Technical data LA 60TU

Similar documents
Technical data LA 28TBS

Technical data LA 9S-TU

Technical data LA 60TUR+

Advance Split

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

Starting current with soft starter Fuse protection

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

Planning guide. Atec.

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

ROOF TOP TYPE UNITS CENTRIFUGAL FANS ENGINEERING DATA MANUAL MODELS Rev. 100

Dimplex High efficiency air-to-water heat pump for indoor installation. (Low temperature) Order reference

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

PUHZ-SHW140YHA PUHZ-SHW230YKA

Air / Water Heat Pump - Compact Design Modulating 8 18 kw

WARMTEPOMPEN DIMPLEX. POMPES À CHALEUR DIMPLEX.

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

Product Range Overview 2010

HPWH 300 HPWH 300HE. Installation and Operating Instructions. Hot Water Heat Pump for Outdoor Installation. English FD 9501

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

your tree NEW TREE for you Several facts on trees: Follow our Green Tree heat pumps

History List. Version Date Update Information New EHS SPLIT TDB Released. (Modify the Spec Note)

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Technical description. Atec.

NABILATON PRO. The Nabilaton Pro heat pumps consist of MDV brand outdoor units and suitable hydraulic modules from Nabilaton.

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

HIGH-POWER HEAT PUMPS. Up to 300 kw

EHS. EHS (Mono, LT, 50Hz)

Saving energy comes naturally to us.

AIR GOLF MAXI PLUS. Heat Source Air. Technical data: High-efficiency air/water heat pumps. for tfl. max. 65 C

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

VIESMANN. VITOCAL Air/water heat pumps. Technical guide. VITOCAL 300-A Type AWC-I and AW-O. VITOCAL 350-A Type AWH-I and AWH-O

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Starting current with soft starter Fuse protection

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Pro heat station brine

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Technical data. Danfoss DHP-A

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

NIBE SPLIT ACVM 270 Air/water heat pump

NATURAL HEATING MACHINE

Heat pump & cooling unit in one

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Product Range. Overview 2015.

Starting current with soft starter Fuse protection. Heat source connection

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

50A KP 70A KP 90A KP 120A KP 150A KP 210A

HT V2 HT Split

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

Technical data. Danfoss DHP-L

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

SWIMMING POOL HEAT PUMPS

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

DESIGN & TECHNICAL MANUAL

Introduction. General requirements when using the heat pump

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

DHP-H Varius Pro+/DHP-L Varius Pro+

NIBE F2120 Air/water heat pump

Do you want a versatile solution

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

TABLE OF CONTENTS ERSQ-AAY1

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

INVERTER 9-12 DC INVERTER 9 SF

REMKO HYBRID HEAT PUMPS

ULTRA SERIES CIRCULATING AIR SOURSE HEAT PUMP WATER HEATER

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

Heat Pumps. Compact. Device Information. Operating manual supplement. LWC Series

Air/water - Heat pumps

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

Technical Data Sheet. Brine/Water Heat Pumps 8 12kW - single phase 230V. Heliotherm Basic Comfort. Basic Comfort Advantages

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

High temperature air-to-water heat pumps

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

Technical Data Ducted Three Phase Split System Air Conditioner

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

Transcription:

Technical data LA 6TU Device information LA 6TU Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance levels 2 Operating limits - Min. return temperature / Max. flow temperature 7) 18 / C +/- 2 - Lower operating limit heat source (heating operation) / Upper operating limit heat source (heating operation) -22 / C Flow / sound - Max. heating water flow rate / Pressure drop 1,4 m³/h / 8 Pa - Minimum heating water flow rate 5,3 m³/h - Heat source flow (min.) 14 m³/h - Sound power level 74 db (A) - Sound power level in accordance with EN 112 (lowered operation) 71 db (A) - Sound pressure level in 1 m 2) 5 db (A) Dimensions/weight and filling quantities - Dimensions (W x H x D) 3) 19 x x 1 mm - Weight 915 kg - Thread type, heating connection / Connection heating R / 2 inch - Refrigerant / Amount of refrigerant R417A /,9 kg - Oil type / Oil quantity Polyolester (POE) / 8,28 l - Water content 16, l Electrical connection - Rated voltage / Fuse protection 3/N/PE ~4 V, 5 Hz / Z 5 A - Control voltage / Control voltage fuse protection 1/N/PE ~2 V, 5 Hz / C 16 A - Degree of protection IP 24 - Initial current limiter Yes - Starting current 78 A - Nominal power consumption according to EN 111 at A7/W / Maximum electric power consumption 1) 15 / 27,6 kw - Nominal current at A7/W / Nominal current cos phi 26,4 A /,8 - Power consumption of the compressor protection 7 W Complies with the European safety regulations Additional model features - Type of defrosting Reverse circulation - Water in device protected against freezing 4) Yes Heat output / coefficient of performance (COP) according to EN 111: 1) Heating compressor 1 W W W A- 14, kw / 2,2 12,56 kw / 1,72 11,98 kw / 1,46 A-15 15,1 kw / 2,3 15,12 kw / 1,99 13,22 kw / 1,57 A-7 21,2 kw / 3, 17,84 kw / 2,28 17,4 kw / 1,92 A2 26,4 kw / 3,7 23,9 kw / 2,81 23, kw / 2,44 A7 31,9 kw / 4,3 29,79 kw / 3,34 28,3 kw / 2,9 A1 33,6 kw / 4,4 32,5 kw / 3,,7 kw / 3,4 A12, kw / 4,42 34,6 kw / 3,84 32,1 kw / 3,15 Heating compressor 2 W W W A- 23,5 kw / 1,99 22,51 kw / 1,69 21,5 kw / 1,54 A-15 29,34 kw / 2,31 27,76 kw / 2,1 26,71 kw / 1,73 A-7 39,2 kw / 2,9 36,4 kw / 2,44 34,3 kw / 2,22 A2 5, kw / 3,6 47,32 kw / 2,97 46,7 kw / 2,56 A7 6,1 kw / 4,1 57, kw / 3,37, kw / 2,8 A1 64,6 kw / 4,2 61,8 kw / 3,6 6,5 kw / 3,8 A12 66, kw / 4,4, kw / 3,61 63, kw / 3,15 A 8,68 kw / 4,85 78,6 kw / 4,21 76,33 kw / 3,61 Note: 1) This data indicates the size and capacity of the system according to EN 111. For an analysis of the economic and energy efficiency of the system, the bivalence point and regulation should be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on maintenance, commissioning and operation can be found in the respective sections of the installation and operating instructions. The specified values have the following meaning, e.g. A7 / W: Heat source temperature 7 C and heating water flow temperature C. 2) The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of C. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 db(a), depending on the installation location. 3) Please note that additional space is required for pipe connections, operation and maintenance. 4) The heat circulating pump and the heat pump manager must always be ready for operation. 7) Depending on the heat pump type and refrigerant used, the maximum flow temperatures in heating operation may be reduced when the outside temperature falls. Further information can be found in the operating limit diagram for the heat pump. If the supporting feet are used, the level can increase by up to 3 db (A). 1/5

Characteristic curve heating LA 6TU 1 Heat output in [kw] Water outlet temperature in [ C] 11 1 9 8 7 6 5 4 Operation with 2 compressors Operation with 1 compressor /1,4 / 7,7 / 5,3 / 5,3 1 - -1 1 4 25 15 1 5 8 Power consumption (incl. proportion of pump output) - -1 1 4 Coefficient of performance (incl. proportion of pump output) 1 9 8 7 6 5 4 Pressure drop in [Pa] Liquefier 6 4 2 1 - -1 1 4 2 4 6 8 1 12 Heating water flow rate in [m³/h] 2/5

Operating limits diagram LA 6TU Heating water temperature [ C] 75 7 6 5 4 25 15 - -25 - -15-1 -5 5 1 15 25 4 Note: The maximum possible flow temperature and the operating limits vary by +- 2K due to component tolerances. The minimum volume flow specified in the device information must be ensured at the lower operating limit. In mono energy operating mode with the heating element activated, the maximum flow temperature increases by approximately 3K. 3/5

Dimension drawing/foundation plan LA 6TU 1595 186 1 95 19 1322 4.1 21 234 839 234 2.11 1.1 1.2 2.12 8 91 818 537 916 12 187 299 X ( 1 : 5 ) 569 X 682 1844 944 1,84 m,58 m,58 m,94 m 39,4 m,8 m 91 2 m 4.1,8 m 4.2 184 2.1,3 m 1.2 1.1,3 m 39 1 m 115 185 78 213 94 1.2 1.1 5.1 5.2 5.3,2 m 5.4 5.5 2.8 2.7 2.6 4/5

Dimension drawing/foundation plan LA 6TU - Legend 1. Hydraulic connections - 1.1 Flow - 1.2 Return - 1.11 Flow (optional) - 1.21 Return (optional) - 1.3 Domestic hot water flow - 1.4 Hot water return - 1.5 Heat source flow - 1.6 Heat source return - 1.7 Filling and drain cock - 1.8 Combined heating/domestic hot water return 2. Feed-throughs/pipes - 2.1 Feed-through - condensate pipe - 2.2 Feed-through - electric wire - 2.11 Feed-through condensate pipe (optional) - 2.21 Feed-through electric wire (optional) - 2.5 Condensate drain - 2.6 Condensate pipe - 2.7 Electric empty conduit - 2.8 District heating pipe 3. Transport/operation - 3.1 Ring bolt for crane transport - 3.2 Transport tunnel - 3.3 Transport opening for carrier pipe - 3.4 Operator side 4. Air circuit - 4.1 Direction of air flow - 4.2 Main wind direction with free-standing installation - 4.3 Air inlet - 4.4 Air outlet - 4.31 Air inlet (optional) - 4.41 Air outlet (optional) 5. Foundation - 5.1 Foundation - 5.2 Green field - 5.3 Earth - 5.4 Layer of gravel - 5.5 Frost line - 5.6 Contact surface floor frame (all-round) Notes: The condensate pipe must lead to the drainage facilities. The frost line can vary according to the climatic region. The regulations of the countries in question must be observed. For unprotected free-standing installation, heat pumps without deflector hoods must be installed at right angles to the main wind direction. Depending on the heat pump type, not all points of the legend are included in the drawing. 5/5