RELIANCE ENDOSCOPE PROCESSING SYSTEM (For Use In EUROPE Only)

Similar documents
RELIANCE EPS ENDOSCOPE PROCESSING SYSTEM (For Use In U.S.A. Only)

RELIANCE 400 LABORATORY GLASSWARE WASHER

RELIANCE VISION SINGLE-CHAMBER WASHER/DISINFECTOR

RELIANCE 444 SINGLE-CHAMBER WASHER/DISINFECTOR

AMSCO V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEM (For Use Outside U.S.A. Only)

RELIANCE 680PG PHARMACEUTICAL GRADE WASHER

RELIANCE 580 PHARMACEUTICAL GRADE WASHER

BASIL 6700 TUNNEL CAGE WASHER

BASIL 9502 CAGE AND RACK WASHER

BASIL 6000 TUNNEL CAGE WASHER

VHP ARD BIODECONTAMINATION SYSTEM

VISION 1321/1327 CART AND UTENSIL WASHER/DISINFECTOR

HARMONY LED385 EXAMINATION LIGHTING SYSTEM

HAMO T-420 PHARMACEUTICAL GRADE WASHER SIEMENS PC CONTROL

VHP M100 BIODECONTAMINATION SYSTEM

Introducing The Reliance 200 and 250 Glassware Washing Systems.

SOLUSCOPE SERIES 3 DESIGNED WITH THE FUTURE IN MIND FEATURES FLEXIBLE ENDOSCOPE DISINFECTOR / STERILISER

G 7804 Laboratory Glassware Washer. Simplified Control, Miele Quality

Lower Your Costs. Expand Your Flexibility.

G 7883 CD Laboratory Glassware Washer. Analytical Cleaning, HEPA-Filtered Drying

Lower Your Costs. Expand Your Flexibility.

CER-1 & CER-2 Installation & Testing Instructions

VS LD series vertical steam sterilizers

AS950 REFRIGERATED SAMPLERS

G 7883 Laboratory Glassware Washer. Analytical Cleaning, Compact Design

2015 Myco Industries, Inc Fax:

TECHNICAL SPECIFICATIONS FOR PLUSHER WDC 8 SERIES INSTRUMENT WASHER DISINFECTORS

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 12 SERIES INSTRUMENT WASHER DISINFECTORS

AMSCO CENTURY MEDIUM STEAM STERILIZER 26 X 26" (SCIENTIFIC)

Customer Requirements Pre-Installation Instructions

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 18 SERIES INSTRUMENT WASHER DISINFECTORS

SITE REQUIREMENTS & INSTALLATION DSD-201 & SSD-102

The Reliance 400/500 Glassware Washers

DC200 Digital Dispenser Operating Manual

AMSCO CENTURY MEDIUM STEAM STERILIZER 26 X 37.5" NORTH AMERICA

FlaskScrubber & SteamScrubber Laboratory Glassware Washers

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

A new wave in automated instrument washing. Introducing the new HYDRIM G4 series

VHP ARD Mobile Biodecontamination System

FlaskScrubber & SteamScrubber. Laboratory Glassware Washers NEW! FlaskScrubber & SteamScrubber racks now interchangeable

AMSCO REMANUFACTURED MEDIUM STERILIZERS

LOGIC CONTROLLED DEKO 25 EASE OF USE

Site Requirements ADVANTAGE PLUS

DEKO 190 Ward washer-disinfector

AZTECA A LITRE STERILISER

A new wave in automated instrument washing and disinfection Introducing the new HYDRIM G4 WD series

Version 7 1/ LXP

MODEL 7000 SUCTION UNIT

VHP M100 Biodecontamination Systems: Closed Loop

GIRTON CABINET WASHER MODEL 794A

9100 SERIES FLOOR LOADING CART & UTENSIL WASHER/DISINFECTOR

WORLD LEADERS IN ADVANCED SURGICAL INSTRUMENT REPROCESSING TECHNOLOGY

AMSCO CENTURY MEDIUM STEAM STERILIZER 26" X 37.5" (SCIENTIFIC)

AMSCO CENTURY SMALL STERILIZERS DOMESTIC

Site Requirements. MODEL 2.0 Australia

Version 7 1/ LX

FLASH PAK STERILIZATION CONTAINER SYSTEM

AMSCO EVOLUTION STEAM STERILIZERS - NORTH AMERICA

Sterilizer Model LS2020 Series Beta Star Life Science Products of R-V Industries

AUTOMATIC STERILIZERS

A new wave in instrument washing and disinfection Introducing the HYDRIM G4 WD series

Screw Compressors SM SERIES. Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig

Open the Door to Increased Productivity and Cost Efficiency

STERIS Instrument Cleaning Chemistries

VWR symphony CO 2 INCUBATORS

Getinge 8666/8668 Washer Disinfectors

GIRTON TREE, TUB, AND CART WASHER MODEL 80-O

Rhima Deko 190 Washer-disinfector for human waste containers

Tramp Oil. Removal Equipment Equipment designed for removing oil from water based fluids ERIEZ. ...Only from Eriez. Tramp Oil. Removal Equipment:

SENTRA Series Water Unit

IQ/OQ Protocol Installation Qualification/ Operation Qualification

Application Equipment

Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

A new wave in instrument washing and disinfection Introducing the new HYDRIM c61wd G4 series

VENTLESS DOOR-TYPE DISHWASHER

Screw Compressors AS SERIES. Capacities from: 59 to 124 cfm Pressures from: 80 to 217 psig

LAB DIVISION. WASHING & DRYING cglp Process Equipment for Research and Microbiological Laboratories

AS950 PORTABLE SAMPLERS

ENDOSCOPE DECONTAMINATION : Where are we now!

The Hydrim C51wd Washer Disinfector. Perfectly prepares instruments for sterilisation in as little as 19 minutes.

DEKO 25 washer-disinfector

PG 8535 Perfect Reprocessing

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

G 7825 Laboratory Glassware Washer. Compact Design, High Throughput

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

Cleaning & Sterilization

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

AccuBrine automated brine maker Technical Specifications

The future is bright. And clean. And fully automated.

Flexible endoscope automated reprocessing system

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

AMSCO Washer-Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

DEKO 260 Washer - Disinfector - Dryer

HYDRIM. Powerful cleaning the first step to effective sterilization. Instrument Washers A HIGHER STANDARD

Freeze Dry Systems and Accessories

Accessible. Durable. Smart.

Prolystica Ultra Concentrate Instrument Cleaning Chemistries Now less is more. NEW generation instrument cleaners

Transcription:

RELIANCE ENDOSCOPE PROCESSING SYSTEM (For Use In EUROPE Only) APPLICATION The Reliance Endoscope Processing System is an economical, easy-to-use high level disinfection system that can clean and high level disinfect up to two manually pre-cleaned, immersible, reusable, heat-sensitive, semi-critical devices such as GI flexible endoscopes and related accessories. The system utilizes Reliance HLD High Level Disinfectant, a proprietary, safe, dry peracetic acid-generating germicide. The Reliance Endoscope Processing System was designed to be versatile in meeting the growing demands of the modern flexible endoscope-processing department, while offering the highest level of patient and staff safety. The Reliance automated process offers the quality and the service you have come to expect and rely on from STERIS. The Reliance Endoscope Processor is intended to be used solely with the Reliance HLD High Level Disinfectant and Verify Process Indicator for Reliance EPS. The Reliance HLD is a proprietary, two-part, dry, single-use germicide, designed to generate the high level disinfectant solution in the Reliance Endoscope Processor. Only use (Typical only some details may vary.) Reliance HLD High Level Disinfectant in the Reliance Endoscope Processor. Do not substitute any other product for the Reliance HLD High Level Disinfectant. The Verify Process Indicator strips are qualitative chemical indicators of the presence of the Reliance HLD active ingredient (peracetic acid). Only use Verify Process Indicator strips for the qualitative detection of the presence of peracetic acid in the Reliance Endoscope Processor. The Selections Checked Below Apply To This Equipment VOLTAGE 230 V, 50 Hz, 1-Phase 400 V, 50 Hz, 3-Phase CONSUMABLES Reliance HLD High Level Disinfectant Verify Process Indicator for Reliance EPS Klenzyme Enzymatic Presoak and Cleaner CIP 200 Formulated Acid Cleaner ACCESSORIES Bar Code Reader Seismic Anchorage Kit Installation Kit: 230 V, 50 Hz, 1-Phase 400 V, 50 Hz, 3-Phase Language Package: French Spanish German ACCESSORIES (Cont d) IQ/OQ/PQ Validation Package Reliance Challenge Kit Automated Leak Test for Olympus, Pentax and Fujinon Endoscopes Dual Pre-Filter and Regulator Assembly* Flow Unit 1 for Irrigation Tubes Flow Unit 2 for Olympus 145/160/165/180 Series GI Endoscopes 1 Flow Unit 3 for Pentax Water Jet P/X/00/01 Series GI Endoscopes 1 Flow Unit 4 for Pentax 70/70K/72/72K80K/81K/ 85/85K/90i/90K Series GI Endoscopes 1 Flow Unit 5 for Cook, Medovations and CONMED Lumened Dilators (See Table 3 for Model Numbers) ACCESSORIES (Cont d) Leak Test Hose for Olympus Leak Test Hose for Pentax Leak Test Hose for Fujinon * This accessory must be ordered for each processor. 1 Registered trademarks of Olympus Optical Co., Ltd., Pentax Imaging Company, and Fujinon Inc. Item Location(s) SD819 (03/01/11)

DESCRIPTION The Reliance Endoscope Processor is single door and designed as a freestanding unit (with accessory countertop and panels). A drop-down door facilitates the loading of the unit. The processor features a state-of-the-art microcomputer control system with a user-friendly operator interface. The processor is preprogrammed with six complete standard cycles: SINGLE for one endoscope with or without a cleaning phase, DOUBLE for two endoscopes with or without a cleaning phase, D-SHORT and D-LONG. A standard printer records important in-cycle, alarm and cycle value data. A bar code reader (see ACCESSORIES) can be installed to print identification numbers for the Operator ID, Patient ID, Device ID, Procedure ID and Physician ID. Reliance HLD High Level Disinfectant. A dry, single-use, high level disinfectant for use in the Reliance Endoscope Processor. It is used to high level disinfect manually pre-cleaned, immersible, reusable, heat-sensitive, semi-critical devices such as GI flexible endoscopes, bronchoscopes and related accessories. Verify Process Indicator for Reliance EPS. Developed exclusively for the independent monitoring of the Reliance HLD High Level Disinfectant used in the Reliance Endoscope Processor. The Verify Process Indicator is a qualitative chemical indicator (i.e., process indicator) used to indicate the presence of the active ingredient of the Reliance HLD High Level Disinfectant. Klenzyme Enzymatic Presoak and Cleaner. Single enzymebased detergent for surgical instruments, flexible endoscopes and other medical apparatus used in healthcare facilities. This product is provided in a special Bag-in-a-Box container developed to ease handling and installation. CIP 200 Formulated Acid Cleaner. A liquid, acidic detergent system specially formulated to meet unique cleaning demands. In the presence of heat it helps to remove a wide range of process residues, from inorganic salts to particulate carbon. This product is provided in a special Bag-in-a-Box container developed to ease handling and installation. Exterior Dimensions (W x D x H) 965x 825x 1121 mm (38 x 32-1/2 x 47-11/16") Interior Chamber Dimensions (W x D x H): 610 x 483 x 584 mm (24 x 19 x 23") Loading Height: 607 mm (23-15/16") with drop-down door open. STANDARDS The processor meets the applicable requirements of the following standards: Underwriters Laboratories (UL) Standard 61010-1 2005. Canadian Standards Association (CSA) CAN/CSA22.2 No. 61010-1, 2nd ed. ISO/DIS 15883-1: Washer-Disinfectors general requirements, definitions, and tests. ISO/DIS 15883-4: Washer-Disinfectors, using chemical disinfection for thermolabile endoscopes, requirements and tests. Governing Directive for the affixing of the CE mark: Medical Device Directive 93-42-EEC as amended by 2007-47-EC. Standards applied to demonstrate conformity to the directives: IEC 61010-1; IEC 61010-2-040; IEC 61326-1. FEATURES Rex Microcomputer. This microcomputer monitors and controls the processor operations and functions. The cycle progresses automatically through the designated phases, as programmed. Double Monitoring. Additional sensors and PC board verify (independent of the main control) critical parameters were successfully achieved during the cleaning wash, HLD and air purge phases. A general PASS or FAIL status and the acceptable ranges along with the recorded maximum and minimum values are printed at the end of the cycle. An audible signal and printout will inform the operator if a deviation from the allowed ranges occurs during a cycle. Front-Loading Drop-Down Door. A front-loading, drop-down door is provided to facilitate loading of the unit. The door is constructed of 316 stainless steel covered with a plastic panel. The panel is strong and easy to clean. A tempered glass window allows the operator to view the chamber interior while a cycle is in progress. Panel and glass window remain relatively cool to the touch. Service Access Panel. The front bottom service access panel provides an easy access to the 0.2 µm bacterial-retentive filter, cleaner injection pumps and other components for maintenance. Interior Fluorescent Light. A 20,000-hour life expectancy interior light allows operator to view process/load during the cycle. An idle mode is used when no cycle is being processed. If no action is taken for five minutes, the interior light turns OFF. If a pushbutton is pressed, an alarm sounds, or the load door closes/opens, then the interior light automatically turns ON again. Bag-in-a-Box Compartment. A three-shelf compartment is provided at the right of the chamber. Each shelf is designed to receive a Bag-in-a-Box container provided with a speciallydesigned connector. The Bag-in-a-Box compartment dropdown door is made of the same easy-to-clean plastic as the chamber door panel. Cleaner Injection Pumps. The peristaltic cleaner injection pumps automatically inject the correct quantity of cleaner during the appropriate cycles. The pumps are conveniently positioned behind the front service access panel for easy maintenance. 2

Endoscope Processing Support. The Endoscope Processing Support is designed to minimize the number of connections required to flow the endoscope channels. The Endoscope Processing Support can process one or two endoscopes and their related accessories. The Endoscope Processing Support includes two Control Handle Boots, labeled "A" and "B", for processing compatible flexible endoscopes. Additionally, each Control Handle Boot can be adapted to process endoscopes that have special processing requirements (e.g., small diameters and no light guide cables). A dedicated Process Indicator Clip on Control Handle Boot A is designed to firmly hold the Verify Process Indicator in place during the cycle. The large mesh basket on the upper level of the Endoscope Processing Support can hold up to two light guide cables and large compatible accessories. When required, flow units can be connected to the two fluid flow ports in the large mesh basket. Bite blocks can be placed on the two accessory pegs. On the lid of the Chemical Delivery System are two templates for measuring the insertion tubes diameters. The small accessory basket and cover is stored under the large mesh basket and is designed to hold small compatible accessories such as air/water valves. The valve irrigators have been designed to hold suction valves during the processing cycle. Valves are held open inside the holder to ensure solution contacts inside valve surfaces. Chamber. The high-quality, stainless-steel chamber is insulated to reduce heat loss and noise level. Four manifold connectors are provided at the back of the chamber: one is the hot water inlet to the Chemical Delivery System, two are connectors for the pressure sensors and one is for the Endoscope Processing Support. The Endoscope Processing Support is automatically connected to these manifold connectors when positioned correctly in the processor chamber. A removable debris screen at the bottom of the chamber prevents large debris from entering the piping system and pump. The screen is provided with a handle and is easily removed for cleaning. 0.2 µm Bacterial-Retentive Filter. All the water supplied to the processor is filtered through a 0.2 µm bacterial-retentive filter which is conveniently positioned behind the service access panel (below the chamber door) for easy maintenance. A pressure hold integrity test during each cycle verifies parameters affecting filtration efficiency remain within specifications. Manifolded Air Purge System. This system circulates HEPAfiltered air through the Endoscope Processing Support and inside the endoscope channels to help remove residual water. The air is purged at room temperature for safe processing. No special air handling or ventilation is required. Non-Vented System. Air charged with humidity is evacuated from chamber through the condenser and returned to the room. Remote Printer. A printer is included with the Reliance Endoscope Processor. The printer allows the operator to print process time, date, and unit malfunction data. Specific information is printed from the Operator mode (cycle parameters, cycle in process parameters, alarms) and Service mode (unit configuration values, unit setup, etc.). The printer can be installed at a convenient location up to 3 m (10 feet) away from the processor. Cup Detection. The Reliance Endoscope Processing System will provide the user with an indication that a new Reliance HLD container has been used for the current cycle. Components of the in-use solution are monitored during the disinfection phase and the control will abort any cycle where a predetermined level is not detected. Validation Entry Port. A threaded plug provides easy access to the chamber to allow insertion of temperature sensors into the chamber for the Operational Qualification (OQ), Performance Qualification (PQ) and routine tests prescribed in the Installation, Operational And Performance Documentation Package (IQ/OQ/PQ) for the Reliance Endoscope Processor (P920501-501). Countertop. The countertop is made of a laminated wood covered with an easy-to-clean solid plastic surface. Air Compressor. The built-in air compressor accessory which will provide the processor with the required 50 psi air supply for 0.2 µm bacterial-retentive filter integrity testing. Also provides for optional Leak Test Accessory. Automated Leak Test (Optional). This feature, when activated, will detect leaks in flexible Olympus, Pentax and Fujinon endoscopes 1 prior to processing. The endoscopes will be pressurized within the manufacturer's specified ranges and leaks as low as 0.22 pounds per square inch gauge (psig) will be detected. Minimal pressure is maintained and monitored throughout the processing cycles. 1 Registered trademarks of Olympus Optical Co., Ltd., Pentax Imaging Company, and Fujinon Inc. CYCLE DESCRIPTION IMPORTANT: Items to be high level disinfected must be manually cleaned according to manufacturers recommendations before being placed in the Endoscope Processing Support. Processing Cycle There are four processing cycle options to choose from: SINGLE Endoscope Processing cycle with cleaning phase, to process one endoscope (one endoscope is placed in Control Handle Boot "A") through cleaning and high level disinfection phases. SINGLE Endoscope Processing cycle without cleaning phase, to process one endoscope (one endoscope is placed in Control Handle Boot "A") through a high level disinfection phase only. DOUBLE Endoscope Processing cycle with cleaning phase, to process two endoscopes (one endoscope is placed in Control Handle Boot "A" and one in Control Handle Boot "B") through cleaning and high level disinfection phases. DOUBLE Endoscope Processing cycle without cleaning phase, to process two endoscopes (one endoscope is placed in Control Handle Boot "A" and one in Control Handle 3

Boot "B") through a high level disinfection phase only. The total default cycle time with a cleaning phase is approximately 42 minutes. The total cycle time without a cleaning phase is approximately 30 minutes. Cycle time depends on the cleaning cycle settings entered in Supervisor Mode. Temperature, pressure and quality of the building water supply can also influence cycle time. The first phase of the processing cycle is an optional, programmable cleaning phase. This phase consists of a wash that uses Klenzyme Enzyme Presoak and Cleaner, followed by a rinse. The cleaning phase can be programmed ON or OFF. In the ON mode, the user can choose either one or two cleaning phases per processing cycle. Additionally the wash can be adjusted to be between five- and ten-minutes. The Reliance Endoscope Processing System cleaning phase does not replace manual pre-cleaning by the user. The second cycle phase is a high level disinfection phase that is not optional and cannot be changed by the user. In this phase, the Reliance HLD high level disinfection components (provided in a single use container) are dissolved with water at 50 C (122 F) and circulated throughout the processor and through device lumens. During the first four minutes of this phase, the active ingredient, peracetic acid, is generated from the dry components, creating the use dilution. This is followed by a six-minute high level disinfection phase at 50 C (122 F). Following the high level disinfection phase, the Reliance Endoscope Processor rinses the endoscopes through two rinse phases which are not optional and cannot be changed by the user. The processor filters the rinse water (as well as all of the water used throughout the cycle) through a 0.2 µm bacterialretentive filter. It also incorporates an automatic internal integrity check of this filter at the end of each processing cycle. If the integrity check fails, an alarm alerts the user, and the cycle printout indicates a fault code for the 0.2 µm bacterialretentive filter integrity failure. The last phase in the processing cycle is an air purge phase using HEPA-filtered air. The air purge helps to remove excess rinse water from the processed devices. The final air purge is preset to run for four minutes; additional air purge time may be selected by the operator for up to 30 minutes. If the devices are not removed from the processor at the end of the cycle, the air purge phase will continue for up to a maximum of 60 minutes total. Decontamination Cycles. The processor also features two decontamination cycles: The first, called D-SHORT, consists of hot water at 82.2 C (180 F) circulating through the processor for 13 minutes, followed by a 10-minute hot air purge at 115.6 C (240 F). This cycle must be run every 54 hours. If a D-SHORT cycle is not completed within this time interval, the processor is locked out from use until a D-LONG cycle (see below) is run. D-SHORT is intended to help prevent contamination. The second, called D-LONG, consists of a cycle in which CIP 200 Formulated Acid Cleaner is added to hot water at 82.2 C (180 F). The cleaning solution is then circulated through the processor for 20 minutes; this is followed by three rinses to remove the solution from the processor and a 10-minute hot air purge at 115.6 C (240 F). D-LONG is to be used on those occasions when the D-SHORT cycle has not been run within the past 54 hours. D-long is intended to remove contamination. TEST Cycle. A TEST cycle program is available for service and maintenance. Water Sample Test Cycle. A water sample cycle is available that enables the operator to open the chamber door during the Rinse cycle to obtain a sample of the rinse water from the sump. CONTROL SYSTEM Design Features Operator Interface Control Panel, consists of a display screen, a touch pad, ON/OFF and UNLOCK toggle switches. Display Screen The control display window features a 2- line x 16 characters, easy-to-read vacuum fluorescent display. Display shows cycle status, remaining time, alarms and instructional messages. Display also indicates abnormal conditions that may occur during a cycle. Touch Pads Membrane-type touch pads allow the operator to select, start, stop or abort cycles. An audible signal sounds to acknowledge the pressing of a pushbutton. Audible Signals The audible alarm signal warns the operator that an action must be taken or when a cycle is completed. Cycle/Day Count Recall System A Cycle/Day Count Recall System reminds the operator when a complete preventive maintenance check is required. Cycle Configuration The control system offers three different modes. Operator mode allows an operator to only Start/Stop/Resume/Abort cycles only. Supervisor mode allows an authorized operator to modify the time value for the Cleaning Wash 1 and Air Purge phases, set date and time, program Bar Code IDs, and to select the operating language, a Water Sample cycle and the repeat cleaning feature. Service mode allows a service technician to perform preventive maintenance and testing. The Service mode also facilitates troubleshooting. In addition to the adjustment of cycle values, the following operating parameters can also be changed in Supervisor mode: Time Display and Printout Units Standard AM/PM or 24 hour military time (MIL). Temperature Display Celsius ( C) or Fahrenheit ( F). Temperature is set, displayed, controlled, and printed to the nearest 0.1. Recalibration is not required when changing temperature units from C to F and vice versa. Pressures may be programmed in psi or kpa. Recalibration is not required when changing unit pressure from psi to kpa or vice versa. TECHNICAL DATA Control System Control system consists of microcomputer control boards and peripheral function circuit boards, located within the control board housing. 4

Electronic Temperature Control Resistive Temperature Device (RTD) sensors are used instead of conventional thermostats, to provide accurate control inputs and readouts throughout all phases of the cycle. Electronic Pressure Monitoring Two pressure transmitter sensors are used to provide accurate control measurements and readouts of the pressure developed within both control handle boots during the cleaning (optional) and throughout the HLD phases. A third pressure transmitter sensor is used to provide accurate pressure measurements during Filter Integrity Pressure Hold Test. Internal Battery An internal battery backs up all cycle memory for up to 10 years. If a power failure occurs during a cycle, the battery back-up system ensures that cycle memory will be retained and proper cycle completion will occur once power is restored. When power is lost, the cycle is held in phase until power is restored. Once power returns, the event is recorded on the printout and the cycle automatically resumes or is aborted, depending on which phase the cycle was in at the time of power loss. SAFETY FEATURES Safety Door Switch A microswitch prevents a cycle from starting if door is not fully closed. Safety Stop Pressing the STOP touch pad once automatically pauses operation of the unit and pressing the STOP touch pad a second time aborts the cycle. Unlock Toggle Switch Processor is provided with an UNLOCK toggle switch that must be pressed to open the door. Labeling The Reliance Endoscope Processing System is labeled with safety precaution labels and equipped with wall charts to warn and inform operator and service technicians of precautions to take and proper use of the processor. Process Monitoring The control monitors pressures within the control handle boots and warns the operator if pressures drop below the minimum requirement or exceed the maximum requirement for safe and effective processing of the devices. Water and air temperatures within the processor chamber are monitored for safe processing. The rinse water quality is automatically monitored, every cycle, by a filter integrity pressure hold test. A vacuum switch in the cleaning solution injection line signals the control when there are insufficient reserves. A level float, consisting of a magnetic float switch, controls the sump water level. A flow meter at both the hot water inlet and Klenzyme injection piping, along with an additional RTD in the sump, are part of the Double Monitoring Feature. Verify Process Indicator strips are qualitative indicators designed to be used with the Reliance Endoscope Processor. The Verify Process Indicator Strip confirms the presence of peracetic acid during the high level disinfection process. CONSTRUCTION Chamber Chamber is constructed of 20 gauge, 316L stainless steel (#4 finish), and is seam welded. Chamber is resistant to the corrosive action of chemicals and is easy to clean, with no enameled surfaces to chip or crack. Sump capacity is 15 L (four gallons). No. 304 stainless steel heating coils are included. Insulated Construction Insulated construction of chamber exterior reduces heat loss and noise level for both undercounter and freestanding units. Piping and Recirculation System All components of the recirculation system that contact chemistry, including sump, screen, rotary spray arms, pump, chemical delivery system, water filter housing, piping, and Endoscope Processing Support, are constructed of 316L stainless steel, silicone, polypropylene, and/or hydrophilic polyvinylidene fluoride (PVDF). All materials are compatible with Reliance HLD High Level Disinfectant, Klenzyme Enzymatic Presoak and Cleaner, and CIP 200 Formulated Acid Cleaner. Stainless-Steel Pump All phases are under pressure utilizing a 1.5 HP stainless-steel pump with a 249.8 L/min at 16 m at 52 ft. (66 U.S. gal/min) capacity. Pump impeller, shaft, and casing (all stainless steel construction) are fitted with a mechanical seal. Pump impeller is mounted directly on motor shaft. Pump motor is thermally protected and is equipped with a totally enclosed frame (TEFC), magnetic starter, and sealed bearings (requiring no periodic lubrication). Removable Debris Screen Debris screen, constructed of No. 304L stainless steel (#4 finish), is located at the bottom of the sump and prevents large debris from entering the piping system and pump. Screen can be easily removed for cleaning. MOUNTING ARRANGEMENT Processor is designed as a fully-enclosed cabinet for recessed or freestanding installation. Casters and flexible utility hoses are provided to allow unit to be moved in and out of mounting location for maintenance purposes. Processor is inter-piped and inter-wired, requiring only one connection for each service and utility hook-up. 5

ACCESSORIES Seismic Anchorage Kit A seismic anchorage kit is available and meets seismic building code requirements for high risk seismic zones. Report is supplied with the seismic kit. Installation Kits Installation kits include voltage-specific electrical wiring needed to install unit and printer. Also included are flexible hose and pressure regulator for cold water supply, and instructions. Bar Code Reader Allows input and traceability of important data from printed bar codes such as Operator ID, Patient ID, Device ID, Procedure ID and Physician ID. Automated Leak Test This feature, when activated, will detect leaks in flexible Olympus, Pentax and Fujinon endoscopes 1 prior to processing. The endoscopes will be pressurized within the manufacturer's specified ranges, and leaks as low as 0.22 psig will be detected. Minimal pressure is maintained and monitored throughout the processing cycles. Dual Pre-Filter and Regulator Assembly (Required) Assures hot water is supplied at optimal pressure and quality to the processor. Assembly includes: one multi-layer depth media filter cartridge, one dual-layer absolute membrane filter cartridge, one pressure regulator to reduce incoming water pressure to 345 kpa (50 psi), and one spanner wrench to easily screw and unscrew filter bowls for maintenance. Flow Units (1, 2, 3, 4 and 5) Flow Unit 1 is a Reliance Endoscope Processor accessory designed for processing Olympus, Pentax and Fujinon endoscope 1 irrigation tubes. Flow Unit 2 is a Reliance Endoscope Processor accessory made of a flexible tube assembly connected to a flow adapter at one end and a connector at the other end. Flow Unit 2 is required for processing Olympus 145/160/165/180 Series GI Endoscopes 1 with an auxiliary water channel. This channel flows from the light guide control end to the distal tip without an access port on the control handle. Flow Unit 3 is a Reliance Endoscope Processor accessory composed of a single adapter. This Flow Unit is required for Pentax P/X/00/01 Series GI Endoscopes 1 fitted with a nonremovable, mechanically-actuated valve at the control handle's auxiliary water channel port. The Flow Unit actuates the valve so that fluid can effectively flow through the auxiliary water channel. When not in use, Flow Unit 3 is screwed into the cap of the valve irrigators on the Endoscope Processing Support for convenient storage. Flow Unit 4 is a Reliance Endoscope Processor accessory required for processing Pentax 70/70K/72/72K/80K/81K/85/ 85K/90i/90K Series GI Endoscopes 1 with a water jet channel. This channel flows from the light guide control. Flow Unit 5 is a Reliance Endoscope Processor accessory that must be used when processing Cook, Medovations or CONMED esophageal dilators with a lumen (internal channel). Non-lumened dilators from Medovations, Pilling and Rusch do not require a Flow Unit to process. 1 Registered trademarks of Olympus Optical Co., Ltd., Pentax Imaging Company, and Fujinon Inc. IQ/OQ/PQ Validation Package Documentation required to test Endoscope Processing System against the requirement of ISO/DIS 15883 Part I and IV is included. Reliance Challenge Kit Includes needed hardware for testing Endoscope Processing System (cleaning, disinfection, water sampling). PREVENTIVE MAINTENANCE A global network of skilled service specialists can help provide periodic inspections and adjustments to help ensure low-cost peak performance. STERIS representatives can provide information regarding annual maintenance programs. NOTES 1. Where required by local codes, installation of a backflow preventer, such as Wilkins 975XL 1/2" NPT or equivalent (not provided by STERIS) is recommended for hot and cold water inlets. 2. Pipe sizes shown indicate terminal outlets only. Building service lines (not provided by STERIS) must supply the specified pressures and flow rates. 3. Disconnect switches (with OFF position lockout only; not provided by STERIS) should be installed in electric supply lines near the equipment. 4. Clearances shown are minimal for installing and servicing the equipment. 5. Customer must ensure processor stands on noncombustible, nonslip floor. The base language of this document is ENGLISH. Any translations must be made from the base language document. 6

Table 1. Accessories - Processor DESCRIPTION Countertop (MB00-0019) Air Compressor (MB00-0054) Seismic Anchorage Kit (MB00-0016) Installation Kits Bar Code Reader (MB00-0048) Dual Pre-Filter and Pressure Regulator Assembly (Required) (MB00-0067) OVERALL DIMENSIONS W x L x H mm (inches) 965 x 38 x 805 (38 x 1-1/2 x 31-1/8) 178 x 330 x 178 (7 x 13 x 7) 305 x 1219 x 102 (12 x 48 x 4) 279 x 533 x 381 (11 x 21 x 15) SHIPPING WEIGHT kg (lbs) 17 (38) 3.62 (8-3/4) 13 (28) 0.9 (2) 26 (12) Language Package IQ/OQ/PQ Validation Package (MB00-0070) Reliance Challenge Kit (MB00-0068) Automated Leak Test Assembly Kit (MB00-0029) APPLICATION Countertop for freestanding units. Supplies air at required 50 psi pressure for 0.2µm filter integrity test. A seismic anchorage kit is available for high-risk seismic zones. Main Electric Supply Cord, Flexible Hose and Pressure Regulator for Cold Water Inlet, Service Handles. Bar code reader to read data barcodes (includes instructions). Reduce the particulate and microbial load on the final 0.2 µm filter (includes instructions). Documentation for non-english speaking Customers. Documentation for Reliance Endoscope Processing System Cycle Validation (P920501-501). Kit includes hardware for testing Endoscope Processing System (cleaning, disinfection, water sampling). Automated leak test of Olympus, Pentax, and Fujinon Endoscopes 1. Kit includes hardware and instructions to install and perform leak testing automatically. 1. Registered trademarks of Olympus Optical Co., Ltd., Pentax Imaging Company, and Fujinon Inc. Table 2. - Leak Test Hoses DESCRIPTION ILLUSTRATION APPLICATION Leak Test Hose Assembly Kit for Pentax Endoscopes (MB00-0041) To connect to Leak Test Port of Pentax Endoscopes 1. Leak Test Hose Assembly Kit for Olympus Endoscopes (MB00-0042) To connect to Leak Test Port of Olympus Endoscopes 1. Leak Test Hose Assembly Kit for Fujinon Endoscopes (MB00-0043) To connect to Leak Test Port of Fujinon Endoscopes 1. 1 Registered trademarks of Olympus Optical Co., Ltd., Pentax Imaging Company, and Fujinon Inc. 7

Table 3. Accessories - Flow Units DESCRIPTION ILLUSTRATION APPLICATION Flow Unit 1 (EPSC001INT) To process Olympus, Pentax, and Fujinon endoscope 1 irrigation tubes. Flow Unit 2 (EPSC002INT) To process Olympus 145/160/165/180 Series GI Endoscopes 1 with an auxiliary water channel. Flow Unit 3 (EPSC003INT) To process Pentax Water Jet P/X/00/01 Series GI Endoscopes 1 fitted with an auxiliary water channel port located on the control handle. Flow Unit 4 (EPSC004INT) To process Pentax 70/70K/72/72K/80K/81K/85/ 85K/90i/90K Series GI Endoscopes 1 with a water jet channel. Flow Unit 5 (EPSC005INT) To process Cook (SGD-5/6/7/8/9/10/11/12/12.8/14/ 15/16/17/18/19/20-70 and SGD-5/6/7/8/9/10/11/12/ 12.8/14/15/16/17/18/19/20-100) Medovations 1214-15/18/21/24/27/30/33/36/39/42/45/48/51/54/ 57/60) and CONMED (000270-000275, 000277-000281 and 000288-000291) Lumened Dilators. 1. Registered trademarks of Olympus Optical Co., Ltd., Pentax Imaging Company, and Fujinon Inc. 8

Table 4. Engineering Data SHIPPING WEIGHT kg (lbs) OPERATING WEIGHT kg (lbs) A-WEIGHTED EQUIVALENT SURFACE SOUND db 331 (730) 300 (660) 65.4 1. Single or double cycle without optional phase HEAT LOSS W (BTU/hr) 710 (2420) COLD WATER L (U.S. gal) 1 PER CYCLE HOT WATER CONSUMPTION PER CYCLE 1 L (U.S. gal.) 2.9 (0.76) 46.4 (12.28) Table 5. Utility Requirements ITEM HOT WATER (HW) COLD WATER (CW) AIR DRAIN Size 5/8" Barbed M BSPT M (1/2" NPT M) 1/4" OD 30 mm ID (1-1/2") Dynamic Pressure Building Water Supply Temperature Maximum Flow Rate Quality Electricity 2.76 to 3.45 bar (40 to 50 psig) 43 C (110 F) to 48 C (118 F) 9.8 L/min (2.3 U.S. gpm) 2.06 to 3.45 bar (30 to 50 psig) 21 C (70 F) maximum 7.19 to 16.28 L/min (1.9 to 4.2 U.S. gpm) 3.45 bar (50 psig) 0.2 cfm 11.36 L/min (3.0 U.S. gpm) Potable Water, 300 ppm max CaCo 3 300 ppm max CaCo 3 See Note Below 230 V, 50 Hz, 1-Phase, 32 Amp 400 V, 50 Hz, 3-Phase, 12.1 Amp CUSTOMER IS RESPONSIBLE FOR COMPLIANCE WITH APPLICABLE LOCAL AND NATIONAL CODES AND REGULATIONS. NOTE: Maximum particulate size: 5 microns. Maximum dew point: 3-7 C (37-45 F). Maximum oil concentration: 5 mg/m 3. 9

Table 6. Cycle Description Chart SINGLE OR DOUBLE ENDOSCOPE PROCESSING CYCLE OPTIONAL PHASES WITH CLEANING REPEAT CLEANING Phase CLEANING WASH CLEANING RINSE CLEANING WASH CLEANING RINSE HLD RINSE 1 RINSE 2 AIR PURGE Water type HTW HTW HTW HTW HTW HTW HTW Set point temperature C ( F) Heated to 48.0 (118.4) Time 05:00 Adjustable: [05:00-10:00] Heated to 48.0 (118.4) 00:40 05:00 Adjustable: [05:00-10:00] Heated to 50.0 (122.0) 00:40 10:00 Generation: 04:00 * Disinfection: 06:00 *Generation starts when water temperature reaches 50.0 (122.0) 00:40 00:40 04:00 Adjustable: [04:00-30:00] Time is extended to 60:00 if treatment is not ended manually after set time. Chemical additive Klenzyme Klenzyme Reliance HLD Concentration ml/l (oz/gal) 2 (1/4) 2 (1/4) D-SHORT Decontamination cycle only, do not run with endoscopes Phase WASH AIR PURGE Water type Set point temperature C ( F) HTW Heated to 82.2 (180.0) Heated to 115.6 (240.0) Time 13:00 20:00 Venting: 10:00 Cooling: 10:00 Chemical additive Concentration ml/l (oz/gal) D-LONG Decontamination cycle only, do not run with endoscopes Phase WASH RINSE 1 RINSE 2 RINSE 3 AIR PURGE Water type HTW HTW HTW HTW Set point temperature C ( F) Heated to 82.2 (180.0) Time 20:00 Chemical is injected 10 minutes after temperature is reached. Heated to 115.6 (240.0) 00:30 00:30 00:30 14:00 Venting: 10:00 Cooling: 04:00 Chemical additive CIP200 Concentration ml/l 16 (oz/gal) (2) Legend HTW 0.2 µm filtered hot tap water Not applicable HLD = High Level Disinfection Phase in the Reliance Endoscope Processor. NOTE: Times shown in Cycle Chart do not include fill and drain times. These times may vary depending upon facility supplies. 10

Refer to the Following Equipment Drawing for Installation Details Equipment Drawing Part Number 920-011-656EN Equipment Drawing Title Reliance Endoscope Processing System Dimensions are inches [mm] Dimensions are typical - drawing is not to scale. FRONT VIEW COUNTERTOP Not For Installation SIDE VIEW 11

For Further Information, contact: STERIS Corporation 5960 Heisley Road Mentor, OH 44060-1834 USA 440-354-2600 800-548-4873 www.steris.com European Headquarters STERIS Ltd. Chancery House 190 Waterside Road Hamilton Industrial Park Leicester LE5 1QZ UK SD819 2011, STERIS Corporation. All rights reserved. (03/01/11) This document is intended for the exclusive use of STERIS Customers, including architects or designers. Reproduction in whole or in part by any party other than a Customer is prohibited.