TECHNICAL LEAFLET. The proposed instrument is an extended version of the computerized Geiger-Muller indicator PT

Similar documents
PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

RIID capability in the palm of your hand

Nuclear Associates

Instrument Standards Used in Security Applications Presented by: Leticia Pibida, Ph.D.

ORTEC. Detective-Remote. Multiple Instrument Remote Monitoring and Control Software. The right software, the right solution, the right answer!

North American Technical Services

Kata products Kata DGM-1500 Turva

Setting the new standard for personal radiation detection.

Radiation Monitoring System RMS

Identify the following features and specifications for the ESP1

Radiation Monitoring Systems

Environmental radioactivity surveillance system of ANPA

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

Portable Survey Instruments NISP-RP-01

Tender Specifications. Supply of radiation detection equipment for EUSECTRA training centre Lot 2: Backpack for portable radiation detection system

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

Continuous and Point Level Measurement. Radiometric Sensors for Liquid and Solid Level Measurement

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

Dosimeters/Survey meters

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

A Continuous Air Monitoring Sampler for 125 I - RIS-125

Advanced Radiation Detection Equipment

requirements. Serial: USB or RSXXX Bluetooth GPS/GSM Ethernet Standard or rugged desktop or laptop PC or tablet; Android smartphone or tablet

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

Our Extended Personal Electronic Dosimeter (PED) Family

Radiation Alert Frisker INTERNATIONAL

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

Consultation Draft. Issue 2. Good Practice Guide No. 29. The Examination, Testing and Calibration of Installed Radiation Protection Instruments

AERIAL RADIATION & CHEMICAL DETECTION SYSTEM. DroneSENSOR TM Series. Particulate Alpha, Beta, Gamma & Airborne Chemicals

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers

ß-Aerosolmonitor FHT 59 C

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

ISO INTERNATIONAL STANDARD. Smoke alarms using scattered light, transmitted light or ionization

***** 2. Rev.1 is to be uniformly implemented by IACS Members from 1 July 2004.

Any scenario. Maximum protection. Radiation detection solutions for safety and security

HEALTH AND SAFETY PROGRAM 406 IONIZING/NONIONIZING RADIATION PROTECTION

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

COMPACT RADIOACTIVE AEROSOL MONITORING DEVICE FOR EARLY WARNING NETWORKS

AERIAL RADIATION DETECTORS

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

RAM GENE / RAM GENE-1

Technologies, Solutions, and Applications. Radiation-based Level

COMPANY PROFILE. DETECTION & MEASUREMENT OF IONIZING RADIATIONS RADIOLOGICAL MONITORING SYSTEMS HEALTH AND ENVIRONMENTAL SAFETY

ADVANCED RADIATION DETECTION EQUIPMENT

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR. February 2018 Serial Number PR and Succeeding Serial Numbers

GEOPHYSICAL ENVIRONMENTAL ANALYSIS EQUIPMENT AND SERVICES

Environmental Radiation Monitoring System

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS

P U B L I C N O T I C E

Area Monitor/Frisker Count Rate Meter Victoreen

Portable Instruments For First Response & In-Situ Analysis of Radiation

MetRad1 Handheld Metal/Gamma Detection Unit. Operation Manual. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 BNC

Dräger X-zone 5500 Multi-Gas Detection Device

Detective-200. Ruggedized, Ultra-High-Sensitivity, Transportable HPGe Radionuclide Identification System

Radioactivity dosimeter RD01. User's Manual

Radiation Safety and Equipment Considerations. Bonnie Meilner Regional Sales Manager LAURUS Systems Inc.

WM 00 Conference, February 27 March 2, 2000, Tucson, AZ RELEASE SURVEYING OF SCRAP METALS WITH THE IONSENS CONVEYOR A CASE STUDY

VERIFICATION OF IONISING RADIATION MONITORS FOR PRACTICAL USE IN HOSPITALS. C. Montes, F. Sáez, C. Martín, P. Collado, C. J. Sanz, E.

DMC 2000 Personal Electronic Dosimeter

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

Contamination Meter Users Manual

INTERNATIONAL STANDARD

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E

LUDLUM MODEL 44-3 LOW ENERGY GAMMA SCINTILLATOR. May 2018 Serial Number PR and Succeeding Serial Numbers

Maximizing safety and productivity. Nuclear Power Radiation Detection and Monitoring Solutions

American Nuclear Society (ANS)

stationary dose rate measuring systems

Surface Contamination Monitor. Operation Manual

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

600 Range Dialer Installation Manual. Version 1.0

22 Radiological and Environmental Monitoring Systems Functions, Basic Configuration, and Interfaces

HEALTH AND SAFETY MANUAL

50(394) IEC. ore content meter ore sorting equipment overvoltage (of a Geiger-Müller county tube)...

GRAPPLE SCANNER FOR RADIATION IN SCRAP METAL. Model Series ~ GRAPPLE SCAN- GR Models ~ GRAPPLE SCAN- GR-A, -B, -C, & -D

LUDLUM MODEL 44-7 Alpha, Beta, Gamma Detector. July 2012 Serial No. PR and succeeding Serial Numbers

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

Alpha Analyst. Integrated Alpha Spectrometer. Radiation Safety. Amplified.

ARCON/RAMSES: Current Status and Operational Risk

Density, Concentration and Solids Content. Non-contacting measurement

Pico Envirotec Inc., CA & ENVINET a.s., CZ NEW APPROACH TO GLOBAL MONITORING OF THE RADIOLOGICAL SITUATION; INDUSTRIAL, ENVIRONMENTAL & EMERGENCY

PURPOSE AND SPECIFICATIONS

DOE 2.17 Contamination Monitoring Instrumentation Study Guide. 00ICP330 Rev. 0 Page 1 of 23

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

Transcription:

PROJECT 01109-4 PRELIMINARY DOCUMENT 01109-4-SD-0001-EN PT01109-4 Fast acquisition time and high sensitivity gamma and beta spectrometer to survey everyday nutrition, hygienic and household goods for radionuclides contamination. The proposed instrument is an extended version of the computerized Geiger-Muller indicator PT01109-1. The PT01109-4 is a budget price computerized gamma and beta spectrometer. It has been designed for surveying of drinking water and food articles as well as hygienic products, household chemistry, cosmetics and building materials for Naturally Occurring Radioactive Materials (NORM) and artificially produced radionuclides. The instrument is dedicated to individuals and businesses to which the quality of everyday goods defines the living standard. The state-of-the-art of the instrument is governed by reversed Marinelli beaker geometry of the instrument test chamber. The space occupied by the tested specimen is tightly surrounded by detectors matrix. The detectors matrix contains sixteen proportional counters providing a derandomizing capability, where each proportional counter has its own dedicated readout interface. The counting impulses received from readout interface are digital signal processing undergo amplitude and time domains. The proportion of the area of the sphere built on the detectors matrix to the total area of the test chamber walls is greater than 1:2. The PT01109-4 is fitted to the PE-HD, IK06 and IP67 enclosure, which can be immersed in running water and be washed. The instrument is sensitive to gamma or gamma&beta radiation with wide range energy levels from 50keV to 1.4MeV. The wide range of detected energy levels makes the instrument useful for detecting the decay products from most NORM and artificial radioactive decay such as I-131, Cs-134, Cs-137, Sr-90. The energy domain result of the radioactive emission test is delivered in counts of captured photons and particles per second and per 100ml of sample volume for each 1024 MCA channels [cps/100ml per x/1024 channel MCA]. The PT01109-4 instrument complies with IEC 61563 standard requirements for equipment for measuring specific activity of gamma-emitting radionuclides in foodstuffs. o Fast acquisition time and high sensitivity of the instrument at the budget price o The detector matrix surrounds the test chamber (reversed Marinelli beaker geometry) and contains sixteen proportional counters providing a derandomizing capability, where each proportional counter has its own dedicated readout interface o The counting impulses received from readout interface are digital signal processing undergo amplitude and time domains o 1024-channel MCA to measure the low level gamma or gamma&beta emission, the instrument energy resolution is better than 12% o Sensor sensitive to gamma and beta radiation with an energy level from 50keV to 1.4MeV; will detect radionuclides such as I-131, Cs-134, Cs-137, Sr-90 o The test specimen is placed in a 100ml container that is normalized by geometrical shape and volume, the position of the container inside the test chamber is exactly the same during each performed test. o Low background design, the test chamber is shielded by a Pb layer o Desktop instrument, the enclosure is made of PE-HD; protection IP67 and IK06 o RS232 interface to host system (19200 bps 8-N-1) o The instrument data output format is suitable to paste directly in OpenOffice Calc worksheet o Powered from 12V 0.6A DC power source (12VDC/230VAC power adapter included) o Self-diagnostic function Designed to meet EC/ANSI Declaration of Conformity o IEC 61563:2001, Radiation protection instrumentation - Equipment for measuring specific activity of gammaemitting radionuclides in foodstuffs o Surveys everyday nutrition, hygienic and household goods for radionuclides contamination o Quickly and discreetly checks the quality of delivered goods for radionuclides contamination o Helps to identify the products that contains more radionuclides than others PT01109-4 P.394985 patent pending in EU PT01109-4 Fast acquisition time and high sensitivity gamma and beta spectrometer to survey everyday nutrition, hygieic and personal goods for radionuclides contamination. http://www.pelczar.com.pl/pt01109-4-desktop-radiation-spectometer.pdf PELCZAR TECHNOLOGY 1987-2011 All rights reserved.

PROJECT 01109-1 REV. 0 DOCUMENT 01109-1-TL-0001-EN PT01109-1 Geiger-Muller Radiation Indicator to survey everyday nutrition, hygienic and personal goods for radionuclides contamination. The instrument is dedicated to individuals and businesses to which the quality of everyday goods defines the living standard. The instrument target markets are purchasing and QC departments of supermarkets, restaurants, hotels, and hospitals, as well as private individuals. The PT01109-1 is a computerized Geiger-Muller indicator. It has been designed for surveying of drinking water and food articles as well as hygiene products, household chemistry, cosmetics and building materials for Naturally Occurring Radioactive Materials (NORM) and artificially produced radionuclides. Overall instrument compares radioactive activities between samples which have same, normalized volume. The instrument is sensitive to beta and gamma radiation with wide range energy levels from 30keV to 1.2MeV. The wide range of detected energy levels makes the instrument useful for detecting the decay products from most NORM and artificial radioactive decay. The high sensitivity of the indicators allows their use in indirect detection of radon in air. The result of the radioactive emission test is delivered in counts of captured gamma photons and beta particles per second and per 100ml of sample volume [cps/100ml]. The interpretation of the measurement results is a simple task performed by comparing the reading from tested samples to the reference specimen. The instrument operator has a choice of selecting his own reference or use the one included in the PT01109-1 set. To insure the repeatability of testing parameters, the specimen is tested after being placed in a 100ml normalized geometry test container. The PT01109-1 is a desktop instrument fitted to the PE-HD, IK06 and IP67 enclosure, which can be immersed in running water and be washed. The data output of radioactive emission of the tested specimen is in counts per integration time per 100ml of sample volume [cpt/100ml], and after each reading the measurement data is send to a remote PLC/RTU via an RS232 interface. The integration time period is software controlled. The test result delivered by the PT01109-1 Geiger-Muller Indicator is for guidance only and requires verification using more elaborate equipments. In case of suspecting the radiological contamination the operator should contact his local authority responsible for radiological safety. o The detector matrix is surrounds the test chamber (reversed Marinelli beaker geometry) and contains sixteen energy-compensated Geiger-Muller tubes, where each tube has its own dedicated readout interface and counter o Geiger-Muller tubes are sensitive to gamma radiation with an energy level from 30keV to 1.2MeV; the gamma sensitivity is 22 cps/mr/h (Co 60 ); the volume of a single GM tube 12.90 mm 3 o The test specimen is placed in a 100ml container o The test chamber is shielded by a Pb layer o The integration time is software controlled o Measurement of the low level gamma and beta radiation emission is in counts per integration time per 100ml of the sample volume [cpt/100ml] o The indicator is capable of capturing gamma and beta particles from the same nuclear decay as a two separate events o RS232 interface to host system (19200 bps 8-N-1) o The instrument data output format is suitable to paste directly in OpenOffice Calc worksheet o Powered from 12V 0.6A DC power source (12VDC/230VAC power adapter included) o Enclosure made of PE-HD; protection IP67 and IK06 o Self-diagnostic function o Expandable for Ethernet interface for remote reading of radiation Designed to meet EC/ANSI Declaration of Conformity o ANSI N42.35-2004 Evaluation and Performance Criteria of Radiation Detection Portal Monitor for Use in Homeland Security (excluding requirements 5.10 and 5.10.4.2) o Surveys everyday nutrition, hygiene and personal goods for radionuclides contamination o Quickly and discreetly checks the quality of delivered goods for radionuclides contamination o Helps to identify the products that contains more radionuclides than others PT01109-1 Geiger-Muller Radiation Indicator with 100ml test containers o Single unit netto price (EXW Niepolomice Poland, B2B only) is 2800 EUR per unit o The Manufacturing Pack is available for qualified customers (B2B only) PT01109-1 Geiger-Muller Radiation Detector to survey everyday nutrition, hygienic and personal goods for radionuclides contamination. http://www.pelczar.com.pl/pt01109-desktop-geiger-muller-radiation-indicator.pdf PELCZAR TECHNOLOGY 1987-2011 All rights reserved.

PROJECT XX109-X REV. 1.0 DOCUMENT 00109-1-TL-0001-EN The predominating ways of TENORM contamination prospecting transport elicit TENORM processing storage ALARA Project -an initiative for fighting the hazardous effects of Technologically Enhanced Naturally Occurring Radioactive Materials (TENORM) http://www.alara-project.com ALARA PROJECT PELCZAR TECHNOLOGY 1987-2011 All rights reserved.

PROJECT 01109-3 REV. 0 DOCUMENT 01109-3-TL-0001-EN PT01109-3 Submersible Geiger-Muller Radiation Detector The PT01109-3 is a seawater submersible low power sensor, which integrates the temperature and depth gauges with Geiger- Muller detector. It has been designed for surveying ocean euphotic depth up to 150m for artificially produced radionuclides as well as Naturally Occurring Radioactive Materials (NORM). The instrument can be used by industrial fisher to help them measure the seawater radioactive contamination on multiple depths before fishing attempt. The result of the measurement should help to optimize decision about selecting the fishing region and desisted fishing in case of contamination of the seawater. It also can be used on the buoy to monitor radionuclides level on sea waterways and roadsteads. The instrument is sensitive to gamma radiation with energy levels from 50keV to 1.25MeV and measure low level radiation emission sources. Typically, the PT01109-3 sensors are hanging on immersed vertical cable (each sensor in a different depths), and automatically perform readings of seawater temperature, radiation in counts per minute [cpm] and the sensor depth. Each sensor reading is transmitted to the surface base station located in vessel cockpit by wire connection. o Low power sensors can be permanently immersed in seawater up to 150m depth o Remote sensor reading of seawater gamma radiation, temperature and sensor depth o Remote self-diagnostic function of the sensor o Gamma radiation sensor is energy-compensated Geiger-Muller tube; sensitive: with an energy level from 50keV to 1.25MeV; gamma sensitivity: 22 cps/mr/h (Co 60 ); working range: 0.014-144 mr/h o Background compensated measurement of low level gamma radiation in counts per minute [cpm] o Operating temperature range from -5 C to 60 C (all components industrial grade -40 C to 85 C) o Sensors intrinsic safe powered from Surface Base Station o Surface Base Station and immersed sensors are pointto-multipoint network o Designed to operate within harsh industrial o Surface Base Station capable to support SAT ARGOS PTT or GSM/GPRS modem Designed to meet EC/ANSI Declaration of Conformity o ANSI N42.35-2004 Evaluation and Performance Criteria of Radiation Detection Portal Monitor for Use in Homeland Security (excluding requirements 5.10 and 5.10.4.2) o Polish Register of Shipping (PRS) 2007 -Rules for Classification and Construction of Sea-going Ship Part 8 -Electrical Installation and Control System o EN 60079-0 Electrical apparatus for explosive gas atmospheres. General requirements o Ready for Maritime Safety approval o Survey of ocean euphotic depth up to 150m to measure radiation levels from NORM (Naturally Occurring Radioactive Materials) and artificially produced radionuclides such as I-131, Cs-134, Cs- 137, Pu-239, Pu-240, Sr-90. o Help to optimize decision about selecting the fishing region. o For monitoring radionuclide levels on sea waterways, roadsteads and seaside facilities. PT01109-3 Submersible Sensor Block Diagram of PT01109-3 Submersible Geiger-Muller Radiation Detectors System PT01109-3 Submersible Geiger-Muller Radiation Detector PELCZAR TECHNOLOGY 1987-2012 All rights reserved. An Investor Wanted For This Project. More info at http://www.pelczar.com.pl/investor.html The technical specification is available for qualified customers on base of particular quotation request and under non discloser agreement only.

PROJECT 10109 REV. 2 DOCUMENT 10109-2-TL-0001-EN PT10109 GSM Wireless Geiger-Muller Radiation Detector The PT10109 is a wireless sensor, which integrates a GSM/GPRS modems and a Geiger-Muller detector. It has been designed for surveying petroleum, natural gas, and LPG production facilities for Naturally Occurring Radioactive Materials (NORM) and artificially produced radionuclides. The instrument is sensitive to gamma radiation with energy levels from 50keV to 1.25MeV with an effective dose rate measurement range between 0.01-200 µsv/h. The PT10109 is designed to operate within harsh industrial as well as hazardous areas ATEX ZONE-0. It can be permanently attached to field infrastructure and operated from an internal battery without the need for costly cabling and conduit runs, thus eliminating most of the permit and labour costs for layout planning and installation. The typical mode of operation is that the PT10109 automatically performs a few readings of effective dose radiation per day and after each reading transmits the measurement data to a remote PLC/RTU by GSM/GPRS infrastructure. o Device to be permanently attached to field infrastructure o GSM/GPRS wireless interface for remote reading of radiation o Design for 3 years maintenance free operation o Quad-band GSM/GPRS modem o The sensor is energy-compensated Geiger-Muller tubes, sensitive with an energy level from 50keV to 1.25MeV; gamma sensitivity: 22 cps/mr/h (Co 60 ); working range: 0.014-144 mr/h; effective capacity of detecting chamber 12.90 mm 3 o Sensitive to gamma radiation with an energy level from 50keV to 1.25MeV o Range of gamma radiation effective dose rate 0.01-200 µsv/h o Powered from internal battery o Construction of device enclosures under EN 60079-18 (encapsulation 'ma' ), ingress protection IP68 o IrDA port for configuration download o Remote self-diagnostic function Designed to meet EC Declaration of Conformity o EN 301 511 Radio spectrum matters o EN 60079-0 Electrical apparatus for explosive gas atmospheres. General requirements o EN 60079-18 Electrical apparatus for explosive gas atmospheres - Part 18: Construction, test and marking of type of protection encapsulation "m" electrical apparatus o Survey of petroleum, natural gas, and LPG production facilities to measure radiation levels from NORM and artificially produced radionuclides PT10109 GSM Geiger-Muller Sensor BLOCK DIAGRAM of PT10109 GSM Wireless Geiger-Muller Detector Geiger-Muller Tubes RF link Audio BUZZER PROXIMITY SW uc+rf GSM/GPRS PT10109 encapsulation 'ma' IRDA IR link BATTERY PATENT APPLICATION [WIPO ST 10/C PL387092] INFRASTRUCTURE PT10109 GSM Wireless Geiger-Muller Radiation Detector PELCZAR TECHNOLOGY 1987-2009 All rights reserved.

PROJECT 00109-1 REV. 1.0 DOCUMENT 00109-1-TL-0001-EN PT00109-1 ISM Wireless Geiger-Muller Radiation Detector The PT00109-1 is a wireless sensor, which integrates an ISM radio and a Geiger-Muller detector. It has been designed for surveying petroleum, natural gas, and LPG production facilities as well as drinking water and food articles production facilities for Naturally Occurring Radioactive Materials (NORM) and artificially produced radionuclides. The instrument is sensitive to gamma radiation with energy levels from 50keV to 1.25MeV. The high sensitivity of the detectors allows their use in indirect detection of radon gas in air. The PT00109-1 is designed to operate within harsh industrial as well as hazardous areas ATEX ZONE-1. It can be permanently attached to field infrastructure and operated from an internal battery without the need for costly cabling and conduit runs, thus eliminating most of the permit and labour costs for layout planning and installation. The typical mode of operation is that the PT00109-1 automatically performs a few readings of radiation emission in counts per second per sample volume [cps/l] per day and after each reading transmits the measurement data to a remote PLC/RTU by ISM radio. o Device to be permanently attached to field infrastructure o ISM wireless interface for remote reading of radiation o Design for 3 years maintenance free operation o The sensor is energy-compensated Geiger-Muller tubes, sensitive with an energy level from 50keV to 1.25MeV; gamma sensitivity: 22 cps/mr/h (Co 60 ); capacity of single GM detecting chamber 12.90 mm 3 o Higher counting efficiencies achieved by reversed Marinelli beaker geometry of the test chamber o Background compensated measurement of low level gamma and beta radiation emission in counts per second per sample volume [cps/l] o Estimation of NORM energy distribution by Half-Value Layer method o Uses bi-directional a ISM radio operating in the license free 869MHz RF band o Operating range: o 1km radio link range in open space o 100m unidirectional radio link range in an industrial environment o Up to 4km radio link range with a directional antenna o Powered from internal battery o Construction of device enclosures under EN 60079-18 (encapsulation 'ma' ), ingress protection IP68 o IrDA port for configuration download o Remote self-diagnostic function o Expandable point-to-multipoint network Designed to meet EC Declaration of Conformity o EN 300 220 EMC and radio spectrum matters o EN 60079-0 Electrical apparatus for explosive gas atmospheres. General requirements o EN 60079-18 Electrical apparatus for explosive gas atmospheres - Part 18: Construction, test and marking of type of protection encapsulation "m" electrical apparatus PT00109-1 Geiger-Muller Sensor o Survey of petroleum, natural gas, and LPG production facilities to measure radiation levels from TENORM o Survey of drinking water and food articles production facilities to measure radiation levels from NORM and artificially produced radionuclides o Survey of rain and/or snow precipitations to measure radiation levels from TENORM and artificially produced radionuclides o Can be configured as a desktop instrument and use to measure gamma and beta activities of liquid and bulk materials (food) on low contamination level usually masked by background radiation. BLOCK DIAGRAM of PT00109 ISM Wireless Geiger-Muller Detector Geiger-Muller Tubes RF link Audio BUZZER PROXIMITY SW uc+rf ISM RTX PT00109 encapsulation 'ma' IRDA IR link BATTERY PATENT APPLICATION [WIPO ST 10/C PL387092] INFRASTRUCTURE PT00109-1 ISM Wireless Gamma & Beta Radiation Detector (Geiger-Muller) PELCZAR TECHNOLOGY 1987-2011 All rights reserved.