D100, D125 & D150. Installation Instructions

Similar documents
Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Lo-Carbon Quadra Centrifugal Fan

Installation & Operating Instructions

Centrif Duo & Centrif Duo Plus

Lo-Carbon Quadra SELV

White - Non Illuminated Art no White - Cool White LED Art no.32600

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Installation & Operating Instructions

Lo-Carbon T-series Window & Roof Models

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

OWNERS INSTRUCTION MANUAL

Xpelair Simply Silent TM Contour Fan

Lo-Carbon SELV Tempra

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

irconcentre.co.uk airooncentre.co.uk

Xpelair Simply Silent TM DX100 Fan

Xpelair Simply Silent DX150

Turbo Inline Fan, White - Non Illuminated Art no.33500

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Simply Silent Contour 4 (100mm) Axial Extraction Fan

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Unity CV2GIP / CV2SVGIP Decentralised Mechanical Extract Ventilation (dmev) User / Homeowner Guide

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Xpelair Simply Silent DX100

Lo-Carbon Quadra Centrifugal Fan

60cm Chimney Extractor

VENT TREX. Product Guide

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

BT16.4SS-HK BT19.4SS-HK Cooker Hood

OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual

HOTLINE:

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

Lucci Designer Hi Flow Exhaust Fan

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

HR200WK Through the wall Heat Recovery Ventilator

WYND DC 54 CEILING FAN Installation Manual

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

HYDROTHERM FLOOR TO CEILING - SERIES

Xpelair Simply Silent DX100B

e Heater/Exhaust Fan/Light User s Guide

INSTALL AN ELECTRIC SHOWER

BWTC6510GL Cooker Hood 60 cm Glass cooker hood in stainless steel. BWTC9510GL Cooker Hood 90 cm Glass cooker hood in stainless steel

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

e Bath Fan with Light User s Guide

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Silhouette Installation and Wiring Instructions

Fusion HRV2 Mechanical Ventilation with Heat Recovery User / Homeowner Guide

ELTSHDC110SG/ Users Guide & Installation Instructions

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

CG60/ 70/ 80/ 90/ 100 SS/BK

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

Warnings, Safety Information and Guidance

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

ART cm Island Curved Glass

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System User / Homeowner Guide

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Hand Dryer Installation & User Manual

GEH9026G Cooker Hood

CLASSIC-100. Instruction leaflet. Instruction leaflet

FLAT2000L/R. Low Energy Positive Input Ventilation Unit. Installation and Maintenance. Alternative inlet position. 2.1 Spigot Inserts.

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

EVX110 Extractor Installation, use and maintenance

USER INSTRUCTIONS PRE- PURCHASE INFORMATION INSTALLATION INSTRUCTIONS CHIMNEY HOOD MODELS: K240 90CM

EVX101 Extractor Installation, Use and Maintenance

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

EZT90BL Extractor. Installation, Use and Maintenance.

100cm Chimney Hood GB IE

RWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: RHC60IX, RHC90IX. All dimensions in mm Model may vary slightly from images pictured

HYDROTHERM FLOOR TO CEILING - SERIES

Application and Installation Guide (excluding Solar Air Collectors)

Item:89522 P.1.

Installation Instructions

Installation Instructions

Easy Duct Tastic. User Guide. Model: Triumph Easy Duct Smart Switch Model: Sensation Easy Duct Smart Switch

ELECTRIC FAN HEATERS Devil 6002, 6003, 6005, 6009 & 6015

INSTRUCTION MANUAL. Mistral Fan /92646/92647 P.1. 3xGU10 MAX 50W

e Bath Fan with Light User s Guide

Thank you for choosing EnviroVent

User Manual for your GEH6017 & GEH9017 Cooker Hood

Domestic AC Fans 230V Installation and Operating Guide. eco. 230V AC Base Models: icon eco icon icon icon

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

KADO LUX 3-IN-1 HEAT LIGHT EXHAUST

Transcription:

D100, D125 & D150 Installation Instructions

100mm 125mm 150mm 34 l/s (124 m 3 /h) 50 l/s (180 m 3 /h) 61 l/s (277 m 3 /h) IP22/IP24 IP22 IP22 40W 60W 20W 23W 25W 40 C 40 C 40 C kg 1.3 kg 1.4 kg 1.5 kg 1 2 Ø TED1 = Ø125mm TED150 = Ø180mm 3 4 5 6a 6b 7 8 9

10 11 D100 Ø = 118mm 12 13 14 15 Ø D100 = Ø100mm D125 = Ø125mm D150 = Ø150mm 16 17 18 19 20 21

22 23 145mm 24 25 26 27 28 29 30 31 32 33

Installation Instructions Important Installation must be in accordance with these instructions. Read all instructions before commencing installations. Fans supplied with luminaire fitting must be connected to the supply earth. ight fittings should be connected to a 6 amp fused circuit. The light fitting is suitable for indoor use only. ll lights must be used in conjunction with a fan, they are not designed to be used without the fan. The electrical connections must be carried out by a qualified electrician in accordance with local Building Regulations & Wiring Regulations. l Observe appropriate safety precautions if working on steps or ladders. Wear eye protection when breaking out wall or window materials etc. l Siting otes: Where an open-flued oil or gas-fuelled appliance is installed in the kitchen, extract ventilation can cause the spillage of flue gases. Care must be taken to ensure ventilation is reduced appropriately, as set out in the Building Regulations. Kitchens with solid-fuel appliances should not have extract fans fitted. l IP safety zones: D100TC safety zone 2, ll others safety zone 3. l The fan should not be sited where it would be subject to a direct source of heat in excess of 40 C. l When installing wall mounted fans, ensure that there are no buried cables or pipes in the way. It is recommended that this fan is mounted 2.3m above floor level. l clearance of 75mm to be allowed on at least one side of the fan for the removal of the front cover. Wall installation D100, D125 & D150 Wall Fans Through wall new installation using TED1 or TED 150 ducting and DEG external grilles 1 Cut the duct to width of the plasterboard or tiled wall with slight fall to exterior. (Make provisions for cable). Make appropriate hole in wall for ducting. 2 Make good external wall with mortar or foam. Screw the protective wall grille (DEG1 for 100mm fans, DEG2 for 150mm fans) over the external duct opening. 3 Channel a hole for recessing terminal block (D100TC & D100TG only). Fill in any gaps with mortar or foam and make good around ducting. Make sure that ducting remains circular and screw holes are horizontal. 4 Drill holes for rawl plugs and screw terminal block into the hole cut for it. (D100TC & D100TG only) 5 Mark bracket screw holes, drill and plug with rawl plugs. 6a Conduit wiring from mains and wire terminal block (See wiring details overleaf). Remove break out cable entry if required. D100TC & D100TG only. ote IPX approval is based on using H05R-F cable incoming supply. Electrician should ensure any other type of cable used is waterproof. 6b Remove wiring cover. Wire fan according to wiring diagrams overleaf. Replace wiring cover. Ensure cable is secured using cable clamp provided. ll except D100TC & D100TG. 7 Screw on terminal block cover and make good around it. D100TC & D100TG only. 8 Screw the bracket to the wall using o. 8 screws provided. 9 Fix bulb if required. Undo fixing screws, slide on front cover and secure front cover to bracket using screws provided. Wall mounted using TED11 Fast Fix Ducting (D100 range only) 10 Cut the duct to equal width of the finished wall thickness with slight fall to exterior. (Make provisions for cable). Make appropriate hole in wall for ducting. 11 Push the duct into hole from the exterior. The external grille will automatically provide a watertight seal. Fit the fan following steps 3 9 above. Through wall replacement installation 12 Remove old fan. 13 Discard old fan. 14 Check ducting hole dimensions. 15 Channel a hole for recessing terminal block (D100TC or D100TG). Follow steps 3 9 above to complete installation.

Ceiling mounting D125TG 16 Secure fan holder to a joist using two o. 6 screws. 17 To wire the induct fan, first remove the wiring cover. 18 Wire up the fan according to the diagrams below. 19 Secure the cover back onto the fan. 20 Clip fan into fan holder making sure it is secure. 21 Cut flexiduct to the lengths required. 22 Cut a hole in the ceiling of the room where the light unit is to be fitted and thread through the wiring for the light unit. 23 To wire the light unit, first remove the wiring cover. 24 oosen the securing clamp on the side of the unit and thread the cable through the hole and re-secure. 25 Wire the unit according to diagram below, replace wiring cover and secure with screw provided. 26 ttach fixing clips using pins provided. Pins can be fitted above or below the fixing clip. 27 Push flexiduct through the ceiling and attached it to the light unit using one of the ties provided. 28 Use the clip fixing fingers on the unit. These are used by first slightly unscrewing the two long screws provided so that the clip fixing fingers are loose. 29 Twist the fixing fingers around so that they stick outwards. Then tighten them against the ceiling (do not overtighten). 30 Put in light bulb and clip front cover grille onto the fixing clips. 31 Prepare suitable hole through soffit or wall and fix external grille back plate using plugs and screws provided. Snap on external grille. Wiring Diagrams The electrical connections must be carried out by a qualified electrician in accordance with Part P of the Building Regulations & IEE Wiring Regulations WRIG: Disconnect fan with double pole isolating switch before starting work. The light fitting must be connected to the supply earth. ight fittings should be connected to a 6 amp fused circuit. The light fitting is suitable for indoor use only. ll lights must be used in conjunction with a fan, they are not designed to be used without the fan. djusting the Timer 32 First remove the wiring cover on the induct fan. 33 djust timer. The timer is adjustable between 1 & 30 minutes. It is factory set at midpoint. Replace the induct fan s wiring cover. Cleaning Double pole Isolating Switch Fuse Fuse Double pole Isolating Switch ight Switch Timer Junction Box (not supplied) S Switch Double pole Isolating Switch D125TG Fuse Fan Terminal S Fan Terminal S ight Unit Fan Terminal lways isolate fan before cleaning. Chrome Front Cover Basic Clean cover with a soft dry cloth. Do not use abrasive materials. Glass Front Cover Remove and wash in warm water or use a damp cloth. Do not use abrasive materials.

Greenwood ir Management td., Greenwood House, Brookside venue, Rustington, W. Sussex B16 3F United Kingdom Tel: +44 (0)1903 771021. Fax: +44 (0)1903 782398 Email: info@greenwood.co.uk Web: www.greenwood.co.uk Issue B MRCH 2007 15.10.020 MCR121 BP9325