ONBOARD BOOSTER INSTALL

Similar documents
AJ-44 Rack Conveyor Dishmachine Maintenance Instructions. Changing Conveyor Direction

MODEL 4246 MIXER-GRINDER

! ATTENTION INSTALLER! THIS DISHWASHER IS EQUIPPED WITH A CONDENSATE REMOVAL VENT SHROUD WHICH WAS SHIPPED SEPARATELY IN ITS OWN PACKAGING.

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

DRAIN WATER TEMPERING INSTALL

INSTALLATION INSTRUCTIONS

Installation Instructions

DRAIN WATER TEMPERING INSTALL

INSTALLATION INSTRUCTIONS

KIT NOTICE. These instructions are for replacing the three existing thermostats with a single new solid-state thermostat.

KIT NOTICE. These instructions are for replacing the two existing thermostats with a single new solid-state thermostat.

WARNING DESCRIPTION PART NUMBER QTY PLUMBING, DYNATEMP DRAIN QUENCH BRACKET, THERMOSTAT DRAIN QUENCH

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

Installation Instructions

WARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

AVENGER HT THERMOSTAT RETROFIT INSTRUCTIONS

PHASE CONVERSION INSTRUCTIONS

READY RACK HOSE WASHER

SM Field Installed Electric Heat Kit

DELEVINGNE WIDESPREAD FAUCET INSTALLATION

DELTA 1200/115 INSTALLATION, OPERATION, AND SERVICE MANUAL DELTA SERIES GLASSWASHER DISHMACHINES. Delta 1200/115 Manual S

DRAIN WATER TEMPERING INSTALL

Gen II Entree Bath - All Models

TARVER SINGLE HOLE FAUCET INSTALLATION

BROEG SINGLE HOLE FAUCET INSTALLATION

WATTS WALL-MOUNT WIDESPREAD BATHROOM FAUCET INSTALLATION

LUDGATE SINGLE HOLE FAUCET INSTALLATION

PAGOSA SINGLE HOLE FAUCET INSTALLATION

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

American Dish Service

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

EDISON DUAL HANDLE VESSEL SINK FAUCET

TECHNICAL MANUAL CHEMICAL SANITIZING GLASSWASHER DISHMACHINE SERIES INSTALLATION MANUAL FOR EXPORT UNITS SERVICE MANUAL FOR DOMESTIC UNITS

OptiSoft Softeners Simple Install Steps 1-17

CEILING FAN OWNER'S MANUAL

Replacing a Gun Thermostat

Installation Instructions

HEG / RRE / WEG Series Griddle

CAOL VESSEL SINK FAUCET INSTALLATION

CBT Bowl & wrap replacement

BURWELL BIDET TOILET SEAT INSTALLATION

DISHSTAR HT-E INSTALLATION, OPERATION, AND SERVICE MANUAL DISHSTAR SERIES UNDERCOUNTER DISHMACHINES. DishStar HT-E Manual D

TECHNICAL MANUAL DUAL TEMPERATURE, GAS HEATED DOOR-TYPE DISHMACHINES INSTALLATION MANUAL FOR EXPORT UNITS SERVICE MANUAL FOR DOMESTIC UNITS

Installation Instructions

Viking Installation Guide

BlueHeat Coolant Heater

MODELS: TJ45 TJ90 Operator s Manual

The Palisade. Ceiling Fan. Net Weight 21 kg (46 lbs) Standard & Damp Location Models. Model No. FP240**

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

The Escalade OWNER S MANUAL. Ceiling Fan. Model No. FP2320** READ AND SAVE THESE INSTRUCTIONS. Net Weight 38 lbs. or 17.3 kg.

Installation Instructions

Heat Exchanger Block Replacement Instructions

Viking Installation Guide

MODEL 6430T, 6460 & 6460T POTATO PEELER

INSTALLATION INSTRUCTIONS

Commercial Electric Energy Saver Water Heater IMMERSION AND SURFACE MOUNTED THERMOSTAT MODELS

INSTALLATION INSTRUCTIONS

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

INSTALLATION INSTRUCTIONS

Installation Instructions

Preface. This guide proposes a procedure for assembling the Prisma Plus System G.

INSTALLATION INSTRUCTIONS

57" Fiberglass Exhaust Fan with Cone

INSTALLATION INSTRUCTIONS

Manifold Installation Controller MIC-180. Installation and Operation Instructions

Installation, Operating, and Maintenance Manual

Installation. All Refrigerator / All Freezer VCRB5303 / VCRB5363 / CVCRB5303 / CVCRB5363 VCFB5303 / VCFB5363 /CVCFB5303 / CVCFB5363

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

Installation Instructions

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

SERVICE & PARTS MANUAL

Hot-1 Hot Water Dispenser

Installation. Built-in Full Height Wine Cellar VCWB301

TECHNICAL INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS # BURNER ASSEMBLY REPLACEMENT

MD Munters Drive. Instruction Manual. Munters Drive * Motor and Controller Replacement Kit. Motor & Controller Replacement kit for AX and VX Fans

SAVE THESE INSTRUCTIONS

Variety Steamer Model VS-200A-A1 NIT A T L T D CM I S T E D. P/N Rev. E 03/12. Owner s Manual

Owner s Manual FS-10/FreshSpa

Pentz EF5 Installation Guide

Lavatory Faucet INSTALLATION INSTRUCTIONS P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

AHC-990 TECHNICAL MANUAL

Electric Space Heater

OWNER S MANUAL MODEL BW4B SLICER WARMER

THERMOSTAT RETROFIT INSTRUCTIONS

Installation Instructions

INSTANT-FLOW C-MICRO WATER HEATER

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Frontier TM Series Inline Chemical Heater

Transcription:

PREPARATION Disconnect electrical power at the breaker or disconnect switch and lockout/ tagout in accordance with procedures and codes. Ensure that incoming water to the machine is secured either by use of a shutoff valve or by disconnecting the incoming water line. BOOSTER 1. Unpack the booster. TOOLS REQUIRED 7/16" wrench & ratchet/ socket Phillips screwdriver Torque wrench 2. Remove the two screws on the front panel of the booster with a phillips screwdriver. 3. Remove the front panel of the booster and set it aside. 4. Punch out the holes on the side of the booster, left side for left-to-right machines and right side for right-to-left machines. L-R R-L 1 of 5

5. Install the plastic fittings provided, with the large fitting in the larger hole and the smaller fitting in the smaller hole. The plastic fittings from the kit are used in this step. 6. Remove the front panel of the machine and then remove the control box cover. 7. Remove the side panel on the rinse end of the machine (left side for right-to-left machines and right side for left-to-right machines). 8. Mount the booster on the two studs. The booster from the kit is used in this step. 9. Remove the existing hose on the machine plumbing and replace with the provided hoses, connecting them to the booster as shown below. The hoses from the kit are used in this step. 2 of 5

10. Remove the top panel and terminal block box cover. 11. With 7/16 wrench and ratchet/socket, remove the wire chute. 12. Route electrical wires from the booster through the large plastic fitting installed in Step 5, then along the path of existing wires to the back of the machine and over into the top of the machine. The wire chute will be reinstalled over these wires at the end of the procedure. 13. Connect electrical wires to the terminal block for the booster. 14. Torque each terminal connection point to a minimum of 35 in-lbs. 15. Locate the green (GRN), black (BLK), and white (WHT) wires loose in the machine control box. 16. Route all three wires through the small plastic fitting installed in Step 5 and into the booster. 3 of 5

17. Connect the GRN ground wire to the ground lug. 18. Locate the booster circuit board and locate the AC POWER IN section of the board. BOOSTER SECTION OF THE MACHINE SCHEMATIC 19. Connect the WHT wire to J2. J1 J2 20. Connect the BLK wire to J1. 21. Connect the building s power supply to the terminal block for the booster. The amperage for the booster needed to determine the appropriately-sized breakers can be located on its terminal block. 4 of 5

OPERATION 1. Open water supply valves to the unit. Ensure 110 F water is available for 70-degree rise boosters and 140 F water is available for 40-degree rise boosters. Verify that there are no water leaks during this process. 2. Turn electrical power on to the unit and booster. 3. Ensure that the drain handle is in the closed position and that the doors are shut. 4. Push the power button on the display panel of the unit. The unit will automatically fill. There might be a lag between the pushing of the button and the filling of the unit because the booster must fill first. 5. Once the wash tank is filled, the wash tank heaters will energize approximately 10 seconds later. 6. Jam the final rinse switch open to energize the final rinse valve. 7. Monitor the final rinse temperature and obtain amperage readings on each phase of the booster and compare to the ratings on the booster data plate (take the reading at the terminal block area). 8. Adjust the booster thermostat if necessary to obtain a minimum of 180 F. The thermostat should already be pre-adjusted between 185 F and 190 F (the thermostat is located within the booster control box). 9. Check for leaks once again. 10. Ensure the final rinse switch is no longer jammed for the test. 11. Replace all panels, the wire chute, and all hardware. 5 of 5