SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Similar documents
INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

HEAT RECOVERY AIR HANDLING UNIT

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

Turbo. Service Instructions

Wind. Service instruction

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

Aero. Service Instructions

USER S MANUAL. VKP Series INLINE FAN

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

AXIAL FANS USER S MANUAL

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

Calm. Service Instructions

CENTRIFUGAL FANS user's manual. model VENTS VK.

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

Centrifugal inline fans

INTELLIGENT AXIAL FAN user's manual

CENTRIFUGAL CEILING EXTRACT FAN

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

CENTRIFUGAL CEILING EXTRACT FAN

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AIR HANDLING UNITS

Axial intelligent fan USER S MANUAL

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

AXIAL FANS user's manual. model Quiet

AIR HANDLING UNIT WITH HEAT RECOVERY

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES

HEAT RECOVERY VENTILATOR

Air handling unit. BlauAir RH USER S MANUAL

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

USER'S MANUAL PS

AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

Installation manual Mini Comfort 50 S/L 07/ V EN

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL DN-2. Drain pump

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

Turbo Inline Fan, White - Non Illuminated Art no.33500

White - Non Illuminated Art no White - Cool White LED Art no.32600

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

KOMFORT EC DB Suspended heat recovery air handling units

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

CANOPY RANGEHOOD. instruction manual V3FC60SS & V3FC90SS 12 MONTH WARRANTY

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Series VENTS VUT R WH ЕС

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

VENTS КАМ. Series CHIMNEY CENTRIFUGAL FANS

ISCG90SS _03 ISCG90SS

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

KKKKKKKCOOKER HOOD INSTRUCTION MANUAL

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

USER S OPERATION MANUAL HL-RD 2000 E EC HL-RD 3000 E ЕС

UNDERMOUNT RANGEHOOD. instruction manual VPP52S & VPP90S 12 MONTH WARRANTY

Centrif Duo & Centrif Duo Plus

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

ART cm Island Curved Glass

Operating instructions

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

Cooker Hood User Manual

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

ACN SMOKE INSTALLATION AND MAINTENANCE

Lo-Carbon Quadra Centrifugal Fan

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

HEATING AND COOLING DEVICE AGC

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA

FLUEBOOST. flueboost 350 gas fire model

Operating instructions

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

AERO SERIES CEILING FAN

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

GLEB Kitchen exhaust fan

Stainless Steel Chimney Extractor

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Box60/ 70/ 90. Box60_70_90 v8

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

e Bath Fan with Light User s Guide

ENGLISH INSTALLATION AND USER S MANUAL FRENCH NOTICE D INSTALLATION ET D UTILISATION ITALIAN MANUALE D ISTRUZIONE

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

100cm Chimney Hood GB IE

Item:89522 P.1.

Transcription:

SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59

CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery set 4 Technical data 5 Mounting and operation guidelines 6 Mounting sequence 6 Connection to power mains 7 Maintenance 8 Troubleshooting 8 Acceptance certificate 9 Connection certificate 9 Warranty card 9 2 _v.1(2)-en.indd 2 10.08.2015 15:20:59

BLAUBERG Ventilatoren GmbH Company is happy to offer your attention the sound-insulated fan BLAUBERG. INTRODUCTION The present operation manual contains technical description, technical data sheets, operation and mounting guidelines, safety precautions and warnings for safe and correct operation of the fan. GENERAL The sound-insulated fans are designed for hot and highly polluted air extraction with the temperature up to 100 C in high resistance condition. The fans are used as a component of ventilation systems installed in: - industrial kitchens; - industrial bakeries; - metal processing workshops (post-welding gas removal). The fan is available for round air ducts Ø 150, 160, 200 and 315 mm. The fan must be grounded. The fan is allowed for operation only after final mounting, that includes installation of protecting devices in compliance with DIN EN ISO 13875 (DIN EN ISO 12100) as well as other construction safety equipment. The fan design is regularly improved, so some models can slightly differ from those ones described in this operation manual. SAFETY RULES The fan complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU- Directives on Electromagnetic Compatibility. All operations related to the electrical connection of the fan, like servicing and repair works are allowed only after the disconnection from power mains. All mounting and servicing operations are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present operation manual. Please follow the safety regulations and working instructions (DIN EN 50 110, IEC 364). Make sure the impeller and the casing are not damaged before connecting the fan to power mains. The casing internals must be free of any foreign objects which can damage the impeller blades. Disconnect the fan from power mains prior to any operations related to the servicing and repair works. Make sure the rotating parts have come to a full stop. Take measures to prevent contact with the fan to avoid physical damages during the fan test and start-up. Misuse of the product or any unauthorized modification are not allowed. The fan is designed for connection to ac single-phase or ac three-phase power mains, see "Technical Data". The fan is rated for permanent operation during non-stop power supply. Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney flues or other fire-protection devices. Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting. The maximum permitted pressure difference per living units is 4 Pa. The transported air must not contain any dust or other solid impurities, sticky substances or fibrous materials. The fan is not designed for use in an inflammable and explosive medium. The transported medium must not have an aggressive effect on steel at the temperature stated in the table 1 of the section Technical data. The fan motor has F class winding insulation and IP 54 ingress protection rating. Do not close or block the intake or exhaust vent not to disturb the normal air circulation. Do not sit on the fan and do not put objects on the fan. Follow the manual guidelines to ensure trouble-free operation and long service life of the product. STORAGE AND TRANSPORTATION RULES Store the delivered fan in the manufacturer's original packing box in a dry ventilated premise with the ambient temperature from +5 C up to + 40 C. Store the fan in an environment with minimized risk of mechanical damages, temperature and humidity fluctuations. Store the fan inside a room or under a shelter. Transportation of the fan is allowed by any vehicle provided the fan is transported in the original package and is protected against weather and mechanical damages. Use hoist machinery for handling and transportation to prevent possible mechanical damages. Fulfil the requirements for transportation of the specified cargo type during cargo-handling operations. Do not expose the fan to extremely low or high temperatures. MANUFACTURER'S WARRANTY The fan complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU- Directives on Electromagnetic Compatibility. The manufacturer hereby warrants normal operation of the fan over the period of two years from the retail sale date provided observance of the installation and operation regulations. In case of failure due to faulty equipment during the warranty period the consumer has the right to exchange it. If case of no confirmation of the sale date, the warranty term shall be calculated from the manufacturing date. The replacement is offered by the Seller. The MANUFACTURER shall not be liable for any damage resulting from any misuse of or gross mechanic interference with the fan. Fulfil the operation manual requirements to ensure a trouble-free and long service life of the fan.! WARNING The product is not allowed for use by children and persons with reduced physical, mental or sensory capacities, without proper practical experience or expertise, unless they are controlled or instructed on the product operation by the person(s) responsible for their safety. Supervise the children and do not let them play with the product. WARNING Do not dispose in domestic waste. The product contains in part material that can be recycled and in part substances that should not end up as domestic waste. Dispose of the fan once it has reached the end of its working life according to the regulations valid where you are. 3 _v.1(2)-en.indd 3 10.08.2015 15:21:00

FAN DESIGN Exhaust spigot Centrifugal impeller Casing Electric motor Supporting mounting frame Vibration isolator Terminal box Fig. 1. fan design The steel is made of galvanized steel and is internally filled with 50 mm thermal- and sound-insulating layer made of non-flammable mineral wool. The fan casing is installed on a supporting mounting frame with integrated vibration isolators. The swivel motor-impeller block is attached to the swivel door which facilitates the fan servicing. The fan is equipped with a single- or three-speed motor with short circuit rotor and a centrifugal impeller with forward curved blades. The impeller is made of galvanized steel. The motor is equipped with ball bearings for longer service life and a dynamically balanced turbine. F class motor winding insulation and IP 54 ingress protection rating. Overheating protection by built-in thermal switches with leads for connection to external protection devices. Smooth or step-up speed control with an auto transformer or frequency inverter. Both available upon separate order. Mounting to the wall is performed with the mounting angle bracket KS-ISK (available upon separate order). DELIVERY SET fan - 1 item; operation manual - 1 item. ATTENTION Make sure the fan has no visible transport damages and check the ordered and the delivered goods for compliance. 4 _v.1(2)-en.indd 4 10.08.2015 15:21:00

TECHNICAL DATA Table 1. Technical data Parameters 150 4E 160 4E 150 4D 160 4D 200 4E 200 4D 250 4E 250 4D Voltage, 50 Hz [V] 1 ~ 230 3 ~ 380 1 ~ 230 3 ~ 380 1 ~ 230 3 ~ 380 Power [W] 180 180 550 750 1500 1500 Current [A] 1.7 0.6 3 2 11 3.4 Max. air flow [m 3 /h] 700 730 1600 1650 3400 3500 RPM [min -1 ] 1450 1455 1475 1465 1500 1470 Noise level, 3 m [dba] 41 41 45 45 51 51 Max. transported air temperature [ C] -20... +100-20... +100-20... +100-20... +100-20... +100-20... +100 Ingress Protection Rating IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 Table 2. Overall dimensions Dimensions [mm] Type ØD B B1 H H1 L L1 L2 L3 L4 Weight [kg] 150 4E 150 410 330 540 365 525 500 470 475 205 17 150 4D 150 410 330 540 365 525 500 470 475 205 17 160 4E 160 410 330 540 365 525 500 470 475 205 17 160 4D 160 410 330 540 365 525 500 470 475 205 17 200 4E 200 485 365 600 425 625 600 570 515 235 25 200 4D 200 485 365 600 425 625 600 570 515 235 25 250 4E 250 575 435 665 505 700 675 645 620 285 40 250 4D 250 575 435 665 505 700 675 645 620 285 40 L4 D L4 L3D H1 D H H1 B1 L2 B L1 L Fig. 2. fan overall dimensions 5 _v.1(2)-en.indd 5 10.08.2015 15:21:01

MOUNTING AND OPERATION GUIDELINES WARNING Before starting mounting: Read carefully the fan mounting, start-up, operation and servicing instructions; Check the fan for possible transport damages. Follow the safety regulations during the fan start-up and operations. The fan is designed for connection to round air ducts on both sides of the fan. The special fixing brackets in the fan casing enable selecting the most suitable fan installation position. If the fan is connected through the flexible anti-vibration connectors the fan must be secured to a mounting surface with supports, hanger brackets or brackets. The air motion direction in the system must match the pointer on the fan casing. Install the fan to ensure sufficient and quick access for servicing and repair operations. The fan must be grounded. To reduce air turbulence related pressure losses connect a straight air duct to the fan of the length equal to min. 1 air duct diameter on the intake side and min. 3 air duct diameter on the exhaust side. Power is supplied either through the external terminal box. Mounting of the fan on the wall with the KS-ISK mounting angle brackets is shown in fig. 3 (available upon separate order). MOUNTING SEQUENCE 1. Cut off power supply. 4. Install the fan on the KS-ISK mounting brackets and fix it using appropriate fasteners. QF 2. Mark and drill the holes on the mounting surface for the fan mounting. 3. Fix the KS-ISK mounting angle brackets on a mounting bracket using appropriate fasteners, for example, expansion anchors. 5. Install accessories, i.e. install a backdraft damper into the fan spigot. 6. Connect air ducts to the fan and fix those with clamps (available upon separate order). 6 _v.1(2)-en.indd 6 10.08.2015 15:21:01

CONNECTION TO POWER MAINS! WARNING Read the operation manual prior to any electric installations. Connection of the fan to power mains is allowed by a qualified electrician only. The rated electrical parameters of the fan are stated on the rating plate. No modifications of internal connections are allowed and will result in void warranty. Connect the fan only to power mains with valid electric standards. Follow the respective electric standards, safety rules (DIN VDE 0100), TAB der EVUs. The house cabling system must be equipped with an automatic switch at the external input. Connect the fan to power mains through the automatic switch. The contact gap on all poles at least 3 mm (VDE 0700 T1 7.12.2 / EN 60335-1). The automatic switch trip current must be in compliance with the fan current consumption, refer Table 1. Install the automatic switch to ensure prompt access. The fan is rated for connection to single-phase alternating current power mains 230 V / 50 Hz. The recommended rated automatic switch trip current for ISO-K fans is stated in Table 3. The electric connections must be performed with insulated, durable and heat-resistant conductors (cables, wires). The recommended conductor cross section is stated in Table 3. The wiring diagram for connection of the single-phased fans is shown in fig. 3. The wiring diagram for connection of the three-phased fans is shown in fig. 4. Cut power supply to the fan off by turning the automatic electric switch QF to OFF position. Take steps to prevent activation of the automatic switch prior to finishing mounting. Connection to power mains of the basic fan model with a terminal box is as follows: 1. Cut off power supply to the fan by turning the automatic switch QF to OFF position. 2. Remove the screws that fix the terminal box cover and take off the cover. Table 3. Recommended automatic switch trip current and cable cross section. Model Rated automatic switch trip current [A] Recommended cable n x S, n wire number; S cross section, mm 2 150 4E 2 2 x 1.5 150 4D 1 3 x 1.5 160 4E 2 2 x 1.5 160 4D 1 3 x 1.5 200 4E 8 2 x 1.5 200 4D 3.15 3 x 1.5 250 4E 12.5 2 x 1.5 250 4D 4 3 x 1.5 C1 ~230 V 50 Hz N L QF W2 U2 V2 X1 U1 V1 W1 3. Route the electric cable to the terminal box through the electric lead-in and connect the cable wires to the input terminal box in compliance with the wiring diagram, fig. 3, 4. Fix the cable with nuts. Re-install the terminal box cover and fix it with screws. X1 fan terminal block С1 capacitor QF automatic switch (not included into the delivery set) Fig. 3. Wiring diagram for single-phase fans W2 U2 V2 X1 U1 V1 W1 X1 fan terminal block QF automatic switch (not included into the delivery set) 4. Turn the fan on by turning the automatic switch QF to ON position. QF L1 L2 L3 ~380 V / 50 Hz Fig. 4. Wiring diagram for three-phase fans 7 _v.1(2)-en.indd 7 10.08.2015 15:21:02

MAINTENANCE ATTENTION Cut power supply to the fan off by turning the automatic electric switch QF to OFF position. Take steps to prevent activation of the automatic switch prior to finishing maintenance. QF Disconnect the fan from power mains prior to any operations related to servicing and repair works. Make sure the rotating parts have come to a full stop. The fan technical maintenance consists in the periodic cleaning of the fan surfaces. The impeller blades required thorough cleaning once in 6 months. Cleaning procedure: cut off power supply to the fan; clean the impeller blades with a dry soft brush or compressed air. open the fan swivel panel; QF Avoid liquid dripping on the motor and inside the electronic compartment. While cleaning the fan be careful not to displace the impeller counter weights. After cleaning perform all the operations reverse. TROUBLESHOOTING Table 4. Error list and troubleshooting Fault Possible reason Remedy The fan does not operate. Automatic switch tripping. Noise, vibration. No power supply or connection error. Jammed motor, soiled impeller blades. Short circuit in power grid. The impeller is soiled. The screw connection is loose. No flexible anti-vibration connectors are installed. Make sure of correct power supply, otherwise troubleshoot the connection error. Remove the motor jam, clean the impeller blades. Turn the fan off and contact your seller for troubleshooting. Clean the impeller. Tighten the fastening screws. Install the flexible anti-vibration connectors. 8 _v.1(2)-en.indd 8 10.08.2015 15:21:03

ACCEPTANCE CERTIFICATE Sound-insulated fan 150 125 160 200 250 4E 4D is recognizes as serviceable. The product complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU-Directives on Electromagnetic Compatibility. We hereby declare that the product complies with the essential protection requirements of Electromagnetic Council Directive 2004/108/EC, 89/336/EEC and Low Voltage Directive 2006/95/EC, 73/23/EEC and CE-marking Directive 93/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. This certificate is issued following test carried out on samples of the product referred to above. Approval mark Manufacturing date CONNECTION CERTIFICATE Sound-insulated fan 150 125 4E 160 4D 200 250 is connected to power mains in compliance with this operation manual requirements by the professional: Company: Name: Date Signature WARRANTY CARD 150 125 160 200 250 4E 4D SELLER SALES DATE REPRESENTATIVE IN EU Blauberg Ventilatoren GmbH Aidenbachstr. 52a, D-81379 München, Deutschland 9 _v.1(2)-en.indd 9 10.08.2015 15:21:03