Quadruple-beam photoelectric detector

Similar documents
Photoelectric Beam Detector

Twin Photobeam Detectors Manual

CAUTIONS ON INSTALLATION

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Description. Optex Incorporated

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

1 PRODUCT COMPONENTS This section describes the contents of the product package and the names and functions of

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

PHOTOELECTRIC BEAM SENSOR PB- 50HFA-KH PB-100HFA-KH PB-200HFA-KH

PHOTOELECTRIC DETECTOR

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

INFRARED MODULATED BARRIERS

PHOTOELECTRIC DETECTOR

English. Series. Installation and Use Manual

Long-Range Barrier Sensors

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

ITALIANO BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL. Manuale istruzioni BST-100. Pag.

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

2 General Application Photoelectric Sensors

Installation And commissioning manual. Series S Double Beam 1/16

Reflective Optical Beam Smoke Detector User Guide

2 General Application Photoelectric Sensors

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Contents. Photoelectric Sensors / Standard Sensors...4. Safety Sensors Photoelectric Sensors / Miniature Sensors... 12

English. Italiano. Português. Françias. Español

EXTRA WIDE ANGLE ARRAYS EWA 0.3 GI V1 EWA 0.53 GI V1 EWA 1.35 GI V1 ANIMAL ALLEY ARRAYS AA 0.53 GI V1 AA 0.53 GI M1 AA 0.9 GI M1.

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

AX-70TN, AX-130TN, AX-200TN AX-100TF, AX-200TF

Movement Detector GJD 300

Hardwired Alarm Accessories

Wireless PIR Sensor with Transmitting Distance:300~500m

Active Infrared Multi Beam Sensors

5.0. Photoelectric Sensors. Technical Reference. Introduction

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

Active Infrared Multi Beam Sensors. R Series

General Purpose Photoelectric Sensor

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

General Specifications. Small size Fast 500µs response time Cable or quick-disconnect options 11 28V DC Operating Voltage Red output LED indicator

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

Fact File 66. Guide to Beam Smoke Detectors

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

PHOTOELECTRIC BEAM SENSOR

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

SECURITY PRODUCTS CATALOGUE

CONFIGURATION OF THE OPTICALS

Installation and Operation Manual

"Pegaso" wireless alarm system

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

P E R I M E T E R m i n i c a t a l o g u e

VISAGE ENVIRONMENTAL LIGHTING SOLUTION. INDOOR Lighting SERIES

Pyroelectric Infrared Sensor PIR

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

The Affordable, All-Purpose Sensor That's EZ To Use!

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

COMPACT FLAME CONTROLLER CFC 2000

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Open-area Smoke Imaging Detection (OSID)

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

TITLE SLIDE FIRERAY50/100R OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

/ / 2018

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

FIREYE C9707A ALL FUEL SCANNER

2 Specialty Application Photoelectric Sensors

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

REDNET INFRARED BEAM SET TYPE RN4/10-25, RN4/25-75 & RN4/ INSTALLATION AND SET UP INSTRUCTIONS

D-TECT Dual Tech. GJD360 Triple Technology External Detector

Open-area Smoke Imaging Detection (OSID)

COMPACT FLAME CONTROLLER CFC 1000

Advanced DIGITAL Wired PIR Motion Detector

DUAL OPTIC. Installation manual

Increased safety and reducing energy consumption with the motion control RPI 01

PARVIS Safe and tranquil thanks to Parvis

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Class 1 laser beam sensor safe for your eyes

Emerald 3000 MK3 GJD010 Lighting Controller

Photo Beam 5000/3000 Series Heater. en Installation Guide

D-Tect 2 GJD300 Quad PIR Movement Detector

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control

ACTIVE INFRARED PERIMETER DETECTION BEAMS & ENCLOSURES

Infrared Sensors Line Guide

INDEX. Installation recommendation

Extreme High-Intensity Sensors Thru-Beam and Fiberoptic Penetrates Many Packaging Materials for Content Verification

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

ADPRO PRO Passive Infrared Detector. Webinar November Ben Klösen, PLM

Intelligent addressable fire alarm control panel

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

EEM 451 Industrial Control Systems Sensors and Actuators-II. Dept. of Electrical-Electronics Eng. Anadolu University, Turkey

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

Table of Contents. 1. Mounting Tips... 2

Transcription:

New generation 4-channel selectable frequencies abh-50/100/150/200/250m Quadruple-beam photoelectric detector Highly Reliable Photoelectric Detector ABH series quadruple-beam photoelectric detector with "4-channel selectable frequencies" avoid unwanted crosstalk that can occur when using multiple photobeam over long distances or for beam stacking applications.

Anti-white light lens design Strong sun-light will impact performance of photoelectric detector, since it can interfer IR reception. Beside using anti-uv plastic cover, photoelectric receiver adopts dual lens with anti-white light coat to effectively filter white light, which in turn, provide you 99% reliable detection. Extremely durable Infrared sources Utilizing high power military grade Infrared emitting diode to ensure transmission range and stability of sensor, it has much longer lifespan than conventional IR LEDs in market. Digital signal processing unit The circuit design includes a digital processing unit (MCU) to process digital signal, it can provide higher accurate detection and reliability than conventional photoelectric detectors which usually adopt simple logic circuit design. Heater connection ready design New generation ABT series photoelectric beam added support of smart heating control, users can easily connect a heater to detector, by using heater the detector can effectively de-frost and enable it work under extreme cold weather conditions. Easy&fast installation with LED display Offering easy and fast installation, because it has unique LED segment display can show signal level by using digital number, greatly help installers to align receiver and transmitter easily, 0-4 means weak, 5-6 low, 7-8 good, 9 best. High grade spherical lens The high grade spherical lens creates more sharply defined & precise infrared beams compared to ordinary fresnel lenses. Easy angle adjustment It allows the installer to finely adjust the beam easily. [ Horizontally ±90 with hand ] [ Vertically ±5 with screwdriver ] A.G.C. (Automatic Gain Control) Circuit A.G.C. circuit continually monitors for gradual changes in the signal's strength caused by changing weather conditions. It adjusts the sensitivity accordingly to maintain the proper signal level for the current environmental conditions 4CH selectable frequencies ABT series photoelectric detector adopts industryleading selectable frequencies technology, has completely solved crosstalk interference under stacking or long distance other sophisitcated installation conditions.

photoelectric beam detector most reliable outdoor perimeter Protection

example installation The selectable frequency can avoid crosstalk for long distance or stacking use. Make sure the transmitter and receiver with the same frequency, although there are 4 channel frequency can be chose, please set frequency two channels apart for stacking applications.

technical parmater Model ABH-50M ABH-100M ABH-150M ABH-200M ABH-250M Number of Beams Quadruple (4) Detection Range outdoor: 50m outdoor: 100m outdoor: 150m outdoor: 200m outdoor: 250m indoor: 100m indoor: 200m indoor: 300m indoor: 400m indoor: 500m Beam Angle 1.6m 2.6m 2.6m 3.4m 4.4m Light Sources Digital Filter Type Frequency channel 4-channel selectable frequencies Detecting method Triple infrared beams are interrupted simultaneously Sensor Speed Variable between 50, 100, 250, 500 msec (4 steps) Alarm Output Relay Output Contact Rating: AC DC 30V 0.5A Max Current Sinking 90mA Max Using Temperature -25 Celsius degree - 60 Celsius degree Dismantle Prevention Output Relay Output Contact Rating: AC DC 30V 0.5A Max Adjusting Angle of Optical Axis (Horizontal) 180 ±90 Adjusting Angle of Optical Axis (Vertical) 24 ±10 Hairline Pointer Window Type Connection M3 Connection Assistance Spiral Terminal Dedew and Defrost method Built-in heating controlling design Other Function Induction Testing Output Terminal Warranty 12 months factory warranty Material PC engineering plastic/resin Weight 2500g optional accessories Product dimension Stainless Steel Pole Length: 30cm / 50cm; Type: L / I shape Heater Voltage: 12V - 24V DC Current: 350mA max Temperature: 60 celsius degree Dimension: PA2.5*10mm www.unifore.net