EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Similar documents
EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CS90H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

ECO85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CS90E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

BD80 / BD80-XE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

K100P DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL PD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E DEHUMIDIFIER (FULL PRODUCT RANGE) OWNER S MANUAL

CD35 / CD35P INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL GENESIS AVENGER APOLLO AIR MOVER OWNER S MANUAL

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

GL-DEH Series Portable Dehumidifier Operating Instructions

T-Series Air Conditioner T20 Model

T-Series Air Conditioner T15 Model

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

π H-6369, H-6370 DEHUMIDIFIER GENERAL INFORMATION uline.com WATER IN THE BUCKET RECOMMENDED HUMIDITY LEVELS WARM AIR EXHAUST IS NORMAL

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

T-Series Air Conditioner T53 Model

Superdryer Dehumidifiers

FREE STAR INDUSTRIAL DEHUMIDIFIER USERS MANUAL

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Portable Dehumidifier

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

Portable Dehumidifier with Internal Pump

Quest Dry 105, 155, and 205 Dual

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

NEWGATE TECHNOLOGIES, INC.

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Dehumidifiers. Déhumidificateur. Deshumedificador. GEAppliances.com. Safety Instructions... 2, 3. Owner s Manual

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

WatchDog 900c Quick Start Guide

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

Portable Dehumidifier with Internal Pump Portable Dehumidifier with Internal Pump OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

Outdoor and Indoor Electric Refrigerator Model COAR

Installation and Operation Guide For

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

30-pint Dehumidifier User Guide

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

Instruction Manual Item No.: V~, 60Hz

20L Electronic Dehumidifier

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

Owner s Manual Unit Specifications...3 Rating Information...3. Built Right First... To Last! Warning!

Model 1820 Dehumidifier

Dehumidifier. Instruction Manual

General Care and Safety Guide

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

Quest 105, Dry155, and 205 Dual

Split Portable Air Conditioner

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

IW-25-2 Dehumidifier Installation & Operations. Manual

PERFECT CHILL WINE CHILLER. USE AND CARE MANUAL MODEL Bottle

POLAR TEMP XPORTABLE ICE MERCHANDISER SETUP MANUAL

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

DRIZAIR 110 REFRIGERANT DEHUMIDIFIER

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

Ice Maker. Model BIM25. Instruction Manual. Write Serial Number of unit here:

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W

Transcription:

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News VA 23606 Telephone (757) 873-6800 FAX (757) 873-3632 Website: www.ebacusa.com

INTRODUCTION The Ebac AD850 is a high capacity dehumidifier to operate at high efficiencies for domestic, commercial and industrial use. The Ebac AD850 removes moisture from the air through the refrigeration process and consists of the following components: Compressor Evaporator Coil Condenser Coil Centrifugal Fan Internal Humidistat Plastic Housing/Steel Chassis The fan draws the moist air through the cold evaporator coil, which cools the air below its dew point. Moisture forms on the evaporator coil and is collected in the condensate tray, which is equipped with a permanent drain. The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase, plus the additional heat generated by the compressor. The air is, therefore, discharged from the dehumidifier at a slightly higher temperature with a lower absolute humidity than that which entered. Continuous circulation of air through the dehumidifier gradually reduces the relative humidity within the area. The AD850 dehumidifier is a rugged, reliable drying unit designed to operate effectively over a broad temperature range to keep air dry and comfortable and maintain a better indoor environment. The AD850 prevents condensation, rust, corrosion, mold, mildew and microbial growth caused by condensation and excess humidity.

SPECIFICATIONS MODEL: Ebac AD850 HEIGHT: 28 WIDTH: 26 DEPTH: 12 WEIGHT: 100 lbs AIRFLOW: 300 CFM(max) CAPACITY @ 80ºF/60%: 68 lbs/day MAX. AMBIENT TEMP: 95ºF MIN. AMBIENT TEMP: 45ºF REFRIGERANT (R22): POWER SUPPLY: 26 oz 115V/60Hz/ 1 Ph MAX. AMPS: 8 Amps POWER: 920 Watts

INSTALLATION & OPERATION The following procedures should be followed to test the Ebac AD850 for correct operation: 1. After unpacking, examine all external features to confirm damage-free shipment. Report all defects and damage at once. Do not discard the packing, for it will be useful for transporting the unit in the future. 2. Connect the power cord to a grounded 15 Amp electrical outlet. Connect the supplied plastic tubing to the drainage tube, feed the tubing through the opening in the back of the unit and run this condensate line to a local drain. Ensure that the condensate line is properly fed without kinks or upward inclines of the hose. 3. Check the dehumidification process as follows: A. Place the unit on a level surface. Your unit is equipped with an adjustable humidistat. Turn the humidistat dial clockwise to the middle position. The AD850 also comes with a multiple speed fan with a fan only position. Fan speeds are as follows: POSITION WITH LARGE FAN BLADE: POSITION WITH SMALL FAN BLADE: High Speed Low Speed B. Turn the fan switch to the high-speed position and check that the compressor and fan are both running. If the unit is not running, adjust the humidistat dial clockwise until the unit turns on. The size of the room, the relative humidity and temperature will affect the required setting on your humidistat. Adjust the setting until the humidity level that you require is achieved. C. The AD850 also incorporates an automatic defrost control, which allows operation across a broad temperature range. At low ambient conditions, frost will form on the evaporator coil. The defrost control will turn the compressor off and continue drawing air through the unit until the frost is properly removed. After defrosting, the unit will automatically restart. Allow the unit to run 1 to 2 hours to insure that moisture is draining from the machine properly. If, after carrying out the above procedures, the unit does not appear to function properly, refer to the Trouble Shooting section, which follows or contact the Factory Service Center.

SAFETY PRECAUTIONS Never drop or abuse this unit. Never Place unit in standing water due to threat of electrical shock. Never remove the cover of the unit when it is either operating or attached to a power supply. Always use a properly grounded three-prong outlet. Once the unit is switched off, Always allow 5 minutes before turning the unit back on. Never put foreign objects into the inlet or outlet grills. Never restrict the inlet or outlet grills. Never attempt any servicing of the unit. Always consult the factory and have a certified electrician or technician perform repairs. Never transport unit by pulling on the power cord.

MAINTENANCE To ensure continued full efficiency of the dehumidifier, it should be subjected to periodic maintenance procedures as follows: 1.Check and clean your filters periodically. They are removable and washable filters. 2.Clean the evaporator and condenser coil surfaces by blowing any dirt or lint lint free with compressed air. Hold the nozzle of the air hose away from the coil to ensure that the fins are not damaged. 3.Check all wiring connections. 4.inspect the condensate drain for debris.

TROUBLESHOOTING SYMPTOM Unit inoperative Little or no airflow Little or no water extraction Little or no defrost when required Unit vibrates excessively Water flooding inside the machine CAUSE 1. No power to unit 1. Loose fan on shaft 2. Fan motor burnt out 3. Dirty refrigeration coils 4. Loose electrical wiring 5. Fuse blown or circuit breaker tripped 1. Insufficient air flow 2. Compressor fault 3. Loss of refrigerant gas 1. Faulty timer 2. Faulty by-pass valve 1. Loose compressor 2. Damaged fan 1. Drain tube restricted 2. Drain tube inclined REMEDY 1. Check the power from power supply panel 1. Tighten fan 2. Replace the fan motor 3. See Routine Maintenance Section 4. Check the wiring diagram to find fault and repair 5. Replace the fuse or reset the circuit breaker 1. Check all of the above 2. Contact the Factory Service Center 3. Contact the Factory Service Center 1. Contact the Factory Service Center 2. Contact the Factory Service Center 1. Tighten the nuts on the compressor mounts 2. Replace fan 1. Clear the obstruction 2. Ensure that no section of the drain hose is above the drain tray outlet

AD850 SPARE PARTS LIST Part Number Description 3014336 PVC CLEAR TUBE 3022197 COMPRESSOR 3030908 CAPACITOR 35uf 240v 3040239 2uf 415V CAPACITOR 3160129 WATER PUMP 3934515 USA PLUG Ebac Industrial Products 704 Middle Ground Boulevard Newport News VA 23606 Telephone (757) 873-6800 FAX (757) 873-3632 Website: www.ebacusa.com