A Study on Cooling Rate with Blade and Sound Fire Extinguisher

Similar documents
A Study on a Suitability of Sound Fire Extinguisher in Duct Environment

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Study on the Effects of Learning by Changing the Color- Temperature LED Lamp

Comparative study of the conventional and optical communication analog fire detector signal attenuations with various number of fire detectors

Hot Air-Microwave Combined Drying Characteristics of Gypsum Board. Won-Pyo Chun, Sung-Il Kim, and Ki-Woo Lee 1

Development of Smart Phone Applications Linked with Fire Alarm Control Panel in Automatic Fire Detection System

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

Development of a Sensing Module for Standing and Moving Human Body Using a Shutter and PIR Sensor

Evaluation of the Reduction of Rainwater Runoff from a Green Roof

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Visual analysis on the nightscape lighting for the pedestrian and greenery zone of a neighborhood park

DAYLIGHTING PERFORMANCE ON VENETIAN BLIND FOR HEALTHY APARTMENT HOUSING

Upward Evacuation Experiment for Estimating Evacuation Speed in Water Disaster

Modified geotextile tube a new geotextile tube for optimized retaining efficiency and dewatering rate

A Study on the 2-D Temperature Distribution of the Strip due to Induction Heater

Development of a Slope Stability Program for Transmission Towers

An experimental study of the impact of tunnel suppression on tunnel ventilation

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Fire Detection Using Image Processing

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

A Survey on the Sense of Fire Safety and Evacuation Guide System

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

Development of magnetic pulse crimping process for highdurability

Numerical Analysis of the Bearing Capacity of Strip Footing Adjacent to Slope

Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Evaluation on Combustion Characteristics of Finishing Materials for Exterior Walls

Drink Showcase Equipped with Inverter Freezer

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

Solar Drying Techniques And Performance Analysis: A Review

[Patil* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

The Experimental Study and Simplified Model of. Water Mist Absorbing Heat Radiation

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

A Design of IADSS with the Earthquake Detecting Function

Optimization of Sensitivity Characteristics of Photoelectric Smoke Detector to Various Smokes

American International Journal of Research in Science, Technology, Engineering & Mathematics

Range Dependent Turbulence Characterization by Co-operating Coherent Doppler Lidar with Direct Detection Lidar

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

A study of Transient Performance of A Cascade Heat Pump System

Experimental Study on Utilization of E -Waste in Cement Concrete

Long-distance remote simultaneous measurement of strain and temperature based on a Raman fiber laser with a single FBG embedded in a quartz plate

Research on Mobile Water Spray Device Reducing the Temperature of Metro Fire

Design and performance evaluation of vacuum cleaners using cyclone technology

TRANSMISSIVITY BEHAVIOR OF SHREDDED SCRAP TIRE DRAINAGE LAYER IN LANDFILL COVER SYSTEM *

Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal Blower Nitin S. Jadhav *, S. R. Patil

Dynamic Evacuation Guidance Considering Occupant Distribution

COMPARISON OF SHEAR STRENGTH PARAMETERS OF BLACK COTTON SOIL WITH EFFECT OF RELATIVE COMPACTION

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Optical Time Domain Reflectometry (OTDR)

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV)

Introductive seminar International Workshop_atelier/terrain

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

An Analysis of Compartment Fire and Induced Smoke Movement in Adjacent Corridor

International Gas Union Research Conference Limitation of detection range in guided wave testing of buried pipeline

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

THE EFFECT OF HIGH TEMPERATURE AIR DRYING ON EVAPORATION, RUNNABILITY AND COATED PAPER PROPERTIES. Pertti Heikkilä and Pasi Rajala

Study of Soil Cement with Admixture Stabilization for Road Sub-Grade

Effect of Relative Humidity on Oven Temperature of Locally Design Solar Carbinet Dryer

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Exercise 8: Soil Compaction. CE337, Section 006, Team 3. Experimental data acquired on April 16, 2015 by:

Virtual Boundary System Using Passive Infrared Sensor

Department of MCE, Islamic University of Technology 2. Abstract

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Connect North and South Korean Separated Families Higher Comfort Lower Energy

Fire Suppression Performance of Manually Applied CAF and Other Water Based System

Corn drying experiments by pilot dryer

6340(Print), ISSN (Online) Volume 4, Issue 2, March - April (2013) IAEME AND TECHNOLOGY (IJMET)

Control Method Of Circulating Refrigerant Amount For Heat Pump System

A study on performance improvement of corrugated type total heat exchanger considering the structure of flow passage on surface

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

PERFORMANCE OF EARTH TUBE HEAT EXCHANGER COOLING OF AIR A REVIEW

Design of a high accuracy non-dispersive Infrared gas sensor for continuous emission monitoring of carbon monoxide emitted from an industrial stack

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

COASTAL ENGINEERING 2014

Developing a railway station safety control automation system

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

EXPERIMENT NO. III AIR ENTRAINMENT INTO AN IRS DEVICE

Heyam Daod. Keywords Fine-grained soils, liquid limit, microwave drying, moisture content

Experimental Study of Initial Process of Frost on Heat Exchanger Surface of Refrigerated Transport Vehicle

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

SCALE MODEL STUDIES ON SMOKE MOVEMENT IN INCLINED TUNNEL WITH LONGITUDINAL VENTILATION AND SMOKE BARRIERS

A Simple Design To Access Additional Energy From Real Resources

A Study on Hierarchy of Spatial Configuration in Outpatient Department of General Hospital

COOLING ENERGY SAVING SYSTEM USING A WATER MIST DEVICE ON WINDOWS

Influence of Different Materials to Improve the Stabilization of Black Cotton Soil

Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Transcription:

International Journal of Engineering Research and Technology. ISSN 0974-3154 Volume 11, Number 12 (2018), pp. 1969-1976 International Research Publication House http://www.irphouse.com A Study on Cooling Rate with Blade and Sound Fire Extinguisher Bong-Young Kim 1 1 Department of Information and telecommunication Engineering Soong-sil University, Seoul, Korea 1 Orcid Id : 0000-0002-3553-039X Myung-Jin Bae 2 * 2 Department of Information and telecommunication Engineering Soong-sil University, Seoul, Korea 2 Orcid Id : 0000-0002-7585-0400 (*Corresponding author: Myung-Jin Bae, Professor.) ABSTRACT Since the Industrial Revolution, human civilization has developed rapidly and the buildings have become skyscrapered and their interior has become very complicated. A new conflagration suppression method is needed to suppress or prevent conflagration in various environments due to the change of fire fighting environment. Sound Fire Extinguisher, which is actively studied at Sori Sound Engineering Research Institute (SSERI), is a new type of extinguishment facility that can be used for suppression and prevention of conflagration in various environments. Sound Fire Extinguisher uses acoustic lens to minimize the attenuation of sound energy and transfer energy to the target point. It can prevent conflagration by lowering ambient temperature even before conflagration. In this study, we experimented to see if the Sound Fire Extinguisher could prevent conflagration by lowering the ambient temperature. Experimental results show that when the Sound Fire Extinguisher sound component of the same wind speed is supplied, the heated tableware is cooled by 10 ~ 20% faster than the wind speed of 2m/s. These results show that the Sound Fire Extinguisher can be used to prevent conflagration, since the sound component of the Sound Fire Extinguisher itself promotes the surrounding thermal dissipation to cool quickly. Keywords: Conflagration, Sound Fire Extinguisher, Acoustic Lens, Sound Component, Cooling

1970 Bong-Young Kim, Myung-Jin Bae I. INTRODUCTION Human civilization has developed rapidly since Industrial Revolution. With the development of human civilization, buildings and their internal structures became skyscrapered and complicated. The conflagration suppression method should also be changed due to the changed fire fighting environment. Conventional conflagration suppression methods are mostly spraying a large amount of water directly to the conflagration field to lower the temperature or spray the extinguishing agent to block oxygen. However, this method is a countermeasure that can be taken when conflagration has already occurred and is causing damage. In addition, the spraying of water or extinguishing agent alone will destroy the information telecommunication infrastructure and other equipment. For these reasons, conflagration suppression method with suppressive function or preventive function is required in various environments [1-2]. Sori Sound Engineering Research Institute (SSERI) is actively researching Sound Fire Extinguisher which can be used to suppress and prevent conflagration in various environments. The Sound Fire Extinguisher was first introduced in the US Defense Advanced Research Projects Agency (DARPA), where low frequency sounds resonate with flame molecules to affect extinguish, and furthermore SSERI is being developed for use in real fire fighting environments. Sound Fire Extinguisher suppresses conflagration by using a sound component that is not water or extinguishing agent, so it can minimize the damage of various equipment such as information telecommunication infrastructure and can be fully used as a preventive even before conflagration occurs. In particular, by applying an acoustic lens to the Sound Fire Extinguisher, the sound component is collimated to one side to eradicate it, thereby enhancing the extinguishable efficiency and maximizing various effects of the sound. Figure 1 is a portable Sound Fire Extinguisher under study at SSERI [3-7]. Fig 1. Portable Sound Fire Extinguisher In this paper, we compared the cooling rate of the blade and Sound Fire Extinguisher to check if the sound component of Sound Fire Extinguisher can prevent conflagration by lowering ambient temperature before conflagration occurs. In Chapter 2, the sound fire extinguisher sound component collimation using the acoustic lens is explained. In Chapter 3, the experiment and the result are discussed. Chapter 4 concludes.

A Study on Cooling Rate with Blade and Sound Fire Extinguisher 1971 II. SOUND FIRE EXTINGUISHER'S SOUND COMPONENT COLLIMATION BY ACOUSTIC LENS Acoustic Lens: An acoustic lens is a device that focuses or collimates sound energy. In general, sound emits the same energy in all directions, so the propagated form becomes spherical. Therefore, when the propagation distance is doubled, the propagation area is quadrupled and the propagated energy is reduced to 1/4. An acoustic lens is placed on the path of sound propagation to focus sound energy. Sounds are refracted at the interface of different mediums like other types of waves. When an acoustic lens with radius of curvature R is installed in front of the oscillator, the distance F at which the sound is focused can be approximated as shown in equation (1). Figure 2 is a schematic of an acoustic lens [8-11]. R : Radius of curvature of acoustic lens F : Distance to focus n : Sound velocity ratio between medium1(acoustic lens) and medium2 (1) Fig 2. Schematic of Acoustic Lens Sound Fire Extinguisher s Sound Component Collimation: The point where the sound energy is concentrated through the acoustic lens is called focus. When a sound source is placed at the focus of an acoustic lens, the sound wave passing through the lens becomes a plane wave that transfers energy to a certain area. Sound Fire Extinguisher uses a special acoustic lens to collimate a sound component so that it propagates as a plane wave. Thus, in the case of a Sound Fire Extinguisher, the sound passing through the acoustic lens minimizes attenuation and can transfer energy to the flame. Generally, in the sound field, the wind speed is not formed because the low density part and the high part of the medium particle repeatedly change and the wave is transmitted. However, Sound Fire Extinguisher uses acoustic lens to collimate the

1972 Bong-Young Kim, Myung-Jin Bae sound energy, so the variation of medium particle density becomes very large and wind speed is formed. The portable Sound Fire Extinguisher used in the experiment has a wind speed of about 10m/s at a distance of 10cm [8-11]. III. EXPERIMENTS AND RESULTS Experiments were carried out to measure the temperature change from 100 by heating stainless steel tableware. The experiment was conducted in three cases: first, the temperature change was measured with natural cooling; second, when the blade was blowing; and third, when the sound component of the Sound Fire Extinguisher was supplied. In order to compare the Blade and Sound Fire Extinguisher under the same conditions as possible, the distance between the blade and the stainless steel tableware is 50 cm, the distance between the sound fire extinguisher and the stainless tableware is 90 cm and the wind speed reaching the stainless tableware is 2 m/s, respectively. The temperature change of the stainless steel tableware was recorded with video using thermal imaging camera FLIROne and Galaxy Note 4. The temperature was measured at the same position inside the tableware for each experimental cycle. The experimental environment is shown in Figure 3. Fig 3. Experiment Environment At the time of the experiment, depending on the experimental environment such as the ambient temperature, it may affect the rate of cooling the stainless tableware. In addition, measurement errors may occur depending on the location of the thermal imaging camera. Therefore, in order to compare the measured results under the same environmental conditions for each experimental cycle, all the experimental tools were fixed so that the temperature measurement positions could be the same. Also, in each experimental cycle, one experimental cycle was completed within 30 minutes to simulate the ambient temperature. The comparison between different experimental cycles is meaningless because the experimental environment including the ambient

A Study on Cooling Rate with Blade and Sound Fire Extinguisher 1973 temperature is different and the temperature measurement position is slightly different. However, in the same experimental cycle, it can be said that the result is comparative measurement under the same condition. The actual experiment scene and temperature measurement screen are shown in Figure 4. Fig 4. Experiment scene and thermal image recording screen Figure 5 is a graph of the experimental results of Figure 4. Figure 5 shows the comparison of measured temperature changes when natural cooling, wind of the blade are supplied, and sound components of the Sound Fire Extinguisher are supplied. In Figure 5, it took 82 seconds to cool the stainless tableware by natural cooling from 100 C to 50 C, and it took 33 seconds when the wind of the blade was supplied. However, when the sound component of Sound Fire Extinguisher was supplied, it took 22 seconds and the temperature decreased more rapidly. Fig 5. Temperature change measurement result

1974 Bong-Young Kim, Myung-Jin Bae The experiment as shown in Figure 4 and Figure 5 was performed 8 times in total. Table 1 shows the results of measuring the cooling time of the stainless tableware for each experimental cycle. The results of Table 1 show that the supply of wind of the blade to heated tableware was cooled more rapidly than that of natural cooling. However, if the sound component of the Sound Fire Extinguisher is supplied to the heated tableware, it will cool more quickly than when the wind of the blade are supplied. Especially, all of the eight experiments showed that the cooling effect of the Sound Fire Extinguisher's sound components was the best. In addition, the results of the whole experiment showed that the sound component of the Sound Fire Extinguisher was cooled 10 ~ 20% faster than when the wind of the blade were supplied. Table (1) Experimental results (measurement of the time required for temperature reduction) Temperature reduction time (sec) Experimental cycle 100 90 100 80 100 70 100 60 100 50 1 st Natural cooling 8 19 33 47 71 Blade 4 8 13 19 28 Sound Fire Extinguisher 4 7 12 18 26 2 nd Natural cooling 11 23 35 56 82 Blade 5 10 17 24 33 Sound Fire Extinguisher 3 7 11 16 22 3 rd Natural cooling 10 23 37 56 80 Blade 4 8 13 20 30 Sound Fire Extinguisher 4 8 13 19 27 4 th Natural cooling 11 23 38 57 83 Blade 5 9 15 22 33 Sound Fire Extinguisher 4 8 13 19 28 5 th Natural cooling 11 24 40 57 83 Blade 4 9 15 22 32 Sound Fire Extinguisher 4 8 13 19 27 6 th Natural cooling 8 21 34 50 77 Blade 5 10 16 23 35 Sound Fire Extinguisher 4 8 12 19 26 7 th Natural cooling 9 20 30 47 78 Blade 6 12 17 24 33 Sound Fire Extinguisher 5 9 15 23 34 8 th Natural cooling 10 20 33 50 77 Blade 5 9 15 22 32 Sound Fire Extinguisher 4 8 13 20 29 Average Natural cooling 10 22 35 53 79 Blade 5 9 15 22 32 Sound Fire Extinguisher 4 8 13 19 27

A Study on Cooling Rate with Blade and Sound Fire Extinguisher 1975 IV. CONCLUSION Conventional conflagration suppression method is mostly spraying water or extinguishing agent in conflagration field. However, since the building is skyscrapered and its interior is also very complicated, a new method of conflagration suppression method applicable to various environments is needed. Sound Fire Extinguisher, which is being actively studied at SSERI, is a new extinguishing facility that can be applied to various fire fighting fields. In this study, we tried to confirm the cooling effect of Sound Fire Extinguisher by comparing with blade. As a result of experiment that the wind speed reaching to the stainless tableware is 2m/s, the Sound Fire Extinguisher's sound component was found to cool the stainless tableware by 10 to 20% faster than when the wind of the blade were supplied. The wind of the blade simply lowers the heat by moving the air around the tableware. On the other hand, the sound component of the Sound Fire Extinguisher can be said to cool more quickly because it dramatically changes the air density around the tableware to promote heat diffusion. These results show that Sound Fire Extinguisher has a high cooling effect even at the same wind speed and can be used for conflagration suppression as well as conflagration prevention. In addition, the Sound Energy Extinguisher's special acoustic lens collimates the sound energy, so we can see that the sound energy is well transmitted to the target point. Sound Fire Extinguisher will be able to produce various effects depending on the sound component. Future applications of Sound Fire Extinguisher for various purposes have been studied, and we hope to be able to use Sound Fire Extinguisher in various applications in fire fighting field. REFERENCES [1] K. M. Jung. Fire Protection Theory, DongHwa Technology, Korea (2017). [2] I. B. Kim, et. Fire suppression agents, DongHwa Technology, Korea (2017). [3] DARPA 2012.07:: http://www.extremetech.com/extreme/132859-darpacreates-sound-based-fire-extinguisher [4] George Mason University youtube:: https://www.youtube.com/watch?v =upvqmz4ikvm. [5] Bong-Young Kim, Myung-Jin Bae, Seong-Geon Bae, "A Study on a Suitability of Sound Fire Extinguisher in Duct Environment", International Journal of Applied Engineering Research, ISSN 0973-4562, Vol.12, No.24, pp.15796-15800, 2017. [6] Bong-Young Kim, Eun-Young Yi, and Myung-Jin Bae, "A Study on the Effect of Sound Fire Extinguisher on Extinguishment by Smothering", Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology, Vol.8, No.6, pp.765-772, June 2018. [7] HyungWoo Park, and Myung-Jin Bae, "Waveform Analysis and Enhancement

1976 Bong-Young Kim, Myung-Jin Bae for Efficiency Improvement of sound wave extinguisher", Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology, Vol.8, No.6, pp.755-764, June 2018. [8] [http://terms.naver.com] Acoustic lens (Doopedia, DOOSAN Corporation) [9] S. T. Lee. Principles and Application of Sound, Cheong Moon Gak, Korea (2004). [10] Jo-cheon Choi, Sang-Hoon Kim, Seong Ro Lee, "Development of Next Generation Sonar by Acoustic Lens", The Journal of Korean Institute of Communications and Information Sciences, Vol.39, No.12, pp.1318-1322, December 2014. [11] Ik-Soo Ahn, Myung-Jin Bae, "A Study on a Sound Fire Extinguisher using Special Sound lens". Annual Conference of the Korean Institute of Communication Sciences, pp.850, January 2016.