WORKING WITH MEP ELEMENTS Smart Sprinklers extension

Similar documents
INDOOR CLIMATE OF A SINGLE ZONE

OPERATIONAL PROCEDURES

Spacing Average distance between seeds in a given row of planted seeds. Results are expressed in inches.

revitpure.com Copyright BIM Pure Productions

Manage Alarms. Before You Begin CHAPTER

Manage Alarms. Before You Begin CHAPTER

ND4000 Manual Marine Hydraulics

Manage Alarms. Before You Begin. NTP-E57 Document Existing Provisioning CHAPTER

Manage Alarms. Before You Begin CHAPTER

i-vu CCN 4.0 Owner s Guide

Alarms Updated 03/26/2018

1 Air Handling Units In ICE

ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET

Smoke Layer Height and Heat Flow through a Door

Alarm Coordination Connected Components Building Block. Quick Start

Avigilon Control Center System Integration Guide

VNCManager. Version June Developed by:

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Avigilon Control Center 5 System Integration Guide

Lighting Xpert Insight User Manual

Manage Alarms. Before You Begin CHAPTER

Avigilon Control Center 5 System Integration Guide

Running IGSS as an Operator, Part One

BIM Integration of Landscape Objects: Recording Water Consumption for Management and Digital Modeling

Manage Alarms. Before You Begin CHAPTER

Smoke Layer Height and Heat Flow through a Door

DIALux evo Tutorials. Tutorial 1. How to create a cornice

[ [ ADMIN PANEL USER GUIDE

Desigo Total Room Automation User Guide Version 2.1. A6V _en_a_ Building Technologies

RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS

Version May 31, 2000

Plenum Fans. Model HPA. Direct Drive

ESB Tools Reference Guide. Version: CR2

Using BIM model for Fire Emergency Evacuation Plan

Architectural and Engineering Specification for a Real-Time Locating System Flare

Daikin VRV Systems Plugin VE2012 User Guide

Waters 2795 Separations Module

Daikin VRV Sizing & Simulation Plug-in User Guide

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

Configuring Thresholds

DryLINK TRAINING Phoenix DryMAX XL and DryLINK

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Alarm User Guide IGSS Version 9.0

Interior Design Tutorial

Installing ProSeries 2005

Advanced Features Guide of Visual MIBrowser Pro

IQ PANEL USER GUIDE SMARTHOME.

Interior Design Tutorial

USER S GUIDE. AXIS Cross Line Detection

PageOne 2-way Pager Assured 2-way messaging for critical communications

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

TV2 Room Pressure Monitor Quick Start Guide

AIR CONDITIONER PERFORMANCE RATING

HBC-4301 Hot Bonding Controller. Operators Manual

Interior Design Tutorial

Fire and Security Specification

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

1Curtain Walls Access

Using the Dome On/Off Plug-In Switch with SmartThings. Table of Contents

Options Specification

STRIPEYFISH. Utilities for VMware Series. sfvalarms User Guide

TORO SENTINEL APPLICATION NOTE AN04: ACTIVITY / ALARM MONITOR

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010

Honeywell Total Connect Remote Services

Experion PKS Operator Course EXP01R201 06/2004 Rev 01

Table of Contents. i-vu CCN Standard 4.2

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

IXIUM. DVR Smoke Alarm. User Manual

User Manual. Dryer Controller M720

Contacting Onset Mailing Address: Phone: Fax: Hours of Operation: E mail: Main Onset Web site: Copyrights and Trademarks

Complex alarming made simple

False Alarm Management

CalPro. Calibration Procedures for use with GAGEtrak 7. Installation Guide

Photo 5 Photo 6 Note: Once you connected the dehumidifier to the local network you can install the app on any other mobile phones and use Scan QR key

Halton SAFE / 7.14 user guide and installation instructions

ApacheHVAC User Guide Part F: Loads Analysis and Reporting Tools

LYNX CE CENTRAL CONTROL FOR OSMAC. General Specifications

1. Lenel Job Aid: Logging into Lenel RDS. Logging into the Lenel RDS webpage

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

HERCULES 6 GRAPHICS SYSTEM

Copyright 2017 Integrated Environmental Solutions Limited. All rights reserved.

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS

QA16 Addressable Panel Programming Manual V3.07.3

SUPERINTEND VRE-08/16/32/64

Building Technology III New York City College of Technology. Course Day 21 Revit Day 12 (Project Day 10)

Diagnostics and Monitoring System WEB Tool 2. User Manual

Using the Dome Motion Detector with SmartThings. Table of Contents

Milestone XProtect Alarm Matrix Integration 1.0

Temperature Monitoring, Operation and Maintenance of Research Freezers and Refrigerators SOP-TMOMRFR-01

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

NYS Vaccines for Children (VFC) Program Fridge-Tag 2L Data Logger: Implementation and User Guide

New Features. IES Virtual Environment 6.4

Alarms and Events. Defining Alarm Conditions. Database-Generated Alarms

HITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018

Setting up and Managing Alarms in McAfee ESM 10.x

Air Server & Multi Channel Samplers (MCS06 & MCS08)

This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b)

LYNX SE CENTRAL CONTROL FOR NETWORK GDC. General Specifications

BeneVision Central Monitoring System. Quick Reference Guide

Transcription:

WORKING WITH MEP ELEMENTS Smart Sprinklers extension Smart Sprinklers application for Autodesk Revit MEP......allows designers to quickly distribute sprinklers in a model with a real time interference checking....automatically routes sprinklers through pipes to the distribution pipes. Customizable routing rules allow you to connect sprinklers directly to fittings with or without sprinkler heads....automatically pre-calculates diameters for range and distribution pipes by different standards (ISO, AS, NFPA, etc)....values of default parameters for sprinkler planning, pipe sizing and pipe routing types, such as Sprinkler-to-Range Pipe, Range Pipe-to-Distribution Pipe, are based on ISO, AS, NFPA, etc. standards....default parameters are easily customizable by building and saving different routing and sizing configurations.

Smart Sprinklers - powerful Autodesk Revit MEP solution for sprinklers' location planning in the BIM model and automation of pipe routing from sprinklers to distribution pipes.

Smart Sprinklers has an E-Help where users can find a sample project and explore it:

Insert Position Symbol as Virtual Group Insert Position Symbol as Virtual Group inserts virtual group with created elements into a space with different boundaries. Virtual group elements are used for better review and analysis of position for future sprinklers.

Insert Position Symbol as Virtual Group Steps to insert the virtual group: 1. Select space or element in the space. Boundaries and parameters of selected space will be used; 2. Select a wall for detecting X direction. Note: Virtual Group can t be copied or mirrored! Placement parameters can be locked

Insert Position Symbol as Virtual Group Length (X axis) maximum length of X axis in a room/space; Width (Y axis) maximum length of Y axis in room/space; Select Base Wall for X axis select wall from the project to detect another X axis. Selected wall

Insert Position Symbol as Virtual Group Element Placement Elevation - elevation where virtual group elements will be inserted. When inserting the first time, the element will be placed on the top of the room/space. Ceiling Virtual group element It is not necessary to put virtual group element exactly on the face of a ceiling. It will not affect sprinkler s location if the host is specified. Note: Element Placement Elevation should be defined prior the use of other functions to ensure proper positioning of sprinklers in rooms/spaces. Virtual group element will be inserted with elevation of 2500mm if the space upper limit is higher.

Insert Position Symbol as Virtual Group Real Number of Elements real number of elements that will be inserted into current room/space in accordance with its shape. Number in X axis, Number in Y axis number of virtual group elements in X and Y axes.

Insert Position Symbol as Virtual Group Distance X, Distance Y distance between virtual group elements in X and Y axes. These values will be used when Distribute by Spacing parameter is selected; Distribute by Spacing distribute preselected number of virtual group elements by space using Distance X and Distance Y parameter values:

Insert Position Symbol as Virtual Group Calculate Maximum in X and Y direction calculates maximum amount of virtual group elements that is needed in X and Y axes for current space.

Insert Position Symbol as Virtual Group Offset from Original in X/Y Axes virtual group will be moved with offset from the beginning in X or Y Axis. If these values are zero, virtual group elements will be centered in the room/space. Users can check distances between the first and last virtual group elements in the space in Calculated Data table.

Insert Position Symbol as Virtual Group Factor of Distances defines multiple of distances. For example, if Factor of Distances is set to 600, then distances between virtual group elements will be rounded to the nearest number that is a multiple of 600.

Insert Position Symbol as Virtual Group Minimum Distance from Wall defines minimum distance between the elements and the walls in a space in accordance with your own configuration of distribution of virtual group elements.

Insert Position Symbol as Virtual Group Mirror X, Mirror Y mirrors virtual group in X and Y axes.

Insert Sprinklers to Position Symbols Inserts selected sprinkler type to the selected virtual group in a project.

Sprinkler Pipe Routing Configuration (SPRC) Upright/Pendant Sprinklers by double clicking on a picture select pipe routing type for upright/pendant sprinklers:

Sprinkler Pipe Routing Configuration (SPRC) Configuration for pipe routing can be saved under user defined name for future use. Configuration can be saved, renamed, or deleted.

Sprinkler Pipe Routing Configuration (SPRC) Elevation of upright range pipe elevation of upright pipe from level:

Sprinkler Pipe Routing Configuration (SPRC) Add separate sprinklers if distance is less than adds separate pipes to sprinklers if distance between the main row and sprinklers is less than entered value.

Sprinkler Pipe Routing Configuration (SPRC) Connection to tap or fitting with pipe of length with this option ticked, you can connect sprinklers directly to taps or fittings (e.g. BlazeMaster fittings). Filling the parameter Pipe length predefines any sprinkler pipe length. On Off Note: Connection type depends on a chosen range pipe type, which is discussed further. On + Pipe length

Sprinkler Pipe Routing Configuration (SPRC) Note: You can define your own standards by creating folder with standard name and modifying text files inside that folders. Standard, Standard: range diameters, and Standard: distribution pipes diameters - allow you to choose from predefined overall system, range pipe diameter and distribution pipe diameter standards. These standards define rules for system calculations for pipe diameter, maximum possible sprinklers on range pipe with one diameter, etc.

Own standard preparation Please find the template standards on your computer: Open file Change needed 1st column Range pipe description 2nd column Layout position 3rd column connection position 4th column diameter of range pipe 5th column maximum number of fed sprinklers

Own standard preparation Pre-Calculate pipe diameter by tables in accordance with number of sprinklers connected in a row The first column of Smart Sprinklers text table refers to Range pipe description: 2 Range at remote end of all distribution pipes last 2 ranges 3 Last 3 ranges 1 Last range -1 All other range pipes Second column of Smart Sprinkler text table refers to Layout position: 2 2-end layouts 3 3-end layouts -1 All other layouts Third column of Smart Sprinklers text table refers to connection position: Side for side connection Center for center connections Fourth column of Smart Sprinklers text table refers to Diameters of range pipes; Fifth column of Smart Sprinklers text table refers to maximum number of fed sprinklers Note: Change range pipe descriptions,layout positions, connection positions, diameters and number of sprinklers to create your own standard

Own standard preparation Pre-calculate constant diameters of range pipes in consideration of total number of sprinklers on a range The differences between simple text file for range pipe Precalculation and the file that will be used for constant diameters are: No need to describe number of Last ranges. Always use -1 No need to describe Layout position. Always use -1 Mandatory to add last line : -1,-1,All,-1,-1

Sprinkler Pipe Routing Configuration (SPRC) Sprinkler head adaptor, Range pipe type, Add cap to range pipe and Distribution pipe type let you choose what family type to use for your sprinkler system. You can choose from family types loaded in project. Sprinkler pipe diameter lets you choose diameter of the pipe which connects sprinkler to range pipe. Note: Welded or mechanical connection can be used choosing pipe types. Note: Sprinkler pipe can only be connected with fittings. No welded connection possible.

Sprinkler Pipe Routing Configuration (SPRC) Minimal distances HO, VO, etc. (distance/sprinkler pipe diameter defines coefficient of the number of pipe diameters you can fit between pipes, e.g., in the figure shown, you have VO/Diameter = Minimal distances HO, VO, etc. (distance/sprinkler pipe diameter) 120/33=3,63 HO/Diameter = Minimal distances HO, VO, etc. (distance/sprinkler pipe diameter) 98/33=2,96 In this case, it could be less than 3 because there s some space left, but for project consistency it let s to choose 3.

Sprinkler Pipe Routing Configuration (SPRC) Range pipe split distance s measuring type defines whether pipe is split by a fixed distance or by a coefficient. Coefficient range from 0 to 1 and defines a multiplier for splitting. OR

Sprinkler Pipe Routing Configuration (SPRC) Insert range pipe sets configuration for Pendant and Upright sprinkler pipe connection. You can choose from three connection types.

Sprinkler Pipe Routing Configuration (SPRC) Maximal distance between pendant and upright rows for use of common range pipe sets distance Lengthen range pipe from the extreme sprinkler lengthens pipe from last sprinkler on range and defines the length. pendant >300 upright <=300

Connect Sprinklers to Distribution Pipe After you set up sprinkler pipe routing configuration, press OK and: Workflow 1. Select one sprinkler and distribution pipe to generate the whole system. Workflow 2. Select more than one sprinkler and distribution pipe to manually choose which sprinklers you want to include into a system.

Connect Sprinklers to Range Pipes (Current SPRC) Creates pipes from selected sprinklers in a space to range pipe using current configuration. Pipes will be created on the nearest range pipe. First select a sprinkler, and then a range pipe:

Connect Sprinklers to Selected Pipes (Current SPRC) Creates pipes from selected sprinklers in a space to range pipe using current configuration. Pipes will be created on the nearest project pipe. First select a range pipe in any place and then a sprinkler:

Insert Fittings Insert Fittings splits selected pipe and insert fittings on the connections. Select a pipe: Pipe is splitted and fittings are inserted:

Show Hierarchical List of System Show Hierarchical List of System creates sprinkler system tree to easily navigate and verify sprinkler system and to find design points in sprinkler system.

Pre-Calculate Range Pipe Diameters As you advance in your BIM project, sometimes you need to change your configuration. Pre-Calculate Range Pipe Diameters and Pre-Calculate Distribution Pipe Diameters functions allow you to update your system with new configuration, which you can either create or transfer from another sprinkler system. Pre-Calculate Range Pipe Diameters updates range pipe configuration according to Sprinkler Pipe Routing Configuration (SPRC). Connection type not updated. To update sprinkler systems range pipe configuration: Set or read new routing configuration; Select Distribution Pipe of system you want to update; Select Pre-Calculate Range Pipe Diameters.

Pre-Calculate Range Pipe Diameters As you advance in your BIM project, sometimes you need to change your configuration. Pre-Calculate Range Pipe Diameters and Pre-Calculate Distribution Pipe Diameters functions allow you to update your system with new configuration, which you can either create or transfer from another sprinkler system. Pre-Calculate Distribution Pipe Diameters updates Distribution pipe configuration according to Sprinkler Pipe Routing Configuration (SPRC). Connection type is updated. Sprinkler systems distribution pipe configuration is updated in the same way as range pipe configuration.

Turn On/Off Virtual Group Updater Turn On/Off Virtual group Updater virtual group can be updated automatically while making changes in the model if virtual group updater is turned on. Updater is turned on After moving the wall: Updater is turned off

Results Application is designed for planning your sprinklers' location in the model; Quickly distributed sprinklers in the model; Automatically routed sprinklers through pipes to the distribution pipes; Automatically pre-calculated diameters for range and distribution pipes by different standards (ISO, AS, NFPA, etc). Default parameters are easily customizable.

ENJOY WORKING WITH OUR PRODUCTS! AGA CAD Ltd T: +370 618 55671 E: support@aga-cad.com W: www.aga-cad.com