The Dorm Room Genie. The Door Lock --To be completed by David Nedzel

Similar documents
DESTINY OWNER S MANUAL

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01

Destiny Destiny Owners Manual

User s Guide FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA. K5309-5V5 11/08 Rev. A OFF 3 STAY 2 AWAY 1 OFF A B C D 5 TEST 8 CODE 9 CHIME FA260 # FA560

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

VISTA-20PMT. Security. Systems. User s Guide. Monitronics

ADEMCO VISTA SERIES User Guide

Contents. Glossary

LED Keypads D720 Series User s Guide

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

HMS MODEL 925 OWNER'S MANUAL

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

L900 series USER MANUAL

HMS MODEL 800 Owner s Manual

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional

HOME AUTOMATION, INC. Control & Security System. Owner's Manual

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

9,67$36HULHV 6HFXULW\6\VWHPV 8VHU*XLGH K5309-1V1 7/02

Digiplex LED Keypads User s Manual

IDS816 User Manual H Issued January 2009

/10 Rev A

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

VISTA-50P VISTA-50PUL

Welcome to smarter living. New Resident User Guide

Omni LTe WEB VERSION. Owner's Manual. Control & Security System. Includes the SIA CP-01 Control Panel Standard Features for False Alarm Reduction

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

SA 2650 Kit User Manual

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

Watchguard WGAP864 User Manual

ACTIVE 250 USER GUIDE

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

VISTA-128BPT/ VISTA-250BPT/ VISTA-128BPTSIA

Using Your. Security System With LED Keypad S5030, S5031, S5032

Each reader connected to the Challenger LAN system is programmed as an Arming Station.

VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B

MEGA WAY LCD 4-CHANNEL MOTORCYCLE ALARM SECURITY SYSTEM. Operation Manual MEGATRONIX CALIFORNIA, U.S.A. MEGA 3100 OPERATE 1

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

HARDWIRED CONTROL PANELS

Table of Contents. Page Code

LYNX Touch L5210 Series Security System

User's Manual VISTA-40 N7003V1 6/97

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

Technical Manuals Online! - K4855V1 3/00 FA560 3 STAY B 1 OFF 2 AWAY 6 C D 5 TEST 9 CHIME # 8 CODE I I I I I I READY ARMED MAX

ALARM SYSTEM USER S MANUAL Rev

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

abode Web app Functionality

U ser's Guide PC6010

G4S SMARTalarm User Guide

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat

USER GUIDE HARDWIRED CONTROL PANELS

Series. NX-4-EUR Control Panel. Installation manual

D1265. User's Guide. Touchscreen Keypad

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

GV2 Series Control Panels

DYGIZONE GJD910 Lighting Controller & Enunciator

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

VISTA-128BP/VISTA-250BP/ VISTA-128SIA Enhanced Commercial Burglary Partitioned Security System With Scheduling User Guide K5895V5 4/09 Rev C

Table of Contents. Appendix A Special Characters 31

9,67$ 6(D 6\VWHP 6HFXULW\ 86(5 *8,'( N7229AUV2 12/99

AXI LED USER MANUAL (REV. 1.0)

AMX 68 Owner's Manual 12/29/97

User s Manual

PROGRAMMING PROCEDURES (Table 3)

4286/4500 Voice Module Set up and Troubleshooting

MOOSE MPI 50 CONTROL PANNEL

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Owner's Manual. Includes the SIA CP-01 Control Panel Standard Features for False Alarm Reduction

Security System. User Guide for the LED Command Center

ADEMCO VISTA-12A ADEMCO VISTA-12E Security Systems

IDM4 CARAVAN ALARM. Operating instructions

D1255RB/D1256RB/D1257RB

6HFXULW\6\VWHP 8VHU*XLGH N8891V2 6/99

USING DEVICE COMMANDS

USER GUIDE HARDWIRED CONTROL PANELS

Program version Alarm Control Panel USER MANUAL GDAŃSK. versa_u_en 03/09

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

IQ PANEL USER GUIDE SMARTHOME.

Challenger10 Users Manual

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

i on Compact Security System

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

Security and Home Control. Welcome to Your Connected Home. Life in tune.

DS7400Xi (version 3+) Security System User s Guide

Universal Sensor. Installation Guide. t: f: e: w: uk.tunstall.com Version: V2.97 (421V0R1.

WLS900 Wireless Security System. Table of Contents. Your installing company is, Name: Address: Phone: Your monitoring station is, Name: Phone:

USER GUIDE HARDWIRED CONTROL PANELS

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Area Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Solution 4+4 Operators Manual ISSUE 1.25

Transcription:

The Door Lock The Dorm Room Genie Students are issued keys by which to access their rooms, but far too often a key is forgotten inside the room leaving someone locked out. After a lockout, a student must go to the front desk and obtain the spare key. If the spare key was locked inside as well, the student must call someone to come over and open their door. Needless to say, if you locked yourself out during a late-night bathroom run, this is a little inconvenient. The door lock allows the student to set an alphanumeric access code which will release the door latch and let the student enter. The student will be able to set their own access code, and change it whenever they choose. The lock can also be set to unlock mode. This will allow a student to leave the door unlocked if they will be frequently leaving or entering, or if they wish to allow anyone to come in while they are inside. The lock will also have an inactive mode. This mode will allow the user to disable the keypad entry while they are inside. This will provide an extra layer of security as the only way to gain entry at that point would be to obtain the spare key. This feature could only be turned on while the student is inside via the inside user interface and would be automatically disabled if the student opens the door. This will prevent the student from accidentally disabling the keypad and locking themselves out. Additional Parts Required: Electronic Latch (but recognizing that this is an expensive item, often not useful to 6.111 students, we ll use an LED to indicate the status locked or unlocked of the latch.) Inputs: time, 8-bit wide alpha-numeric keystroke input, door-sensor, lock, unlock, inactive, change password Outputs: lock-state, lock control The door lock has several internal states: 1. Unlocked: In this state, the user may transition to locked, inactive, or password change mode by pressing the appropriate key. 2. Locked: In this state, the user may transition to unlocked, inactive or password change mode by pressing the appropriate key. The user may also enter the entry state by typing in the current password 3. Entry: In this state the lock will unlock for 5 seconds, or until the door opens, whichever is shorter, and then return to the locked state. The user may also transition to locked, unlocked, inactive or password change by pressing the appropriate key. 4. Inactive: In this state, the user may transition to locked, inactive or password change mode by pressing the appropriate key. By opening the door, the state will automatically transition to locked. 5. Password change: In this state, the lock will accept a new password after prompting the user for the old password. After the password change sequence is complete, the lock returns to the locked state.

The Burglar Alarm System The Dorm Room Genie also implements a burglar alarm. The alarm provides additional security by sounding an alarm when the door is opened. This can be useful both when the student is home, and away from their room. While at home, a sleeping student will be awoken, and able to intercept the intruder. If away, friends nearby could respond. Additional Parts Required: magnetic sensor switch, alarm buzzer Inputs: time, door-sensor, lock-mode, lock-state, wake-up, arm, disarm Outputs: burglary, burglar alarm-state The burglar alarm has several states: 1. Disarmed: The alarm can transitions to armed or exit when the user pushed arm depending upon whether the door is open or closed. 2. Armed: The alarm can transition to burglary if the door is opened, or disarmed if the if the appropriate key is pressed. 3. Exit: The alarm transitions to armed when the door closes 4. Burglary: the alarm transitions to disarmed when the password is entered, or else armed once 2 minutes have elapsed and the door is closed. Extension: If we have additional time, we might implement a feature to inform the student of any intrusions and when they occurred once the alarm has been disabled. Clock The clock is designed to keep the system time. The clock will have the basic features of a standard digital watch. The clock will take the 27mghz internal clock and convert it to seconds. The clock module will then use the seconds and the time set by the user to keep the current time. The clock will be used by the burglar alarm, lighting, and alarm clock modules, so that they may use it to implement certain functionality. The clock will output the time to the display module, so that it can be displayed to the user. Inputs: set time Outputs: time Wakeup Alarm The alarm clock module will implement additional functionality to the clock. The alarm clock allows the student to be gently awoken by light, even if their curtains are closed. The lights will gradually brighten, reaching their brightest level at the pre-programmed time. If the system is not deactivated, the lights will begin to flash, and eventually, the burglar alarm will sound in shorts bursts if the student fails to acknowledge the wake-up sequence. Additional parts required: Buzzer (same buzzer as burglar alarm)

Inputs: set wake-up alarm, alarm acknowledge, snooze, time Outputs: alarm, buzzer, wake-up time, wake-up state; The alarm clock has several states: 1. Off: If the alarm clock is not set, it will not go off. 2. Set: In this state, the user has set the time to wake up and has requested a wakeup, but the time has not yet been reached. The alarm clock continues to wait until the current time reaches the lighting threshold time before transitioning states. 3. Wake-up sequence: At this point, the current time is within the wake-up time threshold and the lights will slowly begin to turn on, reaching full intensity at the set time. 4. Active: After the programmed wake up time has passed, the system waits a few minutes before beginning to beep the buzzer. 5. Snooze: The lights will dim briefly and the buzzer will be silenced in order to give the user a few extra minutes of sleep. The Lighting Control The lighting dimming control circuitry can be set to off, manual, automatic, and sleep mode. When in off mode, the lights will remain off. In manual mode, the user can manually adjust the brightness of the lights. In automatic mode, the lights will automatically adjust their brightness based upon input from a photo-electric sensor. As the sun sets, or lighting is otherwise reduced, they will turn themselves on. The lighting module also interfaces with other modules. When the student returns home, the lights will switch from off to automatic mode. The lighting module also interfaces with the burglar alarm, flashing the lights when an unauthorized entry is detected. Finally, the lighting module can be put in sleep mode. During sleep mode, the lights remain off, even if the student returns home during while it is dark, an important feature for middle-of-the-night bathroom visits. While in sleep mode, the light control circuitry also interacts with the alarm clock as described below. Additional Parts Required: photo-electric sensor, digitally controlled dimming module for a lamp. Inputs: clock, manual lights, automatic lights, sleep-mode, lights on, lights off, dim, brighten, burglary, wake-up, photoelectric sensor Outputs: lighting state, light control The lighting control has several states: 1. Off: In this state, the lights remain off and automatic adjustment by system is disabled. 2. Manual: The user can adjust the brightness manually through a keyboard command. When in this state, automatic operation is disabled. 3. Automatic: When in this state, light intensity is controlled by the system. As it gets darker, the light intensity is increased. 4. Sleep mode: In this state, the system enters sleep mode on request by the user. The lights remain off and automatic operation is suspended until the alarm clock has gone off, then automatic mode is resumed.

The Keyboard In order for the user to interact with the system, there must be a way for the user to provide input to the system. This is accomplished with a keyboard. The keyboard module interoperates keystrokes, synchronizes and debounces them, and passes the appropriate signals onto all the modules of the system. Input: PS2 keyboard Outputs: 8-bit alpha-numeric keystroke, lock, unlock, inactive, change password, arm, disarm, set time, manual lights, automatic lights, sleep-mode, lights on, lights off, dim, brighten, set wake-up alarm, alarm acknowledge, snooze The Display and Aaron Stonely The display for the user interface will show the current status of the door lock, burglar alarm, lighting control, and alarm clock features. This will allow a user to verify if their settings are correct, and make changes as needed. Inputs: time, lock-status-display, burglar-alarm-state, wake-up state, wake-up time, lighting state, lighting brightness Outputs: hsync, vsync, blank, [2:0] pixel (to drive the video output)