IECEx Certificate of Conformity

Similar documents
IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conformity

Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:

INTERNATIONAL ELECTROTECHNICAL COMMISSlON IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conform ity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

srra, of Conformity IECEx Gert f cate ?-ot,b

IECEx Certificate of Conformity

slra IEC of Gonformity IECEx Cert f cate ü* t4

Ex-d luminaire type dklk 23 (V-CG-S) GHG W. Flameproof enclosure 'd', Equipment dust ignition protection by enclosure 't' Dr. F.

Survey of electrical equipment installed in hazardous areas on tankers

FLASHLIGHT ANSI STANDARDS

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME)

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

FLASHLIGHT ANSI STANDARDS

User s Manual YTA610 and YTA710 NEPSI Certification

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0


Certificate of Compliance

INTERNATIONAL STANDARD


Annubar Flowmeter Series

INTERNATIONAL STANDARD

VERSAFLOW VORTEX Supplementary instructions

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Australian/New Zealand Standard

Certificate of Compliance

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Integrated Solutions Low Voltage Systems

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

INSTRUCTION MANUAL (ATEX / IECEx)

AS/NZS :2015. Explosive atmospheres AS/NZS :2015. Part 1: Equipment protection by flameproof enclosures d

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

INSTRUCTION MANUAL (ATEX / IECEx)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

UL HAZARDOUS LOCATIONS SERVICES

OPTIBAR DP 7060 Supplementary Instructions

Certificate of Conformity

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

IECEx Certificate of Conformity

AS/NZS :2016. Explosive atmospheres AS/NZS :2016. Part 7: Equipment protection by increased safety e. Australian/New Zealand Standard

Compilation of regulatory approaches used in various countries. Information received by the Secretariat through a survey in 2009

Australian/New Zealand Standard

VQ500 Series Combustible Gas Detector Elements

Technical Data. Dimensions

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Electrical Installations Design, Selection, Erection and Inspection

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Tank Gauging System Special Safety Instruction

INTERNATIONAL STANDARD

Certificate of Compliance

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 1: General requirements. Australian/New Zealand Standard

Certificate of Compliance

ISO INTERNATIONAL STANDARD

4) Intrinsic Safety Certification

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

Understanding Hazardous Locations Concepts

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas.

Explosion-proof Immersion Heater Type D-8660

Operating Instructions

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Certificate of Compliance

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 21: Particular requirements Rigid conduit systems

Transcription:

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Date of Issue: 2014-05-14 Page 1 of 4 Certificate history: Issue No. 2 (2014-5-14) Issue No. 1 (2013-11- 16) Issue No. 0 (2013-6-7) Applicant: Federal Signal Corporation 2645 Federal Signal Drive University Park, IL 60484 Electrical Apparatus: Optional accessory: E1 Series of Industrial intercom Type of Protection: Intrinsic Safety "ib"; Flameproof "d" Marking: Ex d ib IIB T4 Gb (All models except for E1-JS-EX) Ex d [ib] IIB T4 Gb (Model E1-JS-EX) Approved for issue on behalf of the IECEx Certification Body: Position: Paul T. Kelly Principal Engineer, Global Hazardous Locations Signature: (for printed version) Date: 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by: UL LLC 333 Pfingsten Road Northbrook IL 60062-2096

Page 2 of 4 Manufacturer: Federal Signal Corporation 2645 Federal Signal Drive University Park, IL 60484 Additional Manufacturing location (s): This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2007-10 Edition: 5 IEC 60079-1 : 2007-04 Edition: 6 IEC 60079-11 : 2011 Edition: 6.0 Explosive atmospheres - Part 0:Equipment - General requirements Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in Test Report: US/UL/ExTR13.0026/00 US/UL/ExTR13.0026/01 US/UL/ExTR13.0026/02 Quality Assessment Report: US/UL/QAR06.0012/06

Page 3 of 4 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: E1 Series of Industrial intercom. Available as microphone, handset or Jack Station model. All models have three M20 openings. Consists of an Ex certified flameproof d enclosure that is provided with a metric threaded opening in the cover for an Ex certified flameproof d line bushing that provides connection between intrinsically safe circuits and input/output power connections. Model E1-JS, Jack Station, must be installed in accordance with Control Drawing 850000218A. Nomenclature for type: E1-SM-EX Echo Industrial Intercom with Short Microphone E1-GM1-EX Echo Industrial Intercom with 150mm Gooseneck Microphone E1-GM2-EX Echo Industrial Intercom with 330mm Gooseneck Microphone E1-GM3-EX Echo Industrial Intercom with 480mm Gooseneck Microphone E1-HND-EX Echo Industrial Intercom with Handset E1-JS-EX Echo Industrial Intercom with Jack Station Connection CONDITIONS OF CERTIFICATION: YES as shown below: Flamepath joint differs from Table 2 of IEC 60079-1. The enclosure has joint width of 37 mm, maximum allowable gap of 0.038 mm. The distance I of 22.6 mm is measured from the edge of the o-ring groove to the edge of the cover bolt per Figures 3 and 5 of IEC 60079-1.

Page 4 of 4 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): Issue 1: Addition of models E1-HND and E1-JS. Modifications to barrier board layout. Please refer to Annex for addtional details on entity parameters for Model E1-JS. Issue 2: Revised models to have M20 entries, added -EX to model numbers and revision drawings. Annex: Annex to IECEx UL 13.0028X Issue 2.pdf

Annex to IECEx UL 13.0028X Intrinsically safe entity parameters for model E1-JS-EX: The following intrinsically safe circuit parameters are applicable when connected to an intrinsically safe device complying with the 500V dielectric. 10,11 12,13 10,11,12,13 The following intrinsically safe circuit parameters are applicable when connected to an intrinsically safe device that does not comply with the 500V dielectric requirement. 10,11 12,13 10,11,12,13 I o 42.11 ma L o 0.18 mh L o /R o 2 mh/ω I o 97.8 ma L o 0.033 mh L o /R o 0.88 mh/ω I o 139.9 ma L o 0.016 mh L o /R o 0.616 mh/ω