DTS SECURITY P.O.BOX 3399 Base plate-mounting EDENVALE instructions 1610 TELEPHONE

Similar documents
Stafix, EMU, EMU Compact and EMU Premium are trademarks of Tru-Test Corporation Limited.

MB Series Remote Ready Energisers INSTRUCTION MANUAL. MB550R, MB1050R and MB1750R. for models

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer. Users Manual

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

M113S Users Manual. MERLIN STEALTH M113S Electric Fence Energizer GROUP OF COMPANIES. PDF created with pdffactory trial version

ZM1 User Manual JVA TECHNOLOGIES.

Version 1.03 January-2002 USER S MANUAL

PTE0705 Electric Fence Monitor

640 Series Advanced Remote Vehicle Security System

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

Model 3901T / 3902T / 3903T

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

SP-1000X. Panic Device Power Controller Installation Guide. Rev

OWNER S MANUAL. Remote Mobile Security System. Models: PL50 PL60

ZM20 OEM Technical Manual

Model 17A00 Expansion Enclosure

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

Installation, Operating and Maintenance Manual

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...

Networked Access Control Panel. Installation Guide

Installation Instructions

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

User s Information Guide R2A

GEYSERWISE INSTRUCTION MANUAL

Protégé Eclipse LED Keypad User Manual PRT-KLES

Table of Contents. Features Quality Policy Section A - Unit Operation Section B Unit Maintenance Trouble Shooting Guide...

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

MA11 - Portable Alarm

Drying Cabinet With Timer

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

User instructions. Wingo 3524 HS Swing gate operator

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

Installation Guide for models:

LS800S Intruder Alarm System. Engineering Manual

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

WIRELESS DOOR/WINDOW CONTACT ACCESSORY (WHA3)

PRODUCT MANUAL. TT-MTM2 Hard-Wired Controller with Remote

USER MANUAL CEF AP28 CONTROL PANEL

ZLM4 OEM Technical Manual

EVO192 v3.0 Fire and Burglary What s New

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

Model AM1 Owner s Guide

636 and 646 Keypads. User s Manual

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Solution 880 Operators Manual. Issue 1.00

Sentry 4 Zone Alarm Panel User Manual

Installation and Programming manual INSTALLATION MANUAL E PROGRAMMING INSTALLAZIONE PROGRAMMAZIONE

Door Release Power Supply

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Model PT-05 Model PT-06

SECURIT 700L PLUS ENGINEERING MANUAL

FEC400 Series. Installation Manual

ECo8x Ness ECO8x AlARm CONtROl panel InstallatIon & programming manual Revision 1.5 A$15.00

HILLS Series LED Code Pad User Manual

RHMP01 MULTI PURPOSE FAN

Alarm Tone Generator Model AG17

16 Stand Fan with Remote Control Model No: FS3-40R-30

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Installation Guide for models:

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

G34 AU1B (External Ultrasonic Sensor) Version 3

INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

X64 Wireless Training

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

AP10LED 10 Zone onboard LED Alarm Panel. Engineering Manual

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Training Manual with Bi-directional Wireless

Fratech Multipath-IP STU

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

CA 120 Owners Manual of 10

THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH.

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Installation Manual RINS1211-4

Smoke Vent Control Panel PCB4 V4 Installation Manual

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

breeze easytm model # F100-1W

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Transcription:

DTS Megashock 5 Energizer 5J (Indoor installation) INSTALLATION MANUAL Comply to: SANS IEC 60 335-2-76 NRCS Ref. no. 7357 10 14 DTS SECURITY P.O.BOX 3399 Base plate-mounting EDENVALE instructions 1610 TELEPHONE 086 1000 387 Spartan +2711 392 5540 (H/O) Pretoria +2712 361 5528 Alberton +2711 907 8846 Natal +2731 916 4002 E-EEEE www.dtssecurity.co.za 1

Introduction The Megashock 5 is a mains (230V 50Hz nominal) operated energizer with battery (12V 7Ah nominal) back-up. The batteries to be used are rechargeable lead-acid batteries. Non rechargeable batteries must NOT be used. The lead-acid batteries require venting and it is imperative that the energizer be situated in a well-ventilated area. This appliance is not intended for use by persons (Including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Disclaimer DTS Security Products CC or any of its subsidiary companies does not guarantee that the operation of the product will be uninterrupted or totally error free. Energizer specifications may be altered without prior notification. The installer is referred to the definitions and general requirements in Appendix A. The installer must take into consideration the applicable municipal laws concerning the installation of electric fences. International standards can be viewed at http://www.iec.ch and South African standards on http://www.sabs.co.za. Basic Definitions Electric Fence: a barrier which includes one or more electric conductors, insulated from earth, to which electric pulses are applied by an energizer. Connecting Lead: an electric conductor, used to connect the energizer to the electric fence or the earth electrode. Electric Security Fence: a fence used for security purposes which comprises an electric fence and a physical barrier electrically isolated from the electric fence. Public Access Area: any area where persons are protected from inadvertent contact with pulsed conductors by a physical barrier. Pulsed Conductors: conductors which are subjected to high voltage pulses by the energizer. Secure Area: an area where a person is not separated from pulse conductors below 1,5m by a physical barrier. General requirements for electric security fences (Appendix A) Electric fences shall be installed and operated so that they cause no electrical hazard to persons, animals or their surroundings. Electric fence constructions which are likely to lead to the entanglement of animals or persons shall be avoided. An electric fence shall not be supplied from two different energizers or from independent fence circuits of the same energizer. For any two different electric fences, each supplied from a different energizer independently timed, the distance between the wires of the two electric fences shall be at least 2 meters. If this gap is to be closed, this shall be done by means of electrically non-conductive material or an isolated metal barrier. Barbed wire or razor wire shall not be electrified by an energizer. Any part of an electric fence which is installed along a public road or pathway shall be identified at frequent intervals by prominently placed warning signs securely fastened to the fence posts or firmly clamped to the fence wires. The size of the warning signs shall be at least 100mm x 200mm. The background colour of both sides of the warning sign shall be yellow. The inscription on the sign shall be black. The inscription shall be indelible, inscribed on both sides of the warning sign and have a height of at least 25 mm. Warning signs shall be placed at each gate, access point, intervals not exceeding 10 meters, adjacent to each sign relating to chemical hazards for the information of emergency services. Gates in electric security fences shall be capable of being opened without the person receiving an electric shock. The energizer earth electrode shall penetrate the ground to a depth of at least 1,2 meter. The distance between any electric security fence earth electrode and other earth systems shall not be less than 2 meters. Connecting leads that run inside buildings shall be effectively insulated from the earthed structural parts of the building. This may be achieved by using insulated high voltage cable. Connecting leads that are run underground shall be run in a conduit of insulating material or else insulated high voltage cable shall be used. Care shall be taken to avoid damage to the connecting leads due to external factors. Connecting leads shall not be installed in the same conduit as the mains supply wiring, communication cables or data cables. Connecting leads and electric fence wires shall not cross above overhead power or communication lines. Mains supply wiring shall not be installed in the same conduit as signaling leads associated with the electric security fence installation. Crossings with overhead power lines shall be avoided wherever possible. If such a crossing cannot be avoided, it shall be made underneath the power line and as nearly as possible at right angles to it. If connecting leads and electric fence wires are near an overhead power line, the clearance shall not be less than those shown in the table below. 2

If connecting leads and electric fence wires are installed near an overhead power line, their height above the ground shall not exceed 3 meters. Where an electric security fence passes below bare line conductors, the highest metallic element shall be effectively earthed for a distance of not less than 5 meters on either side of the crossing point. This height applies either side of the orthogonal projection of the outermost conductors of the power line on the ground surface, for a distance of: 1) 2 meters for power lines operating at a nominal voltage not exceeding 1000 volt. 2) 15 meters for power lines operating at a nominal voltage exceeding 1000 volts. Electric security fences and their ancillary equipment shall be installed, operated and maintained in a manner that minimizes danger to persons, and reduces the risks of persons receiving an electric shock unless they attempt to penetrate the physical barrier, or are in a secure area without authority. Exposed conductive parts of the physical barrier shall be effectively earthed. A spacing of 2.5 meters shall be maintained between un-insulated electric fence conductors or un-insulated connecting leads supplied from different energizers. This spacing may be less where conductors or connecting leads are covered by insulating sleeving, or consist of insulated cables, related to at 10kV. This requirement need not apply where the separately energizer conductors are separated by a physical barrier, which does not have any openings greater than 50mm. Ensure that all ancillary equipment connected to the electric security fence circuit provides a degree of isolation between the fence circuit and the supply mains equivalent to that provided by the energizer. Protection from the weather shall be provided from the ancillary equipment unless this equipment is certified by the manufacturer as being suitable for use outdoors, and is of a type with a minimum degree of protection IP54. Specifications 3

Process Control Board (PCB Dipswitch selection Dipswitch 1 - ON, Override tamper alarm switch. Dipswitch 1 - OFF, Normal run mode. Dipswitch 2 - ON, Strobe light will stay on when energizer is armed. Dipswitch 2 - OFF, Strobe light on alarm will stay on until manually reset. Dipswitch 3 - ON, Siren will on alarm go on & off for 3/8 minutes until manually reset. Dipswitch 3 - OFF, Siren will on alarm go off for 3/8 minutes, then reset itself if alarm condition is cleared. Dipswitch 4 - ON, Gate alarm delay = 3 minutes. Dipswitch 4 - OFF, Gate alarm delay = 1 minute. Dipswitch 5 - ON, Fence alarm sensitivity = 2 consecutive error cycles. Dipswitch 5 - OFF, Fence alarm sensitivity = 3 consecutive error cycles. Dipswitch 6 - ON, Alarm timer = 8 minutes. Dipswitch 6 - OFF, Alarm timer = 3 minutes. NB: Default setting would be with all dipswitches in the OFF position. 4

PCB functions 1) Important 2) J1 jumper For maintenance purposes, short out between the two pins momentary to power up the PCB if no AC power is available. 3) CN4 High Tension Feedback connection. 4) CN5 Two channel receiver connection - Channel 1 = Panic - Channel 2 = Fence trigger for ON / OFF. (Use only DTS pre-wired 2 channel energizer receiver on connection CN5) Fence wire connections (Monitored earth) 5

Fence wire connections (Non Monitored earth) DO NOT connect mains earth as fence earth. External connections Siren Relay 1 Strobe Relay 2 External ON / OFF via Keypad, Receiver or Switch (Components used must be in LATCH mode) Gate Contact (N/O) 6

Manual or Standard method of arm & disarming the fence & Fence Status 1) Low battery - Service LED will flash equal ON / OFF flashes. 2) No AC power - Power LED will be OFF. Service LED will flash short, slow flashes. 3) Faulty fence - Fence LED will flash equal ON / OFF flashes. 4) Faulty gate - Gate LED will flash equal ON / OFF flashes. 5) Faulty Unit - Service LED will be permanently ON. General hint on fault finding Switch off the unit. Remove the live and earth wires from the unit. Bridge live out to live return on the unit. Bridge earth out to earth return on the unit. Switch the unit back on. If the unit still gives an immediate alarm, return unit to supplier. If not, switch the unit off again, connect only the earth wires back onto the unit. Switch the unit back on. If the unit now gives an alarm, the unit is insufficiently earthed, add more earth spikes, or there is a communication break on the earth line. If not, the live wire has a fault on the line, search for the fault and repair before connecting the live wires back onto the unit. If the 3.15 fuse is blown, the energizer will not work of the battery. (Reversed polarities will blow the fuse). Optional DTS Two Channel receiver 7

Manufacturers warranty. All energizers manufactured by DTS Security carry a 24 month factory warranty from date of invoice. (Excluding the battery which will be 12 months) All goods are warranted to be free from faulty components and manufacture. Faulty goods will be repaired or replaced at the sole discretion of DTS Security Products, free of charge. This warranty is subject to the goods being returned to the premises of DTS Security Products. This warranty excludes lightning damage, insect damage and damage caused by faulty installation. In the event of the goods being supplied by dealer, merchant, agent or duly appointed installer of DTS Security Products, the claim must be directed to that supplier. The carriage of goods is for the customer s account. This warranty is only valid if the correct installation and application of goods, as laid out in the applicable documentation accompanying said goods, is adhered to. All warranty claims must be accompanied by the original invoice. The liability of DTS Security Products and / or their distributors is limited as herein set out DTS Security Products and / or their distributors will not be liable for consequential, incident damage or injury howsoever arising. 8