SEWAGE SLUDGE THERMAL DRYING AND HYGIENIZATION IN A CLOSED LOOP ENERGY RECOVERING SYSTEM

Similar documents
Heat Pump Fluidised Bed Dryer with CO 2 as Refrigerant Measurements of COP and SMER

Carbon Dioxide based Heat Pump Dryer in Food Industry

HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

CHAPTER 1 INTRODUCTION

Chapter 10. Refrigeration and Heat Pump Systems

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

HFCs or the Old Refrigerants - what is the best Choice?

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

GEA Air Handling Units Modular configuration. Integrated refrigeration with optimized energy efficiency GEA CAIRplus.

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

ecodry Figure 1 - Process Diagram ecodry B General Process Description

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

DROP-IN EVALUATION OF REFRIGERANT 1234YF IN A RESIDENTIAL INTEGRAL HEAT PUMP WATER HEATER

Ammonia. Background on ammonia as a refrigerant

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

ADVANCES in NATURAL and APPLIED SCIENCES

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Keywords biomass boiler, biomass resource, Small scale sewage treatment plant, twin drum type dryer,

hydrogone horizontal disc dryer A robust and proven design for high capacity sludge drying

DEVELOPMENT OF A KILN DRIED WOOD SYSTEM USING HEAT PUMP TECHNOLOGY

ABSTRACT. 2 CanmetENERGY

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

Specific Energy Consumption of Heat Pump Drying System

Transcritical CO2 Bottle Cooler Development

A Comparison Between Refrigerants Used In Air Conditioning

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Komline-Sanderson Paddle Dryer. Drying technology for biosolids, sludges and by-products

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Department of MCE, Islamic University of Technology 2. Abstract

A study of Transient Performance of A Cascade Heat Pump System

integrated sludge treatment combined sludge drying and incineration

DEEPAK PALIWAL, S.P.S.RAJPUT

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

ANALYSIS OF LGWP ALTERNATIVES FOR SMALL REFRIGERATION (PLUGIN) APPLICATIONS

SHS AS A TECHNOLOGY PLATFORM FOR SUSTAINABLE & COMPETETIV ADVANTAGE

Comparison of Energy Efficiencies of Commercial Refrigeration Direct and Indirect Systems

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

CO2 TRANSCRITICAL BOOSTER SYSTEMS

Hydrocarbon heat and refrigeration supply systems for a mini-hotel with a shop and laundry

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Fabrication of Hot and Cold Water Dispenser

PERFORMANCE ANALYSIS OF A RE-CIRCULATING HEAT PUMP DRYER

Environmentally safe techniques in the recycling of mercury-containing materials

Chillers for High Ambient Conditions: What Technologies and Fluids?

Reduce Energy Costs with Vapor Degreasing. Mike Jones MicroCare Corp., New Britain, CT

Heat pump supplemental heating system for motor vehicles

Hydrocarbons as refrigerants

R-404A Alternative with Low Compressor Discharge Temperature

Evaluation Report, Test Run 2 (Action C2)

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

ErP. ErP READY. The Eco-Design Directive ErP for refrigerator systems and heat pumps. READY

Evaporation studied on a duplicated vessel, pilot scale evaporator equipped with a heat pump

Making equipment decisions

TYPICAL INITIAL OUTPUT OF A CO 2 HEAT PUMP

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

Solar Drying Techniques And Performance Analysis: A Review

compact BOOSTER RACK TRANSCRITICAL CO 2 Cooling capacity LT: from 2 to 130 kw Cooling capacity MT: from 20 to 300 kw

VAPOR COMPRESSION HEAT PUMP USING LOW TEMPERATURE GEOTHERMAL WATER: A CASE STUDY OF NORTHERN THAILAND

PACKAGED REFRIGERATION EQUIPMENT

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Refrigerants Type Expensive Coefficient of Performance Toxic

Low GWP Refrigerants for Air Conditioning Applications

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Systems engineering Slide 1

Commercial Refrigeration

CLIENT PROJECT. Schematic representation of sludge treatment at WWTP Homburg

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Test Report No.: Page 2 of 14

Comparison Ammonia / Secondary Refrigerant System against Direct Evaporation of HCFCs /HFCs

Homework Chapter2. Homework Chapter3

sludge2energy - Decentralised sewage sludge utilisation

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

THERMAL ANALYSIS OF CAR AIR COOLER

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

Guidance Note EC Regulation No 842/2006 on Certain Fluorinated Greenhouse Gases. BFPSA Guidance for the Fire Protection Industry

Magnetic Refrigeration. Study Case

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

TERNARY ZEOTROPIC MIXTURE WITH CO 2 COMPONENT FOR R-22 HEAT PUMP APPLICATION

Brazed Plate Heat Exchanger for CO Applications

ANDRITZ SEPARATION Thermal Treatment of Sludge

Transcription:

SEWAGE SLUDGE THERMAL DRYING AND HYGIENIZATION IN A CLOSED LOOP ENERGY RECOVERING SYSTEM A. Flaga and J. Schnotale Institute of Heat Engineering and Air Protection, Cracow University of Technology Abstract: Thermal drying and hygienization of sludge significantly enhances the number of possibilities of its further usage; not only as a fuel but also for environmental purposes. Proposed in the paper sewage sludge drying and hygienization system with a heat pump is an alternative for the traditional method of sludge drying. Heat pump drying system is energy efficient and avoids emissions from the drying installation. In that system sludge is dried by a closed loop circulating air treated in the heat pump. The refrigeration capacity of the heat pump is used to dehumidify moistened air while the heating capacity is used to reheat the cooled dry air. In the considered heat pump system carbon dioxide (CO 2 ) was applied as a refrigerant. Carbon dioxide as a natural working fluid in heat pump systems is increasingly important in view of the HFC (Hydrofluorocarbons) alternatives. Due to the critical parameters of CO 2 (t c = 31,1 o C and p c = 73,8 bar) the process in the CO 2 heat pump is the transcritical cycle. It provides the possibility of an additional hygienization of the dried product which becomes sanitarily safe and environmentally sound. The article presents some of the measured characteristics of sludge drying along with the conception of applying CO 2 heat pump for sludge drying with energy recovery and sludge hygienization. 1. INTRODUCTION The raw sludge, coming from wastewater treatment processes, is highly hydrated (up to 99%) [1, 5] therefore its further utilization in most cases is possible only after sludge dewatering and drying. Thermal drying is the last stage of removing water from sewage sludge, after thickening and dewatering. It requires the highest energy supply, but provides the best results (Fig. 1). Thermal drying of sludge significantly enhances the number of possibilities of its further usage; not only as a fuel but also for environmental purposes. The traditional methods of sludge drying are based on the process of evaporation of water in the temperature of minimum 100 o C. Consequently the drying process requires a lot of energy and therefore is very expensive with high environmental impact. The considered in the paper heat pump drying system for sewage sludge is an alternative for the traditional method of sludge drying. Heat pump recovers low temperature heat (e.g. the heat of the sewage in the sewage treatment plant) to produce a high temperature heat. It usually consists of four main elements: (1) evaporator, (2) compressor, (3) condenser and (4) expansion valve (Fig. 2). The working fluid (refrigerant) changes from liquid to gas (evaporates) as heat is absorbed from the heat source. Than it undertake a refrigeration circuit, first it goes to the compressor, later to the condenser, where the working fluid condenses to liquid (or is cooled down if a cycle is transcritical) as heat is released, and finally to the expansion valve. Heat released in condenser (or gas cooler in transcritical cycle) is the effect 25

of the heat pump work and may be used for different purposes. Heat pump needs some energy to work. Usually an electric motor is used to supply power to drive the compressor. Thickening Dewatering Drying 0 20 40 60 80 100 120 % of the dry mass (DS) in the sludge Figure 1. Concentration of dry mass (DS) in the sludge after processes of thickening, dewatering and drying [1, 2, 6]. Condenser/Gas cooler Expansion valve Evaporator Compressor Figure 2. Schematic view of the heat pump. Heat pump drying system for sludge is energy efficient and avoids emissions from the drying installation. If CO 2 is applied as a refrigerant in the heat pump the installation gives also the possibility of hygienization of the dried product, which is especially important if the sludge is to be used environmentally. In addition, carbon dioxide, a natural working fluid, diminishes the influence of the installation for sludge drying on the Global Warming Effect. 2. CONCEPTION OF THE HEAT PUMP SLUDGE DRYING SYSTEM Energy savings in the installation for sludge drying with the heat pump results from the possibility of highly efficient energy recuperation in the heat pump cycle and from realization of the drying process in a closed loop air of controlled temperature and humidity. In that system sludge is dried by a closed loop circulating air treated in the heat pump. The refrigeration capacity of the heat pump is used to dehumidify moistened air (in the evaporator) while the heating capacity is used to reheat the cooled dry air (in the gas cooler) which returns to the drying chamber (Fig. 3). Additionally, a part of heat at higher temperature is used in the hygienization chamber, which is especially important in context of the environmental utilization of dried sludge. The drying air circulates in a closed loop what makes realization of the process independent from the atmospheric conditions, what enables recuperation and hermetization of the process. Applying carbon dioxide (CO 2 ) as a working fluid in the heat pump drying system causes that the thermodynamic processes will be realized according to the transcritical cycle. It means that the working parameters of the CO 2 will cross the critical point, which for CO 2 is defined as: t c = 31,1 o C i p c = 73,8 bar. In the lower part of the cycle (connected with evaporation of the refrigerant) the 26

parameters of the working gas will be beneath the critical parameters and in the upper part of the cycle (connected with gas cooling) the parameters of the working gas will be higher than the critical parameters of CO 2. The transcritical cycle results in high compressor discharge temperature. High refrigerant temperature at the gas cooler inlet represents an advantage in a sludge dryer as it provides additional hygienization of the dried product which becomes sanitarily safe and environmentally sound. P2 gas cooler Q Z2 Qg Z3 hygienization chamber dryer mw internal heat exchanger P3 compressor Z1 Z4 Qz evaporator expansion valve P1 fan Figure 3. Conception of the heat pump sludge drying system [3]. mw Applying carbon dioxide as a refrigerant in a heat pump drying system for sludge drying not only enables hygienization of the dried sludge, but is also increasingly important in view of the HFC (Hydrofluorocarbons) alternatives. The regulations of the new 70/156/EEC Directive, concerning the use of refrigerants with GWP (Global Warming Potential) higher than 150, force engineers to look for the new kind of refrigerants. Carbon dioxide (GWP = 1), naturally present in the environment, is seen as a promising alternative to refrigerants with high GWP, usually coming from HFC group. 3. ENERGY EFFICIENCY OF THE CO 2 HEAT PUMP FOR SLUDGE DRYING To compare different technologies of drying, in respect of energy demand, Specific Moisture Extraction Rate (SMER) should be calculated for each method. SMER [kg w /kwh] is an indicator which shows the rate of moisture removed from the dried material per 1 kw of energy input to the cycle [7]. mw SMER = E Where: m w - mass of moisture removed from the dried material [kg w ]; E - energy input to the cycle [kwh] To calculate SMER for CO 2 heat pump dryer CYCLE-11UA-CO 2 program has been applied. The initial calculations showed that the considered technology is several times more energy effective 27

than most of the applied technologies for sludge drying (Fig. 4). Comparable values of SMER indicator were achieved only for Watromat technology [4], which is also based on the heat pump. However, in the heat pump from Watromat technology freon R404a is used as a working fluid. Global Warming Potential (GWP) for this refrigerant is 3750 what 25 times exceeds the recommended maximum. Therefore it is not an acceptable solution for sludge drying in reference to the regulations of the new 70/156/EEC Directive. In addition, what is the next advantage of CO 2 heat pump dryer, Watromat technology does not provide hygienization of the dried sludge. SMER [kgw/kwh] 3,5 3 2,5 2 1,5 1 MAX MIN 0,5 0 1 2 3 4 5 Drying technology: 1- CO 2 Heat pump drying; 2- Watromat technology; 3- Gas technology (direct drying); 4- Oil technology (indirect drying); 5- Steam technology Figure 4. Comparison of SMER indicators for different technologies of sludge drying [3]. 4. SLUDGE DRYING LABORATORY TESTS There is a need for laboratory tests of sludge drying process. Information gathered from such tests will help to choose the optimal technology of sludge drying and to describe sludge as a material which is being dried. For now there is no sufficient source of information which could help with that problem. All the literature concerning sludge issue is focused mostly on the processes during which sludge is being produced, on the processes of sludge thickening and dewatering and also on different methods of sludge utilization. There is an undeniable need for more information as far as sludge drying is being concerned. To fulfill the expectations in that field the laboratory for sludge drying tests has been performed. In the specially build computerized laboratory stand samples of sludge can be dried at controlled temperature and relative humidity. For now the first test series have been conducted. The results are presented in Fig. 5 and Fig. 6. Sludge sample was dried by the air of 63 degrees Celcius. After 22 hours, during which the sample reached the stabilized state with the surrounding environment, the temperature of the process air was changed to 72 degrees Celcius. It hasn t influenced the mass of 28

the sludge sample and proved that sludge has been already dried. On the basis of the mass of sludge sample obtained in the end of the test the concentration of Dry Mass (DS) in sludge during the whole process of drying was calculated. (Fig. 6) The results of the calculation showed that the initial concentration of DS in sludge taken to dry was approximately 85%. The mass of water removed during drying was approximately 109g. The mass of the sludge sample changed from approximately 129g to 20g. Mass of the dried sludge [g], Temperature of the drying air [oc], Relative humidity of the drying air [%] 130 120 Temperature [oc] 110 Relative humidity [%] 100 Mass [g] 90 80 70 60 50 40 30 20 10 0 0:00 2:24 4:48 7:12 9:36 12:00 14:24 16:48 19:12 21:36 0:00 2:24 4:48 Time of drying [h] Figure 5. The results of sludge drying test. 90,0 80,0 70,0 [%] of Dry Mass (DS) in sludge 60,0 50,0 40,0 30,0 20,0 10,0 0,0 0:00 4:48 9:36 14:24 19:12 0:00 4:48-10,0 Time of drying [h] Figure 6. The concentration of Dry Mass (DM) in sludge during the process of drying. 29

The laboratory still needs some elements to be complete. At the moment the system for humidity control is being installed. The next step will be the measurement and data acquisition system setup. 5. SUMMARY CO 2 heat pump dryer for sewage sludge drying is an energy efficient and environmentally less harmful alternative to the traditional method of sludge drying. It also provides additional hygienization of the dried product which becomes sanitarily safe and environmentally sound. Applying naturally present in the environment CO 2 as a refrigerant in the heat pump cycle is consistent with the regulations of the new 70/156/EEC Directive which excludes the use of refrigerants with GWP higher than 150. There is a need for the laboratory tests of sludge drying process which will help to choose the optimal technology of sludge drying and to describe sludge as a material which is being dried. LITERATURE [1] Bień J.B., Osady ściekowe, Teoria i praktyka. Częstochowa, Wydawnictwo Politechniki Częstochowskiej, 2002. [2] Flaga A., Usuwanie wody z osadów ściekowych jako istotny element ich dalszego energetycznego wykorzystania. Materiały Międzynarodowej Konferencji WASTE RECYCLING IX nt. Odzysk odpadów technologie i możliwości. Kraków, Wyd. IGSMiE PAN, 2005, 108-120. [3] Flaga A., Schnotale J., Ocena energetyczna zastosowania pompy ciepła realizującej transkrytyczny obieg lewobieżny w procesie suszenia osadów ściekowych. Mat. Międzynar. Konf. Nauk. Techn. ENERGETYKA 2006. Wrocław, 2006, in printing. [4] http://www.ekoeuroc.com.pl/watromat-porownanie.html [5] Kowalik P., Możliwości energetycznego wykorzystania osadów ściekowych przez ich granulację ze słomą i współspalanie z węglem. Mat. Krajowej Konf. Nauk. Techn. nt. Wykorzystanie osadów ściekowych - techniczne i prawne uwarunkowania, pod redakcją Januarego B. Bienia. Częstochowa, Wydawnictwo Politechniki Częstochowskiej, 1996, 126-136. [6] PGO 2004 Poradnik Gospodarowania Odpadami. Dashöfer Holding Ltd. & Wydawnictwo Verlag Dashöfer Sp. z o.o., zespół autorów pod redakcją dr Krzysztofa Skalmowskiego, Warszawa, aktualizacja 2005. [7] Schmidt E.L., Klöcker K., Flacke N., Steimle F., Applying the transcritical CO 2 process to a drying heat pump. International Journal of Refrigeration. Vol. 21, No 3. (1998), 202-211. 30