Breathing Air Units Ultrapure MAIN FEATURES & BENEFITS Breathing Air System with adsorption dryer, CO - NOx and SO 2 removal, pre- and afterfilters and automatic condensate drains Guaranteed and validated separation efficiency Optimal adaptation and generous dimensioning of the components, long life-times of the processing stages, low differential pressure of the unit; result: low operation costs All units in cabinet construction INDUSTRIES Medical application Paint and finish industry Machine building industry and plant engineering / construction Donaldson Filtration Deutschland GmbH Büssingstr 1 D-2781 Haan Tel: +9 (0) 2129 569 0 Fax: +9 (0) 2129 569 100 E-Mail: CAP-de@donaldsoncom Web: wwwdonaldsoncom Technical alterations reserved (6/2018) F11901_06_2018_ENG
PRODUCT DESCRIPTION At the inlet (J) compressed air reaches a two stage fi lter combination (6,7) In this stage the air is separated from particles and condensate The condensate is drained off the system via the electronic condensate drain (12) The following desiccant dryer reduces the water vapour content of the compressed air down to a pressure dew point of 0 C (equivalent to a remaining water content of 0,11 g/m3) In the following processing stages (SP, AK, OX) is reduced below 500 ppm, SO 2 is reduced to a level below 1 ppm and the content of NOx below 2 ppm In addition to that oil vapour, hydrocarbon, tastes and odours are held back in the AK-stage up to a residual content below 0,003 mg/m 3 In the OX-stage the existing CO is transformed into through a catalytic reaction In this way the CO content is reduced to < 5 ppm In the after fi lter (dust fi lter) possible abrasion of the absorbent is removed Typical applications for the breathing air units are: Breathing air: Removal of oil and particles as well as tastes and odours, CO,, SO 2 and NO X * ab Größe 80S from size 80S 20 Option Superplus Ultraconomy MIAH 02 9 MT MISH 01 PI 01 1 13 PI 5 1 1 02 2 1 3 18 19 5 Atmosphäre atmosphere J 01 02 9 8 03 O 6 7 12 12 15* 10 Y1 Y2 10 15* 11 11 J O Feuchtluft-Eintritt wet air inlet Trockenluft-Austritt dry air outlet ndensat-austritt condensate outlet Regerationsluftaustritt regeneration air outlet 2 / 5
PRODUCT SPECIFICATIONS Features: Breathing air package incl absorption dryer, CO, -, NOx and SO 2 removal, pre- and after fi lter and automatic level controlled condensate drain Guaranteed and validated separation effi ciency All dryers are in cabinet construction Display of the operating status by LED Intermittend operation standard Optimal adaptation and generous dimensioning of the components Superplus Version including dewpoint dependent capacity control and text display Benefits: Turnkey system, no additional installation required, all components from one hand, technically perfectly matched to each other Breathing air quality in compliance with all relevant international standards, eg Pharmacopée Européenne; DIN EN 12021; DIN EN ISO 7396-1; BS275; ANSI/CGA G71; Z180, 1 M85; AS2299-1979; NZL5813 Optimum protection against mechanical damage and against dirt High operating safety, since all operating status can be detected easily at any time Link between dryer and compressor possible on central applications, therefore saving of compressed air Long life-times of the processing stages, low differential pressure of the unit; result: low operation costs Saving of energy and operational cost due to adaption of the purge air consumption to the actual operating conditions Indication of current dewpoint and function status as well as alarm and service messages on LCD text display in clear text ensures high operating safety of the adsorption dryer Technical Data Operating pressure: min bar (g) / max 16 bar (g) Ambient temperature: min + C / max +50 C Medium temperature: max +50 C Medium: Compressed air Power supply: 230 V or 115 V AC / 50 60 Hz or 2 V DC Power consumption approx 0 W Declaration of Conformity Type 35 S: acc to Directive 201/35/EU Pressure vessel design, manufacture, testing Adsorber: acc to Directive 201/29/EU Filter: acc to PED 201/68/EU 3 / 5
PRODUCT SPECIFICATIONS ALG Nominal flow inlet (1 bar, 20 C)* Regeneration air flow average (1 bar, 20 C) Air outlet (min) (1 bar, 20 C) Pressure drop new mbar * related to 1 bar (abs) and 20 C at intake of compressor and 7 bar (g) and 35 C inlet temperature Prefilter (Afterfilter) M (V) 35 S 35 7 28,5 160 0070 residual content of impurity at standard condition at the entry Particle category 2, ISO 8573-1 Oil (liquid phase) < 0,01 mg/m 3 Oil vapour and hydrocarbon < 0,003 mg/m 3 Water vapour DTP -0 C (= 0,11 g/m 3 ) < 500 ppm CO < 5 ppm SO 2 < 1 ppm NOx < 2 ppm tastes and odours tasteless and odourless SIZING Operating pressure bar (ü) Correction factor overpressure (fp) 5 6 7 8 9 10 11 12 13 1 15 16 0,63 0,75 0,88 1,0 1,12 1,25 1,38 1,50 1,63 1,75 1,88 2,0 2,13 Entrance temperature C Correction value temperature (f T ) 20 25 30 35 0 5 50 1,1 1,1 1,1 1,0 0,8 0,7 0,5 Example: V nom = 50, inlet temperature = 30 C, operating pressure = 10 bar (g), V 50 m 3 nom /h V korr = = = 32,9 f 1,38 * 1,1 Calculated dryer size: ALG, type 35 S / 5
DIMENSIONS Power supply * Flexible tube plug connection Foundation plan J: Wet air inlet O: Dry air outlet K0: Condensate outlet Type DN A B C D E F G H I J K L Weight mm mm mm mm mm mm mm mm mm mm mm mm kg 35 S G 1/2 650 30 1060 700 310 255 255 60 620 65 215 315 70 5 / 5