Specification Status: Released

Similar documents
Specification Status: Released

Gas Discharge Tubes. Features: Benefits: Applications:

Gas Discharge Tubes GTCX25-XXXM-R02 Series

Gas Discharge Tubes GTCX28-XXXM-R05 Series


Raychem Overvoltage Devices. ROV14, ROV14H, ROV14E 14mm Series Metal Oxide Varistors

Raychem Overvoltage Devices. ROV05, ROV05H 5mm Series Metal Oxide Varistors

Multi Layer Varistor Overvoltage Protection Device

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

Specification Status: Released

Specification Status: Released

Telecom Fuses. Benefits. Features. Applications

Specification Status: Released

PolySwitch TS600 Overcurrent Protection Devices

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications:

Specification Status: Released

SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxSA-L Series. Benefits: Features: Applications:

This document provides assistance with the selection of elements of the C5C copper pairs connection system. It includes the following sections:

MODEL 834M1 ACCELEROMETER

M7100 Pressure Transducer

Technical Paper. PPTC Circuit Protection for Power Management in Portable Communications/PDA Equipment

DATASHEET PolySwitch RKEF Devices

MSP100 Pressure Transducer

PT9600. Cable Actuated Encoder Reel. General. Environmental

MODEL 4000A & 4001A ACCELEROMETER

Raychem Link Boxes. Cable Services Limited. Powering the UK

TE Connectivity's AMP NETCONNECT Cable Management

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

PT9420 (Extended Range)

FC22 Compression Load Cell

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

NTC THERMISTOR SENSOR PERFORMANCE

QuickStat-TC Installation & Operation Manual

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

Standard SPECIFICATIONS FEATURES APPLICATIONS

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

AMP SUPERSEAL 1.5 SERIES Connectors

Sub psi SPECIFICATIONS

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

MODEL ACCELEROMETER

1N4001 THRU 1N4007 1N4001 THRU 1N SILICON RECTIFIER. Features:

WL User Manual. Innovative Technology for a Connected World. global solutions: local support TM

D5100 Industrial Differential Pressure Transducer

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

MSP100 Pressure Transducer

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

PT9150 (Extended Range)

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR ANDROID

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

Cable Actuated Sensor Industrial User Scalable 4 20mA

HM1500LF Relative Humidity Module

RayClic Connection System

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

RF one-step BNC/TNC connectors for coaxial cable termination

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR IOS

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Cable Actuated Sensor Industrial User Scalable VDC Output

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

MSP300 Pressure Transducer

MSP340 Pressure Transducer

HM1520LF Relative Humidity Module

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Seal Kits for BUDI Enclosures

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

D5100 Industrial Differential Pressure Transducer

MEAS EMITTER ASSEMBLY ELM-4000 SERIES

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

ULTRA FAST RECITIFIERS

DP86 Constant Voltage with Fitting

FIND LEAKS BEFORE THEY FIND YOU. Leak Detection and Location Systems

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

Industrial Strength Leak Detection

Model Number Structure

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

TraceTek FIND LEAKS BEFORE THEY FIND YOU

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

Apex MediTech ALC109 ALARM SYSTEM

FOSC. Fiber Optic System Technology. Fiber Optic Splice Closures (FOSC-400)

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

Cable Actuated Sensor Industrial Incremental Encoder Output

FC23 Compression Load Cell

ENERGY /// RAYCHEM CABLE CLAMPS RAYCHEM CABLE CLAMPS. Quick Reference Guide

TraceTek TT1000 Modular Sensing Cable

SETTING UP DSC INTEGRATION THROUGH ENTRAPASS

TS105-10L5.5MM Thermopile Sensor

M5800 Pressure Transducer with Rotatable Display

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

UV-SCE. Ultra-Violet light, Resistant TECHNICAL DATASHEET. Heat Shrink Identification Marker Sleeves

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

Transcription:

PAGE NO.: 1 OF 6 GENERAL DESCRIPTION BENEFITS Specification Status: Released Helps provide overvoltage fault protection against high energy surges Suitable for sensitive equipment due to excellent impulse sparkover response Suitable for high-frequency applications Highly reliable performance FEATURES Crowbar device with low arc-voltage Low capacitance and insertion loss High accuracy spark-over voltages for high precision designs Tested per ITU K.12 recommendations Optional Fail-Short mechanism Non-radioactive materials APPLICATIONS Telecommunications: - MDF modules, xdsl equipment, RF system protection Industrial Electronics and Commercial Electronics, such as - Power Supplies, Surge Protectors, Alarm systems SYMBOL TYPICAL APPLICATION SCHEMATIC PolySwitch Devices SiBar Devices

PAGE NO.: 2 OF 6 PART NUMBERING EXAMPLE: Series GT : Gas Tube Material C : Ceramic Type N : No Leads R : Radial Leaded GT C R 3 8-251 M -P 10 - FS Packaging No Suffix: standard Tray packaging -B: Bulk packaging (only upon special request) with Fail-Short mechanism Surge Rating 10 : 10kA (10 times 8 x 20μs) 20 : 20kA (10 times 8 x 20μs) Number of Electrodes Product Family 3 : Three Voltage Tolerance Diameter M : ± 20% 8 : 8mm Voltage Designator 231 : 23 x 10 ^ 1 = 230V 251 : 25 x 10 ^ 1 = 250V 351 : 35 x 10 ^ 1 = 350V DEVICE MARKING EXAMPLE : GTCR38-251M-P10-FS 25 P 10 HB Week of Manufacture Per Raychem Circuit Protection lot number system : E.g. H = Second half of 2004; B = week 2 Surge Rating: 10 : 10kA Product Family Voltage Designator 25 : 250 V Raychem Symbol

PAGE NO.: 3 OF 6 GENERAL CHARACTERISTICS No Radioactive Material Storage temperature: Devices without Fail-Short Mechanism: -40 C +90 C Devices with Fail-Short Mechanism: -20 C +65 C Operating temperature: Devices without Fail-Short Mechanism: -40 C +90 C Devices with Fail-Short Mechanism: -20 C +65 C Body: Nickel Plated Leads: Tin Plated E A B DEVICE RATINGS AND CHARACTERISTICS DC Sparkover Voltage (A-E) (B-E) Impulse Sparkover Voltage (A-E) (B-E) Insulation Resistance Capacitance DC Holdover Voltage Impulse Life (A + B - E) Impulse Discharge Current 8/20μs (A + B - E) AC Discharge Current, 50Hz (A + B - E) Part Number @ 100V/s @ 1kV/μs @ 100V DC @ 1MHz Per ITU K.12 10/1000μs, 200A Repeat 10 times (5 times each polarity) Repeat 5 times (1s interval) GTCN38-231M-P10 Part has been replaced, please use GTCN38-231M-Q10 GTCN38-231M-P10-FS Part has been replaced, please use GTCN38-231M-Q10-FS GTCR38-231M-P10 Part has been replaced, please use GTCR38-231M-Q10 GTCR38-231M-P10-FS 184-280V 700V 10,000MΩ 3.0pF 135V 300 times 10kA 10A GTCN38-251M-P10 GTCN38-251M-P10-FS GTCR38-251M-P10 Part has been replaced, please use GTCN38-251M-Q10 Part has been replaced, please use GTCN38-251M-Q10-FS Part has been replaced, please use GTCR38-251M-Q10 GTCR38-251M-P10-FS 200-300V 700V 10,000MΩ 3.0pF 135V 300 times 10kA 10A GTCN38-351M-P20 GTCN38-351M-P20-FS GTCR38-351M-P20 GTCR38-351M-P20-FS 280-420V 900V 10,000MΩ 3.0pF 80V 300 times 20kA 20A

PAGE NO.: 4 OF 6 DIMENSIONS No Leads, no Fail-Short mechanism (GTCN38-351M-P20) A C MIN MAX MIN MAX mm: 9.7 10.3 7.8 8.2 in*: 0.38 0.41 0.31 0.32 * Rounded off approximation No Leads, with Fail-Short mechanism (GTCN38-351M-P20-FS) A B C F G MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX mm: 9.7 10.3 -- 9.5 -- 8.2 -- 10.5 -- 3.0 in*: 0.38 0.41 -- 0.37 -- 0.32 -- 0.41 -- 0.12 * Rounded off approximation Radial Leads, no Fail-Short mechanism (GTCR38-351M-P20)

PAGE NO.: 5 OF 6 A C D E d MIN MAX MIN MAX MIN MAX MIN MAX NOM mm: 9.7 10.3 7.8 8.2 6.5 7.5 4.1 4.7 1.0 in*: 0.38 0.41 0.31 0.32 0.26 0.30 0.16 0.19 0.04 * Rounded off approximation Radial Leads, with Fail-Short mechanism (GTCR38-xxxx-Pxx-FS) A B C D1 E d MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX NOM mm: 9.7 10.3 -- 9.5 -- 8.2 6.0 -- 4.1 4.7 1.0 in*: 0.38 0.41 -- 0.37 -- 0.32 0.24 -- 0.16 0.19 0.04 Rounded off approximation FAIL-SHORT MECHANISM RESPONSE TIME (Graph represents typical values) GTCR38-231M-P10-FS GTCR38-351M-P20-FS Typical Fail-Short Performance

PAGE NO.: 6 OF 6 Note: Both electrodes simultaneously powered, each with the AC current value in the graph PACKAGING Packaging Bulk* ( vacuum bags) Tray Standard Box Quantity 200 100 1,000** * Standard packaging is in trays. Bulk packaging is only available upon request. ** 5 bags or 10 trays Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of each product for their applications. Tyco Electronics Corporation assumes no responsibility for the use of its product or for any infringement of patents or other rights of third parties resulting from the use of its product. No license is granted by implication or otherwise under any patent or proprietary right of Tyco Electronics except the right to use such product for the purpose for which it is sold. Tyco Electronics reserves the right to change or update, without notice, any information contained in this publication; to change, without notice, the design, construction, processing, or specification of any product; and to discontinue or limit production or distribution of any product. This publication supersedes and replaces all information previously supplied. Without expressed or written consent by an officer of Tyco Electronics, Tyco Electronics does not authorize the use of any of its products as components in nuclear facility applications, aerospace, or in critical life support devices or systems. Tyco Electronics only obligations are those in the Tyco Electronics Standard Terms and Conditions of Sale and in no case will Tyco Electronics be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of its products. 2005, 2007 Tyco Electronics Corporation. All rights reserved.