 90 degree elbow. Restrictions in the line will also cause vacuum losses. Y-Tee should be used whenever possible. Overhead systems require the use of the next larger size vacuum pump. Overhead systems also require a 1/2 inch (13 mm) line rather than 3/4 inch (19 mm) from the operatories to the main line, and special provisions to ensure that liquids do not travel back into the operatories. A sample vacuum piping diagram is shown. Consult JDS Technical Support for further information regarding vacuum line sizing. Page 5

Air/Water Separator (Provided with Separator Models) Optional Wall Mounting (Extra Hose Provided) 2 PVC Vent (Connects Outside Building) *Do Not Cap* Disconnect Box (One Per Pump) Water Manifold Assembly Water Line 1 1/2 P-Trap with 1 Air Gap (Optional Floor Sink Installation) Operatory Piping Termination 6 E. Installing Vacuum System With Exhaust Separator 1. Place the vacuum unit on a solid level floor within two feet (0.6 m) of waste line P-trap or floor sink. 2. Connect operatory vacuum line to the pump suction strainer using PVC pipe or the provided suction hose and glue with PVC type cement. 3. Attach the provided 3/4 inch (19 mm) pump exhaust hose to inlet fitting of the exhaust separator, and glue with PVC type cement. 4. Attach provided 3/4 inch (19 mm) drain hose to P-trap or floor sink from bottom drain fitting of exhaust separator and glue with PVC type cement. 5. Install 2 inch (51 mm) PVC vent line off the top of the exhaust separator and vent to the outdoors. 6. Connect the provided brass water manifold with shut-off valve to a 1/2 inch (13 mm) water supply line. 7. Connect high voltage electrical supply line to the pump as indicated in the electrical diagram. 8. For low voltage remote control, connect low voltage wires of corresponding color from the Apollo Master Control Panel vacuum switch. Page 6

F. Initial Start-Up 1. Check that water supply valve is OPEN. 2. Start the pump. 3. Check exhaust tubing to ensure that water is flowing through the pumps. IMPORTANT: Do not run pump without full pressure water supply, or serious pump seal damage could result. 4. Check waste drain line to ensure that water is draining properly and that there are no water leaks. 5. Check vacuum gauge to ensure that the pump is functioning properly. Vacuum relief is factory preset for 10 inches Hg (34 KPa) Vacuum. 6. Store this installation manual for future reference. G. Vacuum Level Adjustment The Vacuum level is adjustable in the range of 8 to 13 inches Hg (27 to 44 KPa). 1. Remove filter and valve from the PVC elbow. 2. Using a 1/2 inch flathead screwdriver adjust the center mounted screw within the valve. Each full clockwise turn increases the vacuum level by approximately 2.5 inch Hg. Vacuum Gauge Filter Cap Relief/ Regulator Filter Vacuum Relief Regulator Valve (Must be removed to adjust) Gasket Screen Filter Bowl ETL LISTED CONFORMS TO UL STD 60601-1 CERTIFIED TO CAN/CSA C22.2#601.1 To Order Call Lions Dental Supply 951-276-3225 Page 7