For Complete Fire and Gas Solutions

Similar documents
SAFETY/ SECURITY - FIRE FIGHTING INTEGRATED SYSTEMS

MULTIFUNCTIONAL SYSTEM

Fire and Gas Monitoring Panel ST7-HV

Industrial Grade Gas Detection

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Safety Instrumented Fire & Gas Systems

0051 CPR 0423 CONTROL AND INDICATING EQUIPMENT WITH INTEGRATED POWER SUPPLY EQUIPMENT. ELECTRICAL AUTOMATIC CONTROL AND DELAY DEVICE (optional)

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System

Industrial Grade Gas Detection Detecting The Difference

ZXSe Range Data Sheet

Different types of Fire Alarm System

Advanced FireAlarm Panel 1-4Loop

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

3M Oldham MX 43 Controller

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

CCU Family of Modules

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

Industrial Grade Gas Detection

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Intelligent Single Loop Fire Alarm Control Panel

Fire control panel detect 3004 plus and accessories

SUPREMATouch Modular Fire & Gas Detection System

The EN54 Part 2, 4 and 13 Fire System

INTELLIGENT FIRE ALARM CONTROL PANEL

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Detection, Protection, Innovation

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

IntesisBox BACnet/IP Server - Notifier ID3000 series

Solution F2. Fire Alarm Control Panels one step ahead.

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DRAFT 20 October 2014

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

EN ASTRO-PA/GA System. ASTRO-PAGA Digital IP Public Address & General Alarm SYSTEM for INDUSTRIAL SAFETY APPLICATIONS

APPLICATION DATA SHEET

Touchpoint Pro Flexible Gas Control System

Intelligent addressable fire alarm control panel

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

2015 Honeywell Users Group Europe, Middle East and Africa

X11CA COMPUTER ANNUNCIATORS

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

2013 Honeywell Users Group Europe, Middle East and Africa. Erik de Groot. Safety and Fire & Gas Solutions

GasGard 100 Control System

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

Trusted fault tolerant technology

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

designed for rail 5000 Series

On the job around the clock 24/7: Fire detection systems

CX/CXB Self-Managed Ethernet Switches N-664 Network Appliance Data and Alarm I/O Device MX Series Multi-Port Switches

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Client's Name. Duration (Months) ESD control system upgrading in SALAM CORE PLANT. Target Engineering had conducted detailed engineering in 1993.

Protect your people, assets and environment while ensuring operational performance.

Siemens Process Automation End-user Summit- 2011

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Dependable Solutions for Gas Detection

AUTROSAFE. An interactive fire detection system for larger vessels

The EN54 Part 2 & 4 Fire System

Protect your investment with Safety Manager

FM Approved Fire & Gas Detection System

Fire alarm system EBL512 G3

Made possible by an innovative licensing scheme, which allows individual hardware configuration, up to the maximum configuration:

Reliably Advanced Extinguishing Control

explosion protection automation global partner of the process industry

ID2000. intelligent fire alarm panel

NETWORK FIRE ALARM CONTROL PANEL. Features

Protect your Investment with Safety Manager R160 and Integrated Fire and Solutions

Process Alarm Solutions

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Multi-Gas-Controller MGC2

OJD ITB No Attachment E Duress Alarm Equipment Specifications

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

30.45 Electric Release PDRP-2001

Specification/ Data Sheet

PRODUCT REVIEW Honeywell HC900 Hybrid Vacuum Furnace Control System

Honeywell SLATE ICM Platform

Field Products. Experion LX. Proven DCS for a wide range of industrial applications

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

CATALOG NUMBER. Features. Description

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

Gas Controller Module GC-06

Engineering Guideline. pac- Carriers Type Universal

Autronica Fire and Security AS ID:

Cerberus FIT conventional system

Vocia VACIE. Reference Guide

AUTROSAFE 4 A new level in interactive fire detection systems

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

APPLICATION DATA SHEET

Basics of Safety Applications

Flexible Air-sampling Smoke Detection

AUTOCALL FIRE DETECTION SYSTEMS.

VACIE REFERENCE GUIDE REVISION 1.2.6

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

by Honeywell WINMAG THE ULTIMATE VIGILON TEXT AND GRAPHICS SOFTWARE

Basics of Safety Applications

DIPL Solutions and Services

E3 Series Broadband System

Transcription:

Industrial Fire For Complete Fire and Gas Solutions

2

The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable system that keeps operations moving and minimizes downtime. The Honeywell HS-81 Fire and Gas Controller manages detection, notification, and extinguishing functions, and can integrate with process safety systems and peripherals it s everything you need. Honeywell provides a complete solution to meet any facility s safety and process requirements. Product and system design support is available for the up-front design stage, and field support is available during installation and maintenance. Honeywell is a best-in-class partner - we offer a comprehensive range of solutions designed for harsh industrial and marine environments and they all have the HS-81 Fire and Gas Controllers at their core. REQUIREMENTS SOLUTION Detect To accurately identify a site fire or gas incident that can impact the process, damage property, or hurt people Smoke Detection Heat Detection Aspirating Smoke Detection Flame Detection Gas Detection Call Points Notify To notify personnel about the issue, location, and actions Speakers Horns Beacons Strobes LED Signs Control To automatically mitigate and communicate the hazard Suppression Releasing Ties to DCS 3

The HS-81-HS Controller Honeywell is the world s leading provider of advanced automation solutions to the process industries. Among this suite of solutions, we offer an integrated industrial fire and gas system that includes flame, gas, and smoke detection; logic control and networking equipment; suppression and extinguishing capability; public address, sounders, beacons, and other safety components. These elements can be brought together to monitor the state of plant safety and they offer the user a rapid and coherent emergency response capability. The system s highly reliable architecture and advanced software enable faster and better decisions, ensuring maximum plant uptime. The HS-81 is an industrial-grade flame, gas, smoke, and extinguishing system that serves the petroleum, petrochemical, power, mining, military, and off-shore industries. It has been designed to meet the heaviest functional reliability and availability requirements with excellent resistance to electromagnetic disturbances and a continuous operability in harsh environmental conditions. Powerful Inside and Out Externally it is similar in design to a safety programmable logic controller (PLC) with printed circuit board (PCB) cards of various functions packaged within industry-standard 19 racks. A panel is fully customizable and can have up to 10 rows with each row holding up to 13 cards. There are approximately 20 different cards dedicated to functions such as extinguishing, smoke detection, gas detections, control, communications, and input. The rack has a multifunction operator interface that consists of a large, alphanumeric display with LED indicators to show system status at a glance. Each panel has its own power supply and standby battery so there is no need for external UPS. Cabinet options provide either wall mount or freestanding capabilities. Hot swap of cards and power supplies with no need for panel shutoff 4

HS-81-HS SYSTEM HIGHLIGHTS Modular Control Panel Fire Extinguishing Smoke Detection Flame and Gas Monitoring Safety PLC for Flame and Gas Addressable Smoke Detection Panel Suppression and Exstinguishing Panel Human Machine Interface (HMI) Panel Automatic Fire Extinguishing System Dedicated Command for Each Solenoid Monitoring and Diagnostics Addressable Analog Detection Multiple Protocols on One Panel Fault Monitoring Pre-Alarm, Alarm, and Alarm Verification SIL2 Detection 4-20mA Protocol with HART Front Panel Bar Graph/Numerical Displays Programmable Thresholds SIL2 Sensors Accommodated Remote Reporting Building Management System Controls Integrated Process and Building Management Software Supervision Process Control Integration Graphic Maps System Management Remote Control Ethernet TCP/IP Modbus Object Linking and Embedding for Process Control (OPC) Server and Supervisory Control and Data Acquisition (SCADA) Connect System Capacities UL EN-54 Hardware Racks 6 10 Cards 13 13 Single Point Devices 9906 16510 Addressable Devices 29,700+29,700 29,700+29,700 Software Safety Zone Capacity 300 300 Devices Per Zone 99 Inputs, 99 Outputs, 99 Logic Gates 99 Inputs, 99 Outputs, 99 Logic Gates Panels per TCP/IP Network 99 99 5

Features The HS-81 complies with fault tolerance requirements set by IEC61508 and it is capable of attaining a Safety Integrity Level 3 (SIL3 level) that is certified by a third-party agency. In addition to this high achievement with SIL, the H-S81 has some excellent features: Hot backup redundant central processing units (CPUs) eliminate downtime Hot swappable redundant CPUs and power supplies Hot swappable cards with automatic reconfiguration Redundant and looped panel communication bus Automatic testing of card inputs and outputs Self-diagnostics and fault signaling of cards and CPU Automatic safe disabling of malfunctioning cards Fire and gas applications can have redundant cards Multiple protocol addressable detection systems The HS-81 can replace several separate systems commonly found at plant site. On the right is an example where the H-S81 carries out all functions that several separate systems would typically fulfill: PLC for fire and gas detection Addressable fire detection panel for buildings Panel for suppression and extinguishing Human-machine interface (HMI) 6

Communication Systems The panel is designed to communicate with other devices of the same type, and with supervisory systems and supervisory control and data acquisition (SCADA) through multiple protocols including Ethernet TCP/IP, Modbus, and OPC Server. SUPERVISORY SYSTEM FIRE & GAS SYSTEM Supervisory Program The HS-81 can be connected to the IRIDE supervisory program, which allows easy management of the system with graphic maps from a remote location. The IRIDE program is installed on one or more PCs, which are connected to the panel via local area network (LAN) or serial cable. 7

Compact Industrial Fire Controllers The H-S81-HS/C-ULS and the H-S81-HS/C-ULD are the compact versions of the H-S81-HS with a single or double power supply, respectively. The compact panel is smaller than the H-S81-HS, designed to fit in tight spaces but also for use by those who need a discreet, user-friendly system. Like the H-S81-HS, it provides an integrated industrial protection system that includes flame, gas, and smoke detection; logic control and networking equipment; suppression and extinguishing capability; public address, sounders, beacons, and other safety components. Each panel is a modular system comprised of an enclosure (a metal cabinet with double door), display, a redundant CPU, and up to 8 I/O cards. The number and type of I/O cards are selected based on the protection needs of the facility. These panels have a single or dual redundant power supply to match either requirement. The H-S81-HSC panels are capable of supporting the F7011-UL Safety Bus Control Card (see #HI- 60946), which controls remote modules installed on a unique bus. Up to 64 remote safety bus modules can be controlled by a single F7011-UL control card, expanding the capacity of the control panel while providing optimal functionality in fault condition with high communication speed. Safety Bus System Diagram 8

Features Fire Detection Gas Detection Fire Suppression Redundancy Hot-swap with all I/O cards, CPUs, and display Addressable 8 I/O cards maximum 300 programmable fire zones 300 programmable intrusion zones 1 suppression zone per I/O card 99 input, 99 output, 99 association points per zone CPU redundancy standard Networking panels with TCP/ IP protocol Modbus RTU/Modbus TCP Protocols for interfacing with third-party systems Mechanical Features Cabinet: Sheet metal with internal door and transparent door; stainless steel option available upon request Color: RAL 7035 (Industrial Gray standard), RAL 3000 (Red for fire, optional) Protection degree: Cabinet rated for IP54/IP66, Installation: Wall mounting Size: 27.5 (700mm) x 19.7 (500mm) x 9.8 (250mm) Product UL-listed for use in dry locations Electrical Specification/Built-in Power Supply Input power: 110-240V (± 10%) Nominal output power: 24VDC Maximum output power: 4A/8A (dual supply version) Maximum batteries charging current: 4A, up to 65Ah. Up to 14Ah allowed inside cabinet. Larger batteries require use of a separate cabinet. Protections: Surge, short-circuit, and reverse battery EN54 Standard: EN54-4 CE standards: EN50081-2 and EN50082-2 (industrial environment) Safety standard: EN1508 UL standard: UL864 9th Edition Certifications SIL2 EN54 ATEX UL864 ABS Gas Detection Analog Addressable Smoke Loop Flame Detection Conventional Smoke Detection Heat Detection Analog Addressable IS and SIL2 Smoke Loop Remote Displays Aspirating Smoke Detection Supervision and Control Software HS-81 Releasing, Suppression and Extinguishing Output Control Relays, Valves, Solenoids, LEDs Sounders and Beacons Remote I/O Horns and Strobes External Systems PLCs, OPC Servers and SCADA Input Devices 9

Advantages and Benefits Modular Design The system is so flexible it can be configured for what s needed now and then easily expanded later. Redundancy Where You Need It Hot backup redundant CPUs and power supplies are built into the architecture. Hot Swap Critical Components If a CPU, power supply, or redundant I/O card needs replacement, there is no need to power down the system for repair. During normal operation the component can be removed and replaced. The system reconfigures without human intervention and without shutting down the process. Open 4-20mA Device Protocol A home run to each 4-20mA gas and flame device is the most reliable wiring method and this system works with virtually every 4-20mA scalable sensor. Easy Configuration Menu-driven pulldown programming speeds configuration and commissioning work. Product training takes two days and experienced installers are functional the first day. Networking and Third-Party Interfaces The fault-tolerant, dual-path redundant panel network can be coupled to a wide variety of plant process control systems, simultaneously communicating with multiple display and control systems. Integrated Solution Smoke, flame, gas, extinguishing, PAGA, networking, and SIS connectivity are all more than possible with a single controller. There is no need for separate systems that add complexity and cost. Single Point of Operation Configuration and programming for an entire network can all be managed through a single workstation. High Level of Safety Functional reliability and fault-tolerant operation are designed into the controller. Some examples are: daily device auto test routines, auto testing of card inputs and outputs, a looped and redundant communications bus, and safe disabling of faulty components. 10

H-S81-HS Controller Standards and Certifications: Construction Products Norm EN 12094-1:2003 European product conformity 0051-CPD-0137/138/139 Fire Detection EN 54-2, EN 54-4+A1:2002 Certificate of conformity and use of IMQ mark CA12.00956/957/958 Intruder Alarm CEI 79-2:1998 CEI 79-2; AB:2000 Certificate of conformity and use of IMQ mark CA12.00953/954/955 Functional Safety SIL2 and /or SIL3 IEC-61508 1-7:2010 SIL certification 968/EL 884.01/13 NFPA 72 (UL 864) Emergency Alarm System control units, Control Units, Releasing Device Fabrication Process Control and Surveillance FPC Production process (FCP) Certified ISO 9001:2000 GOST R Product conformity Certificate n POCC IT. AB24.B01128 Marine Equipment Directive MED 96/98/EC Harmonized standards for marine and off-shore certification in progress with ABS 11

For more information www.honeywell.com Honeywell Industrial Fire Via Lombardia 5 20010 Arluno (Milan) Italy www.scamesistemi.it HIF_S81HS_Brochure Rev B 09/17 2017 Honeywell International Inc.